01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 20 February 2025
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Provide crew and perform required drills to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Completed drills with designated crew.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 20 February 2025
Resolved
Each survival craft must be:(1) Secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter. Vessel has certified spare on board. The hydro release was mistakenly removed with IBA. Provided valid hydrostatic release for IBA.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Vessel installed new hydrostatic release for temp IBA.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 February 2025
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Engine room ventilation closing devices were not installed. Install and provide test to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Closing devices were installed and tested SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 February 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Generator main junction box was only being secured by one of four mounting fastenings. Mount the generator terminal box securely as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Generator main terminal box was properly fastened to the gen set.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 February 2025
Resolved
Vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, EPRIB not mounted. Properly mount EPIRB to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: EPRIB was mounted on the back of the operating station.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 February 2025
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Provide monthly testing log to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 3 April 2025
Resolution: Vessel and crew provided monthly test logs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 February 2025
Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port nd starboard bow and the stern of the vessel. The hailing of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel stern missing hailing port. Properly mark hailing port on stern of vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 3 April 2025
Resolution: Hailing port was marked on the stern of vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 February 2025
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on
which the unit was installed. Vessel replaced on site and scratched off expiration date two years from install
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 March 2025
Resolution: Vessel replaced on site.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 March 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel's last fire service record indicated July 2022 on the inspection tags. There was no record available for a 2023 inspection. Service all fire extinguishing equipment and provide records to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2024
Resolution: Service by Langkilde's Fire Service on 29Mar24.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 March 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load water waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Alarm indication for the galley and the bow did not actuate on the operating station indicating panel. Automatic operation of the bow submersible bilge pump did not indicate on operation panel. Repair bilge float switches and indicator panel and prove to the attending marine inspector the system is working as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2024
Resolution: Bow electrical sub pump tested sat. Alarms at operating station tested sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 March 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel's last fire service record indicated July 2022 on the inspection tags. There was no record available for a 2023 inspection. Service all fire extinguishing equipment and provide records to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2024
Resolved 2 April 2024
Resolution: Vessel addded monthly extinguisher insepction to the vessel inspection log.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Vessel's ring life buoy was not marked with Type II retroreflective tape. Mark lifebuoy with Type II retroreflective tape IAW with IMO Resolution A.658(16).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 July 2026
Resolution: Issued another RLB def on 21JUL26.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 March 2024
Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Vessel had two lifejackets that were deemed out of service. One jacket buckle broke apart and the other had several holes. Vessel removed from service. The two removed from service left 52 life jackets which was more than the required 51 on the COI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 March 2024
Resolution: Removed damaged lifejackets from service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2023
Resolved
Piping used in a vital system must: (1) Be composed of ferrous materials except when: (i) Nonmetallic piping materials are permitted by § 182.720; or (ii) Nonferrous metallic piping materials are permitted by § 182.730. The bilge manifold was found with an unauthorized "Splash Zone" patch and a clear plastic hose was found on the discharge side of the bilge pump. Properly repair or replace bilge manifold and remove unauthorized tubing form the bilge discharge piping.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2023
Resolved 25 April 2023
Resolution: Vessel replaced manifold and provided ferrous metal piping.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2022
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. The 10-B:C extinguisher required for the operating station was found missing. Provide missing extinguisher.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 4 August 2022
Resolution: Vessel provided missing extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 July 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. When system was tested the generator did not shut down. Generator did have seperate remote stop in the galley. Demonstrate shut downs of all require engines upon testing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 4 August 2022
Resolution: Vessel corrected wiring and demonstrated shut down.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2022
Resolved
Each ring life buoy must Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring life buoy was found with significant sun damage and not fit for service. Replace ring buoy.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 15 September 2022
Resolution: Vessel provided new ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 July 2022
Resolved
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). Four life jackets were found with significantly degraded retro reflective material. Replace retro reflective tape.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 4 August 2022
Resolution: Vessel replaced retro.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 July 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit was missing tourniquet and instructions. Provide complete kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 4 August 2022
Resolution: Vessel provided missing items.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 July 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel was found with multiple styles of life jackets and the provided placard only addressed one type. Provide donning instructions for all types of life jackets on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 4 August 2022
Resolution: Vessel provided additional donning instructions.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 21 July 2022
Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency instructions were not vessel specific. Provide instructions for the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 4 August 2022
Resolution: Vessel provided vessel specific emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 July 2022
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly portable fire extinguisher checks were not logged as completed. Conduct and record inspections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2022
Resolved 4 August 2022
Resolution: Vessel provided log showing completed inspection.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 July 2022
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Port side shut off valve was found with the handle disconnected. Corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2022
Resolved 21 July 2022
Resolution: Corrected during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 May 2021
Resolved
Masthead and stern lights inoperable. Demonstrate proper operation of navigation lights.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 27 May 2021
Resolved 27 May 2021
Resolution: Vessel replaced bulbs on both inoperable navigation lights and demonstrated operation by the end of inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 May 2021
Resolved
Stern light arc of visibilty is obstructed by mast for anchor light. Mount stern light to show unobstructed arc of visibilty.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 15 June 2021
Resolution: Vessel relocated stern light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2021
Resolved
Provide correct battery for ring life buoy water light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 3 June 2021
Resolution: Vessel provided correct battery.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2021
Resolved
Vessel missing (01) 40-B:C portable fire extinguisher. Provide extinguisher to ensure vessel is equipped with (1) 10-B:C and (4) 40-B:C extinguishers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 15 June 2021
Resolution: Vessel provided new extinguisher and bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2021
Resolved
Generator rear seal leaking. Repair or provide repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 15 June 2021
Resolution: Vessel cleaned rear seal area. Leak is minimal. Vessel to replace generator within next year.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2021
Resolved
Fuel oil hoses oil soaked due to leaking generator rear seal. Replace with hoses that meet SAE J-1942 or USCG type.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 15 June 2021
Resolution: Vessel steam cleaned hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2021
Resolved
Exhaust cooling water hoses for generator chaffing. Replace as needed and protect from chaffing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 15 June 2021
Resolution: Vessel replaced hose and provided chaffing gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 May 2021
Resolved
Fuel pump for generator not properly secured. Mount in place.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 15 June 2021
Resolution: Vessel built a mounting bracket and secured fuel pump.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 May 2021
Resolved
Permanent extension cord found powering second refrigerator in salon. Remove and provide proper permanent electrical wiring installation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 3 June 2021
Resolution: Vessel provided permanent wiring installation.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 July 2020
Resolved
Prove proper operation of starboard engine shutdown.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2020
Resolution: Engine shutdown system worked as designed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2020
Resolved
Provide a written letter to be exempted from current fire fighting requriments & 46CFR181.425
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2020
Resolution: Letter received.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 July 2020
Resolved
Repair engine room dampers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2020
Resolution: Engine room dampers repaired.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 July 2020
Resolved
Provide speaker in salon for PA system.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2020
Resolution: PA speaker for salon is working properly.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 July 2020
Resolved
Provide current FCC safety certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2020
Resolution: Current FCC Safety certificate received.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2020
Resolved
Log EPRIB,lifesaving, & firefighting maintenance.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2020
Resolution: Maintenance logs updated.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 July 2020
Resolved
Provide FCC operators permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2020
Resolution: Operator's permit received.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 April 2019
Resolved
Provide MMC for Master.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2019
Resolution: MMC provided.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 25 April 2019
Resolved
Provide pre-employment drug testing for crew.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2019
Resolution: Test provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2019
Resolved
Provide 02 additional childs life jackets.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 2 May 2019
Resolution: Life jackets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2019
Resolved
Provide a life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 May 2019
Resolution: Life ring provided. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2019
Resolved
Provide a nozzle for the fire hose.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 2 May 2019
Resolution: Nozzle provided, all sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 April 2019
Resolved
Provide check valve in galley bilge pipe.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 May 2019
Resolution: Installed new check valve, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 February 2019
Resolved
Vessel is past the COI anniversary due date. Vessel is prohibited from carrying passengers for hire until the COI insppection is complete.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2019
Resolved 2 May 2019
Resolution: Vessel completed COI inspection.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 February 2019
Resolved
Label remote fuel shutoff valves.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2019
Resolution: Valves labeled.
Lifesaving › Inflatable Liferafts › Servicing
Issued 15 May 2018
Resolved
Provide liferaft certificate for annual service.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Resolution: Liferaft serviced.
Lifesaving › Hand Flares › Expired
Issued 15 May 2018
Resolved
Replace flares by the end of June 2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 14 June 2018
Resolution: Flares renewed.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 15 May 2018
Resolved
Re-pack P/S shafts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Resolution: Replaced shaft packing.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2018
Resolved
Remove dead end wires fwd E/R bulkhead.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Resolution: Deadend wires removed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 May 2018
Resolved
Double clamp port engine cooling line.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Resolution: Cooling hose doubled clamped.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 May 2018
Resolved
Re-mark stbd lifejacket storage.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Resolution: Life jacket storage marked.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 May 2018
Resolved
Provide light cover for galley and E/R lights.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Resolution: Light cover provided.
Stability › Weathertight Integrity › General
Issued 15 May 2018
Resolved
provide missing securing arm on fwd hatch.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Resolution: Securing arm installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 June 2017
Resolved
Connect GPS to VHF-DSC radio.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 11 August 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 20 June 2017
Resolved
Replace valve handles on P/S marine toilets.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 11 August 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 17 May 2017
Resolved
Install VHF-DSC class D radio.
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 20 June 2017
Resolution: VHF-DSC radio installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 May 2017
Resolved
Provide 04 additional adult lifejackets.
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 11 August 2017
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 17 May 2017
Resolved
Replace cracked stbd window on the bridge.
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 14 June 2018
Resolution: Window replaced.
Lifesaving › Hand Flares › Storage
Issued 17 May 2017
Resolved
Provide properly marked watertight container for flares.
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 20 June 2017
Resolution: Flares stored in marked watertight container.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 May 2017
Resolved
Properly mark stbd storage of lifejackets.
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 20 June 2017
Resolution: Lifejacket storage marked.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 19 April 2017
Resolved
Install reinforced exhaust hose on generator & remove leaking elbow.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 17 May 2017
Resolution: Exhaust hose renewed and elbow was no longer leaking.
Engineering › Bilge Water Management System › Pump
Issued 19 April 2017
Resolved
Secure submersible bilge pump in bait compartment
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 17 May 2017
Resolution: Bilge pump secured.
Communications › Radio Communications › EPIRB
Issued 29 February 2016
Resolved
Prior to ops >3NM, ensure FCC EPIRB registration matches unit onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 29 February 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 February 2016
Resolved
Provide negative pre-employment test results for two crewmembers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 22 March 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 February 2016
Resolved
Raise anchor light to allow 360 degree visibility
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 19 April 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 February 2016
Resolved
Secure generator diesel engine water temp unit
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 22 March 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 February 2016
Resolved
Install (02) machinery belt guards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 19 April 2016
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 29 February 2016
Resolved
Repair starboard engine tach
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 22 March 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 February 2016
Resolved
Repair or replace cover of E/R breaker panel
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 19 April 2016
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 29 February 2016
Resolved
Replace ground terminal in generator switch box
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 19 April 2016