HARBOR KING is a 1958 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in December 2025, along with 32 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 4 December 2025.

Built
1958
Last inspected
4 December 2025
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ6570
Flag
UNITED STATES
Maury page id
psix-43558

Documentation record

Registered dimensions (L × B × D)62.1 ft × 24.7 ft × 8.0 ft
Registered tonnagegross 77 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOLBERG BOAT WORKS · STOCKTON, CA, UNITED STATES · built 1958
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

4 December 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8256607
16 September 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8225196
17 June 2025 Internal Structural Exam · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8095336
4 September 2024 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7932723
9 June 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7923374
7 December 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7816749
8 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675402
11 April 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7647947
5 December 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7590949
7 November 2022 Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7590784
6 November 2022 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7590259
9 December 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7348431
21 September 2021 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7317068
26 April 2021 Drydock Extension · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7183049
2 December 2020 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7104901
9 September 2019 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6766456
1 May 2019 Administrative Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6674376
11 December 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6591872
10 September 2018 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6553575
12 December 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6333444
28 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6314183
20 April 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6110282
7 December 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6045394

Deficiency record · 32

02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 16 September 2025 Resolved
Port side longitudinal in the forward tank space is cracked. Repair cracked weld prior to drydock credit.
Action required: 705 - Other - as specified
Resolved 30 September 2025
Resolution: MI attended vessel and witnessed repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2025 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. MI identified several stanchions with broken welds and/or wasted stanchions.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2025
Resolution: Received photos of properly repaird stanchions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2025 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Bilge piping serving the Lazarette Compartment was found to be severely corroded and had a section where the piping was completely wasted away creating a 4 inch hole on the bottom of the pipe. 46 CFR 182.25-5(a)(Old T)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 June 2025
Resolution: Wasted piping was replaced and operational test was conducted to the satisfaction of the attending MI.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 4 September 2024 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel does not have Hailing Port marked on the stern. 46 CFR 185.602(a) 46 CFR 67.123
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 27 September 2024
Resolution: Hailing port marked.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 September 2024 Resolved
Each survival craft required on a vessel must meet one of the following. For a lifefloat - approved under approval series 160.027. The color of the buoyant apparatus must be primarily vivid reddish orange as defined by sections 13 and 14 of FED-STD-595C. All lifefloats onboard faded and in need of repainting. 46 CFR 180.200(a)(2) 46 CFR 160.010-4(n)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 27 September 2024
Resolution: Lifefoats re-painted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 September 2024 Resolved
The equipment required for lifefloats must meet the following specifications. The light must be a floating waterlight approved under approval series 161.010. Batteries in lifefloat waterlights were expired in 2019. 46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 3 October 2024
Resolution: New batteries installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 September 2024 Resolved
Unless other means are provided to ensure that a fire would be limited to the receptacle, waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. Waste receptacles found throughout vessel constructed of combustible material. 46 CFR 177.405 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 27 September 2024
Resolution: Combustible receptacles removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew and other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electric shock. Power outlet above sink in galley found to be inoperable with live wires to outlet. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 3 October 2024
Resolution: New GFCI outlet installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: provide services necessary for safety under normal and emergency conditions. Permanent extension cord installed for microwave in galley. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 27 September 2024
Resolution: Microwave relocated, extension cord removed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 September 2024 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. No operating instructions found near storage space for CO2 cylinders. 46 CFR 185.612 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 3 October 2024
Resolution: Proper placard posted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 September 2024 Resolved
Each entrance to a space storing carbon dioxide cylinders must be conspicuously marked as follows: “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.” No warning sign found at entrance to CO2 storage space. 46 CFR 185.612(g)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 3 October 2024
Resolution: Proper placard posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 September 2024 Resolved
The portable hand bilge pump shall be provided with suitable hoses for pumping bilges on the suction and discharge ends. Hand bilge pump does not have suitable hoses for suction and discharge overboard. 46 CFR 182.25-1(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 9 October 2024
Resolution: Witnessed satisfactory test of newly installed bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 September 2024 Resolved
The bilge suction shall be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Bilge suction pipe in lazarette was found to be missing a strainer. 46 CFR 182.25-5(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 27 September 2024
Resolution: New strainers installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 September 2024 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. 1.5" opening found on door between accommodation space and Engine Room. 46 CFR 181.20-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 27 September 2024
Resolution: Hole plugged.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew and other persons, and the vessel from electrical hazards. Dead-end wire found in Engine Room. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 27 September 2024
Resolution: Dead end wires removed or corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 December 2023 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A shaft alley bilge. Shaft space bilge alarm did not alarm visually or audibly at operating station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 December 2023
Resolved 31 December 2023
Resolution: Deficiency corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2023 Resolved
Provide bearing reading for port and stbd shaft. Will determine replacement based on readings.
Action required: 705 - Other - as specified
Resolved 1 May 2023
Resolution: Bearing readings provided. Shaft bearing repalced; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 April 2023 Resolved
Identified 03 holes in port and stbd stern tube. Repair to original condition.
Action required: 705 - Other - as specified
Resolved 31 May 2023
Resolution: Area cropped and renewed; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 November 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel has damaged areas (13' from bow port side, 3' 7" above the waterline, 42" damaged steel hull-cut open) due to an allision with a cleat at the long dock. Vessel must conduct repairs to the satisfaction of a Marine Inspector before carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2022
Resolved 23 November 2022
Resolution: Vessel satisfactorily repaired the hull with two inserts. All sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 December 2021 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB battery was expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 13 January 2022
Resolution: Operator installed a new EPIRB. Provided updated registration. Batt expires 2031.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 December 2020 Resolved
Provisions shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. There are no current known provisions made for closing the ventilation to the E/R, a CO2 protected space. Provide and prove proper operation of ventilation closures for the Engine Room. Vessel's route is restricted to Lakes, Bays, and Sounds only, until ventilation closures are provided. 46 CFR 181.20-35(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 16 December 2020
Resolution: Ship's crew installed hinged ventilation covers over E/R ventilation openings.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 September 2019 Resolved
A vessel must comply w/the applicable requirements for any radio installations including the requirements for a station loc & install certs. Current DSC on VHF radio is inop & vessel FCC certs are expired. Vessel to provide valid FCC certs & operable VHF-DSC radio installation. Vessel limited to 1,000 feet from shore.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 27 September 2019
Resolution: Vessel corrected and provided FCC certificates.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 September 2019 Resolved
The lifeline shall be properly secured around the sides & ends of the life float or BA, festooned in bights not longer than 3 feet. Vessel to renew lifeline on all sides of each BA as indicated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 27 September 2019
Resolution: Vessel renewed all lifeline on all BA's.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 September 2019 Resolved
Provide a FCC type accepted CAT 1 406MHz EPIRB, installed to auto float free & activate & not be required to carry survival craft. Current EPIRB registration expires in 17 days. Vessel to provide renewal registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 27 September 2019
Resolution: Vessel provided proper EPIRB registration.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 September 2019 Resolved
A hatch exposed to the weather must be watertight. Hatches for the following spaces are missing gaskets & are not watertight. Lazerrette, Shaft space, & sewage space. Vessel to install proper gaskets and make hatches weather tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 27 September 2019
Resolution: Vessel properly installed all gaskets and made hatches weather tight.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 9 September 2019 Resolved
Provide proper identification/labeling of bilge valves.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2019
Resolved 9 September 2019
Resolution: Vessel labeled bilge valves prior to MI departing.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 September 2019 Resolved
Reduce amount of flammable and combustible liguid in the engine room. Vessel is permitted a max of 5 gallons stored in no more than 1 gallon containers. Vessel had aprox 10 new 5 gal pails of oil stored in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2019
Resolved 9 September 2019
Resolution: Vessel removed all 5 gal pails of oil and properly stored them ashore.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 May 2019 Resolved
Vessel is currently overdue for require dry dock examination and must complete a satisfactory dry dock examination prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2019
Resolution: Vessel completed hull exam to the satisfactory of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 December 2018 Resolved
Provide required retroreflective tape on all lifejackets.
Action required: 10 - Deficiency Rectified
Due 11 December 2018
Resolved 11 December 2018
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 December 2018 Resolved
Provide log of monthly EPIRB testing.
Action required: 10 - Deficiency Rectified
Due 11 December 2018
Resolved 11 December 2018
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 December 2017 Resolved
Replace grabline on the STBD side ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 10 January 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 12 December 2017 Resolved
Replace fire pull station placard on topside deck.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 10 January 2018