MAURY USCG vessel records Sign in
← All vessels

MARCOS DIAS

MARCOS DIAS is a 1995 freight ship. The Coast Guard has recorded 17 inspections since 1997, most recently in May 2005, along with 54 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 1997 to 2005. Most recent: inspection, 24 May 2005.

Built
1995
Last inspected
24 May 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9070565 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
435455
Flag
BRAZIL
—
Maury page id
psix-435455

Inspections, by type

…with no type recorded11
…past their stated due date1
Years with a record 6 calendar years (1997–2005)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it44529 - Dead Weight, Ton
14405 - Regulatory (Subpart C or D), Net Ton
25929 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

24 May 2005 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2367103
22 May 2005 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2364882
21 May 2005 Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2364067
12 May 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2355949
9 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2354356
7 January 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1977424
2 January 2004 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1973201
7 July 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1838015
25 March 2003 Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1761825
21 March 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1495456
7 January 2002 Type not recorded
No type recorded · GROUP PHILADELPHIA · USCG East District (CGD-E) · Activity 1476013
3 January 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1477820
6 August 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 431352
9 July 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 430083
20 June 1999 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 429903
2 September 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 407374
16 June 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 404625

Deficiency record · 54

Operations/Management › Ballast Water Managment › Sediments
Issued 21 May 2005 No resolution recorded
Vessels #3 stbd DWT was contaminated with an oil water mixture. Prior to discharging ballast from #3 DWT, oily water mixture must be cleaned by an approved cleaning agent. Vessel to proceed to international waters and thoroughly clean ballast tank. Class Society representative to submit report attesting to the condition of the #3 DWT prior to entry into a U.S. Port after sailing foreign.
Action required: 705 - Other - as specified
Due 4 June 2005 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance
Issued 2 January 2004 Resolved
VSL'S ECHO DEPTH SOUNDER RECORING DEVICE NOT RECORDING PROPERLY. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2004
Resolved 2 January 2004
Resolution: CORRECTED ON THE SPOT.
Navigation › Electronic Positioning
Issued 2 January 2004 Resolved
VSL'S NAVTEX RECIEVER NOT FUNCTIONING PROPERLY. PRINTER WAS NOT PRODUCING A LEDGIBLE PRINT OUT. VSL IS TO SUBMIT A TECH REPORT PRIOR TO DEPARTURE LEGACY COMPONENT DESC: LORAN C Receiver
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Resolution: Tech Report Recieved
Navigation › Collision/Grounding Avoidance
Issued 2 January 2004 Resolved
VSL'S 3CM AND 10CM RADARS ARE NOT FUNTIONIG PROPERLY. VESSEL IS REQUIRED TO SUBMIT A TECH REPORT PRIOR TO DEPARTURE FROM PORT LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Resolution: Tech Report Recieved
Electrical › Electric Generation Source (service)
Issued 2 January 2004 Resolved
DUE TO A FAILURE OF THE VSL'S #2 SSS, VSL HAS A TEMPORARY GENERATOR INSTALLED ON THE PORT BRIDGE WING. VSL'S CLASSIFICATION SOCIETY HAS YET TO APPROVE THE TEMPORARY INSTALATION AND IS REQUIRED TO ATTEND VESSEL PRIOR TO IT'S DEPARTURE FROM PORT.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Resolution: Class addressed issue and submitted a work list for the vessel.
Operations/Management
Issued 2 January 2004 Resolved
VSL HAS 20 PLUS 55 GALLON DRUMS FILLED WITH GARBAGE LITERING THE POOPDECK. DUE TO IMPROPER GARBAGE SEGREGATION THROUGHOUT THE VSL THEY ARE TO DISCHARGE ALL GARBAGE ASHORE PRIOR TO DEPARTURE AND SUBMIT GARBAGE RECIEPT TO USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Resolution: Garbage receipt received
Fire Fighting › Means of Escape
Issued 2 January 2004 Resolved
VESSELS HAS TWO EMERGENCY ESCAPE TRUNKS IN THE E/R. DOORS TO BOTH OF THESE ESCAPES DO NOT LATCH COMPLETELY. VESSEL IS TO REPAIR/REPACE PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Doorways
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2004
Resolution: Class attested to the proper operation of the doors.
Engineering › Fuel Oil Service System
Issued 2 January 2004 Resolved
LAGGING AROUND OIL PURIFIERS IN ENGINE IS OIL SOAKED. VESSEL IS TO RENEW/REPLACE LAGGING.
Due 2 February 2004
Resolved 12 January 2004
Resolution: Vessel replaced lagging as per class report
Documentation › Certificates/Documents
Issued 7 July 2003 Resolved
CARGO SHIP SAFETY EQUIPMENT CERTIFICATE ON BOARD IS EXPIRED. NEW CERTIFICATE IS TO BE ISSUED @ PHILADELPHIA PRIOR TO SHIPS DEPARTURE. SOLAS 74/78, CH I, REG.14.(a) LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2003
Resolution: RECIEVED FAXED CERTIFICATE CLEARING THE DIFICIENCIE. NOTE THAT THE CERTIFICATE IS ONLY VALID UNTIL 31JUL03.
Fire Fighting › Fire Main › Condition
Issued 7 July 2003 Resolved
LEAK AND SOFT PATCH ON FIRE MAIN PIPE GOING INTO BOATSWAINS HOLD. PIPE IS PERMANTLY WELDED TO BULKHEAD AND CANNOT BE EASILY REPAIRED. PERMANENT REPAIRS ARE TO BE MADE TO PIPE. CORRECT PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN. SOLAS 74/78 CH II, REG 21 LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 May 2005
Resolution: Fire main repaired.
Navigation › Piloting/Steering
Issued 25 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 7 July 2003
Resolution: LOOKED AT TECHNICIAN REPORT AN THEN COMPARED MAGNETIC AN GYRO COMPASSES AN DEVIATION WAS WITHIN TOLERANCE
Documentation › Certificates/Documents
Issued 25 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2003
Resolution: VESSEL FAXED COPY OF COFR WITH SHIPS STAMP AND CAPTAINS SIGNATURE TO MSO PHILADELPHIA, THE ABOVE DEFICIENCY CLEARED.
Construction/Loadline › Markings
Issued 25 March 2003 Resolved
LOADLINE IS NOT MARKED IN CONTRASTING COLOR TO THE HULL. VIOLATION OF ICLL 66. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: MSO PHILADELPHIA CONDUCTED DEFICIENCY FOLLOW-UP. VESSEL MARKED LOADLINES IN CONTRASTING COLORS. DEFICIENCY CLEARED.
Fire Fighting › Fire Hydrants
Issued 25 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 25 April 2003
Resolved 7 July 2003
Resolution: CORRECTED LEAKS, GASKETS HAD BEEN REPLACED.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 25 March 2003 Resolved
CREW AND HOSPITAL SPACE TOLIETS DO NOT WORK DUE TO LOW AMOUNT OF WATER ONBOARD. VIOLATION OF ILO 147. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Toilet
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: MSO PHILADELPHIA CONDUCTED DEFICIENCY FOLLOW-UP. THE VESSEL RECIEVED WATER AND PLACED TOLIETS BACK IN SERVICE. DEFICIENCY CORRECTED
Lifesaving › Lifeboat Equipment
Issued 25 March 2003 Resolved
VESSEL MISSING (02) TIN OPENER'S FOR THEIR LIFEBOAT. VIOLATION OF SOLAS 74/78 CH. III REG 41.8.23. CORRECT PRIOR TO DEPARTURE LEGACY COMPONENT DESC: Tin-opener
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: MSO PHILADELPHIA CONDUCTED DEFICIENCY FOLLOW-UP. VESSEL RECIEVED TWO TIN OPENERS. CLEARED DEFICIENCY.
Lifesaving › Lifeboat Equipment
Issued 25 March 2003 Resolved
VESSEL MISSING (124) SEA SICKNESS PILLS FOR THEIR LIFEBOAT. VIOLATION OF SOLAS 74/78 CH III REG 41.8.21. CORRECT PRIOR TO DEPARTURE LEGACY COMPONENT DESC: Anti-seasickness Medicine
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: VESSEL FAXED MSO PHILADELPHIA A COPY OF THE PURCHASE RECIEPT, THE ABOVE DEFICIENCY CLEARED.
Lifesaving › Lifeboat Equipment
Issued 25 March 2003 Resolved
VESSEL MISSING (08) FOOD RATIONS FOR THEIR LIFEBOAT. VIOLATION OF SOLAS 74/78 CH III REG 41.8.12. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: MSO PHILADELPHIA CONDUCTED DEFICIENCY FOLLOW-UP. VESSEL PURCHASED (08) RATIONS. DEFICIENCY CLEARED.
Fire Fighting › Fire Hydrants
Issued 25 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 25 April 2003
Resolved 7 July 2003
Resolution: CORRECTED NO LEAKS TO BE FOUND
Fire Fighting › Fire Main
Issued 25 March 2003 Resolved
EXPANSION COUPLER'S ON FIRE MAIN FOUND TO BE LEAKING; LOCATED ON THE STARBOARD SIDE BETWEEN #2 & #3 CARGO HOLDS AND BETWEEN #4 & #5 CARGO HOLDS. VIOLATION OF SOLAS 74/78 CH II-2 REG4. CORRECT WITHIN 30 DAYS LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 25 April 2003
Resolved 7 July 2003
Resolution: CORRECTED, NO LEAKS FOUND
Electrical › Lighting (service)
Issued 25 March 2003 Resolved
PROTECTIVE GLASS DOMES/GLOBES MISSING FROM LIGHT FIXTURES ON WEATHER DECK, (01) NEAR THE BOW & (01) ON THE FANTAIL. VIOLATION OF SOLAS 74/78 CH II-1/45.1.3. CORRECT PRIOR TO NEXT US PORT. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 7 July 2003
Resolution: CORRECTED, ALL GLASS DOMES IN PLACE
Documentation › Logs/Records
Issued 25 March 2003 Resolved
GARBAGE RECORD BOOK ENTERIES NOT LOGGED CORRECTLY( GARBAGE TAKEN ASHORE NOT LOGGED BUT RECEIPTS PRESENT) AND RECIEPTS NOT OBTAINED FOR "SOME" OF THE GARBAGE TAKEN ASHORE; THAT WAS ENTERED INTO THEIR LOG. VIOLATION OF MARPOL 73/78 ANNEX V REG 9. TO BE CHECKED FOR CORRECT COMPLIANCE IN 30 DAYS. LEGACY COMPONENT DESC: Garbage Recordkeeping
Condition: Improper/Lack of Maintenance
Due 25 April 2003
Resolved 7 July 2003
Resolution: CORRECTED, ALL RECIEPTS ARE IN PLACE AN CORRESPOND TO GARBAGE LOG ENTRIES.
Pollution Prevention/Response › Prevention Equipment
Issued 25 March 2003 Resolved
OILY WATER- SEPARATOR 15 PPM ALARM FOUND TO BE INOPERABLE. VIOLATION OF MARPOL 73/78 ANNEX 1. CORRECT PRIOR TO DEPARTURE LEGACY COMPONENT DESC: Oily Water Separator (100 ppm)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2003
Resolution: MSO PHILADELPHIA CONDUCTED DEFICIENCY FOLLOW-UP . CLEARED THE ABOVE DEFICIENCY
Deck/Cargo › Ballast
Issued 25 March 2003 Resolved
GATE VALVES FOR WING BALLAST TANKS #2, #3, AND #4, STARBOARD SIDE WERE FOUND TO BE LEAKING. VALVES TO HAVE PACKING RE-PLACED. VIOLATION OF SOLAS 74/78 CH II-1 REG 26. CORRECT WITHIN 30 DAYS. LEGACY COMPONENT DESC: Valves
Condition: Unknown
Due 25 April 2003
Resolved 7 July 2003
Resolution: CORRECTED, NO LEAKS TO BE FOUND
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 3 January 2002 Resolved
SHIPS SERVICE GENERATOR #1 LEAKING FUEL OIL FROM CYLINDER HEAD AREA.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: LEAK REPAIRED.
Navigation
Issued 3 January 2002 Resolved
ECHO DEPTH SOUNDER RECORDER NOT OPERATING. LEGACY COMPONENT DESC: ECHO DEPTH SOUNDER RECORDER
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: TIDAL CURRENT TABLE PURCHASED AND ONBOARD.
Navigation
Issued 3 January 2002 Resolved
SHIP'S COAST PILOT NOT CURRENTLY CORRECTED. LEGACY COMPONENT DESC: PUBLICATIONS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: COAST PILOT CORRECTED.
Navigation
Issued 3 January 2002 Resolved
TIDAL CURRENT TABLES NOT ONBOARD. LEGACY COMPONENT DESC: PUBLICATIONS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: TIDAL CURRENT TABLE PURCHASED AND ONBOARD.
Navigation
Issued 3 January 2002 Resolved
PHILADELPHIA AREA CHARTS NOT CURRENTLY CORRECT. LEGACY COMPONENT DESC: CHARTS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: CHARTS CORRECTED.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 3 January 2002 Resolved
SHIP'S ARPA RADAR INOPERATIVE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2002
Resolution: ARPA RADAR REPAIRED, TECHNICIANS REPORT RECIEVED.
Navigation
Issued 3 January 2002 Resolved
INLAND NAVIGATION RULES NOT ONBOARD. LEGACY COMPONENT DESC: PUBLICATIONS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: INLAND NAVIGATION RULES PURCHASED AND ONBOARD.
Lifesaving › Rescue Boat
Issued 3 January 2002 Resolved
RESCUE BOAT RIGHTING HANDLE ( STARBOARD- FOWARD ) IS BROKEN.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 21 March 2002
Resolved 21 March 2002
Resolution: RESCUE BOAT RIDING HANDLE WAS REPLACED.
Lifesaving
Issued 3 January 2002 Resolved
LIFEJACKET LOCKER ( MAIN DECK, FOWARD, PORT SIDE ) UNABLE TO BE OPENED. LEGACY COMPONENT DESC: LIFEJACKET LOCKER
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: LIFEJACKET LOCKER REPAIRED, ABLE TO BE OPENED.
Fire Fighting › Fire Main › Valves
Issued 3 January 2002 Resolved
FIREMAIN VALVE BODIES LEAKING ( HATCH #3 PORTSIDE, FIRE STATION #13 PORTSIDE )
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: VALVES REPAIRED.
Fire Fighting › Fire Pumps › Power Source
Issued 3 January 2002 Resolved
SHIPS FIRE PUMP'S POWER SUPPLY CABLES HAVE IMPROPERLY INSTALLED STUFFING TUBES.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 7 January 2002
Resolution: STUFFING TUBES FOR POWER SUPPLY CABLES ON FIRE PUMPS TIGHTENED.
Construction/Loadline
Issued 3 January 2002 Resolved
OPERATORS PLATFORM FOR ANCHOR WINDLASS WASTED. LEGACY COMPONENT DESC: OPERATORS PLATFORM FOR ANCHOR WINDLASS
Action required: 15 - Rectify deficiencies by next port
Resolved 7 January 2002
Resolution: PLATFORM REPAIRED.
Construction/Loadline
Issued 3 January 2002 Resolved
#3 BALLAST TANK VALVE HANDLE WASTED AND READY TO BREAK. LEGACY COMPONENT DESC: BALLAST TANK VALVE HANDLE
Action required: 15 - Rectify deficiencies by next port
Resolved 7 January 2002
Resolution: BALLAST TANK VALVE HANDLE REPLACED.
Operations/Management › FireFighting
Issued 3 January 2002 Resolved
CREW WAS UNABLE TO CONDUCT SATISFACTORY FIRE DRILL. LEGACY COMPONENT DESC: DRILL
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2002
Resolution: CREW CONDUCTED SATISFACTORY FIRE DRILL.
Engineering
Issued 6 August 1999 Resolved
Specific cite: SOLAS 74 (A) 1/ Reg 11._x001C_ Soft patch on leaking pipe flange on discharge line from aux cooling water pump. Vessel to make permanant repair prior to departure and to satisfaction of class.
Condition: Unknown
Due 7 August 1999
Resolved 14 August 1999
Deck/Cargo
Issued 9 July 1999 Resolved
RENEW/REPLACE HYDRAULIC LINES PRIOR TO CONDUCTING CARGO OPERATIONS IN WAY OF CARGO HOLD #3 IN U.S. WATER._x001C_ SOLAS 74 (amended) I/11
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Engineering
Issued 9 July 1999 Resolved
REPAIR TWO STEAM LEAKS SERVING MAIN ENGINE FUEL OIL HEATING SYSTEM._x001C_ SOLAS 74 (amended) I/11
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Engineering
Issued 9 July 1999 Resolved
REPAIR OR REPLACE LEAKING SEALS/PACKING GLANDS FOR MAIN AUXILIARY SEAWATER COOLING PUMPS._x001C_ SOLAS 74 (amended) I/11
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Accommodation/Occupational Safety
Issued 9 July 1999 Resolved
PROVIDE NEW VALVE HANDLE FOR SEWAGE OVERBOARD DISCHARGE VALVE._x001C_ SOLAS (amended) I/11
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Documentation
Issued 9 July 1999 Resolved
PROVIDE UPDATED SAFETY RADIO TELEPHONE CERTIFICATE FROM CLASS SOCIETY._x001C_ SOLAS 74(amended) Annex 3/III/3 & I/12
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Electrical
Issued 9 July 1999 Resolved
PROVE PROPER OPERATION OF AUTOMATIC START VIA BLACKOUT OF EMERGENCY GENERATOR UNDER LOAD. ALSO, TEST NORMAL START VIA COMPRESSED AIR. TO BE COMPLETED TO SATISFACTION OF ATTENDING CLASS SOCIETY SURVEYOR. SOLAS 74(amended) II-1/42.3.1.2
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Construction/Loadline
Issued 9 July 1999 Resolved
PUMP OUT ENGINE ROOM BILGES TO AN APPROVED SHOERSIDE FACILITY. PROVIDE RECIEPTS FROM SHORESIDE FACILITY ACKNOWLEDGING RETRIEVAL OF OIL TO USCG MSOMOBILE._x001C_ SOLAS 74 (amended) II/11
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Engineering
Issued 9 July 1999 Resolved
PROVE PROPER OPERATION OF 15 PPM ALARM AND AUTOMATIC STOPPING DEVICE FOR OILY WATER SEPARATOR TO SATISFACTION OF THE ATTENDING CLASS SOCIETY SURVEYOR._x001C_ MARPOL 73/78 ANNEX I/16(7)
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Engineering
Issued 9 July 1999 Resolved
REPAIR SMALL DIAMETER STEAM LEAK IN ENGINE ROOM._x001C_ SOLAS (amended) I/11
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Engineering
Issued 20 June 1999 Resolved
Vessel's crew was unalbe to test the alarm on the 15 ppm oily water seperator.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Navigation
Issued 20 June 1999 Resolved
Vessel did not have a current set of Tide and Tidal Current Tables.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Electrical
Issued 20 June 1999 Resolved
Cycle guages on the emergency and ships service generators were not operating.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Documentation
Issued 20 June 1999 Resolved
Vessel's Certificate of financial Responsibility was invalidated by NPFC for withdrawing from their P&I club, and also for not providing proof of insurance coverage. Vessel's owners provided the proper information, and the COTP order was withdrew.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Navigation
Issued 16 June 1997 Resolved
PROVE PROPER OPERATION OF STEERING GEAR, AS REQUIRED BY SOLAS 74 CHAP II/REG 29 3.3
Condition: Unknown
Due 18 June 1997
Resolved 24 June 1997
Fire Fighting
Issued 16 June 1997 Resolved
VSL IS MISSING A DISCHARGE NOZZLE FOR THE FIXED FIREFIGHTING SYSTEM IN THE PAINT LOCKER. AS REQUIRED BY SOLAS 74 CHAP II/REG 5 1.14
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997

Ownership record