Records from 2005 to 2026. Most recent: inspection, 16 June 2026.
Inspection history · 29
16 June 2026
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8358171
22 September 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8239026
25 June 2025
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8097049
23 June 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8111792
12 June 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7909494
1 April 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7888120
16 September 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7780291
8 June 2023
In-Service Inspection · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7710082
31 May 2023
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7659400
23 March 2023
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7636774
23 March 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654634
14 March 2023
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651980
12 January 2023
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7622286
7 January 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7608003
24 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7470942
13 August 2021
Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7307468
12 August 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7322250
21 June 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7233085
11 May 2021
Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7200412
23 June 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6984575
10 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6816103
11 June 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6628383
28 March 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6628391
29 July 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6498305
9 March 2018
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6369232
8 March 2017
Deficiency Check · Hull Examination · DAPI Audit · Examination of Repairs · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6099598
18 April 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5856623
4 April 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5845341
30 March 2016
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5820506
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 June 2026
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Both port and starboard fwd heads are missing interconnected smoke detection. Wheel house smoke detector is not interconnected with others.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2026
Resolved 25 June 2026
Resolution: Satisfactory test of smoke detectors witnessed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2026
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Stern light is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2026
Resolved 7 July 2026
Resolution: Light repaired.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 June 2026
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2026
Resolved 7 July 2026
Resolution: Updated certificate onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 22 September 2025
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. One of 3 float lights for lifefloats do not work.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2025
Resolution: Receieved photos showing the purchase and installation of float light.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 June 2024
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic release for EPIRB expired May 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2024
Resolution: Received photograph showing deficiency was corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 June 2024
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Contents of the first aid kit are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2024
Resolution: Received photograph showing deficiency was corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 June 2024
Resolved
One ship station license will be granted for operation of all maritime services transmitting equipment on
board a vessel. Radiotelegraph and narrow-band directing-printing equipment will not be authorized,
however, unless specifically requested by the applicant. FCC Station License expired 20FEB2022. 46CFR80.13
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2024
Resolution: Received photograph showing deficiency was corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 23 March 2023
Resolved
(a)A grease extraction hood required by 46 CFR 181.400 must meet UL 710 (incorporated by reference, see 46 CFR 175.600) or other standard specified by the Commandant.
(b)A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A (both incorporated by reference, see 46 CFR 175.600), or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. Vessel has installed griddle with no extraction hood. Vessel is to lockout/tagout the griddle and submit plans for installation of above grease extraction hood with fire extinguishing system. 46 CFR 181.425
Action required: 705 - Other - as specified
Resolved 18 January 2024
Resolution: Owner installed Hoodmart Concession Trailer with Fire Suppression
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 June 2022
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The paddles for one of the life floats were found to be deteriorated and no paddles were lashed to their life floats. Additionally, one float free weak link was missing its tag.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 11 July 2022
Resolution: O/O Replaced deteriorated paddles and outfitted lifefloats properly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2022
Resolved
A vessel at anchor shall exhibit (during daytime hours) where it can best be seen one ball day shape. The vessel could not produce a day shape.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 11 July 2022
Resolution: O/O provided new day shape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2022
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted. The port side fuel shutoff valve was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 24 June 2022
Resolution: Crewmembers were able to repair and prove proper operation of port side fuel shutoff valve prior to the completion of the inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 10 October 2019
Resolved
NEW INSTALLATIONS OF MATTRESSES MUST MEET US DEPARTMENT OF COMMERCE FF 4-72.16 OR IMO A.688(17). PROVE MATERIALS USED IN NEW MATTRESSES MEET STANDARDS OR REPLACE WITH MATTRESSES THAT DO.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 12 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 October 2019
Resolved
All electrical shall be of a type designed for the potential involved and so identified. Identify and label four breakers missing labels in galley electrical panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 15 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2019
Resolved
Life jackets required CG approved lights for Oceans route. Found 10 life jackets missing attached light.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2019
Resolved 24 June 2019
Resolution: Provide 10 and installed CG approved lights.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 March 2018
Resolved
PROVIDE SERVIVING REPORT FOR INSTALLED FIXED GAS FIRE EXTINGUISHING SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46CFR176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2018
Resolution: Vessel provided satisfactory proof of fire servicing.
Stability › Watertight Integrity › General
Issued 26 March 2018
Resolved
PROVIDE MEANS TO PREVENT WATER INGRESS ON ALL THRU-HULL PIPING 6-INCHES ABOVE WATERLINE IN FWD COMPARTMENT. 46CFR171.119(b) OLD T
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 9 April 2018
Resolution: All thru-hulls at the waterline were either capped or had valves installed.
Engineering › Bilge Water Management System › Valve
Issued 26 March 2018
Resolved
PROVIDE SCREW DOWN VALVE ON BILGE PIPING FWD OF COLLISION BULKHEAD. TO BE OPERABLE FROM ABOVE THE WEATHER DECK. 46CFR182.25-5(d) OLD T
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 16 April 2018
Resolution: Screwdown valve installed aft of the collision bulkhead.
Lifesaving › Lifefloat › Markings
Issued 26 March 2018
Resolved
REFINISH LIFEFLOAT IN ACCORDANCE W/MANUFACTURER'S SPECIFICATIONS. 46CFR180.200(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 9 April 2018
Resolution: Lifefloats were repaired/recolored.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 March 2018
Resolved
Complete satisfactory renewal inspection for COI. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2018
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 24 April 2017
Resolved
Provide ventilation installation for the lazarette.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 17 May 2017
Resolution: Gooseneck vent installed within aft ventilation structure on main deck, all satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2017
Resolved
Provide repair proposal for transom planking wood rot, upper two planks on stbd quarter intersection.
Action required: 705 - Other - as specified
Resolved 1 May 2017
Resolution: Repairs completed, see narrative.
Construction/Loadline › Hull › Hull Plating
Issued 19 April 2017
Resolved
Recaulk all areas identified.
Action required: 705 - Other - as specified
Resolved 24 April 2017
Resolution: See Narrative
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 April 2017
Resolved
Make stbd side of lazarette/fuel tank space bulkhead watertight.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 April 2017
Resolution: See Narrative
Construction/Loadline › Hull › Hull Plating
Issued 19 April 2017
Resolved
Re-fasten stbd chine, into each frame.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 April 2017
Resolution: See Narrative
Construction/Loadline › Hull › Stiffener
Issued 19 April 2017
Resolved
Insert vertical stiffener in stbd quarter, lazarette space.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 April 2017
Resolution: See Narrative
Construction/Loadline › Hull › Transverse Frame
Issued 19 April 2017
Resolved
Renew deck beams - in fuel tank space, identified aft 4 deck beams in wasted condition, and deck beam #6 in same space, numbering starting aft in space.
Action required: 705 - Other - as specified
Resolved 1 May 2017
Resolution: See Narrative
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 April 2017
Resolved
Make bulkhead watertight between fuel tank space and engine room port side bottom.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 April 2017
Resolution: See Narrative
Construction/Loadline › Hull › Hull Plating
Issued 19 April 2017
Resolved
Conduct satisfactory underway sea trial.
Action required: 705 - Other - as specified
Resolved 3 May 2017
Resolution: See Narrative
Construction/Loadline › Hull › Hull Plating
Issued 8 March 2017
Resolved
Vessel must conduct permanent hull/chine repairs to regain watertight integrity, vessel suffering leaks through chine in engine room stbd side, lazarette both port & stbd sides. Vessel not authorized to carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2017
Resolution: Vessel repairs completed, see narrative.
Lifesaving › Lifefloat › Float Free
Issued 8 March 2017
Resolved
Provide a weaklink and 100 foot painter line for the forward lifefloat, and two proper weaklinks for the two aft lifefloats, limited to lakes, bays, & sounds route, no more than one mile from shore within this route until provided.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 31 March 2017
Resolution: Items provided/corrected per the description above.
Communications › Radio Communications › EPIRB
Issued 8 March 2017
Resolved
Limited to no more than three miles from mainland shore until EPIRB hydrostatis release unit is valid.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 31 March 2017
Resolution: New EPIRB hydrostatic release unit provided, valid until 2019.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 8 March 2017
Resolved
Vessel restricted to voyages less than 12 hours, until cameron green and john jordan are verified to be subject to random drug testing, may not serve as crewmembers with safety sensitive duties.
Action required: 705 - Other - as specified
Resolved 3 May 2017
Resolution: Observed both drug and alcohol crew list enrollment and proof of license for alternate licensed mate, all satisfactlry.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 March 2017
Resolved
Provide functional stern light, restricted to daytime operations only in good visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 March 2017
Resolution: Stern light wiring found loose and saturated, wiring replaced, functional, all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 8 March 2017
Resolved
Provide up-to-date nautical navigation charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 31 March 2017
Resolution: Proper valid charts provided, all sat.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 March 2017
Resolved
Install independent modular smoke detector unit in the forward bunk space, meeting U.L. 217., bunk space may not be used until provided.
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 31 March 2017
Resolution: Items provided/corrected per the description above.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 4 April 2016
Resolved
Replace retroreflective tape on (9) lifejackets as ID'd.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Retroreflective tape replaced on ID'd lifejackets.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 April 2016
Resolved
Label lifering with vessel name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Lifering correctly labeled.
Lifesaving › Lifefloat › Serviceable
Issued 4 April 2016
Resolved
Replace (1) life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: New lifefloat installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 April 2016
Resolved
Provide Machinery Guard on (3) items as ID'd.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Machinery guards installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 30 March 2016
Resolved
Complete annual servicing of firefighting equipment and provide servicing report.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Received service report tested engine and generator shutdowns
Construction/Loadline › Hull › Transverse Frame
Issued 30 March 2016
Resolved
Remove rot from Frame #3 forward of the transom at the deck beam IWO the deck clamp.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 18 April 2016
Construction/Loadline › Hull › Stringer
Issued 30 March 2016
Resolved
Replace rotted deck beam in fuel tank room forward of aft bulkhead
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 18 April 2016
Construction/Loadline › Hull › Transverse Frame
Issued 30 March 2016
Resolved
Repair 3 cracked deck supports located portside void accomdation space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 18 April 2016