MAURY USCG vessel records Sign in
← All vessels

STELLA MARIS II

STELLA MARIS II is a 1976 freight ship. The Coast Guard has recorded 28 inspections since 1996, most recently in April 2016, along with 74 deficiencies and 2 operational controls.

Records from 1996 to 2016. Most recent: inspection, 5 April 2016.

Built
1976
Last inspected
5 April 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7413907 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
E5U2232
435773
Flag
COOK ISLANDS
—
Maury page id
psix-435773

Inspections, by type

…with no type recorded16
Years with a record 10 calendar years (1996–2016)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it1939 - Convention (Subpart B), Gross Ton
1087 - Convention (Subpart B), Net Ton
3022 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

5 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5847842
14 March 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5832559
26 February 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5826454
5 January 2016 Deficiency Check · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5790959
3 December 2015 Deficiency Check · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5775038
13 November 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5763223
28 October 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5752401
28 September 2010 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3793910
28 September 2010 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3875306
20 September 2004 PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2199454
8 February 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 286962
6 January 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 285826
4 October 2000 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 822631
9 June 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 279306
15 December 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 435790
7 September 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 432604
6 August 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 778041
21 June 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 429898
23 November 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 422904
30 June 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 417405
1 June 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 422483
15 April 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414886
30 March 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414230
1 July 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 24144
6 June 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 404474
16 May 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 403659
28 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 391652
10 April 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 389840

Deficiency record · 74

Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 5 January 2016 Resolved
The LRIT Conformance Test Report shall be issued by vessel's flag in accordance with MSC1/CIRC. 1307. 74 SOLAS(14 Cons)Ch.V/Reg 19-1
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 January 2016
Resolved 26 February 2016
Resolution: Vessel submitted LRIT Conformance Report issued by Cook Islands.
Construction/Loadline › Structures › Superstructure
Issued 3 December 2015 Resolved
0956 - For all ships the means of embarkation and disembarkation shall be inspected and maintained in suitable condition. The gangway is out of working order due to a crack midway through it. 74SOLAS(14 cons.) Ch.II-1/Reg 3-9.3
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 5 April 2016
Resolution: Port State Control Office Miami received Flag survey report attesting to permanent repairs to the vessel's accomodation ladder.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 October 2015 Resolved
0686-Before the ship leaves port all life saving appliances shall be in working order. The port side, aft lifebuoy, self-igniting light is inoperable. 74 SOLAS(14 Cons)Ch.III/Reg 20.2
Action required: 705 - Other - as specified
Due 28 October 2015
Resolved 28 October 2015
Resolution: The self-igniting light was repaired prior to the PSCO departing the vessel. Deficiency rectified.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 October 2015 Resolved
2035-Fire control plans and booklets shall be kept up to date. The fire control plans still reflect the approval from the previous Administration. 74 SOLAS(14 Cons.)/Ch.II-2/Reg.15.2.4.1
Action required: 15 - Rectify deficiencies by next port
Resolved 13 November 2015
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 28 October 2015 Resolved
0199-Equipment for Long Range Identification and Tracking(LRIT) of ships shall be approved by the Administration. Tanzania has not issued any documentation to the ship attesting to the conformance or LRIT requirments.
Action required: 15 - Rectify deficiencies by next port
Resolved 13 November 2015
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 September 2004 Resolved
Provide US Coast Pilot publication a receipt of purchase to be faxed to the office.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 20 September 2004
Resolved 20 September 2004
Resolution: Master presented receipt.
Navigation › Piloting/Steering › Gyro Compass
Issued 20 September 2004 Resolved
Provide Technical report attesting to the proper operation of gyro compass.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2004
Resolved 22 September 2004
Resolution: Recieved tech report from certified technician to the installation of new gyro compass and proper operation.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 20 September 2004 Resolved
Provide Emergency Escape Breathing Apparatus (SOLAS as ammended II-2/13.3.4). Class to verify location and make necessary annotations to the fire control plan & safety equipment certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 October 2004
Resolved 28 September 2010
Resolution: Discrepancy cleared during recent PSC exam.
Electrical
Issued 6 January 2001 Resolved
INADEQUATE INSTALLATION OF ALL CARGO DECK SPOT LIGHTS ON UPPER BRIDGE. LIGHTS NEED JUNTION BOXES TO MAKE ELECTRICAL CONNECTION OR RUN WIRE TO END ENSIDE THE [name withheld].
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Electrical
Issued 6 January 2001 Resolved
FIRST AND SECOND DECK SHOWER ROOM [name withheld] TO BE REPLACED FOR ONE WATERPROOF. FLUORESCENT [name withheld] TO A HIGH HUMIDITY ENVIROMENT.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Navigation
Issued 6 January 2001 Resolved
[name withheld] NEEDS TO BE REPLACED. LIGHT BLINKS ON AND OFF WHEN SWITCH IS IN ON POSITION.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Electrical
Issued 6 January 2001 Resolved
LIVE WIRES EXPOSED OUT OF A RECEPTICLE AT HOSPITAL ENTRANCE.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Navigation
Issued 6 January 2001 Resolved
RENEW OR UP-DATE THE APPROCHING CHART OF PUERTO RICO NUMBER 25640 AND SAN JUAN HARBOR CHART NUMBER 25670 PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Accommodation/Occupational Safety
Issued 6 January 2001 Resolved
REPAIR/REPLACE LADDER TO ITS ORIGINAL CONDITIONS AT STARBOARD SIDE BOW (TOACCESS FOXHOLE "ANCHOR DECK") TO THE SATISFACTION OF CLASS SOCIETY/ADMINISTRATION.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Electrical
Issued 6 January 2001 Resolved
REPAIR GENERATOR # 4 TO SATISFACTION OF CLASS/ADMINISTRATOR.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Electrical
Issued 6 January 2001 Resolved
REMOVE EXCESS WIRES CONNECTED TO THE EMERGENCIES BATTERIES PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Fire Fighting
Issued 6 January 2001 Resolved
PROVIDE MISSING NOZZLE TO FIRE STATION AT PORT SIDE AFT BOAT DECK PRIOR TO DEPARTURE.
Condition: Unknown
Due 6 January 2001
Resolved 8 January 2001
Electrical
Issued 6 January 2001 Resolved
PORT NAVIGATION LIGHT WIRING HAS EXPOSED SECTION. REPAIR PRIOR TO DEPARTURE.
Condition: Unknown
Due 6 January 2001
Resolved 8 January 2001
Electrical › Lighting (service) › Lighting Fixture
Issued 6 January 2001 Resolved
WALL LIGHT FIXTURE IN CABIN 15 NEEDS TO BE REPLACED OR RE-INSTALL ORIGINAL [name withheld] ALL CREW CABINS FOR SAME REQUIREMENT.
Condition: Unknown
Due 1 March 2001
Resolved 28 September 2010
Resolution: Discrepancy cleared during PSC exam
Electrical
Issued 6 January 2001 Resolved
HOSPITAL BED LIGTH FIXTURE MISSING. LIVE WIRES EXPOSED.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Engineering
Issued 6 January 2001 Resolved
PROVIDE REPORT FROM CLASS SOCIETY ON THE MAIN ENGINE GOVERNOR PROPERLY OPERATION PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Fire Fighting
Issued 6 January 2001 Resolved
SERVICE EMPTY (2) FIRE EXTINGUISHERS (SMALL ONE IN THE BRIDGE AND BIG ONE PASSAGEWAY OUTSITE BRIDGE) PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Navigation
Issued 6 January 2001 Resolved
REPAIR INOPERABLE GMDSS TO SATISFACTION OF CLASS SOCIETY PRIOR TO DEPARTURE. GMDSS IS NOT WORKING SINCE NOV 2000.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Documentation
Issued 6 January 2001 Resolved
HAVE CLASS SOCIETY TO VERIFY VALIDITY OF SAFETY EQUIPMENT CERTIFICATE. SPACES LEFT IN BLANK (#'S OF LIFERAFTS) AND NUMBER OF PERSONS FOR WHICH LIFE-SAVING APPLIANCES ARE PROVIDED VS NUMBER OF PERSONS ON BOARD. HAVE CLASS REPORT FAX TO COAST GUARD PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 January 2001
Resolved 8 February 2001
Engineering
Issued 9 June 2000 Resolved
WIPE DOWN EXCESS OIL IN ENGINE ROOM AND GENERATOR ROOM PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 June 2000
Resolved 26 June 2000
Fire Fighting
Issued 9 June 2000 Resolved
STENCIL FIRE MAIN VALVE TO PAINT LOCKER PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 June 2000
Resolved 26 June 2000
Accommodation/Occupational Safety
Issued 9 June 2000 Resolved
REPAIR HANDRAIL AND LADDER ON STARBOARD BOW TO THE SATISFACTION OF CLASS NOLATER THAN 09 JULY 2000.
Condition: Unknown
Due 9 July 2000
Resolved 26 June 2000
Documentation
Issued 9 June 2000 Resolved
PROVIDE UPDATED SAFE MANNING CERTIFICATE REFLECTING CHANGE IN GROSS TONNAGEFROM 1570 TO 1939 NO LATER THAN 09 JULY 00.
Condition: Unknown
Due 9 July 2000
Resolved 26 June 2000
Documentation
Issued 9 June 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 2000
Resolved 26 June 2000
Accommodation/Occupational Safety
Issued 9 June 2000 Resolved
CLEAN GREASE TRAP IN GALLEY PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 June 2000
Resolved 26 June 2000
Lifesaving
Issued 9 June 2000 Resolved
PROVIDE HYDROSTATIC RELEASE FOR EPIRB PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 June 2000
Resolved 26 June 2000
Fire Fighting
Issued 9 June 2000 Resolved
PROVIDE MISSING FIRE HELMET FOR SECOND FIRE SUIT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Navigation
Issued 9 June 2000 Resolved
REPAIR LEAK ON OIL LINE TO STEERING PUMP PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 June 2000
Resolved 26 June 2000
Construction/Loadline
Issued 21 June 1999 Resolved
CROP AND RENEW WASTED CEILING LOCATED IN A/C ROOM, IMMEDIATELY AT ENTRANCE AND NEXT TO LONGITUDINAL FRAME.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 21 June 1999 Resolved
PROVIDE AND OR REPLACE GASKETS FOR HATCHES #4, #5, #6, #11, #12, #13, #14, PORT AND STARBOARD WHERE MISSING. EXAMINE ALL OTHER CARGO HATCHES AND REPLACE/PROVIDE GASKETS AS NEEDED.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Fire Fighting
Issued 21 June 1999 Resolved
REPLACE SHOULDER STRAP FOR SCBA. (PARTED DURING FIRE DRILL)
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Fire Fighting
Issued 21 June 1999 Resolved
REPAIR MINOR AIR LEAK NOTED AT SCBA AND MASK HOSE CONNECTION.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 21 June 1999 Resolved
PROVIDE SAFETY GUARD FOR ROTARY EQUIPMENT FOR EMERGENCY FIRE PUMP.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 21 June 1999 Resolved
PROPERLY REPLACE PORT SIDE HYDROSTATIC RELEASE. (IT WAS PAINTED OVER)
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 21 June 1999 Resolved
RENEW RESCUE BOAT RETROREFLECTIVE TAPE.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Documentation
Issued 21 June 1999 Resolved
PROVIDE ALL VESSEL RELATED CERTIFICATES AND DOCUMENTS TO INCLUDE: LOADLINE CERTIFICATE, REGISTRY, SAFETY RADIO, IOPP, SAFETY CONSTRUCTION, SAFETY EQUIPMENT, ITC, SAFETY MANNING.
Condition: Unknown
Due 5 July 1999
Resolved 23 June 1999
Documentation
Issued 21 June 1999 Resolved
PROPERLY AMEND SOLAS TRAINING MANUAL AS TO REFLECT THE USE OF THE RESCUE BOAT AND SHIPBOARD FIREFIGHTING EQUIPMENT .
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Documentation
Issued 21 June 1999 Resolved
PROVIDE TANKS AND LINE PIPING DIAGRAM FOR OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Navigation
Issued 21 June 1999 Resolved
PROVIDE INMARSAT SCREEN FOR GMDSS. (UNIT ASHORE FOR REPAIRS)
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 21 June 1999 Resolved
PROVIDE SUITABLE RUBBER MAT FOR GENERATOR SWITCHBOARD.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Fire Fighting
Issued 21 June 1999 Resolved
REPLACE DAMAGED SMOKE DETECTOR ABOVE STBD GENERATOR AND STBD SIDE FORWARD OF MAIN DIESEL ENGINE.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Navigation
Issued 21 June 1999 Resolved
MAKE PROPER CORRECTION TO RUDDER ANGLE INDICATOR'S DEGREE DIFFERENCES. (5 DEGREES TO PORT AND 2 DEGREES TO STBD)
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Construction/Loadline
Issued 30 June 1998 Resolved
PROPERLY REPAIR CARGO BILGE DISCHARGE. CORRECT PRIOR TO NEXT U.S. PORT TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Lifesaving
Issued 1 June 1998 Resolved
MAKE RESCUE BOAT READILY AVAILABLE WITH EQUIPMENT AND MOTOR. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Documentation
Issued 1 June 1998 Resolved
PROVIDE CERTIFICATES OF COMPETENCY FOR 1ST ENGINEER AND ABLE BODIED SEAMAN TO SATISFACTION OF CLASS. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Fire Fighting
Issued 1 June 1998 Resolved
RENEW GAUGE FOR EMERGENCY FIRE PUMP. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Fire Fighting
Issued 1 June 1998 Resolved
RENEW FIRE DAMPERS/VENT CLOSURES ON HOUSE EXTERIOR TO SATISFACTION OF CLASSSOCIETY. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 1 June 1998 Resolved
HAVE PORT SIDE STERN CORNER BULWARKS DAMAGE SURVEYED BY CLASS SOCIETY. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 1 June 1998 Resolved
HAVE CLASS SURVEY HULL DAMAGE IN GENERATOR COMPARTMENT BETWEEN FRAMES 7 AND9. CLASS SURVEY DONE.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 1 June 1998 Resolved
PROVIDE CLOSURE DEVICES TO PREVENT DOWN FLOODING FOR ENGINEROOM GOOSE NECK VENT IN WAY OF PORT AND STARBOARD SIDE OF HOUSE ON 01 DECK. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Lifesaving
Issued 1 June 1998 Resolved
PROVIDE LIFEBOAT OR SAFETY EXEMPTION CERTIFICATE FOR SAME AS PER SOLAS. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Navigation
Issued 1 June 1998 Resolved
REPAIR RADAR SO IT CAN READ ABOVE 10 MILE RANGE. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Fire Fighting
Issued 1 June 1998 Resolved
FREE UP AND DEMONSTRATE PROPER OPERATION OF FIRE DAMPER ON FORCED AIR VENTILATION BLOWER FOR ENGINE ROOM. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Fire Fighting
Issued 1 June 1998 Resolved
FREE UP ENGINEROOM VENTILATOR CLOSURES ON FRONT OF HOUSE TO SATISFACTION OFCLASS SOCIETY. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Deck/Cargo
Issued 1 June 1998 Resolved
REPAIR LEAK ON HATCH COVER WINCH. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Navigation
Issued 1 June 1998 Resolved
PROVE PROPER COMMUNICATION BETWEEN BRIDGE AND STEERING ROOM. CORRECTED
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Navigation
Issued 1 June 1998 Resolved
INSTALL ANTI-BACKING DEVICES ON ALL STEERING GEAR CONNECTIONS AND LINKAGES.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Navigation
Issued 1 June 1998 Resolved
REPAIR LEAK ON HYDRAULIC ACCUMALATOR FOR LOCAL MANUEL EMERGENCY STEERING. CORRECTED.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Fire Fighting
Issued 30 March 1998 Resolved
PROVIDE PROPER BRACKETS FOR FIRE EXTINGUISHER ADJACENT TO EMERGENCY FIRE PUMP.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Navigation
Issued 30 March 1998 Resolved
PROVIDE CURRENT COPY OF COAST PILOT. PROVIDE PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Navigation
Issued 30 March 1998 Resolved
PROVIDE CURRENT COPY OF LIGHT LIST, PRIOR TO NEXT U.S.PORT.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Unknown
Issued 30 March 1998 Resolved
REMOVE ALL FLAMMABLE MATERIAL FROM LOCKER NEXT TO CO2 LOCKER PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Lifesaving
Issued 30 March 1998 Resolved
PROVIDE SAFETY CHAIN ACROSS CARGO ESCAPE DOOR ON DECK PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Lifesaving
Issued 30 March 1998 Resolved
REPLACE ALL RETROTAPE ON RINGBUOY PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Accommodation/Occupational Safety
Issued 16 May 1997 Resolved
REPAIR RAILS ON 02 DECK STBD SIDE AT NEW BOX INSERT._x001C_ CORRECT PRIOR NEXT U.S. PORT.
Condition: Unknown
Due 16 May 1997
Resolved 10 June 1997
Documentation
Issued 16 May 1997 Resolved
PROVIDE PROPER MASTER LICENSE._x001C_ CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 16 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 10 April 1996 Resolved
LOADLINE PLIMSOL NOT PAINTED IN A CONTRASTING COLOR OF THE HULL.
Condition: Unknown
Due 12 April 1996
Resolved 30 May 1996
Documentation
Issued 10 April 1996 Resolved
FUEL OIL TRANSFER PROCEDURES NOT PROPERLY FORMATED IN LANGAGE UNDERSTOOD_x001C_ BY CREW.
Condition: Unknown
Due 12 April 1996
Resolved 30 May 1996
Lifesaving
Issued 10 April 1996 Resolved
ROCKETS FOR LINE THROWING APPARATUS ARE EXPIRED.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.