MAURY USCG vessel records Sign in
← All vessels

EQUINOX

EQUINOX is a 1995 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1996, most recently in April 2026, along with 106 deficiencies and 2 casualty investigations between 2005 and 2019.

Records from 1996 to 2026. Most recent: inspection, 2 April 2026.

Built
1995
Last inspected
2 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG7760
435791
Flag
UNITED STATES
367570560
Maury page id
psix-435791

Inspections, by type

…with no type recorded5
Years with a record 28 calendar years (1996–2026)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)39.1 ft × 13.6 ft × 6.3 ft
Registered tonnagegross 22 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYOUNG BROTHERS & COMPANY · COREA, ME, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCAMDEN, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG7760MMSI 367570560 · active · compulsorily equipped · granted 15 April 2023, expires 17 April 2033
WDB3211MMSI 366884630 · expired · voluntarily equipped · granted 11 March 2003, cancelled 11 May 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 51

2 April 2026 Plan Review "T" Boat · Examination of Repairs · Vessel Attendance
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8345815
26 March 2026 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8332227
24 March 2025 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8092748
12 November 2024 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8033347
7 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8032057
14 May 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7912361
2 February 2023 COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7631309
26 September 2022 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7566458
9 May 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7446907
23 November 2021 Examination of Repairs · Construction Oversight
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7356445
5 April 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7168816
13 October 2020 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7075847
6 August 2020 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7030726
13 July 2020 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7004775
4 June 2020 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6968068
27 November 2019 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6864084
26 November 2019 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6868890
29 May 2019 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6697225
30 April 2019 Examination of Repairs · Plan Review "T" Boat
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6673376
24 October 2018 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6561476
7 March 2018 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6353987
22 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6152278
7 October 2016 Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6018181
19 May 2016 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5870016
24 April 2016 Type not recorded
No type recorded · USCGC MORAY (WPB 87331) · USCG Southeast District (CGD-SE) · Activity 5862454
23 July 2015 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5193272
7 October 2014 Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5002529
29 May 2014 Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4872939
10 January 2011 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3924146
29 March 2010 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3704844
27 March 2009 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3441408
27 January 2009 Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3400861
13 March 2008 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3163071
8 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2924876
25 January 2007 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2861744
18 January 2007 Type not recorded
No type recorded · Station Rockland · USCG Northeast District (CGD-NE) · Activity 2858154
31 May 2006 Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2666227
28 July 2005 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2451060
23 March 2005 Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2321173
9 February 2005 Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2308036
29 April 2004 Re-Inspection · Simplified Stability Test
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2055095
27 February 2003 COI Inspection · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1750141
5 June 2001 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1066660
21 September 2000 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1053681
19 June 2000 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 819197
28 June 1999 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1442856
3 September 1998 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 800054
25 August 1998 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 796783
22 June 1998 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1433344
20 August 1997 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1390612
28 June 1996 Plan Review "T" Boat · COI Inspection · Inclining Experiment · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1367845

Deficiency record · 106

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 April 2026 Resolved
Found stbd fuel tank leaking, repair replace per approved fuel tank drawing.
Action required: 705 - Other - as specified
Due 15 April 2026
Resolved 22 April 2026
Resolution: New fuel tank installed
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 June 2024 Resolved
Provide valid FCC Safety Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 10 June 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 June 2024 Resolved
Provide HRU for EPIRB (unexpired). Vessel restricted to operating not more than 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 3 July 2024
Resolved 13 June 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 June 2024 Resolved
Prove valifity of battery date for EPIRB. Vessel restricted to operating not more than 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 3 July 2024
Resolved 13 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 June 2024 Resolved
Provide servicing for IBA. Vessel restricted to carrying not more than 24 persons until corrected.
Action required: 705 - Other - as specified
Due 3 July 2024
Resolved 6 June 2024
Resolution: Received service report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2024 Resolved
Provide 18' floating waterlight lines for Lifefloat and BA.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 10 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2023 Resolved
Prove operation of Bilge Pump Energized indicators at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 6 December 2023
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 15 May 2023 Resolved
Repair port aft and port mid rail stanchions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 6 December 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2023 Resolved
Install plug on bottom of racor filter petcock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 25 May 2023
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 May 2023 Resolved
Renew Navigation publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2023
Resolved 12 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 May 2022 Resolved
Install lagging/insulation on dry exhaust muffler.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 15 September 2022
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 May 2022 Resolved
Adjust engine room ventilation damper so that it fully closes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 21 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2021 Resolved
Provide details of new muffler installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 11 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2021 Resolved
Prove operation of forward bilge pump indicator lamp.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 13 May 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 4 May 2021 Resolved
Replace expired Alco-test kits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 11 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 4 May 2021 Resolved
Provide new FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 24 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 June 2020 Resolved
Provide FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2020 Resolved
Prove operation of port fuel shutoff access hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2020 Resolved
Install metallic plug on racor petcock.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 13 July 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 November 2019 Resolved
Operator noted damage to fiberglass from Bump and Go. Vessel was taken out of water following steering casualty.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2019
Resolved 5 December 2019
Resolution: Repairs completed by builder.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2019 Resolved
Steering bolts on collar sheered off during operation. Vessel shall conduct underway test to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2019
Resolved 5 December 2019
Resolution: Steering bolts replaced and new bolts installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 29 May 2019 Resolved
Provide a valid MMC and Medical cert. Owner tried show bad photo copies of his MMC during the Annual Inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 28 June 2019
Resolution: Done
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 29 May 2019 Resolved
Provide a list of covererd employees for the DAPI program from the constortuim used.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 28 June 2019
Resolution: Done
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Investigation after accident
Issued 29 May 2019 Resolved
Provide approved salvia testing strips to comply with USCG regs for alcohol testing for an SMI casualty.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 18 June 2019
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Label the electrical ciruits in the pilothouse. Swap the Radar and the GPS circuit breakers to provide adequate protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 28 June 2019
Resolution: Corrected.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 7 March 2018 Resolved
Provide a valid MMC, photocopies are not accepted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2018
Resolution: Corrected
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 7 March 2018 Resolved
Master to provide a valid FCC Radio Ops permit
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 9 April 2018
Resolution: Corrected
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 March 2018 Resolved
Provide a indicator for the different bilge alarms
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 16 May 2018
Resolution: Corrected
Fire Fighting › Fire Bucket › Availability
Issued 7 March 2018 Resolved
Provide the correct number & size fire buckets
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 23 April 2018
Resolution: Cleared
Lifesaving › Lifebuoys › Serviceable
Issued 7 March 2018 Resolved
Replace the ring buoy; existing was worn and unservicable.
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 23 April 2018
Resolution: Corrected
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 March 2018 Resolved
Replace the floating line to the ring buoy.
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 23 April 2018
Resolution: Corrected
Lifesaving › Lifefloat › Lifeline
Issued 7 March 2018 Resolved
Replace the line for the waterlights going to the life float & the BA.
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 16 May 2018
Resolution: Corrected
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2017 Resolved
Prove operation of high level audible alarm.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 27 June 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2017 Resolved
Label high level aram.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 27 June 2017
Communications › Alarms/Indicators › High Water Alarm
Issued 6 June 2017 Resolved
Replace high level float switch in the lazaret (sticking).
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: O/O advised unit is repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 7 October 2016 Resolved
The stern tube cutlass bearing was showing wear on the bottom side of shaft. Operator to replace or re-check for continued operation in 01 year.
Action required: 705 - Other - as specified
Due 7 October 2017
Resolved 24 October 2018
Resolution: Cleared 835, unable to edit existing 835.
Construction/Loadline › Hull › Sheerstrake
Issued 7 October 2016 Resolved
The stbd gunwale/washboard area where pax step on to embark/disembark showed signs of water retention. O/O to submit a proposed plan for repairs.
Action required: 705 - Other - as specified
Due 22 November 2016
Resolved 22 November 2016
Resolution: Removed 835 & added a special note to continue to monitor this area.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 October 2016 Resolved
The batteries located in the fwd cabin, underneath the step were showing signs of overheating & distortion. Vsl to replace both batteries with similar size & type.
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 22 November 2016
Resolution: New batteries installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 May 2016 Resolved
Replace floating waterlight batteries.
Due 20 May 2016
Resolved 20 June 2016
Resolution: Attended vessel. Batteries renewed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2016 Resolved
Replace expired aspirin.
Due 19 June 2016
Resolved 20 June 2016
Resolution: Attended vessel. New aspirin onboard.
Stability › Incline Test › General
Issued 19 May 2016 Resolved
Post latest stability letter/addendum.
Due 19 June 2016
Resolved 20 June 2016
Resolution: Attended vessel. Stability letter posted.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 May 2016 Resolved
Provide valid FCC safety certificate.
Due 19 June 2016
Resolved 20 June 2016
Resolution: Attended vessel. Certificate onboard.
Documentation › Certificates/Documents › FCC SSL
Issued 19 May 2016 Resolved
Provide MROP.
Due 19 June 2016
Resolved 20 June 2016
Resolution: Attended vessel. valid MROP onboard.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 May 2016 Resolved
Replace flashlight batteries.
Due 19 June 2016
Resolved 20 June 2016
Resolution: Attended vessel. Batteries replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 May 2016 Resolved
Provide visual indication of high level alarm.
Due 19 June 2016
Resolved 20 June 2016
Resolution: Attended vessel. Visual indiocator (led light) now in place
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 May 2016 Resolved
Conduct u/w drills with USCG Inspector.
Due 19 June 2016
Resolved 20 June 2016
Resolution: Attended vessel. Drills conducted satisfactory.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 July 2015 Resolved
Found vessel COD has expired on the 30 June 2015, o/o to provide valid document prior to operating vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 August 2015
Resolved 7 August 2015
Resolution: Document issued effective to expire 8/31/2016
Engineering › Diesel Engine (propulsion-reduction gear) › Camshaft
Issued 8 October 2014 Resolved
Oil analysis was conducted in fall and discovered metal shavings in oil sample. Repair / replace provide tech report on cause / operation.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 13 October 2014
Resolution: Repairs to engine were made, tech and owner power trails completed, engine operates as advertised.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 May 2014 Resolved
Provide list of covered employees for drug and alcohol program.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 10 June 2014
Resolution: Received list of covered employees for drug & alcohol program.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 May 2014 Resolved
Starboard navigation light lens is frosted/hazy and requires replacement.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 10 June 2014
Resolution: New starboard navigation light lens installed. All sat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 29 May 2014 Resolved
Escape hatch in cabin top to open deck is not properly marked as emergency escape.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 24 June 2014
Resolution: Witnessed proper marking of escape hatch in forward accommodation space cabin top.
Construction/Loadline › Structures › Deck Plating
Issued 29 May 2014 Resolved
Submit repair proposal for delaminated area of deck forward of cabin top. Repair proposal shall be submitted prior to next hull exam.
Action required: 705 - Other - as specified
Due 15 October 2014
Resolved 19 October 2014
Resolution: Received repair proposal for delaminated area of deck forward of the cabin top.
Engineering › Bilge Water Management System › Pump
Issued 29 May 2014 Resolved
Engine space electrical bilge pump in-operable. Repair/replace electric bilge pump. Bilge pump is an additional pump for this space and located forward of engine.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 22 June 2014
Resolution: Engine space electrical bilge pump switch replaced. Ops test of pump complete with not issues noted.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 29 May 2014 Resolved
Apply new retro-reflective tape and complete repairs to buoyant apparatus. Several rips in the foam material noted during inspection.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 22 June 2014
Resolution: Witnessed new retro-reflective tape applied and repairs completed to buoyant apparatus.
Stability › Watertight Integrity › General
Issued 10 January 2011 Resolved
Seal through hole in aft engine room bulkhead.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 24 January 2011
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 29 March 2010 Resolved
Provide valid FCC safety certificate
Condition: Invalid
Due 30 April 2010
Resolved 7 May 2010
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 29 March 2010 Resolved
Provide covers for engine room vents.
Condition: Improper Installation
Due 30 April 2010
Resolved 7 May 2010
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 March 2010 Resolved
Provide lifejacket donning placard for childs PFD's.
Condition: Improper Installation
Due 30 April 2010
Resolved 30 March 2010
Engineering › Fuel Oil Service System › Valve
Issued 27 March 2009 Resolved
Discuss with local marine inspector installation of emergency fuel shut-off from main fuel tanks. The fuel oil shut -off valve arrangement has been modified from original design.
Action required: 705 - Other - as specified
Due 27 April 2009
Resolved 7 April 2009
Engineering › Fuel Oil Service System › Valve
Issued 27 March 2009 Resolved
Provide an emergency fuel supply shut off and label at each (2) fuel tanks.
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 12 June 2009
Resolution: Shutoffs installed at the tank (ball valves).
Engineering › Bilge Water Management System › Interface Detector
Issued 13 March 2008 Resolved
High level bilge alarm in lazarette is not working. Owner must prove proper operation of the alarm to the satisfaction of the attending marine inspector by specified date.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 31 March 2008
Resolution: Demonstrated proper operation of all high level alarms on the vessel. Cleared deficiency.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 28 March 2005 Resolved
Install fixed fire extinguisher I.A.W. 46 CFR 181.400(a)(5)(ii): the applicator shall be installed in a fixed posiion so as to discharge into the space protected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2005
Resolved 23 June 2005
Fire Fighting › Fire Bucket › Quantity
Issued 23 March 2005 Resolved
Vessel's third fire bucket required to be marked I.A.W. 46CFR181.610: the words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket.
Condition: Unknown
Due 23 April 2005
Resolved 23 March 2005
Resolution: Deficiency corrected on site.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 March 2005 Resolved
Install navigational lights I.A.W. U.S. Coast Guard Navigational Rule 23: A power-driven vessel underway shall exhibit a masthead light forward, sidelights, and a sternlight. The "Masthead light" must show an unbroken light over an arc of the horizon of 255 degrees and so fixed as to show the light from right ahead to 22.5 degrees abaft the beam on either side of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 6 April 2005
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 23 March 2005 Resolved
Affix SOLAS approved retroreflective tape on the life rings I.A.W. 46CFR 185.604(i): each ring life buoy must be marked with Type II retroreflective material.
Condition: Unknown
Due 23 April 2005
Resolved 23 March 2005
Resolution: Corrected on site.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 23 March 2005 Resolved
Mount passenger seating I.A.W. 46 CFR 177.820(4): seats must be secured to the deck, bulkhead or bulwark.
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 6 April 2005
Fire Fighting › Miscellaneous Items
Issued 29 April 2004 Resolved
Properly mark fire buckets.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 10 May 2004
Documentation › Certificates/Documents
Issued 29 April 2004 Resolved
Post Certificate of Inspection and Stability letter. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 10 May 2004
Fire Fighting › Miscellaneous Items
Issued 29 April 2004 Resolved
Install a smoke detector in the forward compartment. U.L. approved for recreational vehicles.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 10 May 2004
Lifesaving › Buoyant Apparatus
Issued 29 April 2004 Resolved
Properly mount bouyant apparatus in a float free arrangement. This item has been temporarily corrected.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 10 May 2004
Operations/Management › Pollution
Issued 29 April 2004 Resolved
Clean diesel fuel out of steering space bilges.
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 10 May 2004
Communications › Radio Communications
Issued 27 February 2003 Resolved
Provide proof of EPIRB registration. Vessel is limited to less than 3 miles from land until this item is corrected. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 26 April 2003
Resolved 31 March 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 27 February 2003 Resolved
Make operable the engine room fixed fire extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 27 February 2003 Resolved
Permanently mount on deck seating.
Action required: 705 - Other - as specified
Due 26 April 2003
Resolved 31 March 2003
Operations/Management › Drug and Alcohol Testing
Issued 27 February 2003 Resolved
Provide a drug testing program for the vessel.
Action required: 705 - Other - as specified
Due 26 April 2003
Resolved 28 April 2003
Engineering
Issued 27 February 2003 Resolved
Make operable the bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 February 2003 Resolved
Update first aid kit.
Action required: 705 - Other - as specified
Due 26 April 2003
Resolved 31 March 2003
Communications › Radio Communications
Issued 27 February 2003 Resolved
Post an emergency broadcast placard.
Action required: 705 - Other - as specified
Due 26 April 2003
Resolved 31 March 2003
Lifesaving
Issued 21 September 2000 Resolved
PROVIDE STORAGE FOR PFD AND PROVIDE REQUIRED RAILINGS
Condition: Unknown
Due 21 October 2000
Resolved 26 March 2003
Lifesaving
Issued 21 September 2000 Resolved
PROPERLY MOUNT BUOYANT APPARATUS
Condition: Unknown
Due 28 September 2000
Resolved 26 March 2003
Engineering
Issued 21 September 2000 Resolved
INSTALL REMOTE SHUTOFF VALVE IN LPG SUPPLY LINE
Condition: Unknown
Due 21 October 2000
Resolved 20 November 2000
Fire Fighting
Issued 21 September 2000 Resolved
PROVIDE FIRE DETECTION SYSTEM IAW 46CFR 181.400(C)
Condition: Unknown
Due 28 September 2000
Resolved 20 November 2000
Documentation
Issued 21 September 2000 Resolved
PROVIDE COPY OF CHEMICAL TESTING CONTRACT
Condition: Unknown
Due 21 October 2000
Resolved 18 October 2000
Fire Fighting
Issued 21 September 2000 Resolved
PROVIDE FIXED FIRE FIGHTING SYSTEM TO MEET REQUIREMENTS OF 46CFR 181.400
Condition: Unknown
Due 28 September 2000
Resolved 2 November 2000
Documentation
Issued 21 September 2000 Resolved
PROVIDE COPY OFF FCC SAFETY CERTIFICATE
Condition: Unknown
Due 21 October 2000
Resolved 18 October 2000
Lifesaving
Issued 21 September 2000 Resolved
RENEW EPIRB HYDROSTATIC RELEASE
Condition: Unknown
Due 28 September 2000
Resolved 18 October 2000
Construction/Loadline
Issued 21 September 2000 Resolved
PROVIDE OPERABLE LAZERETTE BILGE ALARM
Condition: Unknown
Due 28 September 2000
Resolved 17 October 2000
Documentation
Issued 21 September 2000 Resolved
PROVIDE COPY OF OPERATORS LICENSE
Condition: Unknown
Due 28 September 2000
Resolved 26 October 2000
Construction/Loadline
Issued 21 September 2000 Resolved
FIX BILGE HIGH WATER ALARM LIGHTS ON CONSOLE
Condition: Unknown
Due 28 September 2000
Resolved 17 October 2000
Lifesaving
Issued 25 August 1998 Resolved
PROVIDE PROOF OF REGISTRATION FOR THE INSTALLED EPIRB.
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Lifesaving
Issued 25 August 1998 Resolved
RENEW FLOAT FREE BRACKET FOR THE INSTALLED EPIRB. RELEASE HAS EXPIRED.
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Engineering
Issued 22 June 1998 Resolved
Replace flame screen on fuel tank vent.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 22 June 1998 Resolved
Properly enclose two wires located in the lazerette IAW 46 CFR 183.340.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Documentation
Issued 20 August 1997 Resolved
PROVIDE PROPER DOCUMENTATION OF FULLY COMPLIANT CHEMICAL TESTING PROGRAM FOR THE FOLOWING DEFICIENCIES: (1) COPY OF CONTRACT, (2) PROVIDE PROVISIONSFOR RANDOM TESTING (3) PROVIDE INFORMATION ON THE EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Lifesaving
Issued 20 August 1997 Resolved
Perform underway boat drill and fire drill in the presence of a USCG MarineInspector.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Lifesaving
Issued 20 August 1997 Resolved
REFASTEN THE B/A SO THAT IT IS IN A FLOAT FREE ARRANGEMENT.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Documentation
Issued 20 August 1997 Resolved
UPDATE CERTIFICATE OF DOCUMENTATION TO REFLECT THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Navigation
Issued 20 August 1997 Resolved
MAKE CORRECTIONS TO CHARTS, LIGHT LISTS, COAST PILOT. PROVIDE A COPY OF THE NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Fire Fighting
Issued 20 August 1997 Resolved
REMOUNT B-I PORTABLE FIRE EXTINGUISHER SO THAT IT IS EASILY ACCESSIBLE FOR USE.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Construction/Loadline
Issued 20 August 1997 Resolved
INSTALL A SECURING DEVICE FOR ALL WATERTIGHT HATCHS LOCATED IN THE MAIN DECK AS REQUIRED BY 46 CFR 179.360.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Lifesaving
Issued 20 August 1997 Resolved
PLACE A FLOATABLE LINE ON WATERLIGHT IN COMPLIANCE WITH 46 CFR PART 176.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Lifesaving
Issued 20 August 1997 Resolved
PLACE A FIRST AID KIT ON BOARD THAT MEET UUSCG MINIMUM REQUIREMENTS FOR A SMALL PASSENGER VESSEL
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Documentation
Issued 20 August 1997 Resolved
POST STABILITY LETTER AS REQUIRED BY USCG REGULATION.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Documentation
Issued 20 August 1997 Resolved
POST EMERGENCY CHECK-OFF LIST IAW 46 CFR 185.512
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Lifesaving
Issued 20 August 1997 Resolved
INSTALL A WEAK LINK FOR THE B/A THAT MEETS THE REQUIREMENTS IN 46 CFR 160.073.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Documentation
Issued 20 August 1997 Resolved
PROVIDE DOCUMENTATION OF THE PAYMENT OF THE USER FEE.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997

Casualty record · 2

28 July 2005Routine · role: Involved in a Marine Casualty · activity 2451060
26 November 2019Routine · role: Involved in a Marine Casualty · activity 6868890
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.