MAURY USCG vessel records Sign in
← All vessels

GODEWIND

GODEWIND is a 1977 freight ship. The Coast Guard has recorded 8 inspections since 1996, most recently in February 2024, along with 5 deficiencies and 1 operational control.

Records from 1996 to 2024. Most recent: inspection, 6 February 2024.

Built
1977
Last inspected
6 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7528556 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
435292
Flag
CAYMAN ISLANDS
—
Maury page id
psix-435292

Inspections, by type

…with no type recorded7
Years with a record 4 calendar years (1996–2024)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3622 - Regulatory (Subpart C or D), Gross Ton
1599 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

6 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861657
4 January 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 539555
2 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 406392
29 January 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 489009
9 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 484131
19 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 520571
11 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387978
3 January 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 386983

Deficiency record · 5

Engineering
Issued 2 August 1997 Resolved
MAIN ENGINE LEAK COLLECTION PIPE IS LEAKING. REPAIR / REPLACE LEAK COLLECTION PIPE.
Condition: Unknown
Due 2 September 1997
Resolved 6 February 2024
Resolution: Closing Def from Misle activity # 406392. Vessel has not had an inspection in the U.S since 1997
Lifesaving
Issued 2 August 1997 Resolved
RETRO TAPE ON LIFEBOATS AND PFD EXTREMELY WEATHERED AND WORN. REPLACE RETRO TAPE ON LIFEBOATS AND PFD'S AS NEEDED.
Condition: Unknown
Due 2 September 1997
Resolved 6 February 2024
Resolution: Closing Def from Misle activity # 406392. Vessel has not had an inspection in the U.S since 1997
Fire Fighting
Issued 2 August 1997 Resolved
FIRE PLAN IS WRITTEN IN LANGUAGE NOT COMMON TO CREW OR OFFICERS. PROVIDE FIRE PLAN IN LANGUAGE UNDERSTOOD BY CREW AND UPDATE PLAN TO COMPLY WITH SOLAS 74 CH II REG 20.
Condition: Unknown
Due 2 September 1997
Resolved 6 February 2024
Resolution: Closing Def from Misle activity # 406392. Vessel has not had an inspection in the U.S since 1997
Engineering
Issued 2 August 1997 Resolved
CORRECT LEAK IN MAIN ENGINE INJECTION PUMP.
Condition: Unknown
Due 2 September 1997
Resolved 6 February 2024
Resolution: Closing Def from Misle activity # 406392. Vessel has not had an inspection in the U.S since 1997
Lifesaving
Issued 2 August 1997 Resolved
REPLACE LIFE RING ON PORTSIDE BRIDGE WING WITH EQUIPMENT IAW SOLAS 74 CHIIIREG 19.2.
Condition: Unknown
Due 2 September 1997
Resolved 6 February 2024
Resolution: Closing Def from Misle activity # 406392. Vessel has not had an inspection in the U.S since 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.