MAURY USCG vessel records
← All vessels

JEAN RIBAULT

Built
1996
Last inspected
12 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 June 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF6510
435466
Flag
UNITED STATES
Maury page id
psix-435466

Documentation record

Registered dimensions (L × B × D)153.6 ft × 56.0 ft × 13.0 ft
Registered tonnagegross 497 / net 338
ITC dimensions (L × B × D)153.6 ft × 56.0 ft × 13.0 ft
ITC tonnagegross 1,131 / net 567
BuilderATLANTIC MARINE INC · JACKSONVILLE, FL, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1131 - Convention (Subpart B), Gross Ton
497 - Regulatory (Subpart C or D), Gross Ton
567 - Convention (Subpart B), Net Ton
338 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 66 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 66

12 June 2026 MTSA Verification · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8402956
15 April 2026 MTSA Verification · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8350842
21 January 2026 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8299467
15 October 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8253297
23 June 2025 COI Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8165144
5 May 2025 Drydock Exam · Damage Survey · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8129110
4 May 2025 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8140498
23 April 2025 Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8117959
4 April 2025 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8105278
18 March 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8095826
18 March 2025 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8104414
23 January 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8069147
25 October 2024 MTSA Verification · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8024693
2 October 2024 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8013562
19 September 2024 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8006188
19 September 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8013329
21 July 2024 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7941928
31 May 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7961913
30 May 2024 Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7923175
9 May 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7909380
23 February 2024 Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7869281
24 October 2023 Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7813530
26 June 2023 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7724046
12 January 2023 In-Service Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7620486
25 October 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7583011
19 July 2022 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7510815
20 April 2022 Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7432981
13 March 2022 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7414262
26 January 2022 Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7386181
27 October 2021 MTSA Verification · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7340507
11 September 2021 Damage Survey · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7309897
11 September 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7312694
28 July 2021 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7255710
18 June 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7233798
25 March 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7168738
12 January 2021 Internal Structural Exam · Drydock Exam · Re-Inspection · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7123276
2 October 2020 MTSA Verification · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7070141
27 July 2020 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7017296
23 April 2020 Re-Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6941488
29 January 2020 Administrative Inspection · Re-Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6897981
23 December 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6878177
6 November 2019 Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6845356
26 July 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6762624
22 July 2019 COI Inspection · Administrative Inspection · Damage Survey · Deficiency Check · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6761969
19 July 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6755460
8 May 2019 Re-Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6673640
13 February 2019 Re-Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6613347
17 January 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6613574
15 November 2018 Re-Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6572696
3 November 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6573731
11 September 2018 Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6538626
17 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6514770
1 August 2018 COI Inspection · Administrative Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6475696
7 May 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6407846
26 February 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6383495
7 February 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6350922
8 November 2017 MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6301452
2 August 2017 MTSA Verification · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6221615
10 May 2017 Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6137914
15 February 2017 MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6088635
16 November 2016 MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6040846
17 August 2016 Deficiency Check · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5973491
25 July 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5961858
24 June 2016 Examination of Repairs · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5929819
27 May 2016 Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5888197
5 January 2016 Drydock Exam · Internal Structural Exam · Hull Examination · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5791018

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 June 2026 No resolution recorded
Each passenger vessel of less than 500 tons gross must carry at least one rescue boat. MI noted that the rescue boat on-board was cracked in the Bow allowing water to enter fiberglass and weigh down Rescue boat. Crew to monitor and replaced in kind due next dry-dock.
Action required: 705 - Other - as specified
Due 15 July 2027
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 June 2025 Resolved
PA Systems shall be working. PA system in PAX lounge not operational. make repairs. Pax lounge doors are to remain open.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 July 2025
Resolved 15 July 2025
Resolution: Crew discovered and reattached loose speaker wire.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 25 July 2024 Resolved
The Class 1 watertight door panel red indicator lights are inoperable as required by 46 CFR 78.17-3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 1 August 2024
Resolution: Attended vessel - Cleared def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2024 Resolved
Electrical connections and splices were observed on the "A" and "B" side under the bridge console as required by 46 CFR 111.60-17
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 1 August 2024
Resolution: Attended vessel - Cleared def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2024 Resolved
Numerous power strips and plugs and/or extension cords were found throughout the vessel daisy chaining equipment together. VHF radio under bridge console on the A" side , Port Side ("A" side forward) in crew lounge area. Remove all power strips that cannot be proven to be marine grade as required by 46 CFR 110.30-7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 1 August 2024
Resolution: Attended vessel - Cleared def.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 October 2022 Resolved
A PLAN THAT IS APPROVED BY THE MSC IS VALID FOR 5 YEARS FROM THE DATE OF ITS APPROVAL. VESSEL ASP APPROVAL LETTER WAS ISSUED ON 11 SEP 2017.
Action required: 10 - Deficiency Rectified
Resolved 30 November 2022
Resolution: Viewed New ltr
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 August 2018 Resolved
IMO: Vsl is broadcasting invalid IMO #, CLSN: Vsl is broadcasting Invalid Call Sign, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 September 2018
Resolved 30 November 2018
Resolution: Vessel visited by SECJAX personnel, errors cleared, and information sent to NAVCEN.
Engineering › Bilge Water Management System › Not Operational
Issued 2 August 2017 Resolved
Repair or repalace the "A" end bilge high level alarm switch in the rudder room.
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 11 August 2017
Resolution: Crew renewed the high level bilge alarm switch.
Communications › Alarms/Indicators › General Alarm
Issued 2 August 2017 Resolved
Repair or replace all exterior general alrm bells. They were not producing sound when activated.
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 11 August 2017
Resolution: Crew renewed general alarm bells.
Engineering › Bilge Water Management System › Pump
Issued 10 May 2017 Resolved
The crew was unable to pull suction (voids 1A/1B) with the bilge pump nor the secondary fire/bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2017
Resolved 10 May 2017
Resolution: All check valves cleared of debris and operational.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 17 August 2016 Resolved
Ensure proper alignment of embarkation ladder with securing pins.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 18 August 2016
Resolution: The ladder was altered to accommodate the new rub rail and is properly secured with locking pins when placed in the deployed position.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2016 Resolved
Secure dead end wires under "A" side console.
Condition: Improper Installation
Due 24 August 2016
Resolved 18 August 2016
Resolution: Dead end wires were properly secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2016 Resolved
Either remove the portable fans cooling the steering gear motors or find a way to permanently install cooling fans.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 19 August 2016
Resolution: Portable fans were removed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 March 2016 Resolved
(02) ring buoys lights had the wrong style 6 volt battery that was too heavy. Replace batteries iaw waterlight casing instructions.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 1 June 2016
Construction/Loadline › Structures › Door
Issued 8 March 2016 Resolved
Renew gasket for the emergency generator room door.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 1 June 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 8 March 2016 Resolved
The shore tie cable has several breaks in the outer insulation and appears decrepit. Require megger testing of cable, cap for cable end and repairs to outer insulation.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 1 June 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.