MAURY USCG vessel records
← All vessels

BWM 52

BWM 52 is a 1996 freight barge. The Coast Guard has recorded 33 inspections since 1996, most recently in November 2016, along with 26 deficiencies and 2 operational controls.

Records from 1996 to 2016. Most recent: inspection, 28 November 2016.

Built
1996
Last inspected
28 November 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

435436
Flag
UNITED STATES
Maury page id
psix-435436

Inspections, by type

Years with a record 20 calendar years (1996–2016)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it196 - Regulatory (Subpart C or D), Gross Ton
196 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 33

28 November 2016 Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6048803
11 April 2016 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5852618
15 March 2016 Special · Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5838120
19 May 2015 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5128906
7 August 2014 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4946694
31 July 2014 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4939978
22 August 2013 Administrative Inspection · Periodic Inspection · Cargo Tank Internal
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4693368
9 August 2012 MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4406144
21 May 2010 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3743580
17 May 2010 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3740676
24 March 2009 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3439108
20 March 2009 Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3434885
10 December 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3377514
27 March 2008 Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3172095
29 May 2007 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2945295
13 April 2006 Deficiency Check · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2622233
26 September 2005 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2496397
16 May 2005 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2359226
15 March 2004 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2022683
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2007780
25 August 2003 Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1886964
4 June 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1626323
5 April 2002 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1601692
18 April 2001 Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1439190
9 January 2001 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1057526
28 November 2000 Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1059195
22 May 2000 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1435049
2 February 1999 Hull Examination · Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1472672
6 March 1998 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 775439
6 March 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118771
25 February 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374881
19 March 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 886349
6 March 1996 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377610

Deficiency record · 26

Construction/Loadline › Hull › Bottom Plating
Issued 11 April 2016 Resolved
Failure to compelte credit dry-dock.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2016
Resolved 30 May 2017
Resolution: Vessel Surrendered COI and convedrted to deck barge
Construction/Loadline › Hull › Bottom Plating
Issued 23 March 2016 Resolved
The vessel has been granted a dry-dock extension and shall not conduct operations until dry-dock can be completed on May 11, 2016.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2016
Resolved 30 May 2017
Resolution: Vessel Surrendered COI and convedrted to deck barge
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 August 2014 Resolved
Replace corroded longitudinals in the rake.
Action required: 705 - Other - as specified
Due 21 August 2014
Resolved 4 September 2014
Resolution: Replaced all need longitudinals
Construction/Loadline › Hull › Bracket
Issued 7 August 2014 Resolved
Replace tripping brackets in voids as marked.
Action required: 705 - Other - as specified
Due 21 August 2014
Resolved 18 September 2014
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 7 August 2014 Resolved
Replace corroded stanchion as marked
Action required: 705 - Other - as specified
Due 21 August 2014
Resolved 4 September 2014
Construction/Loadline › Hull › Weld
Issued 7 August 2014 Resolved
Grind and reweld broken welds as marked.
Action required: 705 - Other - as specified
Due 21 August 2014
Resolved 4 September 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 July 2014 Resolved
Vessel is overdue for ISE (March 2014), no cargo operations permitted prior to completing ISE to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2014
Resolution: Annual and ISE conducted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2010 Resolved
Vessel prohibited from conducting cargo operationsuntil a satisfactory COI exam is completed. Vessel was overdue for COI exam as of 05/16/2010.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2010
Resolution: Completed satisfactory COI inspection.
Construction/Loadline › Hull › Double Hull
Issued 20 March 2009 Resolved
Found pin hole in the stern box in way of the #2 STBD side wing tank bulkhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 20 March 2009
Resolution: Welded and tested.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 20 March 2009 Resolved
Vessel Name and Draft marks need to be painted.
Action required: 705 - Other - as specified
Resolved 20 March 2009
Resolution: Vessel name and Draft marks were painted.
Construction/Loadline › Hull › Double Hull
Issued 20 March 2009 Resolved
Found 02 fractures in bow rake in way of the starboard #1 wing tank bulkhead. Permanent repairs are to be completed to satisfaction of the attending Marine Safety Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 24 March 2009
Resolution: Repairs and satisfactory air test completed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 May 2007 Resolved
Remove the old wasted ladder and install a new one in the port side hatch to the bow rake.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 5 June 2007
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 16 May 2005 Resolved
Mark vsl name and home port in contrasting colors on the stern.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 26 September 2005
Construction/Loadline › Structures › Manhole
Issued 16 May 2005 Resolved
Replace broken t-bar for bow void hatch.
Due 16 June 2005
Resolved 16 May 2005
Construction/Loadline › Structures › Manhole
Issued 16 May 2005 Resolved
Gouge and weld broken welds on #2 port hatch.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 26 September 2005
Construction/Loadline › Structures › Manhole
Issued 16 May 2005 Resolved
Replace missing/broken shackle on stern void and #2 starboard hatches.
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 26 September 2005
Operations/Management
Issued 15 March 2004 Resolved
Schedule internal structural exam prior to 22 Mar 04.
Action required: 705 - Other - as specified
Due 22 March 2004
Resolved 17 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 27 August 2003 Resolved
Renew gangway warning sign on stbd side.
Action required: 705 - Other - as specified
Due 27 September 2003
Resolved 25 November 2003
Construction/Loadline › Structures
Issued 27 August 2003 Resolved
Renew gaskets for all manholes. LEGACY COMPONENT DESC: Manhole
Action required: 705 - Other - as specified
Due 27 September 2003
Resolved 25 November 2003
Construction/Loadline
Issued 18 April 2001 Resolved
REPAIR CRACKED WELDS ON INTERNAL FRAMING. SEE MINS FOR DEATILS.
Condition: Unknown
Due 9 May 2001
Resolved 10 May 2001
Deck/Cargo
Issued 28 November 2000 Resolved
MAKE PERMANENT REPAIRS TO ALL DAMAGED DRAIN PLUGS/COLLARS AT MAIN DECK AND_x001C_BETWEEN CARGO BAYS, ALL FRACTURES ON CARGO BAY STIFFENERS, AND ALL SHARP_x001C_ EDGES ALONG UPPER CARGO BAY FLANGE.
Condition: Unknown
Due 28 November 2000
Resolved 28 November 2000
Construction/Loadline
Issued 22 May 2000 Resolved
PROVE WATERTIGHT INTEGRITY OF ALL VOID HATCH COVERS.
Condition: Unknown
Due 24 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 22 May 2000 Resolved
PAINT DRAFT MARKS & NAME OF VESSEL.
Condition: Unknown
Due 24 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 2 February 1999 Resolved
PAINT DRAFT MARKS AND VESSEL'S NAME.
Condition: Unknown
Due 5 February 1999
Resolved 8 February 1999
Construction/Loadline
Issued 2 February 1999 Resolved
PROVIDE AND INSTALL FIVE (5) DECK HATCH COVER GASKETS.
Condition: Unknown
Due 5 February 1999
Resolved 8 February 1999
Documentation
Issued 6 March 1996 Resolved
PROVIDE PROOF OF APPROVAL OF VESSEL RESPONSE PLAN TO COGNIZANT [name withheld] UNTIL REQUIREMENT IS RESOLVED/CLEARED.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.