Records from 2016 to 2025. Most recent: operational control imposed, 15 May 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 16
12 May 2025
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130603
12 May 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8140178
13 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909399
3 August 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7758155
18 May 2023
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684891
5 May 2022
Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Extension · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436245
17 August 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7295540
5 October 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070247
31 July 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037709
11 July 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6745798
5 August 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6501314
29 June 2017
Deficiency Check · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6184517
13 June 2017
Drydock Exam · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6174871
9 November 2016
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6038611
9 November 2016
Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6045537
8 May 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5872717
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 May 2025
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect seaworthiness of a vessel is discovered or suspected, the OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of damage, and to effect permanent repairs. Vessel grounded due to heavy weather event and suffered damage. Make vessel available for Marine Inspector damage survey out of the water with all voids free of water and debris.
46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2025
Resolution: Vessel was made available for dry-dock damage assessment with all voids free of water and debris.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 May 2024
Resolved
Fire hose may be commericial fire hose or equivalent of not over 1.5" diameter or garden hose of not less than 5/8" nominal inside diameter. Identified leak in fire hose.
46 CFR 181.20-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 30 May 2024
Resolution: Fire hose rectified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
Spanner wrenches must be provided where a 1.5" diameter fire hose is required. No spanner wrench onboard.
46 CFR 181.310
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 30 May 2024
Resolution: Spanner wrench acquired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
At all inspections special attention shall be paid to insure no fire hazards exist and that guards or protective devices are provided in all hazardous places. Identified several areas of insulation separating from ceiling/bulkheads in engine room.
46 CFR 176.25-10 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 17 June 2024
Resolution: Received photos of the insulation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 May 2022
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. A hatch on a vessel may be weathertight that only operates on protected waters. A hatch must be attached to the hatch frame. forward hatch has a failed gasket allowing water intrusion. Hatch also requires lanyard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 24 May 2022
Resolution: Lanyard and gasket plpaced on hatch
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 May 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable and made watertight. Engine space must be vapor tight. Holes for electrical cables lead into main cabin. (see documents for photos)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 24 May 2022
Resolution: Flame retardant sealant completing the vapor tight requirement
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Bilge suction in engine space failed to actuate, check valve corroded in place.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 May 2022
Resolution: Replaced check valve
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 July 2019
Resolved
Provision must be made for closure of all vent duct cowls or scoops. The engine room vent closure was inoperable. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 July 2019
Resolved 23 July 2019
Resolution: Proved proper operation of the vent closure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 July 2019
Resolved
10% of child life jackets must be onboard. Only 8 of the required 9 child PFD's are onboard. Provide one additional child life jacket and re-label stowage container. Limited to 8 children until deficiency is rectified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2019
Resolved 25 July 2019
Resolution: Added one additional child lifejacket.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 23 July 2019
Resolved
Inspection and maintenance of lifesaving equipment shall be logged. No lifesaving maintenance log was onboard. Document lifesaving maintenance IAW 46 CFR 185.702.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 11 October 2019
Resolution: Received email from operator [name withheld] stating that they were under the impression that it was already taken care of since they have been documenting maintenance for some time. [name withheld] sent pictures with the email.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 July 2019
Resolved
Any vessel of at least five net tons which engages in coastwise trade on the navigable waters of the United States must have a Certificate of Documentation. COD onboard expired on 31 MAY 2019. Fee paid during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 July 2019
Resolved 23 July 2019
Resolution: Fee paid during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 August 2018
Resolved
Each life float must be fitted with a light. Port side life float is missing a waterlight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2018
Resolved 10 September 2018
Resolution: New light was installed. Owner provided images.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 June 2017
Resolved
Demonstrate proper operation of the FireBoy (pre-engineered firefighting system) to include start interlock. - 46 CFR 181.420
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2017
Resolution: Vessel has shown proof that the FireBoy is operating as designed and that the interlock only remains active for 15 seconds.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 June 2017
Resolved
Properly mark all lifejackets, life floats, and the ring buoy with the vessel name. - 46 CFR 185.604
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2017
Resolution: All PFDs have been properly marked with the vessel's name.
Lifesaving › Lifefloat › Not on Board
Issued 29 June 2017
Resolved
Complete the installation of life floats including a properly sized float-free weak link. - 46 CFR 180.130
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2017
Resolution: Witnessed proper installation of lifefloats.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 June 2017
Resolved
Prove 60' line for the life buoy. 46CFR80.70(c)
Condition: Design Flaw
Due 14 July 2017
Resolved 4 August 2017
Resolution: The correct length of buoyant lifeline has been installed to the satisfaction of the attending MI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 June 2017
Resolved
Post the COI under glass or other suitable trasparent material. 46CFR176.302
Condition: Design Flaw
Due 14 July 2017
Resolved 6 August 2017
Resolution: COI Posted on the bridge.
Lifesaving › Lifefloat › Serviceable
Issued 29 November 2016
Resolved
Two life floats found unservicable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2016
Resolved 8 December 2016
Resolution: Replaced with two servicable life flaots of same capacity and Q spec.
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 November 2016
Resolved
Adjust emergency fuel shut off valves to ensure 100% closure.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2016
Resolved 8 December 2016
Resolution: Shut off valve mechanism adjusted to provide 100% closure.
Lifesaving › Lifebuoys › Serviceable
Issued 29 November 2016
Resolved
Replace life ring.
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016
Resolution: Life ring replaced
Engineering › Pressure Vessel › Relief Valve
Issued 29 November 2016
Resolved
Replace relief valve to air compressor that does not exceed mawp of 125 psi.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016
Resolution: Installed relief valve rated to 115 psi.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 November 2016
Resolved
Provide mounting bracket for portable extinguisher in main cabin.
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016
Resolution: Extinguisher properly mounted.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 29 November 2016
Resolved
Properly secure deck cleat with washers with nuts.
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016
Resolution: Cleat secured with washers and nuts.
Engineering › Bilge Water Management System › Interface Detector
Issued 29 November 2016
Resolved
Securely affix high water alarm in engine room
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016
Resolution: High water alarm affixed.
Engineering › Bilge Water Management System › Manifold
Issued 29 November 2016
Resolved
Properly mark/label valves at bilge manifold in engine room
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016
Resolution: Valves labeled.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 November 2016
Resolved
Provide at least 32 Adult PFDs on main deck and label accordingly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016
Resolution: 32 PFDs available on main deck and labeled accordingly.
Construction/Loadline › Hull › Hull Plating
Issued 29 November 2016
Resolved
Properly repair all holes whihc remain inthe hull just below the deck joint due to removal of rub rail. Defered until next dry-dock 6/30/2017.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 23 July 2019
Resolution: Holes were filled.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 November 2016
Resolved
replace raw water line to generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 23 July 2019
Resolution: Raw water line was replaced.
Construction/Loadline › Structures › Manhole
Issued 29 November 2016
Resolved
replace forward hatch gasket.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 15 December 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 29 November 2016
Resolved
All air Sep's attached to prime movers need to be maintained to prevent excessive oil build up specifically starbaord side outboard.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 23 July 2019
Resolution: Maintenance performed.
Lifesaving › Lifefloat › Paddle
Issued 29 November 2016
Resolved
Paddles not provided with life floats.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2016
Resolved 8 December 2016
Resolution: Paddles provided
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 29 November 2016
Resolved
Must maintain a life-saving quipment log for inspections and maintenance.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 11 October 2019
Resolution: Received email from operator [name withheld] stating that they were under the impression that it was already taken care of since they have been documenting maintenance for some time. [name withheld] sent pictures with the email.
Engineering › Bilge Water Management System › Interface Detector
Issued 29 November 2016
Resolved
Must label high water alarms at operators station.
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 15 May 2017
Resolution: Completed