MAURY USCG vessel records Sign in
← All vessels

STIKINE SPIRIT

STIKINE SPIRIT is a 1996 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 1996, most recently in April 2026, along with 65 deficiencies.

Records from 1996 to 2026. Most recent: inspection, 21 April 2026.

Built
1996
Last inspected
21 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCW4744
435633
Flag
UNITED STATES
—
Maury page id
psix-435633

Inspections, by type

…with no type recorded2
Years with a record 26 calendar years (1996–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 44

21 April 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8356714
20 April 2026 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8356537
11 July 2025 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8185953
10 July 2025 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8185929
1 May 2024 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7907286
18 April 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7710787
19 April 2022 Administrative Inspection · COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7438525
8 June 2020 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6971370
14 April 2020 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6939131
8 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6681262
17 April 2019 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6665516
4 May 2018 Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6405845
6 April 2017 Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6119043
19 May 2016 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5881384
1 April 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5850303
15 July 2015 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5185304
10 May 2012 COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4334876
8 July 2009 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3528124
22 July 2008 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3276059
7 July 2008 Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3260681
18 July 2007 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2999474
10 July 2007 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2990884
24 June 2007 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2972349
7 June 2007 Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2954746
23 April 2007 Hull Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2914128
24 July 2006 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2731538
25 April 2006 Annual Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2644146
3 October 2005 Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2506822
10 April 2005 Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2337880
3 August 2004 Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2182367
12 April 2003 Hull Examination · Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1764399
1 May 2002 COI Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1624246
11 September 2001 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1458023
14 May 2001 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1370174
8 March 2001 Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1060544
8 March 2001 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1443150
10 May 2000 Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1403149
11 April 1999 Hull Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1365202
30 March 1998 Hull Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1386247
23 August 1997 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 141946
27 June 1997 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1113391
29 April 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1450039
11 April 1996 MARPOL Annex V Examination · Initial Certification · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1357593
7 March 1996 Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1453215

Deficiency record · 65

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2023 Resolved
A flammable vapor detection system must be operational for 30 seconds prior to engine startup and continue sensing the entire time the engine is running. Detector is not currently functioning; Prove proper operation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 May 2022 Resolved
The machinery space fixed fire fighting system as well as the required portable extinguishers are over due for servicing. Addiionally the the shut down over-ride function was not operational. Ensure all fixed and portable extinguishers are serviced and operating properly prior to carrying passengers! 46CFR176.810; 46CFR181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2022 Resolved
Vessel's hand bilge is OOC: Replace with operational hand pump. 46CFR182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 18 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 May 2022 Resolved
Vessel is required to carry three red/night flares as in addition to the three orange/day flares. Procure required flares prior to carrying passengers!
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2022
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 May 2022 Resolved
Vessel is require to have a means for securing ventilation to machinery space. Currently both port and STBD side of vessel(2 each) are missing the covers. Provide required covers prior to carrying passengers!
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 May 2022 Resolved
First aid kit need to have required content per CFR. Currently the kit is missing Wire splint, tourniquet, eye pads and ointment. Complete first aid kits approved under 46CFR160.041 will also suffice!
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 18 May 2022
Communications › Radio Communications › VHF Radiotelephone
Issued 22 July 2008 Resolved
Provided required Safety Radiotelephony Certificate for VHF radio installation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 5 April 2011
Lifesaving › Lifebuoys › Serviceable
Issued 22 July 2008 Resolved
Replace required Ringbuoy, stencil, and outfit with required line and water light.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2009
Resolution: New Lifering.
Communications › Radio Communications › EPIRB
Issued 22 July 2008 Resolved
Replace expired EPIRB battery and renew NOAA Registration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2008
Resolved 5 April 2011
Lifesaving › Inflatable Liferafts › Not on Board
Issued 22 July 2008 Resolved
Install reqruired liferaft on vessel, ensure arranged to be float free.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2009
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 22 July 2008 Resolved
Provide catch pans with approved flame screen under both gasoline engine racor filters in engine compartment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 7 July 2009
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 5 July 2008 Resolved
Vessel Registration not onboard vessel. Owner putting vessel back together after numerous upgrades. All required documentation shall be placed back onboard vessel prior to vessel operations.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 7 July 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 June 2007 Resolved
Installed fireboy system improperly installed, system does not secure gasoline engines or ventilation. Wire system properly and test in accordance with manufacturer requirements.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: System properly installed as per manufacturers design. All systems secure prior to the release of the suppression agent.
Lifesaving › Lifejacket/PFD (General) › Size
Issued 24 June 2007 Resolved
Provided required child size life jackets in accordance with COI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 July 2007
Resolved 18 July 2007
Resolution: Proper type and amount of child size life preservers purchased and placed onboard.
Communications › Radio Communications › EPIRB
Issued 24 June 2007 Resolved
Replace EPIRB hydro release, complete NOAA registration, and replace cracked EPIRB antenna.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2007
Resolved 18 July 2007
Resolution: Epirb registered with NOAA, new parts ordered and installed.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 24 June 2007 Resolved
Replace ventilation ducting with non-combustible material as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Ducting replaced with metal dryer vent.
Lifesaving › Lifebuoys › Serviceable
Issued 24 June 2007 Resolved
Replace damaged ringbuoy and label with new vessel name.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Ringbuoy replaced with approved / new one, properly labeled and outfitted with required line / light.
Lifesaving › Hand Flares › Expired
Issued 24 June 2007 Resolved
Replace all expired flares and provide required stowage container with proper markings at operating station.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2007
Resolved 18 July 2007
Resolution: The proper type and amount of flares purchased and properly stowed on vessel.
Engineering › Fuel Oil Service System › Filter
Issued 24 June 2007 Resolved
Fabricate and install required gasoline filter drip pans w / flame screens in engine compartment as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 18 July 2007
Resolution: Drip pans fabricated and installed on the interior of the engine compartment as required.
Lifesaving › Inflatable Liferafts › Float Free
Issued 25 April 2006 Resolved
Install life raft in float free arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 April 2006 Resolved
Provide portable lights at operating station and engine room.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Fire Fighting › Fire Bucket › Lanyard
Issued 25 April 2006 Resolved
Install lanyard on fire bucket.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Communications › Audible Communications › Horn/Whistle
Issued 25 April 2006 Resolved
Provide suitable sound producing device.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Communications › Radio Communications › EPIRB
Issued 25 April 2006 Resolved
Provide proof of EPIRB registration.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Lifesaving › Hand Flares › Marking
Issued 25 April 2006 Resolved
Label location of distress signals.
Action required: 705 - Other - as specified
Resolved 26 April 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 April 2006 Resolved
Provide proof of drug program enrollment.
Action required: 705 - Other - as specified
Resolved 26 May 2006
Documentation › Logs/Records › Logbook (official)
Issued 10 April 2005 Resolved
Provide suitable logbook for logging training and drills.
Action required: 705 - Other - as specified
Resolved 14 April 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 April 2005 Resolved
Porvide suitable nautical publications for intended voyage IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Resolved 14 April 2005
Fire Fighting › Fire Bucket › Lanyard
Issued 10 April 2005 Resolved
Ensure all fire buckets have a lanyard attached
Action required: 705 - Other - as specified
Resolved 14 April 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 April 2005 Resolved
Replace wing nuts on battery with regular nuts.
Action required: 705 - Other - as specified
Resolved 14 April 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 10 April 2005 Resolved
Install vent hoses on natural vents in engine room ensuring suction from the bilge.
Action required: 705 - Other - as specified
Resolved 14 April 2005
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 10 April 2005 Resolved
Double clamp center exhaust flex hose.
Action required: 705 - Other - as specified
Resolved 14 April 2005
Engineering › Fuel Oil Service System › Valve
Issued 10 April 2005 Resolved
Install fuel shut off valve on starboard engine end of line.
Action required: 705 - Other - as specified
Resolved 14 April 2005
Communications › Radio Communications › EPIRB
Issued 10 April 2005 Resolved
Provide proof of EPIRB registration.
Action required: 705 - Other - as specified
Resolved 10 April 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 April 2005 Resolved
IAW 46 CFR 177.900 raise deck rails to ensure a minimum height of 39.5" and a minimum of 4" between rail courses.
Due 11 May 2005
Resolved 14 April 2005
Communications › Radio Communications › EPIRB
Issued 3 August 2004 Resolved
Provide proof of current EPIRB registration.
Due 15 August 2004
Resolved 3 August 2004
Communications › Radio Communications › EPIRB
Issued 3 August 2004 Resolved
Install valid hydrostatic release for EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 August 2004 Resolved
Label bilge alarm visual indicator.
Due 15 August 2004
Resolved 3 August 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 3 August 2004 Resolved
Provide adequate suitable nautical publications for intended voyage.
Due 15 August 2004
Resolved 3 August 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 August 2004 Resolved
Provide suitable first aid kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2004
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 3 August 2004 Resolved
Post emergency instructions in operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2004
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 3 August 2004 Resolved
Post life jacket donning instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 3 August 2004 Resolved
Provide suitable logbook for recording crew training, drills and monthly EPIRB tests.
Due 15 August 2004
Resolved 3 August 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 August 2004 Resolved
Service engineroom fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 3 August 2004 Resolved
Provide updated radio safety telephony certificate.
Due 1 September 2004
Resolved 3 October 2005
Resolution: cleared today
Operations/Management › Passenger Operations › Safety Orientation
Issued 1 May 2002 Resolved
Total persons allowed are limited to Ten (10) persons while carrying cargo (canoes & kayaks). This requirement shall remain in effect until completion of a simplified stability test.
Due 22 May 2003
Resolved 3 October 2005
Resolution: cleared today.
Construction/Loadline
Issued 11 September 2001 Resolved
Requirement from JUNMS case MI01004627 cleared and reissued under this casefor the installation of UL-Approved or equivalent electric bilge pumps pre 46 CFR 182.520(e)(1). Extended this requirement due date to facilitate additional approval listing of components. Extended requirement to 15DEC0
Condition: Unknown
Due 15 December 2001
Resolved 1 May 2002
Resolution: Rule Industries email dated 28MAY02, attesting installed pump is UL approved.
Construction/Loadline › Penetrations › Bottom Plug
Issued 11 September 2001 Resolved
REQUIREMENT FROM JUNMS CASE MI01004627 CLEARED AND REISSUED UNDER THIS CASEFOR THE INSTALLATION OF SEA VALVES IWO COOLING WATER INTAKE. EXTENDED REQUIREMENT TILL 15DEC01 TO ALLOW TIME TO RESEARCH HISTORY OF ARRANGEMENT.
Condition: Unknown
Due 15 December 2001
Resolved 3 October 2005
Resolution: Cleared today.
Lifesaving
Issued 8 March 2001 Resolved
DEMONSTRATE PROPERLY-OPERATING WATER LIGHT PER 46 CFR 180.70(D).
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 8 March 2001 Resolved
PROVIDE UL-APPROVED, OR EQUIVALENT, ELECTRIC BILGE PUMPS PER 46 CFR 182.520(E)(1).
Condition: Unknown
Due 23 November 2001
Resolved 23 November 2001
Construction/Loadline
Issued 8 March 2001 Resolved
VEE AND REWELD FRACTURE AREAS AT P/S GUNWALES IN WAY OF BUTT-WELD JOINTS, AND AT TERMINUS OF BILGE BUMP STBD OVERBOARD PIPING.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Fire Fighting
Issued 8 March 2001 Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICING OF FIXED FIRE FIGHTING SYSTEM. (CORRECT PRIOR TO CARRYING PASSENGERS)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 8 March 2001 Resolved
PROVIDE METALLIC DRAIN PLUGS OR OTHER ACCEPTABLE MEANS TO SEAL GRAVITY BILGE DRAIN OPENINGS.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Fire Fighting
Issued 8 March 2001 Resolved
PROVIDE 2 ADDITIONAL FIRE BUCKETS WITH LANYARDS PER 46 CFR 181.610. (PROVIDE PRIOR TO CARRYING PASSENGERS)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Fire Fighting
Issued 8 March 2001 Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER AND PROVIDE EVIDENCE OF ANNUAL SERVICINGFOR ALL PORTABLE FIRE EXTINGUISHERS. (CORRECT PRIOR TO CARRYING PASSENGERS)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Construction/Loadline
Issued 8 March 2001 Resolved
PROVIDE SEA VALVES, OR EQUIVALENT, FOR P/S ENGINE COOLING LINES PER 46 CFR 179.350(C)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Navigation
Issued 8 March 2001 Resolved
PROVIDE AN UPDATED COMPASS DEVIATION TABLE.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Engineering
Issued 10 May 2000 Resolved
Adjust port remote fuel shut-off cable to fully close fuel valve. _x001C_ _x001C_ 46 C.F.R. 182.455(b)(4)
Condition: Unknown
Due 12 May 2000
Resolved 7 June 2000
Construction/Loadline
Issued 10 May 2000 Resolved
Replace/repair high water bilge alarm.
Condition: Unknown
Due 12 May 2000
Resolved 7 June 2000
Lifesaving
Issued 10 May 2000 Resolved
Replace expired orange smoke signals.
Condition: Unknown
Due 12 May 2000
Resolved 7 June 2000
Construction/Loadline
Issued 10 May 2000 Resolved
Make repairs to broken weld located on deck support bracket in after fish hold.
Condition: Unknown
Due 24 May 2000
Resolved 7 June 2000
Fire Fighting
Issued 11 April 1999 Resolved
Prove proper operation of engine and blower automatic shutdown upon discharge of fixed fire system in engineroom. _x001C_
Condition: Unknown
Due 11 April 1999
Resolved 11 April 1999
Unknown
Issued 30 March 1998 Resolved
Get latest edition of 46 CFR part 166-199._x001C_
Condition: Unknown
Due 30 April 1998
Resolved 30 April 1998
Fire Fighting
Issued 30 March 1998 Resolved
Replace discharged HALON bottle in E-room prior to carrying passengers.
Condition: Unknown
Due 30 April 1998
Resolved 30 April 1998
Accommodation/Occupational Safety
Issued 30 March 1998 Resolved
Install safety lines on P & S boarding areas.
Condition: Unknown
Due 30 April 1998
Resolved 30 April 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.