MAURY USCG vessel records
← All vessels

MY JOYCE III

MY JOYCE III is a 1996 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in June 2025, along with 8 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 12 June 2025.

Built
1996
Last inspected
12 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI3254
435738
Flag
UNITED STATES
Maury page id
psix-435738

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)40.7 ft × 13.5 ft × 5.0 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMICHAEL FITZ · NAPLES, FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

12 June 2025 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8157260
4 February 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8072709
16 May 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7914136
5 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7704443
7 February 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7630224
9 June 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7473519
10 December 2021 Type not recorded
No type recorded · USCGC COHO (WPB 87321) · USCG Southeast District (CGD-SE) · Activity 7366629
11 May 2021 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7193678
26 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7199454
28 July 2020 Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7012447
30 May 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6680425
27 February 2019 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6620298
5 June 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6420579
14 June 2017 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6141248
28 September 2016 Internal Structural Exam · Plan Review "T" Boat · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6018137
21 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5923264

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2025 Resolved
Renew life ring.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 23 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 June 2025 Resolved
Prove proper operation of interconnected smoke detection.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2025
Resolved 23 June 2025
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 May 2024 Resolved
The vessel had the MMSI number but not the lat/long as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2024
Resolved 24 June 2024
Resolution: Provided proof lat/long on radio.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 May 2024 Resolved
Vessel is on an oceans route and required interconnected smoke detectors. Although installed, they did not work.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2024
Resolved 24 June 2024
Resolution: New one bought and installed, all working.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 16 May 2024 Resolved
The vessel is on an oceans route and cannot get alcohol tested within two hours, so is required to carry on board alcohol testing strips.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2024
Resolved 24 June 2024
Resolution: Correct ones purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 May 2021 Resolved
Renew life ring
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2021
Resolved 17 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2019 Resolved
Non metallic fuel filter/strainer shall be approved. Fuel Strainer missing flame bowl. 46 CFR 182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 5 June 2019
Resolution: Received photographic evidence of proper fuel strainer set up.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 May 2019 Resolved
Fire Extinguishers must be serviced annually. Aft deck fire extinguisher needs to be serviced. 46 CFR 176.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 5 June 2019
Resolution: Received photographic evidence that the fire extinguisher had been replaced.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.