MYSTIC LADY II

MYSTIC LADY II is a 1996 passenger vessel (inspected). The Coast Guard has recorded 56 inspections since 1996, most recently in November 2025, along with 67 deficiencies.

Records from 1996 to 2025. Most recent: inspection, 19 November 2025.

Built
1996
Last inspected
19 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG5323
435663
Flag
UNITED STATES
367545480
Maury page id
psix-435663

Inspections, by type

…with no type recorded2
Years with a record 28 calendar years (1996–2025)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 14.0 ft × 6.8 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARKLEYS MARINA INC · BALTIMORE, MD, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portREEDVILLE, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG5323MMSI 367545480 · active · compulsorily equipped · granted 23 August 2022, expires 13 September 2032
WCW2111MMSI 367096190 · expired · compulsorily equipped · granted 1 March 2006, cancelled 30 April 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 56

19 November 2025 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8269942
31 October 2024 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8019098
30 September 2024 Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8011460
19 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7809902
21 October 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7581679
26 September 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7563498
22 September 2022 Hull Examination · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7563440
14 September 2021 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7308074
2 November 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7082161
3 September 2020 Hull Examination · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7047785
24 March 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6929527
30 October 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6849478
15 October 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6807220
29 August 2019 Type not recorded
No type recorded · USCGC RICHARD SNYDER (WPC 1127) · USCG East District (CGD-E) · Activity 6801793
2 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6573061
18 October 2018 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6555477
29 August 2018 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6525707
28 September 2017 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6271187
7 November 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6035341
12 October 2016 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6013090
3 August 2016 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5959767
23 October 2015 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5756146
9 October 2015 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5238661
9 October 2014 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5003018
28 March 2014 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4828385
20 July 2012 Simplified Stability Test
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4384998
5 July 2012 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4368298
26 March 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3702830
26 March 2010 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3706619
16 March 2009 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3438343
6 May 2008 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3200132
22 April 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3188894
27 March 2008 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3172410
23 July 2007 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3004821
26 April 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2920389
29 March 2007 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2890639
5 July 2006 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2716679
28 March 2006 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2607385
28 March 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2612886
13 April 2005 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2332944
28 March 2005 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2321000
4 May 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2057976
7 April 2004 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2038487
2 May 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1785286
16 April 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1774660
19 April 2002 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1608376
8 April 2002 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1600993
18 April 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1435173
24 April 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1049072
4 April 2000 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1461266
21 April 1999 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1415165
16 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1460184
2 June 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1108524
7 May 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1409678
24 June 1996 Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1445074
19 April 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1400336

Deficiency record · 67

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 September 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is beyond two years from last last inspection, vessels COI is suspended for non compliance with the requirements of subchpater T until credit drydock is given. //46 CFR 176.600(c)(1)// //46 CFR 176.107(c)// //705c//
Action required: 705 - Other - as specified
Resolved 9 October 2024
Resolution: Conducted DDX / ISE, vessel was given credit dry dock on 09OCT24
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Vessels child life jackets were not separated from adult life jackets. 46 CFR 180.78 (a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 8 November 2023
Resolution: Corrected via photographic proof. Image uploaded into documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed out of service hydraulic power take off for anchor windlass mounted in unsafe condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 8 November 2023
Resolution: Corrected via photographic proof. Image uploaded into documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed cooling water intake through hull for out of service generator, operator cut pipe leaving pipe end open causing potential for flooding if valve failed or accidentally opened.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 29 November 2023
Resolution: Corrected via photographic proof. Image uploaded into documents.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 October 2022 Resolved
Each vessel that operates beyond three miles from the Coastline must have on board a 406 MHz EPIRB installed to automatically float free and activate. Vessel's EPIRB hydrostatic release is expired. The vessel is limited to Lakes, Bays, and Sounds. 46CFR180.64 705, 50 c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: O/O purchased and installed new EPIRB hydrostatic release. Attending marine inspector verified proper installation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 October 2022 Resolved
A vessel must carry either a first aid kit approved under 160.041 or equivalent. The first aid kit was missing iodine and ammonia inhalents. 46CFR184.710 16 c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2022
Resolution: O/O purchased iodine and ammonia inhalents for the vessel's first aid kit.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 October 2022 Resolved
The master of the vessel shall ensure that the EPIRB is tested monthly and logged. Monthly EPIRB tests have not been conducted and logged. 46CFR185.728(a&c) 10 c
Action required: 10 - Deficiency Rectified
Resolved 6 October 2022
Resolution: O/O tested EPIRB and logged accordingly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 September 2022 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. The Certificate of Inspection expires on 28SEP22. The vessel may not carry passengers after this date until a new Certificate of Inspection is issued. 46 CFR 176.100(a) 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2022
Resolution: Vessel carried out successful inspection, COI issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2022 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the [name withheld] of the two required 40-BC fire extinguishers listed on the Certificate of Inspection was empty. 46CFR181.500(a) 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2022
Resolution: O/O replaced empty extinguisher.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 November 2020 Resolved
Vessel's FCC Radio Safety Certificate is expired. Vessel is limited to no more than 1,000 FT from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 5 November 2020
Resolution: Vessel provided FCC Radio Safety Cert valid until 03 Nov 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 October 2019 Resolved
Vessel is missing donning placard for Type I lifejackets onboard. Vessel is required to post donning placards visible to crew and passengers. Post placard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 23 October 2019
Resolution: Owner posted lifejacket donning placard.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 15 October 2019 Resolved
Vessel's turbocharger had one exposed section. Piping conveying vapor, gas, or liquid exceeding 150 degrees F must be suitably insulated to prevent injuries. Install lagging on turbocharger.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 30 October 2019
Resolution: Owner lagged turbocharger.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018 Resolved
The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Relabel the number of adult life jackets to reflect the accurate number stated on COI. (46 CFR 185.604(f)).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2018
Resolved 1 November 2018
Resolution: Emailed photo of relabeled accurate number of adult life jackets reflecting the total number on COI.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 18 October 2018 Resolved
Operating as a single operator on a vessel, master is required to have updated first aid and CPR card on board. Provide validated first aid and CPR card. (46 CFR 11.201(i)(2) and Local Policy)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2018
Resolved 25 October 2018
Resolution: Emailed photo of updated first aid/CPR card.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 12 October 2016 Resolved
Fixed fire fighting system in generator compartment forward of machinery space is not labeled with a 12-year hydro stamp. System is not required or listed on COI. Required owner to hydrostatically test or request to remove the system.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 7 November 2016
Resolution: Fixed fire fighting system in generator compartment was serviced to the satisfaction of the attending marine inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 12 October 2016 Resolved
Generator in compartment forward of machinery space is inoperable. All required equipment is operable from the batteries and main propulsion engine's altenator. Required owner to repair generator to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 7 November 2016
Resolution: Generator was activated and functioned properly. Cleared deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 October 2016 Resolved
First aid kit has missing and expired items. Required owner to restock first aid kit to satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 7 November 2016
Resolution: Owner provided CG approved first aid kit. Cleared deficiency.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 October 2015 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in the generator compartment. Visual alarm onboard is inoperable, provide visual alarm.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 October 2015
Resolved 23 October 2015
Resolution: Installed new visual alarm for the generator space's high water alarm.
Construction/Loadline › Penetrations › Valve Flange
Issued 5 July 2012 Resolved
Vessel cannot prove proper operation of inboard sewage discharge valve and generator raw water intake valve. Prove proper operation of both valves while vessel is out of the water in the presence of marine inspector.
Due 18 August 2012
Resolved 19 July 2012
Lifesaving › Hand Flares › Expired
Issued 26 March 2010 Resolved
Vessel required 2 flares in addition to those already onboard IAW 46 CFR 180.68
Due 26 April 2010
Resolved 9 April 2010
Resolution: The vessel provided the 2 flares IAW 46 CFR 180.68
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 March 2010 Resolved
Missing retro-reflective tape on 2 life ring buoys. Replace on all 4 quadrants, both sides IAW 46 CFR 180.70 and 185.604(i)
Due 26 April 2010
Resolved 9 April 2010
Resolution: Replaced retro-reflective tape on 2 ring life buoys IAW 46 CFR 180.70 and 185.604(i)
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 26 March 2010 Resolved
Post emergency instructions at Operating Station IAW 46 CFR 185.510
Due 26 April 2010
Resolved 9 April 2010
Resolution: Posted emergency instructions at Operating Station IAW 46 CFR 185.510
Lifesaving › Lifebuoys › Serviceable
Issued 22 April 2008 Resolved
Replace two ring buoy’s on vessel due to excessive wear. Three buoy’s are required on vessel due to single operator endorsement and as required by vessels current COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2008
Resolved 29 April 2008
Resolution: Owner replaced and showed proof of two new approved lifebuoys.
Engineering › Fuel Oil Service System › Hose
Issued 29 March 2007 Resolved
Connect grounding wire between fuel tank and fill pipe. 46 CFR 182-20-30 (Old T)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 26 April 2007
Stability › Watertight Integrity › General
Issued 29 March 2007 Resolved
Repair Bomar deck plate cover aft of fuel tank to close properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 26 April 2007
Communications › Alarms/Indicators › High Water Alarm
Issued 29 March 2007 Resolved
Repair visual alarm for lazarette high water alarm.
Condition: Unknown
Due 30 April 2007
Resolved 26 April 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 29 March 2007 Resolved
Replace B-II fire extinguisher.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 26 April 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2007 Resolved
Repair anchor light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 26 April 2007
Lifesaving › Lifefloat › Painter
Issued 29 March 2007 Resolved
Correct the lead of the sea painter near the weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 26 April 2007
Communications › Audible Communications › Bell
Issued 29 March 2007 Resolved
Provide a bell of at least 200 mm diameter.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 26 April 2007
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 29 March 2007 Resolved
Provide updated copy of the Inland Navigation Rules.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 26 April 2007
Stability › Freeing Ports › General
Issued 5 July 2006 Resolved
Verify 10" freeboard on vessel loaded with weight to equal number of total persons as required by Stability Letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2006
Resolution: Completed Weight verification test of vessel fully loaded (185 pounds each person) as required. Test completed satisfactory.
Lifesaving › Lifebuoys › Serviceable
Issued 28 March 2006 Resolved
Replace ring buoy within 30 days.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 12 April 2006
Resolution: Replaced ring buoy.
Lifesaving › Hand Flares › Expired
Issued 28 March 2006 Resolved
Replace 3 red and 3 orange flares prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2006
Resolution: Replaced both red and orange flares.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 28 March 2006 Resolved
Provide proof of servicing of the fixed and portable fire extinguishers.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 12 April 2006
Resolution: Provided proof of servicing of the fixed and portable fire extinguishers.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 March 2006 Resolved
Repair portside navigation light.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 12 April 2006
Resolution: Repaired portside navigation light.
Engineering › Bilge Water Management System › Not Operational
Issued 28 March 2006 Resolved
Replace high water bilge alarm in the engine compartment.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 12 April 2006
Resolution: Repaired high water bilge alarm in the engine compartment.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 March 2006 Resolved
Renew FCC Operations Permit. Vessel is restricted to a 1000 feet from shore until proof is provided.
Action required: 705 - Other - as specified
Resolved 12 April 2006
Resolution: Showed proof of renew for FCC Marine Radio Operators Permit.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 April 2005 Resolved
Provide proof of updated COD
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 13 April 2005
Resolution: Faxed copy of new COD.
Personnel › Training › First Aid/CPR
Issued 1 April 2005 Resolved
Provide proof of CPR & Firstaid training.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 13 April 2005
Resolution: Faxed copy of CPR?first aid training Cert.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 1 April 2005 Resolved
Provide proof of active enrollment in DAPI.
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 13 April 2005
Resolution: Master faxed proof of enrollment in DAPI
Documentation › Logs/Records › Drug Test Records
Issued 1 April 2005 Resolved
Provide proof of enrollment in DAPI for deckhand. Vessel is restricted to carrying not more than 16 passengers during daylight hours IAW COI for operating without deckhand, until DAPI issue is resolved.
Action required: 705 - Other - as specified
Resolved 24 July 2007
Resolution: Satisfied requirement by removing deckhand from COI.
Lifesaving › Lifebuoys › Approval
Issued 1 April 2005 Resolved
Install approved type II retro-reflective tape on ring bouy, IAW 46CFR185.604.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 13 April 2005
Resolution: Master faxed proof of purchase.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 April 2005 Resolved
Replace batteries in lifefloat waterlight, IAW 46CFR604.
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 13 April 2005
Lifesaving › Buoyant Apparatus
Issued 17 April 2003 Resolved
Prove operation of lifefloat waterlight battery. LEGACY COMPONENT DESC: Waterlight
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2003
Resolved 30 April 2003
Resolution: Installed new lifefloat waterlight battery.
Lifesaving › Lifejacket/PFD (General)
Issued 17 April 2003 Resolved
Provide separation between adult and children's lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2003
Resolved 30 April 2003
Resolution: Owner provided separation between adult & children''s lifejackets.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 17 April 2003 Resolved
Provide evidence of servicing of fixed halon systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2003
Resolved 30 April 2003
Resolution: Owner provided evidence of annual service of fixed halon systems.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 19 April 2002 Resolved
Prove inspection of fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Due 24 May 2002
Resolved 24 May 2002
Lifesaving › Buoyant Apparatus
Issued 19 April 2002 Resolved
Stow child size PFD's separetely from adult PFD's. LEGACY COMPONENT DESC: Life Jackets
Condition: Improper Installation
Due 24 May 2002
Resolved 24 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 April 2002 Resolved
Provide asprin. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 24 May 2002
Resolved 24 May 2002
Fire Fighting
Issued 4 April 2000 Resolved
PROVIDE (3) THREE DEDICATED FIRE BUCKETS, STENCILED "FIRE BUCKETS" IN CONTRASTING COLORS. (46CFR181.610)
Condition: Unknown
Due 4 May 2000
Resolved 28 April 2000
Lifesaving
Issued 4 April 2000 Resolved
RENEW WEATHERED RETROREFLECTIVE MATERIAL ON RING LIFE BUOY. (46CFR185.604)
Condition: Unknown
Due 4 May 2000
Resolved 28 April 2000
Lifesaving
Issued 4 April 2000 Resolved
PROVIDE 3-6 FT LANYARD WITH DETACHABLE CLIP, TO FLOATING WATERLIGHT AND RING LIFE BUOY. (46CFR180.70.D.2)
Condition: Unknown
Due 4 May 2000
Resolved 28 April 2000
Lifesaving
Issued 4 April 2000 Resolved
PROVIDE 60 FT LIFELINES TO THE TWO (02) ADDITIONAL RING BUOYS CARRIED IAW YOUR VESSEL "APPROVED" SAFETY ORIENTATION BOOKLET.
Condition: Unknown
Due 4 May 2000
Resolved 28 April 2000
Lifesaving
Issued 4 April 2000 Resolved
PROVE PROPER OPERATION OF AFT STEERING BILGE ALARM. (46CFR182.530)
Condition: Unknown
Due 4 May 2000
Resolved 28 April 2000
Lifesaving
Issued 21 April 1999 Resolved
PROVIDE AND POST A LIFEJACKET DONNING PLACARD SUITABLE FOR THE TYPE AND MAKE OF THE LIFEJACKETS ON BOARD. (46 CFR 185.516)
Condition: Unknown
Due 21 May 1999
Resolved 4 May 1999
Navigation
Issued 21 April 1999 Resolved
PRIOR TO OPERATING IN OR NEAR AREAS OF RESTRICTED VISIBILITY, REPAIR FORWARD MASTHEAD LIGHT. (COLREGS)_x001C_ _x001C_
Condition: Unknown
Due 21 May 1999
Resolved 4 May 1999
Engineering
Issued 21 April 1999 Resolved
RENEW MARKINGS FOR FUEL OIL REMOTE SHUTOFF. (46 CFR 182.608)
Condition: Unknown
Due 21 May 1999
Resolved 4 May 1999
Navigation
Issued 7 May 1997 Resolved
OBTAIN U.S. COAST PILOT OR TIDES AND CURRENT TABLES, AND COAST GUARD LIGHT LISTS.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Construction/Loadline
Issued 7 May 1997 Resolved
ATTACH AFT HATCH COVER TO HATCH FRAME TO PREVENT LOSS.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Lifesaving
Issued 7 May 1997 Resolved
LABEL NUMBER OF PERSONS CAPACITY ON LIFE FLOAT. RE-STENCIL EMERGENCY FUEL OIL CUT-OFF.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Documentation
Issued 7 May 1997 Resolved
PROCURE AND POST GARBAGE POLLUTION PLACARD.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Accommodation/Occupational Safety
Issued 19 April 1996 Resolved
Properly install deck rails of 36 inches in height I.A.W 46 Code of FederalRegulations Part 177.900.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Construction/Loadline
Issued 19 April 1996 Resolved
Properly install bilge alarm system for lazarette compartment I.A.W 46 Codeof Federal Regulations Part 181.420.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Construction/Loadline
Issued 19 April 1996 Resolved
Properly repair opening in collision bulkhead caused by the installation ofa bow winch in the forepeak compartment. Repairs to be completed I.A.W 46 Code of Federal Regulations Part 179.310.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Fire Fighting
Issued 19 April 1996 Resolved
Properly install manual and automatic means of activating the fixed fire fighting system I.A.W 46 Code of Federal Regulations Part 181.420.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Fire Fighting
Issued 19 April 1996 Resolved
Properly install a means for automatic shutdown of the main diesel engine, auxiliary generator and exhaust ventilation fan upon activation of the fixed fire fighting system I.A.W 46 Code of Federal Regulations.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.