MAURY USCG vessel records
← All vessels

FAMILY PRIDE

FAMILY PRIDE is a 1995 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2017, most recently in February 2026, along with 6 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 3 February 2026.

Built
1995
Last inspected
3 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 February 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM3015
435131
Flag
UNITED STATES
Maury page id
psix-435131

Documentation record

Registered dimensions (L × B × D)64.8 ft × 19.7 ft × 7.2 ft
Registered tonnagegross 61 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE, INC. · PANAMA CITY, FL, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Simplified, Gross Ton
49 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 22

3 February 2026 Annual Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8305987
27 June 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8169023
6 February 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8075917
4 February 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8074573
31 January 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7852712
26 October 2023 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7814664
15 February 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7637206
6 December 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7604954
29 August 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7546340
9 February 2022 Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 7395376
10 November 2021 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7344565
12 May 2021 Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7201859
14 April 2021 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7171433
17 February 2021 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7142833
28 December 2020 Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 7120495
18 September 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6814772
18 September 2019 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6814877
29 January 2019 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6616715
19 September 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6544354
19 June 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6180075
15 May 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6146970
9 January 2017 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6068278

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2024 Resolved
Vessel required to have posted PFD donning procedures for each Type I carried onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 February 2025
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2024 Resolved
Vessel required to have onboard a Type 1 PFD for total passengers allowed (54). Vessel restricted to 46 total passengers until 08 more adult Type 1 PFDs are onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 February 2025
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 April 2021 Resolved
Inspect life floats in accordance with 46 CFR 180.200. Life float painter lines were not properly secured.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2021
Resolution: Painters secured.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 April 2021 Resolved
Provide portable extinguishers in accordance with 46 CFR 181.500. 10-B:C portable extinguisher was missing from operating station.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 September 2019 Resolved
All vessels shall be provided with not less than two avenues of escape from all areas accessible to the passengers. The passenger accommodation space does not have a 2nd means of escape. Vsl will submit plans for installing a 2nd means of escape to the satisfaction of the attending MI.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2021
Resolution: Second means of escpae installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2019 Resolved
Material Review. This portion of the inspection consists of a general examination of the vessel, and witnessing crew performance of drills. Drills were not conducted due to weather. Drills must be evaluated by the attending Marine Inspector (MI) prior to the carriage of passengers. 46 CFR 8.545
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2021
Resolution: Satisfactory drills were observed/discussed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.