Records from 1985 to 1994. Most recent: inspection, 22 May 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
22 May 1994
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 859846
20 May 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 827396
30 November 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1136344
12 May 1992
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 953718
16 December 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1259216
5 June 1991
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 922008
5 June 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1234221
18 April 1991
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 934910
29 March 1990
Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 931251
29 March 1989
Re-Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 894436
19 April 1988
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1031287
31 August 1987
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1007107
9 April 1986
Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 999642
8 April 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1295428
Navigation
Issued 12 May 1992
Resolved
MAKE CORRECTION/REPAIR TO AFT STEERING LINKAGE (CLEVICE PIN)
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Lifesaving
Issued 12 May 1992
Resolved
PROVIDE ONE ADDITIONAL ADULT PFD (TOTAL PERSONS LIMITED TO 24 UNTIL CORRECTED) COMPLIANCE DATE: 23JUN92
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Lifesaving
Issued 12 May 1992
Resolved
PROPERLY MARK CHILD SIZE PFD STOWAGE AREA_x001C_ COMPLIANCE DATE 23JUN92
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Electrical
Issued 12 May 1992
Resolved
MAKE PROPER TERMINATIONS TO WIRES LOCATED IN CONTROL PANEL BOX, MID-SHIP BILGE AREA AND CB RADIO AREA_x001C_ COMPLIANCE DATE: 23JUN92
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Engineering
Issued 12 May 1992
Resolved
CORRECT LEAKAGE IN SHAFT STUFFING BOX_x001C_ COMPLIANCE DATE: 23JUN92
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Fire Fighting
Issued 12 May 1992
Resolved
PROVIDE SERVICING FOR CO2 FIRE EXTINGUISHERS. (COPY OF RECEIPT CAN BE MAILED TO OFFICE)_x001C_ COMPLIANCE DATE: 23JUN92
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Construction/Loadline
Issued 12 May 1992
Resolved
PROVIDE FOR PROPER OPERATION OF BILGE PUMP LIGHTS_x001C_ COMPLIANCE DATE: 23JUN92
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Electrical
Issued 5 June 1991
Resolved
INSTALL BATTERY DISCONNECT SWITCH
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Fire Fighting
Issued 18 April 1991
Resolved
HAND BILGE PUMP NOT RIGGED TO OPERATE AS HAND FIRE PUMP.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Engineering
Issued 18 April 1991
Resolved
HEAT SHIELD FOR FOR FUEL FILTER NOT INSTALLED.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Navigation
Issued 18 April 1991
Resolved
INSTALLEDE ELECTRIC HORN NOT OPERATIONAL.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Fire Fighting
Issued 18 April 1991
Resolved
FIRE EXTINGUISHERS NOT MOUNTED IN PROPER MARINE BRACKETS.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Navigation
Issued 18 April 1991
Resolved
chart of operating area more than three yrs. old and not updated.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Lifesaving
Issued 29 March 1990
Resolved
REFASTEN SUPPORT BRACKETS FOR LIFE RING AND WATER LIGHT
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Documentation
Issued 29 March 1990
Resolved
SUBMIT A LETTER TO THE CG STATING THAT YOUR DRUG TESTING PROGRAM HAS BEEN STARTED BY 21DEC90
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Lifesaving
Issued 29 March 1990
Resolved
REFASTEN WATER LIGHT BRACKET ON BUOYANT APPARATUS
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Navigation
Issued 29 March 1990
Resolved
PROVIDE LIGHT LIST COAST PILOT RULES OF THE ROAD, NOTICES TO MARINERS AND CG REGULATIONS (46CFR SUBCHAPTER T)
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Electrical
Issued 29 March 1990
Resolved
OBTAIN ONE ADDITIONAL FLASHLIGHT
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Engineering
Issued 29 March 1990
Resolved
REMOVE EXCESS OIL FROM BILGES
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Engineering
Issued 29 March 1990
Resolved
CLEAN BOTH FUEL VENTS
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Lifesaving
Issued 29 March 1990
Resolved
PROVIDE TWO PFD'S (ADULT) PASSENGERS LIMITED TO 19 UNTIL PROVIDED
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Electrical
Issued 29 March 1990
Resolved
BLOCK AND BRACE BATTERIES
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Construction/Loadline
Issued 29 March 1990
Resolved
REFASTEN & RECHUCK 2ND BOARD PORT & STBD SIDE IN WAY OF KEELSON BY TRANSOM
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Construction/Loadline
Issued 29 March 1990
Resolved
REPLACE MISSING VENT SCOOP ON STBD SIDE OF VESSEL
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Lifesaving
Issued 29 March 1989
Resolved
PROVIDE WEAK LINK OF PROPER SIZE FOR BOUYANT APPARATUS
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 29 March 1989
Resolved
PROVIDE 4 PFD'S (ADULT). PASSENGERS LIMITED TO 19 UNTIL PROVIDED
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 29 March 1989
Resolved
RENEW STRAPS ON BOUYANT APPARATUS & REATTACH LIFELINE
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Engineering
Issued 29 March 1989
Resolved
REPLACE FORWARD ELECTRIC BILGE PUMP DISCHARGE HOSE
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Engineering
Issued 29 March 1989
Resolved
REPLACE PORT ENGINE EXHAUST FLEX HOSE
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Navigation
Issued 29 March 1989
Resolved
READJUST RUDDER PACKING TO MINIMIZE LEAKAGE ACTUAL COMPLIANCE DATE FOR ALL ABOVE REQUIREMENTS: 29APR89
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 29 March 1989
Resolved
PROVIDE WATER LIGHT FOR RING BOUY & BOUYANT APPARATUS. RESTRICTED TO DAY- LIGHT OPS UNTIL PROVIDED
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 19 April 1988
Resolved
PROVIDE SIX ADULT PFD'S AND PROPERLY STENCIL WITH VESSEL NAME. PASSENGERS LIMITED TO 16 UNTIL PROVIDED.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Lifesaving
Issued 19 April 1988
Resolved
PROVIDE STENCILING OF PFD STOWAGE AREA INCLUDING NUMBER OF JACKETS & DISTINCTION BETWEEN CHILD AND ADULT.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Fire Fighting
Issued 19 April 1988
Resolved
PROVIDE PROOF OF SERVICING OF CO2 (3) PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Deck/Cargo
Issued 19 April 1988
Resolved
PROVIDE THREE LIGHTS ON NAVIGATION PANEL FOR EACH BILGE PUMP.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Deck/Cargo
Issued 19 April 1988
Resolved
RENEW BILGE LINE TO FORWARD BILGE PUMP. REPLACEMENT SHALL BE A MINIMUM OF 1" NOMINAL DIAMETER AND REINFORCED AND RESISTANT TO PETROLEUM.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Deck/Cargo
Issued 19 April 1988
Resolved
PROPERLY PIPE FORWARD BILGE PUMP OVERBOARD.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Deck/Cargo
Issued 19 April 1988
Resolved
REMOVE EXCESS OILS FROM BILGES.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Construction/Loadline
Issued 19 April 1988
Resolved
PREPARE VESSEL FOR UNDERWAY EXAM DUE TO LEAKAGE AT RUDDER STOCK, TAILSHAFT PACKING AND STEM.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Electrical
Issued 31 August 1987
Resolved
REMOVE EXCESS OR UNUSED ELECTRICAL CABLE THROUGHOUT BOAT. PROPERLY SUPPORTREMAINING CABLE EVERY 24". ANY REPLACEMENT WIRING SHOULD BE OF THE UL APPROVED BOAT CABLE.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Deck/Cargo
Issued 31 August 1987
Resolved
PROVIDE SECURING DEVICE TO ENGINE BOX.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Construction/Loadline
Issued 31 August 1987
Resolved
PROVIDE WOODEN PLUGS TO TWO OVERBOARD DECK DRAINS/SCUPPERS. SCUPPERS SHALLREMAIN PLUGGED UNTIL UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Unknown
Issued 31 August 1987
Resolved
ELIMINATE DIESEL FUEL LEAKAGE BY WAY OF PRIMARY FUEL FILTER.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Navigation
Issued 31 August 1987
Resolved
OBTAIN VALID MARINE RADIO OPERATOR PERMIT.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Deck/Cargo
Issued 31 August 1987
Resolved
REMOVE EXCESS FUEL FROM BILGES.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Deck/Cargo
Issued 31 August 1987
Resolved
PROVIDE A POSITIVE ACTION VALVE OR COCK FOR THREE THRUST HOSE FITTINGS FORBILGE PUMPS AND COOLING WATER DISCHARGE.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Deck/Cargo
Issued 31 August 1987
Resolved
PROVIDE OVERBOARD BILGE PUMP LINE FOR FORWARD COMPARTMENT.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Lifesaving
Issued 9 April 1986
Resolved
PROCURE AND PLACE ON BOARD SEVEN (7) ADULT SIZE LIFE PRESERVERS. UNTIL COMPLETION OF THIS REQUIREMENT, VESSEL IS LIMITED TO 18 PERSONS TOTAL.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986