← All vessels
STELLA MARIS II
Freight Ship · Bulk Carrier class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named STELLA MARIS II
STELLA MARIS II is a 1976 freight ship. The Coast Guard has recorded 28 inspections since 1996, most recently in April 2016, along with 74 deficiencies and 2 operational controls.
Records from 1996 to 2016. Most recent: inspection, 5 April 2016.
- Built
- 1976
- Last inspected
- 5 April 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 74 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7413907 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
E5U2232
435773
Flag
COOK ISLANDS
—
Maury page id
psix-435773
Inspections, by type
…with no type recorded16
Years with a record
10 calendar years (1996–2016)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it1939 - Convention (Subpart B), Gross Ton
1087 - Convention (Subpart B), Net Ton
3022 - Dead Weight, Ton
1087 - Convention (Subpart B), Net Ton
3022 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
5 April 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5847842
14 March 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5832559
26 February 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5826454
5 January 2016
Deficiency Check · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5790959
3 December 2015
Deficiency Check · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5775038
13 November 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5763223
28 October 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5752401
28 September 2010
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3793910
28 September 2010
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3875306
20 September 2004
PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2199454
8 February 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 286962
6 January 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 285826
4 October 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 822631
9 June 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 279306
15 December 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 435790
7 September 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 432604
6 August 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 778041
21 June 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 429898
23 November 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 422904
30 June 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 417405
1 June 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 422483
15 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414886
30 March 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414230
1 July 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 24144
6 June 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 404474
16 May 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 403659
28 May 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 391652
10 April 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 389840
Deficiency record · 74
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 5 January 2016
Resolved
The LRIT Conformance Test Report shall be issued by vessel's flag in accordance with MSC1/CIRC. 1307. 74 SOLAS(14 Cons)Ch.V/Reg 19-1
Construction/Loadline › Structures › Superstructure
Issued 3 December 2015
Resolved
0956 - For all ships the means of embarkation and disembarkation shall be inspected and maintained in suitable condition. The gangway is out of working order due to a crack midway through it. 74SOLAS(14 cons.) Ch.II-1/Reg 3-9.3
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 October 2015
Resolved
0686-Before the ship leaves port all life saving appliances shall be in working order. The port side, aft lifebuoy, self-igniting light is inoperable. 74 SOLAS(14 Cons)Ch.III/Reg 20.2
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 October 2015
Resolved
2035-Fire control plans and booklets shall be kept up to date. The fire control plans still reflect the approval from the previous Administration. 74 SOLAS(14 Cons.)/Ch.II-2/Reg.15.2.4.1
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 28 October 2015
Resolved
0199-Equipment for Long Range Identification and Tracking(LRIT) of ships shall be approved by the Administration. Tanzania has not issued any documentation to the ship attesting to the conformance or LRIT requirments.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 September 2004
Resolved
Provide US Coast Pilot publication a receipt of purchase to be faxed to the office.
Navigation › Piloting/Steering › Gyro Compass
Issued 20 September 2004
Resolved
Provide Technical report attesting to the proper operation of gyro compass.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 20 September 2004
Resolved
Provide Emergency Escape Breathing Apparatus (SOLAS as ammended II-2/13.3.4). Class to verify location and make necessary annotations to the fire control plan & safety equipment certificate.
Electrical
Issued 6 January 2001
Resolved
INADEQUATE INSTALLATION OF ALL CARGO DECK SPOT LIGHTS ON UPPER BRIDGE. LIGHTS NEED JUNTION BOXES TO MAKE ELECTRICAL CONNECTION OR RUN WIRE TO END ENSIDE THE [name withheld].
Electrical
Issued 6 January 2001
Resolved
FIRST AND SECOND DECK SHOWER ROOM [name withheld] TO BE REPLACED FOR ONE WATERPROOF. FLUORESCENT [name withheld] TO A HIGH HUMIDITY ENVIROMENT.
Navigation
Issued 6 January 2001
Resolved
[name withheld] NEEDS TO BE REPLACED. LIGHT BLINKS ON AND OFF WHEN SWITCH IS IN ON POSITION.
Electrical
Issued 6 January 2001
Resolved
LIVE WIRES EXPOSED OUT OF A RECEPTICLE AT HOSPITAL ENTRANCE.
Navigation
Issued 6 January 2001
Resolved
RENEW OR UP-DATE THE APPROCHING CHART OF PUERTO RICO NUMBER 25640 AND SAN JUAN HARBOR CHART NUMBER 25670 PRIOR TO DEPARTURE.
Accommodation/Occupational Safety
Issued 6 January 2001
Resolved
REPAIR/REPLACE LADDER TO ITS ORIGINAL CONDITIONS AT STARBOARD SIDE BOW (TOACCESS FOXHOLE "ANCHOR DECK") TO THE SATISFACTION OF CLASS SOCIETY/ADMINISTRATION.
Electrical
Issued 6 January 2001
Resolved
REPAIR GENERATOR # 4 TO SATISFACTION OF CLASS/ADMINISTRATOR.
Electrical
Issued 6 January 2001
Resolved
REMOVE EXCESS WIRES CONNECTED TO THE EMERGENCIES BATTERIES PRIOR TO DEPARTURE.
Fire Fighting
Issued 6 January 2001
Resolved
PROVIDE MISSING NOZZLE TO FIRE STATION AT PORT SIDE AFT BOAT DECK PRIOR TO DEPARTURE.
Electrical
Issued 6 January 2001
Resolved
PORT NAVIGATION LIGHT WIRING HAS EXPOSED SECTION. REPAIR PRIOR TO DEPARTURE.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 January 2001
Resolved
WALL LIGHT FIXTURE IN CABIN 15 NEEDS TO BE REPLACED OR RE-INSTALL ORIGINAL [name withheld] ALL CREW CABINS FOR SAME REQUIREMENT.
Electrical
Issued 6 January 2001
Resolved
HOSPITAL BED LIGTH FIXTURE MISSING. LIVE WIRES EXPOSED.
Engineering
Issued 6 January 2001
Resolved
PROVIDE REPORT FROM CLASS SOCIETY ON THE MAIN ENGINE GOVERNOR PROPERLY OPERATION PRIOR TO DEPARTURE.
Fire Fighting
Issued 6 January 2001
Resolved
SERVICE EMPTY (2) FIRE EXTINGUISHERS (SMALL ONE IN THE BRIDGE AND BIG ONE PASSAGEWAY OUTSITE BRIDGE) PRIOR TO DEPARTURE.
Navigation
Issued 6 January 2001
Resolved
REPAIR INOPERABLE GMDSS TO SATISFACTION OF CLASS SOCIETY PRIOR TO DEPARTURE. GMDSS IS NOT WORKING SINCE NOV 2000.
Documentation
Issued 6 January 2001
Resolved
HAVE CLASS SOCIETY TO VERIFY VALIDITY OF SAFETY EQUIPMENT CERTIFICATE. SPACES LEFT IN BLANK (#'S OF LIFERAFTS) AND NUMBER OF PERSONS FOR WHICH LIFE-SAVING APPLIANCES ARE PROVIDED VS NUMBER OF PERSONS ON BOARD. HAVE CLASS REPORT FAX TO COAST GUARD PRIOR TO DEPARTURE.
Engineering
Issued 9 June 2000
Resolved
WIPE DOWN EXCESS OIL IN ENGINE ROOM AND GENERATOR ROOM PRIOR TO NEXT U.S. PORT.
Fire Fighting
Issued 9 June 2000
Resolved
STENCIL FIRE MAIN VALVE TO PAINT LOCKER PRIOR TO NEXT U.S. PORT.
Accommodation/Occupational Safety
Issued 9 June 2000
Resolved
REPAIR HANDRAIL AND LADDER ON STARBOARD BOW TO THE SATISFACTION OF CLASS NOLATER THAN 09 JULY 2000.
Documentation
Issued 9 June 2000
Resolved
PROVIDE UPDATED SAFE MANNING CERTIFICATE REFLECTING CHANGE IN GROSS TONNAGEFROM 1570 TO 1939 NO LATER THAN 09 JULY 00.
Documentation
Issued 9 June 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety
Issued 9 June 2000
Resolved
CLEAN GREASE TRAP IN GALLEY PRIOR TO NEXT U.S. PORT.
Lifesaving
Issued 9 June 2000
Resolved
PROVIDE HYDROSTATIC RELEASE FOR EPIRB PRIOR TO NEXT U.S. PORT.
Fire Fighting
Issued 9 June 2000
Resolved
PROVIDE MISSING FIRE HELMET FOR SECOND FIRE SUIT PRIOR TO NEXT U.S. PORT.
Navigation
Issued 9 June 2000
Resolved
REPAIR LEAK ON OIL LINE TO STEERING PUMP PRIOR TO NEXT U.S. PORT.
Construction/Loadline
Issued 21 June 1999
Resolved
CROP AND RENEW WASTED CEILING LOCATED IN A/C ROOM, IMMEDIATELY AT ENTRANCE AND NEXT TO LONGITUDINAL FRAME.
Lifesaving
Issued 21 June 1999
Resolved
PROVIDE AND OR REPLACE GASKETS FOR HATCHES #4, #5, #6, #11, #12, #13, #14, PORT AND STARBOARD WHERE MISSING. EXAMINE ALL OTHER CARGO HATCHES AND REPLACE/PROVIDE GASKETS AS NEEDED.
Fire Fighting
Issued 21 June 1999
Resolved
REPLACE SHOULDER STRAP FOR SCBA. (PARTED DURING FIRE DRILL)
Fire Fighting
Issued 21 June 1999
Resolved
REPAIR MINOR AIR LEAK NOTED AT SCBA AND MASK HOSE CONNECTION.
Lifesaving
Issued 21 June 1999
Resolved
PROVIDE SAFETY GUARD FOR ROTARY EQUIPMENT FOR EMERGENCY FIRE PUMP.
Lifesaving
Issued 21 June 1999
Resolved
PROPERLY REPLACE PORT SIDE HYDROSTATIC RELEASE. (IT WAS PAINTED OVER)
Lifesaving
Issued 21 June 1999
Resolved
RENEW RESCUE BOAT RETROREFLECTIVE TAPE.
Documentation
Issued 21 June 1999
Resolved
PROVIDE ALL VESSEL RELATED CERTIFICATES AND DOCUMENTS TO INCLUDE: LOADLINE CERTIFICATE, REGISTRY, SAFETY RADIO, IOPP, SAFETY CONSTRUCTION, SAFETY EQUIPMENT, ITC, SAFETY MANNING.
Documentation
Issued 21 June 1999
Resolved
PROPERLY AMEND SOLAS TRAINING MANUAL AS TO REFLECT THE USE OF THE RESCUE BOAT AND SHIPBOARD FIREFIGHTING EQUIPMENT .
Documentation
Issued 21 June 1999
Resolved
PROVIDE TANKS AND LINE PIPING DIAGRAM FOR OIL TRANSFER PROCEDURES.
Navigation
Issued 21 June 1999
Resolved
PROVIDE INMARSAT SCREEN FOR GMDSS. (UNIT ASHORE FOR REPAIRS)
Electrical
Issued 21 June 1999
Resolved
PROVIDE SUITABLE RUBBER MAT FOR GENERATOR SWITCHBOARD.
Fire Fighting
Issued 21 June 1999
Resolved
REPLACE DAMAGED SMOKE DETECTOR ABOVE STBD GENERATOR AND STBD SIDE FORWARD OF MAIN DIESEL ENGINE.
Navigation
Issued 21 June 1999
Resolved
MAKE PROPER CORRECTION TO RUDDER ANGLE INDICATOR'S DEGREE DIFFERENCES. (5 DEGREES TO PORT AND 2 DEGREES TO STBD)
Construction/Loadline
Issued 30 June 1998
Resolved
PROPERLY REPAIR CARGO BILGE DISCHARGE. CORRECT PRIOR TO NEXT U.S. PORT TO THE SATISFACTION OF CLASS.
Lifesaving
Issued 1 June 1998
Resolved
MAKE RESCUE BOAT READILY AVAILABLE WITH EQUIPMENT AND MOTOR. CORRECTED.
Documentation
Issued 1 June 1998
Resolved
PROVIDE CERTIFICATES OF COMPETENCY FOR 1ST ENGINEER AND ABLE BODIED SEAMAN TO SATISFACTION OF CLASS. CORRECTED.
Fire Fighting
Issued 1 June 1998
Resolved
RENEW GAUGE FOR EMERGENCY FIRE PUMP. CORRECTED.
Fire Fighting
Issued 1 June 1998
Resolved
RENEW FIRE DAMPERS/VENT CLOSURES ON HOUSE EXTERIOR TO SATISFACTION OF CLASSSOCIETY. CORRECTED.
Construction/Loadline
Issued 1 June 1998
Resolved
HAVE PORT SIDE STERN CORNER BULWARKS DAMAGE SURVEYED BY CLASS SOCIETY. CORRECTED.
Construction/Loadline
Issued 1 June 1998
Resolved
HAVE CLASS SURVEY HULL DAMAGE IN GENERATOR COMPARTMENT BETWEEN FRAMES 7 AND9. CLASS SURVEY DONE.
Construction/Loadline
Issued 1 June 1998
Resolved
PROVIDE CLOSURE DEVICES TO PREVENT DOWN FLOODING FOR ENGINEROOM GOOSE NECK VENT IN WAY OF PORT AND STARBOARD SIDE OF HOUSE ON 01 DECK. CORRECTED.
Lifesaving
Issued 1 June 1998
Resolved
PROVIDE LIFEBOAT OR SAFETY EXEMPTION CERTIFICATE FOR SAME AS PER SOLAS. CORRECTED.
Navigation
Issued 1 June 1998
Resolved
REPAIR RADAR SO IT CAN READ ABOVE 10 MILE RANGE. CORRECTED.
Fire Fighting
Issued 1 June 1998
Resolved
FREE UP AND DEMONSTRATE PROPER OPERATION OF FIRE DAMPER ON FORCED AIR VENTILATION BLOWER FOR ENGINE ROOM. CORRECTED.
Fire Fighting
Issued 1 June 1998
Resolved
FREE UP ENGINEROOM VENTILATOR CLOSURES ON FRONT OF HOUSE TO SATISFACTION OFCLASS SOCIETY. CORRECTED.
Deck/Cargo
Issued 1 June 1998
Resolved
REPAIR LEAK ON HATCH COVER WINCH. CORRECTED.
Navigation
Issued 1 June 1998
Resolved
PROVE PROPER COMMUNICATION BETWEEN BRIDGE AND STEERING ROOM. CORRECTED
Navigation
Issued 1 June 1998
Resolved
INSTALL ANTI-BACKING DEVICES ON ALL STEERING GEAR CONNECTIONS AND LINKAGES.
Navigation
Issued 1 June 1998
Resolved
REPAIR LEAK ON HYDRAULIC ACCUMALATOR FOR LOCAL MANUEL EMERGENCY STEERING. CORRECTED.
Fire Fighting
Issued 30 March 1998
Resolved
PROVIDE PROPER BRACKETS FOR FIRE EXTINGUISHER ADJACENT TO EMERGENCY FIRE PUMP.
Navigation
Issued 30 March 1998
Resolved
PROVIDE CURRENT COPY OF COAST PILOT. PROVIDE PRIOR TO NEXT U.S. PORT.
Navigation
Issued 30 March 1998
Resolved
PROVIDE CURRENT COPY OF LIGHT LIST, PRIOR TO NEXT U.S.PORT.
Unknown
Issued 30 March 1998
Resolved
REMOVE ALL FLAMMABLE MATERIAL FROM LOCKER NEXT TO CO2 LOCKER PRIOR TO NEXT U.S. PORT.
Lifesaving
Issued 30 March 1998
Resolved
PROVIDE SAFETY CHAIN ACROSS CARGO ESCAPE DOOR ON DECK PRIOR TO NEXT U.S. PORT.
Lifesaving
Issued 30 March 1998
Resolved
REPLACE ALL RETROTAPE ON RINGBUOY PRIOR TO NEXT U.S. PORT.
Accommodation/Occupational Safety
Issued 16 May 1997
Resolved
REPAIR RAILS ON 02 DECK STBD SIDE AT NEW BOX INSERT._x001C_ CORRECT PRIOR NEXT U.S. PORT.
Documentation
Issued 16 May 1997
Resolved
PROVIDE PROPER MASTER LICENSE._x001C_ CORRECT PRIOR TO DEPARTURE.
Construction/Loadline
Issued 10 April 1996
Resolved
LOADLINE PLIMSOL NOT PAINTED IN A CONTRASTING COLOR OF THE HULL.
Documentation
Issued 10 April 1996
Resolved
FUEL OIL TRANSFER PROCEDURES NOT PROPERLY FORMATED IN LANGAGE UNDERSTOOD_x001C_ BY CREW.
Lifesaving
Issued 10 April 1996
Resolved
ROCKETS FOR LINE THROWING APPARATUS ARE EXPIRED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.