Documentation record
Registered dimensions (L × B × D)46.0 ft × 14.0 ft × 6.8 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARKLEYS MARINA INC · BALTIMORE, MD, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portREEDVILLE, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 22 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 21 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 21
19 November 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8269942
31 October 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8019098
30 September 2024
Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8011460
19 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7809902
21 October 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7581679
26 September 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7563498
22 September 2022
Hull Examination · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7563440
14 September 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7308074
2 November 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7082161
3 September 2020
Hull Examination · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7047785
24 March 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6929527
30 October 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6849478
15 October 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6807220
29 August 2019
Type not recorded
No type recorded · USCGC RICHARD SNYDER (WPC 1127) · USCG East District (CGD-E) · Activity 6801793
2 November 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6573061
18 October 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6555477
29 August 2018
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6525707
28 September 2017
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6271187
7 November 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6035341
12 October 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6013090
3 August 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5959767
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 September 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is beyond two years from last last inspection, vessels COI is suspended for non compliance with the requirements of subchpater T until credit drydock is given.
//46 CFR 176.600(c)(1)//
//46 CFR 176.107(c)//
//705c//
Action required: 705 - Other - as specified
Resolved 9 October 2024
Resolution: Conducted DDX / ISE, vessel was given credit dry dock on 09OCT24
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Vessels child life jackets were not separated from adult life jackets.
46 CFR 180.78 (a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 8 November 2023
Resolution: Corrected via photographic proof. Image uploaded into documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed out of service hydraulic power take off for anchor windlass mounted in unsafe condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 8 November 2023
Resolution: Corrected via photographic proof. Image uploaded into documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed cooling water intake through hull for out of service generator, operator cut pipe leaving pipe end open causing potential for flooding if valve failed or accidentally opened.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 29 November 2023
Resolution: Corrected via photographic proof. Image uploaded into documents.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 October 2022
Resolved
Each vessel that operates beyond three miles from the Coastline must have on board a 406 MHz EPIRB installed to automatically float free and activate. Vessel's EPIRB hydrostatic release is expired. The vessel is limited to Lakes, Bays, and Sounds.
46CFR180.64 705, 50 c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2022
Resolution: O/O purchased and installed new EPIRB hydrostatic release. Attending marine inspector verified proper installation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 October 2022
Resolved
A vessel must carry either a first aid kit approved under 160.041 or equivalent. The first aid kit was missing iodine and ammonia inhalents.
46CFR184.710 16 c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2022
Resolution: O/O purchased iodine and ammonia inhalents for the vessel's first aid kit.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 October 2022
Resolved
The master of the vessel shall ensure that the EPIRB is tested monthly and logged. Monthly EPIRB tests have not been conducted and logged.
46CFR185.728(a&c) 10 c
Action required: 10 - Deficiency Rectified
Resolved 6 October 2022
Resolution: O/O tested EPIRB and logged accordingly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 September 2022
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. The Certificate of Inspection expires on 28SEP22. The vessel may not carry passengers after this date until a new Certificate of Inspection is issued.
46 CFR 176.100(a)
701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2022
Resolution: Vessel carried out successful inspection, COI issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the [name withheld] of the two required 40-BC fire extinguishers listed on the Certificate of Inspection was empty.
46CFR181.500(a) 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2022
Resolution: O/O replaced empty extinguisher.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 November 2020
Resolved
Vessel's FCC Radio Safety Certificate is expired. Vessel is limited to no more than 1,000 FT from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 5 November 2020
Resolution: Vessel provided FCC Radio Safety Cert valid until 03 Nov 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 October 2019
Resolved
Vessel is missing donning placard for Type I lifejackets onboard. Vessel is required to post donning placards visible to crew and passengers. Post placard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 23 October 2019
Resolution: Owner posted lifejacket donning placard.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 15 October 2019
Resolved
Vessel's turbocharger had one exposed section. Piping conveying vapor, gas, or liquid exceeding 150 degrees F must be suitably insulated to prevent injuries. Install lagging on turbocharger.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 30 October 2019
Resolution: Owner lagged turbocharger.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018
Resolved
The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Relabel the number of adult life jackets to reflect the accurate number stated on COI. (46 CFR 185.604(f)).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2018
Resolved 1 November 2018
Resolution: Emailed photo of relabeled accurate number of adult life jackets reflecting the total number on COI.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 18 October 2018
Resolved
Operating as a single operator on a vessel, master is required to have updated first aid and CPR card on board. Provide validated first aid and CPR card. (46 CFR 11.201(i)(2) and Local Policy)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2018
Resolved 25 October 2018
Resolution: Emailed photo of updated first aid/CPR card.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 12 October 2016
Resolved
Fixed fire fighting system in generator compartment forward of machinery space is not labeled with a 12-year hydro stamp. System is not required or listed on COI. Required owner to hydrostatically test or request to remove the system.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 7 November 2016
Resolution: Fixed fire fighting system in generator compartment was serviced to the satisfaction of the attending marine inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 12 October 2016
Resolved
Generator in compartment forward of machinery space is inoperable. All required equipment is operable from the batteries and main propulsion engine's altenator. Required owner to repair generator to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 7 November 2016
Resolution: Generator was activated and functioned properly. Cleared deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 October 2016
Resolved
First aid kit has missing and expired items. Required owner to restock first aid kit to satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 7 November 2016
Resolution: Owner provided CG approved first aid kit. Cleared deficiency.