Inspection history · 66
12 June 2026
MTSA Verification · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8402956
15 April 2026
MTSA Verification · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8350842
21 January 2026
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8299467
15 October 2025
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8253297
23 June 2025
COI Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8165144
5 May 2025
Drydock Exam · Damage Survey · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8129110
4 May 2025
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8140498
23 April 2025
Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8117959
4 April 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8105278
18 March 2025
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8095826
18 March 2025
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8104414
23 January 2025
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8069147
25 October 2024
MTSA Verification · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8024693
2 October 2024
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8013562
19 September 2024
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8006188
19 September 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8013329
21 July 2024
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7941928
31 May 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7961913
30 May 2024
Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7923175
9 May 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7909380
23 February 2024
Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7869281
24 October 2023
Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7813530
26 June 2023
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7724046
12 January 2023
In-Service Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7620486
25 October 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7583011
19 July 2022
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7510815
20 April 2022
Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7432981
13 March 2022
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7414262
26 January 2022
Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7386181
27 October 2021
MTSA Verification · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7340507
11 September 2021
Damage Survey · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7309897
11 September 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7312694
28 July 2021
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7255710
18 June 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7233798
25 March 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7168738
12 January 2021
Internal Structural Exam · Drydock Exam · Re-Inspection · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7123276
2 October 2020
MTSA Verification · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7070141
27 July 2020
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7017296
23 April 2020
Re-Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6941488
29 January 2020
Administrative Inspection · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6897981
23 December 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6878177
6 November 2019
Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6845356
26 July 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6762624
22 July 2019
COI Inspection · Administrative Inspection · Damage Survey · Deficiency Check · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6761969
19 July 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6755460
8 May 2019
Re-Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6673640
13 February 2019
Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6613347
17 January 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6613574
15 November 2018
Re-Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6572696
3 November 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6573731
11 September 2018
Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6538626
17 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6514770
1 August 2018
COI Inspection · Administrative Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6475696
7 May 2018
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6407846
26 February 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6383495
7 February 2018
Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6350922
8 November 2017
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6301452
2 August 2017
MTSA Verification · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6221615
10 May 2017
Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6137914
15 February 2017
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6088635
16 November 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6040846
17 August 2016
Deficiency Check · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5973491
25 July 2016
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5961858
24 June 2016
Examination of Repairs · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5929819
27 May 2016
Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5888197
5 January 2016
Drydock Exam · Internal Structural Exam · Hull Examination · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5791018
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 June 2026
No resolution recorded
Each passenger vessel of less than 500 tons gross must carry at least one rescue boat.
MI noted that the rescue boat on-board was cracked in the Bow allowing water to enter fiberglass and weigh down Rescue boat. Crew to monitor and replaced in kind due next dry-dock.
Action required: 705 - Other - as specified
Due 15 July 2027
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 June 2025
Resolved
PA Systems shall be working. PA system in PAX lounge not operational. make repairs. Pax lounge doors are to remain open.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 July 2025
Resolved 15 July 2025
Resolution: Crew discovered and reattached loose speaker wire.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 25 July 2024
Resolved
The Class 1 watertight door panel red indicator lights are inoperable as required by 46 CFR 78.17-3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 1 August 2024
Resolution: Attended vessel - Cleared def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2024
Resolved
Electrical connections and splices were observed on the "A" and "B" side under the bridge console as required by 46 CFR 111.60-17
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 1 August 2024
Resolution: Attended vessel - Cleared def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2024
Resolved
Numerous power strips and plugs and/or extension cords were found throughout the vessel daisy chaining equipment together. VHF radio under bridge console on the A" side
, Port Side ("A" side forward) in crew lounge area.
Remove all power strips that cannot be proven to be marine grade as required by 46 CFR 110.30-7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 1 August 2024
Resolution: Attended vessel - Cleared def.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 October 2022
Resolved
A PLAN THAT IS APPROVED BY THE MSC IS VALID FOR 5 YEARS FROM THE DATE OF ITS APPROVAL. VESSEL ASP APPROVAL LETTER WAS ISSUED ON 11 SEP 2017.
Action required: 10 - Deficiency Rectified
Resolved 30 November 2022
Resolution: Viewed New ltr
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 August 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #, CLSN: Vsl is broadcasting Invalid Call Sign, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 September 2018
Resolved 30 November 2018
Resolution: Vessel visited by SECJAX personnel, errors cleared, and information sent to NAVCEN.
Engineering › Bilge Water Management System › Not Operational
Issued 2 August 2017
Resolved
Repair or repalace the "A" end bilge high level alarm switch in the rudder room.
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 11 August 2017
Resolution: Crew renewed the high level bilge alarm switch.
Communications › Alarms/Indicators › General Alarm
Issued 2 August 2017
Resolved
Repair or replace all exterior general alrm bells. They were not producing sound when activated.
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 11 August 2017
Resolution: Crew renewed general alarm bells.
Engineering › Bilge Water Management System › Pump
Issued 10 May 2017
Resolved
The crew was unable to pull suction (voids 1A/1B) with the bilge pump nor the secondary fire/bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2017
Resolved 10 May 2017
Resolution: All check valves cleared of debris and operational.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 17 August 2016
Resolved
Ensure proper alignment of embarkation ladder with securing pins.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 18 August 2016
Resolution: The ladder was altered to accommodate the new rub rail and is properly secured with locking pins when placed in the deployed position.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2016
Resolved
Secure dead end wires under "A" side console.
Condition: Improper Installation
Due 24 August 2016
Resolved 18 August 2016
Resolution: Dead end wires were properly secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2016
Resolved
Either remove the portable fans cooling the steering gear motors or find a way to permanently install cooling fans.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 19 August 2016
Resolution: Portable fans were removed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 March 2016
Resolved
(02) ring buoys lights had the wrong style 6 volt battery that was too heavy. Replace batteries iaw waterlight casing instructions.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 1 June 2016
Construction/Loadline › Structures › Door
Issued 8 March 2016
Resolved
Renew gasket for the emergency generator room door.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 1 June 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 8 March 2016
Resolved
The shore tie cable has several breaks in the outer insulation and appears decrepit. Require megger testing of cable, cap for cable end and repairs to outer insulation.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 1 June 2016