ARNOLD W. OLIVER

ARNOLD W. OLIVER is a 1996 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1996, most recently in May 2026, along with 48 deficiencies, 2 operational controls and 12 casualty investigations between 2004 and 2023.

Records from 1996 to 2026. Most recent: inspection, 15 May 2026.

Built
1996
Last inspected
15 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW4973
435467
Flag
UNITED STATES
367097570
Maury page id
psix-435467

Inspections, by type

…with no type recorded19
Years with a record 27 calendar years (1996–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)90.7 ft × 44.0 ft × 11.8 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)90.7 ft × 44.0 ft × 11.8 ft
ITC tonnagegross 188 / net 62
BuilderSTEINER SHIPYARD INC · BAYOU LA BATRE, AL, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ARANSAS, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
188 - Convention (Subpart B), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
62 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCW4973MMSI 367097570 · active · compulsorily equipped · granted 14 February 2026, expires 30 April 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WILLIAM G BURNETT Passenger (Inspected) · MISLE 505635 · 6 February 2001 · activity 88751

Inspection history · 78

15 May 2026 Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8344400
8 January 2025 Drydock Exam · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8059040
2 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7888791
10 October 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7806219
9 August 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7769495
8 August 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7767968
14 February 2023 Internal Structural Exam · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7637934
14 October 2022 Damage Survey · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7577707
14 October 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7579017
28 January 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7387419
23 March 2021 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7161548
21 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7114715
5 May 2020 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6948862
6 August 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6826794
17 May 2019 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6689981
7 February 2019 Internal Structural Exam · Drydock Exam · Damage Survey · Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6621798
8 May 2018 Administrative Inspection · In-Service Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6404227
27 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6313501
10 October 2017 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6296066
22 February 2017 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6089390
19 February 2016 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5818401
7 December 2015 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5818209
22 September 2015 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5727058
21 December 2011 Drydock Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4212247
23 September 2011 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4157437
25 January 2011 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3946661
23 December 2009 Hull Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3654554
27 July 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3547471
26 July 2009 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3548448
2 July 2009 Damage Survey · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3521072
17 April 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3454403
14 April 2008 Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3185600
7 February 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3143613
20 January 2008 Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3135488
15 January 2008 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3130634
6 December 2007 Hull Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3110522
17 January 2007 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2856606
13 July 2006 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2712732
15 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2658867
23 February 2006 Hull Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2593316
9 January 2006 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2562005
16 September 2005 Examination of Repairs · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2497006
15 September 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2544298
25 January 2005 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2280285
13 January 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2276309
11 August 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2163497
17 March 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2026702
10 March 2004 Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2021188
26 January 2004 Hull Examination · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1991816
17 January 2003 Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1731259
4 September 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1670762
16 March 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1600722
30 November 2001 COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1366678
12 October 2001 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1384895
11 June 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1065165
12 April 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1061940
6 February 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 88751
28 September 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1054024
15 August 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1052827
26 July 2000 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1440366
8 June 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1050477
7 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 128601
12 April 2000 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1455844
24 January 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2215
8 October 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 788185
2 September 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 78455
31 August 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 785212
2 July 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1097637
16 April 1999 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1360816
23 March 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 717739
22 March 1999 Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1111480
18 March 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 73604
21 January 1999 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1410009
17 April 1998 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1375360
22 April 1997 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1407868
5 February 1997 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1390432
1 July 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1242570
19 April 1996 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1080435

Deficiency record · 48

09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 15 May 2026 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Vessel did not have "KEEP CLEAR" marked on emergency exits.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 19 May 2026
Resolution: Vessel stenciled required markings on both emergency hatches on deck.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: Provide services necessary for safety under normal and emergency conditions. Vessel's lighting along an emergency exit out of the engine room was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2026
Resolved 19 May 2026
Resolution: Vessel replaced emergency lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 October 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel loss propulsion due to a faulty injector. Repaired to the satisfaction to the attending marine injector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 October 2023
Resolution: Installed a new fuel injector.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 August 2023 Resolved
A VESSEL MUST BE PROVIDED WITH A MAIN STEERING GEAR THAT IS: CAPABLE OF STEERING THE VESSEL AT ALL TIMES. VESSEL LOST STEERING DUE TO UNKNOWN CAUSE. DETERMINE CAUSE AND REPAIR TO THE SATISFICATION OF THE ATTENDING MARINE INSPECTOR.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2023
Resolution: Vessel replaced electro switch for steering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. Vessel had a reduction in propulsion while transiting. Repair propulsion machinery to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2022
Resolution: Vessel repaired blower on FWD enginge and ran multiple tests with satisfatory results.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 December 2020 Resolved
Extension cord has been spliced into 12V power cable using electrical tape passing from the engine room into the wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2021
Resolved 23 March 2021
Resolution: Spliced extension cord was removed and replaced with 70 ft of approved cable to go from the engine room to the wheelhouse.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2020 Resolved
Junction boxes, connection boxes, and outlet boxes, for use in damp or wet locations shall be of watertight construction. General alarm juction box located in the upper vestibule was missing its cover. Cover was replaced by crew. 46 CFR 183.10-20(k)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 May 2020
Resolved 14 May 2020
Resolution: General alarm juction box located in the upper vestibule was missing its cover. Cover was replaced by crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2020 Resolved
Non-conductive mats or grating shall be provided on deck in front and rear of switchboards. Non-conductive matting was missing from its required location in front of the generator switchboard. Matting was provided by crew. 46 CFR 183.10-15(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 May 2020
Resolved 14 May 2020
Resolution: Non-conductive matting was missing from its required location in front of the generator switchboard. Matting was provided by crew.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 May 2019 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The vessel experienced a loss of steering while pulling into the dock. The master instructed the crew to reset the circuit breakers which did not help regain steering. Vessel is restricted from carrying passengers until a CG Marine Inspector can attend and verify repairs are satisfactory.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
Resolution: Rudder tiller arm replaced with longer threaded bolt.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 27 November 2017 Resolved
Multiple internal mechanical issues identified at this time.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 December 2017
Resolved 1 December 2017
Resolution: Frozen fuel injector was found by Manufacture Technician. Part was replaced. Completed inspection and machinery trials, all SAT.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 19 February 2016 Resolved
Engine is continously dropping load when a full compliment of cars is on ferry. Engine techinician will be addressing issue.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2016
Resolved 7 March 2016
Resolution: Vessel identified a crack in manifold, water in hydraulic system and gummed injectors. Provided technician report to attending MI.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 25 January 2011 Resolved
Replace double nuts on try-dyne actuator with permanent replacement.
Action required: 705 - Other - as specified
Due 23 February 2011
Resolved 14 April 2011
Resolution: Double nuts replaced with aviation grade locking nuts secured with locktite wire.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 27 July 2009 Resolved
Vessel is to remain out of service and prohibited from carrying passengers.
Action required: 705 - Other - as specified
Resolved 29 July 2009
Resolution: Observed proper operation of both generators in all modes.
Electrical › Electric Generation Source (service) › Switch
Issued 17 April 2009 Resolved
Install battery cut off switch on supply side of alarm system battery.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 1 May 2009
Resolution: Cut off switch installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 17 April 2009 Resolved
Replace missing CO2 operating instructions.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 1 May 2009
Resolution: Replaced instructions.
Engineering › Compressed Air System (control) › Piping
Issued 20 January 2008 Resolved
Make proper and permanent repairs to throttle shifter control air system to the satisfaction of the attending Coast Guard marine inspector. The system is to be tested under power and away from pier prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2008
Resolution: Throttle system repair complete.
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2006 Resolved
Vessel suffered a power failure on 7/7/06 while crossing the Port Aransas channel. First attempts at repair suggested a bad main breaker further examination revealed the generator leads were chaffed. Repair is authorized by certified marine electrician.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2006
Resolved 13 July 2006
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 9 January 2006 Resolved
Repair / replace RPM gauge for Harbor Island side engine.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 9 January 2006
Resolution: RPM gauge replaced satisfactorily.
Electrical › Electrical Distribution System (service)
Issued 10 March 2004 Resolved
Remove or re-connect dead end wiring for lighting in Port Aransas and Harbor Island shaft alleys. LEGACY COMPONENT DESC: Wiring
Due 10 April 2004
Resolved 15 March 2004
Engineering
Issued 10 March 2004 Resolved
Seal vent covers in e/r.
Due 10 April 2004
Resolved 15 March 2004
Lifesaving › Lifebuoys
Issued 10 March 2004 Resolved
Replace line for ring buoy and attached light with dark or UV resistant line. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 10 April 2004
Resolved 15 March 2004
Engineering › Steering Gear System
Issued 17 January 2003 Resolved
Harbor Island rudder indicator only allows travel from 23 degrees port to 35 degrees starboard. LEGACY COMPONENT DESC: Rudder Angle Indicator
Due 17 February 2003
Resolved 14 February 2003
Engineering › Steering Gear System
Issued 17 January 2003 Resolved
Make repairs to Port A rudder ram, excessive leaks. LEGACY COMPONENT DESC: Ram Seal
Due 17 February 2003
Resolved 26 January 2004
Documentation › Markings/Placards
Issued 16 January 2003 Resolved
Post Emergency broadcast placard and emeregency check off list at operating station.
Due 17 February 2003
Resolved 14 February 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 November 2001 Resolved
PROVIDE OPERATING INSTRUCTIONS FOR OPERATING CO2 SYSTEM MANUALLY FROM INSIDE CO2 ROOM IN CASE CABLES BREAK. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 18 February 2002
Resolved 17 January 2003
Engineering › Bilge Water Management System
Issued 30 November 2001 Resolved
INSTALL BILGE ALARMS IN STEERING COMPARTMENTS.
Action required: 705 - Other - as specified
Due 18 February 2002
Resolved 23 February 2004
Accommodation/Occupational Safety
Issued 30 November 2001 Resolved
PROVIDE WASTE MANAGEMENT PLAN FOR ALL VESSELS
Action required: 705 - Other - as specified
Due 18 February 2002
Resolved 30 November 2001
Accommodation/Occupational Safety
Issued 12 October 2001 Resolved
Remove permanent tinting from window on wheelhouse door so as not to obscure navigation visibility.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Documentation
Issued 12 October 2001 Resolved
Renew Safety Radiotelephone Certificate.
Condition: Unknown
Due 12 November 2001
Resolved 12 October 2001
Construction/Loadline
Issued 12 October 2001 Resolved
Install bilge alarms in steering compartments.
Condition: Unknown
Due 12 November 2001
Resolved 12 December 2001
Fire Fighting
Issued 12 October 2001 Resolved
Replace or repair fire nozzle spud chains.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Fire Fighting
Issued 12 October 2001 Resolved
Replace malfunctioning pressure gauge on firemain standpipe.
Condition: Unknown
Due 15 October 2001
Resolved 15 October 2001
Electrical
Issued 12 October 2001 Resolved
Immobilize/secure engineroom battery box to deck.
Condition: Unknown
Due 12 November 2001
Resolved 12 December 2001
Documentation
Issued 12 October 2001 Resolved
Provide waste management plan.
Condition: Unknown
Due 12 November 2001
Resolved 12 December 2001
Accommodation/Occupational Safety
Issued 12 October 2001 Resolved
Provide garbage bag arrangement in wheelhouse, vice hanging garbage bag on electrical panel.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Accommodation/Occupational Safety
Issued 12 October 2001 Resolved
Clear or stow rags, garbage, & loose gear from under wheelhouse consoles.
Condition: Unknown
Due 12 November 2001
Resolved 12 December 2001
Fire Fighting
Issued 12 October 2001 Resolved
Provide instructions for operating fixed firefighting system at operating station inside CO2 locker.
Condition: Unknown
Due 12 November 2001
Resolved 12 December 2001
Navigation
Issued 12 October 2001 Resolved
Repair cracked repeater linkage mounts (both ends/angle iron to rudder stock) and replace linkage on Harbor Island side and bolts to repeater. Port A side angle iron/lindage rubbing on rudder stop (grind where hitting).
Condition: Unknown
Due 12 October 2001
Resolved 15 October 2001
Fire Fighting
Issued 12 April 2001 Resolved
Install automatic shut-down of ships Service Generators and Engineroom Ventilation upon discharge of CO2 system.
Condition: Unknown
Due 15 November 2001
Resolved 12 April 2001
Fire Fighting
Issued 12 April 2001 Resolved
Install fire detection system in engineroom above each generator and main engine with system to alarm in wheelhouse.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Fire Fighting
Issued 8 June 2000 Resolved
LABEL DOG HOUSE DOOR (IN 3 INCH RED LETTERS) EMERGENCY SHUT-DOWN OF ENGINEROOM VENTILATION AND LABEL BREAKER ON INSIDE PANEL.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Fire Fighting
Issued 8 June 2000 Resolved
ENSURE PROPER OPERATION OF AUTOMATIC VENTILATION SHUT-DOWN UPON ACTUATION OF CO2 SYSTEM.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Fire Fighting
Issued 12 April 2000 Resolved
EVALUATE THE SHUT-DOWN BOXES FOR CO2 SYSTEM.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Lifesaving
Issued 2 July 1999 Resolved
RELOCATE/SEPARATE CHILDREN LIFEJACKETS FROM ADULTS AND LABEL STOWAGE ACCORDINGLY.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Lifesaving
Issued 16 April 1999 Resolved
PROVE THAT VESSEL IS ARRANGED, EQUIPPED AND MANUEVERABLE TO RESCUE A HELPLESS PERSON FROM THE WATER IAW 46 CFR 180.210.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Fire Fighting
Issued 16 April 1999 Resolved
RELOCATE PULL STATIONS FOR FIXED ENGINEROOM CO2 SYSTEM AWAY FROM PASSENGER AREA.
Condition: Unknown
Due 16 April 1999
Resolved 16 April 1999
Engineering
Issued 22 March 1999 Resolved
Replace stern propellor.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Lifesaving
Issued 19 April 1996 Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996

Casualty record · 12

17 March 2004Routine · role: Involved in a Marine Casualty · activity 2026702
13 January 2005Routine · role: Involved in a Marine Casualty · activity 2276309
15 September 2005Routine · role: Involved in a Marine Casualty · activity 2544298
15 May 2006Routine · role: Involved in a Marine Casualty · activity 2658867
30 June 2009Routine · role: Involved in a Marine Casualty · activity 3530150
27 July 2009Routine · role: Involved in a Marine Casualty · activity 3547471
23 September 2011Routine · role: Involved in a Marine Casualty · activity 4157437
9 November 2011Routine · role: Involved in a Marine Casualty · activity 4186641
8 August 2012Routine · role: Involved in a Marine Casualty · activity 4405669
5 December 2013Routine · role: Involved in a Marine Casualty · activity 4766308
14 October 2022Routine · role: Involved in a Marine Casualty · activity 7579017
9 August 2023Routine · role: Involved in a Marine Casualty · activity 7769495
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.