13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel Master informed that vessel engine would not start in July and was inoperable for approximately 30 days. Owner/operator/master failed to notify the OCMI of condition and repair proposal.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 August 2025
Resolved 15 August 2025
Resolution: Informed master of requirement to report necessary repairs.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 August 2025
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Each fire drill must include:(1) Summoning passengers on a vessel on an overnight voyage to muster or embarkation stations;(2) Summoning the crew to report to assigned stations and to prepare
for and demonstrate assigned duties; and (3) Instruction in the use and location of fire alarms, extinguishers,
and any other fire fighting equipment on board. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. New hire deckhand, serving onboard since June 2025, was unfamiliar with emergency duties in event of fire and was unable to describe responsibilities. Demonstrate competence in presence of marine inspector.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 August 2025
Resolved 15 August 2025
Resolution: Ensured necesarry training and drill was conducted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2025
Resolved
Each Employee assistance program must include education and training on drug & alcohol policy.
Provide a list/log of training, including who attended.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 4 June 2025
Resolution: Received drug and alcohol policy training records.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2025
Resolved
Each owner must ensure that a copy of the approved Vessel Security Plan (VSP) are kept on board. Provide the Coast Guard a copy of the VSP approval letter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 3 June 2025
Resolution: Received ASP approval letter.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 August 2024
Resolved
(a) The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
(b) Each abandon ship drill must include:(1) Summoning the crew to report to assigned stations and prepare for assigned duties;(2) Summoning passengers on a vessel on an overnight voyage to muster stations or embarkation stations and ensuring that they are made aware of how the order to abandon ship will be given;(3) Checking that life jackets are correctly donned;(4) Operation of any davits used for launching liferafts; and(5) Instruction on the automatic and manual deployment of survival craft.
(c) Each abandon ship drill must, as far as practicable, be conducted as if there were an actual emergency.
(f) Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill
scenario and training topics.
a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire.
(b) Each fire drill must include:(1) Summoning passengers on a vessel on an overnight voyage to muster or embarkation stations;(2) Summoning the crew to report to assigned stations and to prepare for and demonstrate assigned duties; and(3) Instruction in the use and location of fire alarms, extinguishers, and any other fire fighting equipment on board.
(c) Each fire drill must, as far as practicable, be conducted as if there were an actual emergency.
(d) Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics.
Vessel Master unable to produce record of drills conducted through 2024 operating season. Perform drills at prescribed intervals determined by owner/operator and submit each drill record to USCG Sector Detroit for review.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2024
Resolved 7 October 2024
Resolution: Confirmed with owner crew to be retrained on requirments of performing and logging drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
All (ventilation) ducts shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. Exhaust piping leaking gas from within segment inside sewage compartment. Repair leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 2 June 2025
Resolution: Exhaust piping replaced.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 May 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port and starboard generator windings found excessively oil soaked. Clean windings and verify soundness of insulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 May 2024
Resolution: oil cleaned from bilge. Windings cleaned and generator technician report (all sat) provided 10JUN24.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and
electric shock. Junction box directly above main engine
missing cover. Replace cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 10 June 2024
Resolution: Junction box cover replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2024
Resolved
No marine employer shall engage or employ any person to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. List of P.R.-employment tested crew not available at inspection. Provide list of all crew who were drug tested and enrolled in the company's DAPI program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 15 May 2024
Resolution: DAPI records provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2024
Resolved
Security drill and exercises. Drills shall be preformed every three months. Exercise shall be preformed every 18 months. Drills and exercise has not been preformed. Conduct drill and exercise and provide documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 17 May 2024
Resolution: Drill and exercise conducted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2024
Resolved
Fire Service report not available. Provide proof of record of portable fire extinguishers service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 15 May 2024
Resolution: Verified inspection tags on portable extinguishers. Reiterated expectation that inspection report to provided at next annual inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The vessels first aid kit contained expired items, renew/replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 May 2024
Resolved 15 May 2024
Resolution: First aid kit replaced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 May 2023
Resolved
Spanner wrenches must be provided for each fire hydrant required by this regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: Spanner wrenchs replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2023
Resolved
Bilge suction shall be fitted with suitable strainers having an open area not less than 3x the area of the bilge pipe. Install strainer on bilge suction in sewage room
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: Bilge strainer replaced
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 October 2022
Resolved
A robust worklist has be issued and can be found in documents and the narrative.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2023
Resolved 15 April 2024
Resolution: Repairs complete
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 April 2022
Resolved
Upper deck capacity must be indicated by a durable marking in at least 1" lettering at entrance to that deck. Upper deck capacity incorrect.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 April 2022
Resolved
Magnetic compass is missing deviation card.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2023
Resolution: Observed compass deviation card posted at the operating station
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2022
Resolved
Life ring buoy grab line found to be dry rotted and needs to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2022
Resolved
Abandon ship and man overboard drills and training shall be logged and include date, training and general description of the drill scenario and training topics. Drills do not include description.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 April 2022
Resolved
Person in command must produce the original Certificate of Documentation. Original not on-board.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 28 April 2022
Resolved
Garbage placard to be posted. Old placard found in pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2022
Resolved
All observed unsafe practices, fire hazards and other hazardous situations must be corrected and guards and protective devices must be in satisfactory condition
Deck plating not secured in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2022
Resolved
All observed unsafe practices, fire hazards and other hazardous situations must be corrected and guards and protective devices must be in satisfactory condition. Oil soaked rags found in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 April 2022
Resolved
All observed unsafe practices, fire hazards and other hazardous situations must be corrected and guards and protective devices must be in satisfactory condition. Extension cords being used as permanent means through watertight bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2022
Resolved
All observed unsafe practices, fire hazards and other hazardous situations must be corrected and guards and protective devices must be in satisfactory condition. Flammable items not in flammable locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2022
Resolved
Fire station on 2nd deck found leaking at valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2021
Resolved
Conduct fire and man overboard drill in the presence of marine inspector. Drills not conducted as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2021
Resolved
Decks should be marked with maximum passenger capacity IAW stability letter in 1" numbers at entrance to deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 16 June 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2021
Resolved
Renew first aid kit to meet required items IAW 46 CFR 160.041-4. Contents found expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 12 May 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 April 2021
Resolved
Each vessel must have at least two operable portable battery lights, 1 at the operating station and 1 at the access to the engine room. Provide lights as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 12 May 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 April 2021
Resolved
Mark both sides of emergency escape in at least 2" letters "EMERGENCY EXIT_- KEEP CLEAR". Found not labeled and with obstructions, clear and label.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 16 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2021
Resolved
Clean bilge suction in fuel tank space and operationally test bilge pump from this space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 April 2021
Resolved
Remove dead end wiring from port generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 12 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 April 2021
Resolved
Secure mount for starboard generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 12 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021
Resolved
WHERE FLEXIBLE NONMETALLIC HOSE IS PERMITTED FOR USE IN PIPING SYSTEMS, IT MUST MEET SAE J-1942 COMPLETE WITH FACTORY ASSEMBLED END FITTINGS COMPLYING WITH SAE J-1475. FLEX HOSE FUEL LINES MUST BE RENEWED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 16 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021
Resolved
An adult life jacket must be provided for each person carried on board, in addition, a number of child size lifejackets equal to at least 10% of the number of persons permitted, or such greater number as necessary to provide a life jacket for each person being carried. Several life jackets destroyed and removed from the vessel. Owner advised that 100% of life jackets would be inspected until a full renewal has taken place given the age of the life jackets.
Action required: 10 - Deficiency Rectified
Resolved 6 May 2021
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 April 2021
Resolved
Update VHF radios with DSC capability - see CG-CVC policy letter 15-06(CH2). New radio to be installed with DSC capabilities as soon as possible but not later than the next annual inspection. Please contact Marine Inspector upon installation.
Action required: 705 - Other - as specified
Resolved 28 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 June 2020
Resolved
The bilge suction shall be fitted with suitable strainers having an open area not less than 3x the area of the bilge pipe. Bilge strainer in forepeak was found to be severely corroded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2020
Resolution: Recieved email from fleet engineer stating forepeak suction was replaced with a new bell housing, elbow, and strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 June 2020
Resolved
An adult life jacket must be provided for each person carried on board, in addition, a number of child size lifejackets equal to at least 10% of the number of persons permitted, or such greater number as necessary to provide a life jacket for each person being carried. 15 lifejackets need retroreflective tape. Ensure lifejackets are stowed in accordance with labels
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2020
Resolution: Observed retro tape and proper stowage of lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 June 2020
Resolved
Each ring lifebuoy on a vessel must be approved with subchapter Q of this chapter. Port and Starboard life rings were found to have surface cracking and deteriorated line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 7 August 2020
Resolution: Observed new life rings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2020
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Electric solenoid valves must not be used unless used in addition to the manual valve. Shut off
valve did not operate, potentially due to failure of 9V battery. Replace with manually operated valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 16 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 June 2020
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at each operating station. Bilge alarm for freezer space is not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 7 August 2020
Resolution: Recieved email from fleet engineer stating that the bilge alarm has been repaired.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 29 June 2020
Resolved
Provide new, legible emergency broadcast placard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 16 September 2020
Resolution: Received email photo of new placards
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 June 2020
Resolved
Renew Certificate of Documentation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 7 August 2020
Resolution: COD renewed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 June 2020
Resolved
As appropriate for the voyage, a vessel must carry adequate and up to date charts. Charts and Navigation rules were not up to date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 7 August 2020
Resolution: Recieved email from fleet engineer stating he printed new coast pilot, light list, and nav rules, and charts. Enrolled in Ocean charting services to keep charts updated.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 June 2020
Resolved
Contact Sector Detroit to conduct drills and underway portion of exam to include operational test of bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 7 August 2020
Resolution: Witnessed MOB drill and discussed fire fighting scenarios with crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2019
Resolved
Renew retro-reflective tape on 26 child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 16 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 April 2019
Resolved
Provide new chart, light list, and coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 16 June 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 25 April 2019
Resolved
Vessel is not conducting security drills and not logging security training. Vessel shall conduct quarterly security drills and log. Log all future security training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 16 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 April 2019
Resolved
Placard for max passengers is labled wrong with 70. Change to 60 IAW stability letter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 16 June 2021
Engineering › Compressed Air System (control) › Fitting
Issued 30 April 2018
Resolved
Replace port side pressure relief valve on air flask.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2018
Resolution: Witnessed test of new safety relief valve.
Engineering › Compressed Air System (control) › Fitting
Issued 30 April 2018
Resolved
Replace STBD pressure gauge on air flask.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 13 June 2018
Resolution: Inspected new gauges.
Construction/Loadline › Structures › Manhole
Issued 30 April 2018
Resolved
Install gasket in hatch in fore-peak.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 13 June 2018
Resolution: Inspected new gasket.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 April 2018
Resolved
Install suitable bracket on fire extinguisher in pilot house.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 13 June 2018
Resolution: Inspected new bracket.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 April 2017
Resolved
Stern light was extinguished.
Due 5 May 2017
Resolved 13 June 2018
Resolution: Cleared.
Engineering › Steering Gear System › Linkage
Issued 27 April 2017
Resolved
Port upper steering quadrant bolt too short. Replace with suitable sized bolt.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 13 June 2018
Resolution: Cleared.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 April 2017
Resolved
Reefer flat bilge high water alarm is inoperative. Repair or replace unit.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 13 June 2018
Resolution: cleared.
Lifesaving › Lifebuoys › Serviceable
Issued 26 April 2016
Resolved
Vessels aft stern ring buoy removed from service due to un-serviceable condition. Renew aft ring bouy and affix proper marking and retro-reflective tape. 60 ft of line to be attached to aft ring bouy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 13 May 2016
Resolution: Ring buoy renewed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 April 2016
Resolved
Waterlight is cracked in a number of citical areas. Renew as appropriate. Renew Water light line and ensure corrosion resistant clip is provided.
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 13 May 2016
Resolution: Floating waterlight renewed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 April 2016
Resolved
Fuel shutoff control valve shall be installed and accessible for closure from outside of the space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 13 June 2018
Resolution: Cleared.