MAURY USCG vessel records
← All vessels

PAPYRUS

PAPYRUS is a 1996 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in June 2026, along with 41 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 24 June 2026.

Built
1996
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX4526
435675
Flag
UNITED STATES
Maury page id
psix-435675

Documentation record

Registered dimensions (L × B × D)39.7 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS INC · TARPON SPRINGS, FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portLA PARGUERA, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 41 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

24 June 2026 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8460766
16 September 2025 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8200053
17 July 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7961352
12 April 2024 Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7894302
27 April 2023 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7675923
10 April 2023 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7661613
20 January 2023 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7624363
21 June 2022 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7483177
24 May 2022 Drydock Exam · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7458180
28 March 2022 Examination of Repairs
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7424575
23 March 2021 Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7161436
28 May 2020 Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6963027
22 April 2020 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6942239
19 March 2019 Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6645235
17 August 2018 Deficiency Check · In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6517435
2 April 2018 COI Inspection · Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6383482
14 March 2018 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6371603
13 July 2017 Administrative Inspection · In-Service Inspection · Deadweight Survey · Construction Oversight
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6205398
21 April 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6121893
25 April 2016 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5843716
23 February 2016 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5811218

Deficiency record · 41

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's Port navigation light was extinguished, replace to satisfaction of attending MI. - 46 CFR 183.420 - 705 - Prior to Night OPS.
Action required: 705 - Other - as specified
Resolved 24 June 2026
Resolution: Operator submitted picture evidence of working Port Nav light.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 24 June 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Bilge Alarms need to be labeled to locate space where bilge alarm is located, to satisfaction of attending MI. - 46 CFR 182.530 - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2026
Resolution: Vessel provided picture evidence of lables on bridge console.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2026 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Bridge Fire extinguisher was not mounted. Mount to satisfaction of NFPA 10 and Attending MI. - 46 CFR 181.520 - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2026
Resolution: Operator provided picture evidence of new extinguisher mount at helm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. VSL adult passenger capacity reduced to 47. Replace 04 unserviceable type 1 life jackets with CG approved type 1 life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2024
Resolved 17 July 2024
Resolution: Replaced in-kind.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 July 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's 360 degree light is inoperable. Must replace in-kind.
Action required: 705 - Other - as specified
Due 17 August 2024
Resolved 17 July 2024
Resolution: Replaced in-kind.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 April 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. VSL adult passenger capacity reduced to 39. Replace 12 unserviceable type 1 life jackets with CG approved type 1 life jackets. 46CFR180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 April 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Replaced first aid kit expired items. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2023 Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Replace fuel bowls with steel or steel filter. 46CFR182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 April 2023 Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. Attach center bench to the deck. 46CFR177.820 (b).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 April 2023 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Replace deteriorated water light line. 46CFR180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 April 2023 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Re install aft Fire extinguisher so that the extinguisher is able to be properly secured. 46CFR181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 April 2023 Resolved
Vessel’s stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Post stability letter. 46CFR176.306
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 April 2023 Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. 46CFR67.123 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 March 2021 Resolved
EPIRB battery expired August 2020.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 23 March 2021 Resolved
Life jacket clips wasted, name of vessel missing on several, and retro-reflective tape wasted on nearly all.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2021 Resolved
Two of three required fire buckets onboard. Crew attached requird lanyards during inspection as directed by Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 March 2021 Resolved
Port navigation light inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 March 2021 Resolved
First aid kit items expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 March 2021 Resolved
The owner, charter, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting under underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by 185.510 of this part, and when applicable, the duties listed in the station bill by 185.514. Written documentation of crew duties not available to U.S. Coast Guard. 46 CFR 185.420 (a)(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 March 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts (2) U.S. Coast Pilot (3) Coast Guard Light List. Nautical publications were outdated (2019).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 23 March 2021 Resolved
Both licensed Coast Guard Captains for vessel could not provide a FCC Marine Radio Operator Permit as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 18 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 March 2021 Resolved
When, in accordance with 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Stability Letter was not posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 March 2021 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following unmanned spaces:(3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Port high water alarm did not work upon testing by Coast Guard. Crew repaired faulty wiring and alarm tested satisfactory.
Action required: 10 - Deficiency Rectified
Resolved 24 March 2021
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 March 2019 Resolved
High water bilge alarms (visual indicators were inoperative)
Action required: 10 - Deficiency Rectified
Resolved 20 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 March 2019 Resolved
Missing one Type I PFD per COI.
Action required: 10 - Deficiency Rectified
Resolved 2 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 March 2019 Resolved
Type I retro reflective tape on most PFDs wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 2 April 2019
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 March 2019 Resolved
Forward Starboard fire extinguisher bracket wasted and also did not fit extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 2 April 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 March 2019 Resolved
FCC Radio Telephony Certificate had an incorrect Radio Statioin Call Sign (per FCC Station license). Also, no notation for installed EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 March 2019 Resolved
Port side, stern compartment bilge pump was inoperative.
Action required: 10 - Deficiency Rectified
Resolved 2 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019 Resolved
Fuel Shutoff Valves for both fuel tanks did not have securing instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 2 April 2019
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 March 2019 Resolved
Vessel had incorrect Hailing port on stern per current USCG COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 2 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 March 2019 Resolved
Storage cabinet for Type I PFDs on Port Starboard side did not clearly mark location of PFDs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 2 April 2019
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 19 March 2019 Resolved
Monthly tests of installed EPIRB were not consistently conducted during the past year (from date of this Annual inspection).
Action required: 10 - Deficiency Rectified
Resolved 19 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2018 Resolved
Starboard transmission requires replacement due to component failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 April 2017 Resolved
provide proper operation of all port side high water alarm visual indicator. (46CFR182.530(c)
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 May 2017
Resolution: replaced indicator.
Navigation › Piloting/Steering › Marine Charts
Issued 21 April 2017 Resolved
Provide current chart for area transited, coast pilot, and tide tables, on board vessel. (46VFR184.420)
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 May 2017
Resolution: purcahsed new chart, coast pilot, and tide tables.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 April 2017 Resolved
Provide firt aid kit in compliance with 46CFR160.041-4. (46CFR 184.710)
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 May 2017
Resolution: Purchased new approved first aid kit.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 21 April 2017 Resolved
Replace fire extinguisher bracket for BI extinguisher. (46CFR181.520)
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 May 2017
Resolution: New bracket purchased and replaced old one.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 21 April 2017 Resolved
Remove signs covering ventilation supply vents on both sides. (46CFR182.460)
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Signs were moved forward to uncover vents.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 21 April 2017 Resolved
Replace ventilation exhaust hose with hole in starboard fuel space.(46CFR184.420)
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 10 May 2017
Resolution: New hose installed on vessel.
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2016 Resolved
Make permanent repairs back to original all spots identified on the hull from examination, IAW 46 CFR 176.600.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 February 2016
Resolution: All spot repaired to original.

Ownership record