Records from 1985 to 2012. Most recent: inspection, 13 July 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
13 July 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4377666
20 January 2011
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3929494
13 March 2009
Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3432816
7 August 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3291468
18 April 2008
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3186848
13 July 2007
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2993669
20 June 2006
Examination of Repairs · Damage Survey · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2685607
27 March 2006
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2610140
28 June 2005
Deficiency Check · Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2415406
27 December 2004
Damage Survey
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2265081
1 September 2004
Deficiency Check
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2223656
29 July 2004
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2150456
4 June 2004
Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2093645
14 May 2003
COI Inspection · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1793334
26 August 1999
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1455780
19 November 1998
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1386369
8 May 1998
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 797843
31 March 1998
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 787059
17 March 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1109643
13 May 1997
Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1390509
18 March 1997
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1028354
30 October 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1096883
2 May 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085674
23 January 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186892
18 April 1995
COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 782915
18 April 1995
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871042
13 April 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871044
23 May 1994
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175354
12 April 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 865106
6 May 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1153639
22 April 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266754
15 April 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1267099
5 June 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244674
23 April 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908411
6 November 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232533
6 April 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218099
20 April 1989
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891972
20 April 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1352909
16 February 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1345122
25 April 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339559
7 May 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019663
27 April 1987
Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1207120
7 May 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309176
20 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289601
25 April 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289942
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 August 2008
Resolved
Provide copy of updated Drug Consortium enrollment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 19 October 2008
Resolution: Received updated copy of Drug Consortium enrollment.
Documentation › Certificates/Documents › Stability Letter
Issued 7 August 2008
Resolved
Place Stability letter on board
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 13 August 2008
Resolution: Stability letter placed on board, all sat.
Communications › Public Address System › Loudspeaker
Issued 7 August 2008
Resolved
Prove proper operation of public address system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 13 August 2008
Resolution: Tested the public address system, all sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 August 2008
Resolved
Provide updated copy of Light List and Coast Pilot.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 13 August 2008
Resolution: Updated copy of Light List and the Coast Pilot had been placed on board.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Operation Controls
Issued 7 August 2008
Resolved
Provide annual servicing certificate of fixed fire fighting system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 19 September 2008
Resolution: Examined fixed fire fighting system had been serviced and tested engine shut down, all sat
Engineering › Steering Gear System › Linkage
Issued 7 August 2008
Resolved
Tighten portside tiller arm which is loose
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 19 September 2008
Resolution: Portside tiller arm properly fit together and tightened, all sat.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 7 August 2008
Resolved
Prove proper operation of port and starboard shaft packing glands.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 19 September 2008
Resolution: Port and starboard shaft packing glands tightened, working properly, all sat.
Construction/Loadline › Hull › Hull Plating
Issued 27 July 2007
Resolved
REPAIR CRACKED PLANKING ON STBD SIDE 18 INCHES ABOVE WATER LINE PRIOR TO CARRYING PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2007
Resolution: HULL PLATING WAS REPAIRED AND PROPERLY SEALED.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 July 2007
Resolved
PROVE PROPER OPERATION OF RADAR.
Action required: 705 - Other - as specified
Resolved 27 July 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 July 2007
Resolved
OUTBOARD GENERATOR NOT TO BE UTILIZED UNTILL PROPER FIRE SYSTEM SHUTDOWN CAN BE PROVEN.
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 27 July 2007
Resolution: When wire was removed simulating pressure drop in bottle both MDE''s and generator secured. Test SAT
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 July 2007
Resolved
REPLACE INDENTIFIED HOSES ON BILGE SYSTEM.
Action required: 705 - Other - as specified
Resolved 5 September 2007
Resolution: HOSES WERE REPLACED WITH AN APPROVED TYPE HOSE WITH METAL REINFORCMENT.
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 13 July 2007
Resolved
PROVIDE MEANS OF OBTAINING PASSENGER COUNT ASHORE.
Action required: 705 - Other - as specified
Resolved 5 September 2007
Resolution: MAILBOX POSTED ON PEIR NEXT TO VESSEL BERTH.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 13 July 2007
Resolved
PROVIDE PORTABLE BILGE PUMP.
Action required: 705 - Other - as specified
Resolved 27 July 2007
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 20 June 2006
Resolved
Crew not enrolled in drug testing consortium according to 46 CFR 16.201
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2007
Documentation › Certificates/Documents › FCC SSL
Issued 20 June 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 27 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 20 June 2006
Resolved
Life jackets were stored and not ready for inspection. 835 issued to provide at least 155 adult lifejackets.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2006
Resolution: 158 adult life jackets in satisfactory condition provided.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 June 2006
Resolved
Vsl. did not have (2) battery operated lanterns.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 21 July 2006
Resolution: (2) portable flashlights provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 June 2006
Resolved
Bilge high level alarm in crash bulkhead compartment did not operate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 21 July 2006
Resolution: Tested bilge high level alarm in crash compartment and verified satisfactory operation.
Construction/Loadline › Structures › Scupper
Issued 20 June 2006
Resolved
Drain guard on port side scupper missing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 21 July 2006
Resolution: Drain guard replaced on port side scupper.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 June 2006
Resolved
Life buoy did not have markings as required.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 21 July 2006
Resolution: Proper markings provided on life buoy.
Engineering › Bilge Water Management System › Pump
Issued 20 June 2006
Resolved
Bilge pump did not operate properly on port side of E/R.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 21 July 2006
Resolution: Bilge pump in E/R replaced w/ new JABSCO pump and demonstrated to operate properly.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 June 2006
Resolved
Required repair proposal to be submitted for fractured planking between main deck and deck rail at transom.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2006
Resolved 21 July 2006
Resolution: Repair proposal submitted via fax previously and approved. Repairs verified to be satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 June 2006
Resolved
Fixed C02 system lacked proper servicing. B-I extinguisher also lacked proper servicing.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2006
Resolution: Witnessed servicing of CO2 fixed system and verified servicing certificate on B-I extinguisher.
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 June 2006
Resolved
Magnetic compass did not illuminate properly. Restricted from engaging in night ops until rectified.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 July 2006
Resolution: Magnetic compass demonstrated to illuminate properly.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 20 June 2006
Resolved
First aid kit did not have eye wash and aspiring w/ valid dates.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 21 July 2006
Resolution: Aspirin/Eye wash provided w/ valid dates.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 June 2006
Resolved
Life jacket compartments were not labeled properly with size and quantity of each size.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 June 2006
Resolved
Bilge high level alarms were not labeled properly w/ corresponding space properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 27 July 2007
Personnel › Certificates/Documents/Licenses › PIC
Issued 20 June 2006
Resolved
Vessel did not have letter designating senior deck hand on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 5 September 2007
Documentation › Certificates/Documents › Stability Letter
Issued 20 June 2006
Resolved
Vsl. did not have stability letter posted on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 5 September 2007
Resolution: kept on bridge in folder
Fire Fighting › Fire Hoses › Connections
Issued 20 June 2006
Resolved
Vsl. did not have proper nozzle for hose, capable of alternating spray pattern from stream to spread.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 20 August 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 June 2006
Resolved
Master w/ valid license was not present for underway check ride and drills.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 June 2005
Resolved
SHOW EVIDENCE OF CURRENT ENROLLMENT IN DRUG/ALCOHOL PROGRAM.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 26 September 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 June 2005
Resolved
REMOVE ALL OILY WASTE FROM BILGE.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 26 September 2005
Personnel › Training › First Aid/CPR
Issued 28 June 2005
Resolved
SHOW EVIDENCE OF CURRENT FIRST AID/CPR TRAINING FOR MINIMUM OF 50% OF CREW.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 26 September 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 28 June 2005
Resolved
SHOW EVIDENCE OF MARINE RADIO OPERATOR PERMIT FOR VESSEL OPERATOR.
Action required: 705 - Other - as specified
Due 28 July 2005
Resolved 26 September 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2004
Resolved
Update electrical connections for PA in pilot house, making them more permanent.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 1 September 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 July 2004
Resolved
Double clamp raw water intake near keel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 1 September 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 July 2004
Resolved
Show evidence of annual servicing of fixed firefighting system, engine room heat detector and fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 1 September 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 July 2004
Resolved
Replace and make permanent rail section on upper deck, starboard near pilot house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 1 September 2004
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 29 July 2004
Resolved
Show evidence of vessel operator having valid marine radio operator permit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 19 October 2004
Resolution: VESSEL IS OUT OF SERVICE FOR THE SEASON. WILL NEED TO OBTAIN VALID MROP AT BEGINNING OF 2005 SEASON.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 May 2003
Resolved
Conduct satisfactory fire drill. LEGACY COMPONENT DESC: Fire
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 29 July 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 May 2003
Resolved
Conduct satisfactory man overboard drill.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 29 July 2004
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 14 May 2003
Resolved
Provide evidence of proper drug testing program. LEGACY COMPONENT DESC: Proof of Consortium Enrollment (DAPI)
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 29 July 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 14 May 2003
Resolved
Show evidence that vessel master has a valid FCC marine radio operator permit.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 19 October 2004
Resolution: VESSEL IS OUT OF SERVICE FOR THE SEASON. WILL NEED TO OBTAIN EVIDENCE OF MROP AT BEGINNING OF 2005 SEASON.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 14 May 2003
Resolved
Install suitable closure devices for all ventilation ports to engine room.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 29 July 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 14 May 2003
Resolved
Replace fifteen (15) adult PFD's. Until these are replaced, the number of passengers shall be reduced by an equal amount.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 19 June 2003
Construction/Loadline
Issued 26 August 1999
Resolved
Provide visual bilge alarm indicators per 46 CFR 182.530(a).
Condition: Unknown
Due 26 August 1999
Resolved 19 November 1999
Lifesaving
Issued 26 August 1999
Resolved
Replace unservicable buoyant apparatus for 46 persons. Do not carry passengers for hire beyond one mile from shore until item is cleared to thesatisfaction of the attending marine inspector.
Condition: Unknown
Due 26 September 1999
Resolved 15 May 2003
Resolution: Removed from vessel. No longer needed per route.
Engineering
Issued 26 August 1999
Resolved
Provide approved relief valve for air receiver.
Condition: Unknown
Due 26 September 1999
Resolved 15 May 2003
Documentation
Issued 26 August 1999
Resolved
Provide FCC Safety Radiotelephone Certificate per 47 CFR 80. Do not carry passengers for hire beyond 1000 ft from shore until item is cleared to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 26 August 1999
Resolved 15 May 2003
Fire Fighting
Issued 26 August 1999
Resolved
Repair engine room fire alarm per 46 CFR 181.400(c). Do not carry passengers for hire until item is repaired.
Condition: Unknown
Due 26 September 1999
Resolved 26 August 1999
Fire Fighting
Issued 26 August 1999
Resolved
Provide 2 inch extensions with caps on each CO2 distribution CO2 distribution line at each nozzle per 46 CFR 181.410(d)(2)._x001C_
Condition: Unknown
Due 26 September 1999
Resolved 15 May 2003
Construction/Loadline
Issued 19 November 1998
Resolved
Worklist must be completed prior to the carrying of passengers.
Condition: Unknown
Due 13 August 1999
Resolved 27 August 1999
Engineering
Issued 8 May 1998
Resolved
Replace muffler on generator wet exhaust.
Condition: Unknown
Due 29 May 1998
Resolved 2 September 1998
Engineering
Issued 8 May 1998
Resolved
Make temporary repair to generator wet exhaust prior to carrying passengers.
Condition: Unknown
Due 8 May 1998
Resolved 2 September 1998
Engineering
Issued 17 March 1998
Resolved
PROVIDE A MACHINERY GUARD FOR THE PORT MAIN ENGINE.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Navigation
Issued 17 March 1998
Resolved
PROVIDE A PROPER ANCHOR LIGHT.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Documentation
Issued 17 March 1998
Resolved
PROVIDE COPY OF OPERATOR'S LICENSE.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Navigation
Issued 17 March 1998
Resolved
PROVIDE DEVIATION CARD.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Lifesaving
Issued 17 March 1998
Resolved
CONDUCT A MAN OVERBOARD TEST UNDERWAY.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Lifesaving
Issued 17 March 1998
Resolved
PROVIDE REFLECTIVE TAPE FOR LIFERINGS AND BUOYANT APPARATUSES.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Lifesaving
Issued 17 March 1998
Resolved
PROVIDE 2 ADULT PFD'S. PASSENGERS LIMITED TO 201 UNTIL COMPLETE.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Documentation
Issued 17 March 1998
Resolved
PROVIDE EMERGENCY FUEL SHUTOFF SIGNS WITH DIRECTION OF OPERATION FOR BOTH SHUTOFFS.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Documentation
Issued 17 March 1998
Resolved
PROVIDE A MARPOL PLACARD.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Construction/Loadline
Issued 17 March 1998
Resolved
SEAL ALL OPENINGS IN E/R BULKHEADS.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Electrical
Issued 17 March 1998
Resolved
MOUNT ELECTRICAL JUCTION BOX, STARBOARD SIDE OF ENGINE ROOM.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Documentation
Issued 17 March 1998
Resolved
PROVIDE THE FOLLOWING INFORMATION FOR THE DRUG PROGRAM: (A) 5 TYPES OF TESTING (B) DRUGS TESTED FOR
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Construction/Loadline
Issued 17 March 1998
Resolved
PROVIDE BILGE FOOT STRAINERS FOR THE BILGE SUCTIONS IN THE LAZARETTE AND THE FORWARD COMPARTMENT.
Condition: Unknown
Due 17 April 1998
Resolved 20 November 1998
Engineering
Issued 6 May 1993
Resolved
PERFORM OPERATIONAL TEST OF STBD MAIN ENGINE. THIS REQUIREMENT TO BE COMPLETED PRIOR TO PLACING VESSEL IN OPERATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Construction/Loadline
Issued 25 April 1985
Resolved
AT NEXT CREDIT DRYDOCK REFASTENSTERNOF THE VESSELUP TO LAST FRAME IN AFT SECTION OF ENGINEROOM. ALSO, REFASTEN THE FORWARD SECTION OF THE VESSEL FORWARD OF THE 17TH FRAME FORWARD OF THE AFTER FRAME IN THE ENGINEROOM.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985