← All vessels
TAHOE SERENITY
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southwest District (CGD-SW) · Other hulls named TAHOE SERENITY
TAHOE SERENITY is a 1996 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1996, most recently in May 2025, along with 81 deficiencies, 3 operational controls and 1 casualty investigation in 2025.
Records from 1996 to 2025. Most recent: operational control imposed, 15 May 2025.
- Built
- 1996
- Last inspected
- 12 May 2025
- Documentation
- Case Pending · documentation file of 10 September 2026
- Deficiencies
- 81 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2025
Identity
1038507
WDE5589
434748
Flag
UNITED STATES
367368910, 367699480 (licence lapsed)
Maury page id
psix-434748
Inspections, by type
…with no type recorded2
Years with a record
16 calendar years (1996–2025)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)63.0 ft × 16.0 ft × 4.0 ft
Registered tonnagegross 81 / net 75
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portROUND HILL PINES, NV
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Simplified, Gross Ton
75 - Simplified, Net Ton
75 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI4517MMSI 367699480 · expired · compulsorily equipped · granted 27 October 2015, cancelled 7 March 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDE5589MMSI 367368910 · expired · compulsorily equipped · granted 17 July 2008, cancelled 22 September 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 24
12 May 2025
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130603
12 May 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8140178
13 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909399
3 August 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7758155
18 May 2023
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684891
5 May 2022
Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Extension · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7436245
17 August 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7295540
5 October 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070247
31 July 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037709
11 July 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6745798
5 August 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6501314
29 June 2017
Deficiency Check · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6184517
13 June 2017
Drydock Exam · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6174871
9 November 2016
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6038611
9 November 2016
Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6045537
8 May 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5872717
28 September 2015
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5731709
18 August 2014
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4891685
30 July 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4389682
23 May 2012
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4319668
22 July 2011
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4090741
17 September 2008
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3327031
15 April 2008
Deficiency Check · Simplified Stability Test · COI Inspection · Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3245586
22 February 1996
Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1433058
Deficiency record · 81
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 May 2025
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect seaworthiness of a vessel is discovered or suspected, the OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of damage, and to effect permanent repairs. Vessel grounded due to heavy weather event and suffered damage. Make vessel available for Marine Inspector damage survey out of the water with all voids free of water and debris.
46 CFR 176.600
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 May 2024
Resolved
Fire hose may be commericial fire hose or equivalent of not over 1.5" diameter or garden hose of not less than 5/8" nominal inside diameter. Identified leak in fire hose.
46 CFR 181.20-1 (OLD T)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
Spanner wrenches must be provided where a 1.5" diameter fire hose is required. No spanner wrench onboard.
46 CFR 181.310
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
At all inspections special attention shall be paid to insure no fire hazards exist and that guards or protective devices are provided in all hazardous places. Identified several areas of insulation separating from ceiling/bulkheads in engine room.
46 CFR 176.25-10 (OLD T)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 May 2022
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. A hatch on a vessel may be weathertight that only operates on protected waters. A hatch must be attached to the hatch frame. forward hatch has a failed gasket allowing water intrusion. Hatch also requires lanyard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 May 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable and made watertight. Engine space must be vapor tight. Holes for electrical cables lead into main cabin. (see documents for photos)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Bilge suction in engine space failed to actuate, check valve corroded in place.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 July 2019
Resolved
Provision must be made for closure of all vent duct cowls or scoops. The engine room vent closure was inoperable. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 July 2019
Resolved
10% of child life jackets must be onboard. Only 8 of the required 9 child PFD's are onboard. Provide one additional child life jacket and re-label stowage container. Limited to 8 children until deficiency is rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 23 July 2019
Resolved
Inspection and maintenance of lifesaving equipment shall be logged. No lifesaving maintenance log was onboard. Document lifesaving maintenance IAW 46 CFR 185.702.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 July 2019
Resolved
Any vessel of at least five net tons which engages in coastwise trade on the navigable waters of the United States must have a Certificate of Documentation. COD onboard expired on 31 MAY 2019. Fee paid during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 August 2018
Resolved
Each life float must be fitted with a light. Port side life float is missing a waterlight.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 June 2017
Resolved
Demonstrate proper operation of the FireBoy (pre-engineered firefighting system) to include start interlock. - 46 CFR 181.420
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 June 2017
Resolved
Properly mark all lifejackets, life floats, and the ring buoy with the vessel name. - 46 CFR 185.604
Lifesaving › Lifefloat › Not on Board
Issued 29 June 2017
Resolved
Complete the installation of life floats including a properly sized float-free weak link. - 46 CFR 180.130
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 June 2017
Resolved
Prove 60' line for the life buoy. 46CFR80.70(c)
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 June 2017
Resolved
Post the COI under glass or other suitable trasparent material. 46CFR176.302
Lifesaving › Lifefloat › Serviceable
Issued 29 November 2016
Resolved
Two life floats found unservicable.
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 November 2016
Resolved
Adjust emergency fuel shut off valves to ensure 100% closure.
Lifesaving › Lifebuoys › Serviceable
Issued 29 November 2016
Resolved
Replace life ring.
Engineering › Pressure Vessel › Relief Valve
Issued 29 November 2016
Resolved
Replace relief valve to air compressor that does not exceed mawp of 125 psi.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 November 2016
Resolved
Provide mounting bracket for portable extinguisher in main cabin.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 29 November 2016
Resolved
Properly secure deck cleat with washers with nuts.
Engineering › Bilge Water Management System › Interface Detector
Issued 29 November 2016
Resolved
Securely affix high water alarm in engine room
Engineering › Bilge Water Management System › Manifold
Issued 29 November 2016
Resolved
Properly mark/label valves at bilge manifold in engine room
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 November 2016
Resolved
Provide at least 32 Adult PFDs on main deck and label accordingly
Construction/Loadline › Hull › Hull Plating
Issued 29 November 2016
Resolved
Properly repair all holes whihc remain inthe hull just below the deck joint due to removal of rub rail. Defered until next dry-dock 6/30/2017.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 November 2016
Resolved
replace raw water line to generator.
Construction/Loadline › Structures › Manhole
Issued 29 November 2016
Resolved
replace forward hatch gasket.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 29 November 2016
Resolved
All air Sep's attached to prime movers need to be maintained to prevent excessive oil build up specifically starbaord side outboard.
Lifesaving › Lifefloat › Paddle
Issued 29 November 2016
Resolved
Paddles not provided with life floats.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 29 November 2016
Resolved
Must maintain a life-saving quipment log for inspections and maintenance.
Engineering › Bilge Water Management System › Interface Detector
Issued 29 November 2016
Resolved
Must label high water alarms at operators station.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 September 2015
Resolved
Vessel did not have current light list and Coast Pilot at time of inspection. Provide current light list onboard vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 September 2015
Resolved
The safety radio cert onboard at the time of inspection was issued to vessel under previous owner/operator. Provide proof of a safety radio cert for vessel.
Documentation › Certificates/Documents › FCC SSL
Issued 29 September 2015
Resolved
Vessel did not have a valid radio station license. The cert onboard expired in 2013 and was issued to vessel previous o/o under different vessel name.
Documentation › Certificates/Documents › Permit, Other
Issued 29 September 2015
Resolved
Vessel master did not have proof of radio operator permit. Provide radio operator permit.
Documentation › Certificates/Documents › Stability Letter
Issued 29 September 2015
Resolved
Vessel did not have the maximum number of passsengers allowed on 2nd deck marked as per 46CFR185.602(g). Properly mark the maximum passenger count.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 September 2015
Resolved
The generator did not have guards to protect from rotating belts. Install guards to make safe for workers.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 September 2015
Resolved
Several battery cable terminals were showing exposed wiring. Replaceidentified batter cable terminals.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 September 2015
Resolved
The remote fuel shutoff valve is not marked. Provide markings for the remote fuel shutoff valve pull.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 29 September 2015
Resolved
One of the required B-II extinguishers had been overlooked during the recent servicing. Provide proof the vessel has the number, type, and current servicing of portables.
Lifesaving › Lifefloat › Serviceable
Issued 29 September 2015
Resolved
The two 22 person life floats onboard are worn with countless number of cracks penetrating the core. Make proper repairs to both life floats as per the manufacturer's specifications.
Engineering › Fuel Oil Service System › Valve
Issued 29 September 2015
Resolved
Port side and center fuel shutoff valves as the fuel tank leak in the closed position. Identify cause of leak and make proper repairs.
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 September 2015
Resolved
At the time of inspection no PFD placards were posted for passengers. Post PFD donning placards for the types of PFDs carried onboard as per 46CFR185.516.
Construction/Loadline › Structures › Scuttle
Issued 29 September 2015
Resolved
The 2nd deck emergency means of escape (wood hatch) is not labeled and would not open all the way due to wood expansion. Make proper repairs to hatch and provide marking.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 September 2015
Resolved
Found lifefloat arrangement to not be float free. Lines were securly tied around outboard ends of the floats and around the stern. The daisy chain connecting the lifefloats was underneath the flag mounting, which would have held boath float to the vsl in the event of a sinking. The waterlights attached were mounted on the stern creating a snag for the baskets. Provide monthly inspection of lif
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 28 September 2015
Resolved
Provide proof of monthly lifesaving equipment inspections to the satisfaction of the attending marine inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 August 2014
Resolved
Replace life ring waterlight with approved type battery. 46 CFR 180.70
Lifesaving › Hand Flares › Expired
Issued 18 August 2014
Resolved
Provide current flares required by route. 46 CFR 184.710
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 August 2014
Resolved
Replace expired contents of first aid kit (asperin, burn gel) 46 CFR 184.710
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 August 2014
Resolved
Properly mount wheelhouse and bow storage fire extinguishers 46 CFR 181.500
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 August 2014
Resolved
Prove proper operation of fixef fire fighting system for generator 46 CFR 181.420(a)(3)
Construction/Loadline › Hull › Hull Plating
Issued 18 August 2014
Resolved
Provide U.T. Results for hull plating on starboard quarter next to fresh water storage tank 46 CFR 177.100
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 July 2012
Resolved
Replace extinguished visual indicator for forward bilge alarm. 46CFR182.530
Stability › Weathertight Integrity › General
Issued 30 July 2012
Resolved
Replace damaged portside deck drain. 46CFR 182.40-1(k)
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 22 July 2011
Resolved
Provide method of keeping passenger count ashore while underway IAW 46 CFR 185.504.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 July 2011
Resolved
Provide missing hose clamps IAW 46 CFR 182.410
Navigation › Piloting/Steering › Marine Charts
Issued 22 July 2011
Resolved
Provide updated chart for the vessel area of operation IAW 46 CFR 184.420 (a) (1).
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 July 2011
Resolved
Replace expired items in vessels first aid kit IAW 46 CFR 184.710
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240.
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
Alcohol testing devices not onboard as required by 46 CFR part 4.
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
Arrangements not made for reasonable cause testing as required by 46 CFR part 16.250 and 33 CFR part 95
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company’s drug and alcohol policy in accordance with 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
Employer does not have a Substance Abuse Professional (SAP) name and contact information in accordance with 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 17 September 2008
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 July 2008
Resolved
Provide proof of drug and alcohol program.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 July 2008
Resolved
Obtain copies of U.S. Coast Pilot and Coast Guard Light List.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 July 2008
Resolved
Post emergency broadcast placard by VHF-FM radio IAW 46 CFR 184.506.
Communications › Internal Communications System › Sound-powered Telephone
Issued 14 July 2008
Resolved
Prove proper operation of public address system IAW 46 CFR 184.610.
Operations/Management › Passenger Operations › Safety Orientation
Issued 14 July 2008
Resolved
Post life jacket donning placards IAW 46 CFR 185.516.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 July 2008
Resolved
Prove proper operation of fwd mast light.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 July 2008
Resolved
Make all exposed electrical connections weather tight.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 July 2008
Resolved
Provide on board proof of valid certificate of documentation.
Documentation › Certificates/Documents › FCC SSL
Issued 14 July 2008
Resolved
Provide onboard valid radio safety certificate, station license and marine radio operators permit.
Lifesaving › Hand Flares › Quantity
Issued 14 July 2008
Resolved
Provide onboard required number of visual distress signals and proper stowage box IAW 46 CFR 108.68 and 185.614.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 14 July 2008
Resolved
Post placard for fixed fire extinguishing system engine shut downs.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 July 2008
Resolved
Properly label all life jacket stowage bins & areas IAW 46 CFR 180.78
Casualty record · 1
12 May 2025Routine · role: Involved in a Marine Casualty · activity 8140178
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.