Records from 1996 to 2009. Most recent: inspection, 16 April 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
16 April 2009
Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3450077
14 June 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2961655
11 June 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2958231
4 April 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2901877
26 March 2007
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2895719
14 June 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2679781
6 May 2004
Re-Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2056712
5 November 2003
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1939838
4 November 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1942771
4 November 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2252779
18 September 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1908530
18 April 2003
Re-Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1774932
16 October 2002
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1692063
15 October 2002
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1690375
23 May 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 290266
21 August 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 281771
9 May 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 277594
19 November 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 434888
19 November 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 539542
22 April 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 427648
18 November 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 422651
12 April 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 414500
8 May 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 403146
7 March 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 401140
19 July 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 393304
27 March 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 206660
27 March 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 766010
24 January 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 386746
Fire Fighting › Structural - B Class Divisions › Doors
Issued 16 April 2009
Resolved
"B" Class entry door and frame leading to crew laundry room located on main deck is deteriorated to the point where resistance of door is not equivalent to class "B" division boundary in which it is fitted. Large holes are present on the lower portion of the door as well as the adjacent door frame. Make repairs to the satisfaction of class prior to departure. SOLAS 2004 CH II-2 Reg 9/4.2.1 17a,c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2009
Resolution: Crew replaced and repaired door and frame for crew''s laundry room at upper deck in accomodation. (On main deck) See attached NK Class Report for details.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 11 June 2007
Resolved
The marine sanitation device appears to be working improperly. It is giving off an odor and when the cap was opened, it was found full and overflowing. Automatic discharge is to be redirected to a holding tank due to improper treatments. Vessel shall have class attend vessel and inspect equipment prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2007
Resolution: Looked at by class and fixed to his satisfaction. Vessel will have system overhauled by company in Japan
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 11 June 2007
Resolved
The Marine Sanitation Device is not being maintained as per instructions. The instructions call for one 20 gram chemical tablet per person using the system per month. The tablet container is in a language that crew can't read, and the crew is inserting tablets as they dissolve. So, the crew does not know how may grams they are inserting . Company must provide appropriate chemicals/instructions.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 August 2007
Resolution: Received report from Class with Technicians report stating that system was functioning properly and in good working order.
Fire Fighting › Fire Hoses › Condition
Issued 11 June 2007
Resolved
One of the fire hoses on aft deck has a small leak. No spares are maintained onboard. Vessel should pressure test all fire hoses, replace the leaking hose, and obtain a spare hose to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2007
Resolution: Vessel faxed receipt verifying the purchase of 02 fire hoses
Construction/Loadline › Structures › Ventilators
Issued 11 June 2007
Resolved
Gaskets for all ventilation openings, including goosenecks, found dried out, cracked, and peeling away throughout vessel. Crew should inspection all gaskets and replace as needed to the satisfaction of class. Report should be faxed to USCG.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 August 2007
Resolution: Received a report from the Master with along with a Class report sating that the gaskets have been replaced.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 11 June 2007
Resolved
Voyage planning does not include tides/currents from pilot station to berth, nor is crew calculating for squat/air draft/under keel clearance. Vessel should update planning in accordance with IMO Resolution A.893(21) prior to movement.
Action required: 705 - Other - as specified
Resolved 14 June 2007
Resolution: Received fax with needed info. All Sat
Fire Fighting › Structural - A Class Divisions › Doors
Issued 11 June 2007
Resolved
Fire boundary doors throughout vessel, though equipped with self closing devices, are out of alignment and must be adjusted to the satisfaction of class/flag, and report faxed to USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2007
Resolution: Deficiency rectified to satisfaction of class
Operations/Management › Pollution › Removal Methods/Procedures
Issued 11 June 2007
Resolved
Color coding scheme specified in garbage management plan is inconsistent throughout the vessel. Some mixed garbage was found in galley and aft garbage collection point. Vessel should implement color scheme and ensure proper separation is taking place to the satisfaction of class/flag, with report faxed to USCG.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 August 2007
Resolution: Received a report from the Master along with picture showing the proper color coding and stenciling of garbage cans.
Fire Fighting › Fire Bucket › Stenciling
Issued 14 June 2006
Resolved
THE FIRE DAMPER WAS NOT LABELED. MUST BE LABELED AND HAVE OPERATING INSTRUCTIONS. TO THE SATISFACTION OF CLASS.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 July 2006
Resolved 26 March 2007
Resolution: Fire Damper labeled Funnel Damper.
Construction/Loadline
Issued 23 May 2001
Resolved
Ensure maagement is informed concerning correct answer on Ballast Water Report form.
Condition: Unknown
Due 23 May 2001
Resolved 4 June 2001
Deck/Cargo
Issued 23 May 2001
Resolved
Prepare both anchors for letting go in case of emergency while transitting the Columbia and Willamette Rivers.
Condition: Unknown
Due 23 May 2001
Resolved 4 June 2001
Fire Fighting
Issued 23 May 2001
Resolved
Repair Firemans breathing apparatus where leaking prior to departure._x001C_
Condition: Unknown
Due 23 May 2001
Resolved 4 June 2001
Engineering
Issued 9 May 2000
Resolved
Ensure quick closing valve system at fire control station remains charged with air and ready for immediate use. Repair slow leaks near valves prior to next U.S. port. SOLAS 74 AMD I/11.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Fire Fighting
Issued 9 May 2000
Resolved
Free-up and lubricate sprinkler valve at Forward paint locker prior to nextU.S. port. SOLAS 74 AMD I/11.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Fire Fighting
Issued 9 May 2000
Resolved
Provide (2) fully charged spare air bottles for SCBA prior to next U.S. port. SOLAS 74 AMD II-2/17.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Accommodation/Occupational Safety
Issued 9 May 2000
Resolved
Properly label emergency escape trunk door at main deck prior to next U.S. port. SOLAS 74 AMD II-2/45.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Fire Fighting
Issued 7 March 1997
Resolved
Complete permanent repairs to defective friction clutch for emergency fire pump vacuum pump accessory prior to next U.S. port-call after sailing foreign.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997