Records from 1996 to 2005. Most recent: inspection, 3 December 2005.
Inspection history · 17
3 December 2005
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2545478
7 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2328996
4 October 2004
ISPS II Exam · COC-TVE Renew
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2212623
22 July 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 280004
22 July 2000
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 819770
21 October 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 421533
9 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 413561
8 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 752
12 February 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 412661
8 January 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 154419
8 October 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 408587
24 February 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 400954
28 January 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 399807
19 October 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 396843
19 October 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163750
6 February 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 387535
5 February 1996
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1188753
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 2 October 2004
Resolved
VSL MUST PROVE PROPER OPERATION OF 02 ANALYZER AND PROVIDE CLASS REPORT.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2004
Resolution: VSL PROVED PROPER OPERATION OF 02 ANALYZER AND PROVIDED CLASS REPORT.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 2 October 2004
Resolved
VSL MUST PROVIDE A CERTIFICATE ATTESTING TO THE CONTENTS OF O2 ANALYZER BOTTLE
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2004
Resolution: VSL PROVIDED A CERTIFICATE ATTESTING TO THE CONTENTS OF 02 ANALYZER BOTTLE.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 2 October 2004
Resolved
VSL MUST PROVE PROPER OPERATION OF GAS REGULATING VALVE AND PROVIDE CLASS REPORT . VALVE SHOULD AUTOMATICALLY ADJUST GAS FLOW.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2004
Resolution: VSL PROVED PROPER OPERATION OF GAS REGULATING VALVE AND PROVIDED CLASS REPORT.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 2 October 2004
Resolved
VSL MUST PROVE PROPER OPERATION OF INERT GAS SYSTEM ALARMS AND SHUTDOWN AND PROVIDE CLASS REPORT.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2004
Resolution: VSL PROVED PROPER OPERATION OF IGS ALARMS AND SHUTDOWN AND PROVIDED CLASS REPORT.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 2 October 2004
Resolved
VSL MUST PERMANENTLY REPAIR LEAKING SIGHT GLASS ON PORT AND STARBOARD SLOP TANKS AND PROVIDE CLASS REPORT.
Action required: 15 - Rectify deficiencies by next port
Resolved 3 October 2004
Resolution: VSL PERMANENTLY REPAIR LEAKING SIGHT GLASS ON SLOP TANKS AND PROVIDED CLASS REPORT.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 22 July 2000
Resolved
MSD does not have an identification lable as required by 33CFR159.55(a).
Condition: Unknown
Due 23 July 2000
Resolved 2 October 2004
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 22 July 2000
Resolved
There is no high level alarm for the IGS' scrubber. SOLAS 74 amended II- 2/62.19.1.2.
Condition: Unknown
Due 23 July 2000
Resolved 2 October 2004
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 22 July 2000
Resolved
the lamp for the IGG's scrubber pump not working in the control panel. SOLAS 74 amended II-2/62.19.2.
Condition: Unknown
Due 23 July 2000
Resolved 2 October 2004
Engineering › Diesel Engine (auxiliary) › Valve
Issued 22 July 2000
Resolved
There is a leaking fuel oil supply valve for the emergency generator. SOLAS74 amended I/11.
Condition: Unknown
Due 23 July 2000
Resolved 2 October 2004
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 22 July 2000
Resolved
Oil transfer procedures not complete. 33CFR155.750(a)(1) through (a)(11).
Condition: Unknown
Due 23 July 2000
Resolved 2 October 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 July 2000
Resolved
Fire doors in the stair tower do not shut completly. SOLAS 74 amended II- 2/46.1.
Condition: Unknown
Due 23 July 2000
Resolved 2 October 2004
Accommodation/Occupational Safety › Messroom › Location
Issued 22 July 2000
Resolved
MARPOL placard was not posted in the galley. 33CFR151.59(a)(2)(ii)(b).
Condition: Unknown
Due 23 July 2000
Resolved 2 October 2004
Lifesaving › Launching Appliances › Falls
Issued 22 July 2000
Resolved
Brake on the starboard lifeboat davit needs adjustment. SOLAS 74 amended III/48.2.9.
Condition: Unknown
Due 23 July 2000
Resolved 2 October 2004
Accommodation/Occupational Safety
Issued 28 January 1997
Resolved
MARINE SANITATION DEVICE MISSING USCG APPROVAL PLATE.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Electrical
Issued 28 January 1997
Resolved
MISSING NON-CONDUCTIVE MATTING IN FRONT OF ELECTRICAL CABINETS.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Deck/Cargo
Issued 6 February 1996
Resolved
VESSEL DID NOT HAVE GAS FREE CERTIFICATION BY MARINE CHEMIST TO ENTER PUMP ROOM. MUST PROVIDE GAS FREE CERTIFICATE FOR PUMP ROOM AND MAKE AVAILABLE FRO CG MARINE INSPECTOR BY NEXT U.S. PORT.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Accommodation/Occupational Safety
Issued 6 February 1996
Resolved
VESSEL DID NOT HAVE A CG APPROVAL NUMBER ON ITS TYPE II MSD. MUST PROVIDE _x001C_MANUFACTURERS PLACARD WITH CG CERTIFICATION NO.
Condition: Unknown
Due 6 March 1996
Resolved 12 February 1996
Navigation
Issued 6 February 1996
Resolved
PROVE PROPER OPERATION OF THE MAGNETIC COMPASS.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Navigation
Issued 6 February 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Lifesaving
Issued 6 February 1996
Resolved
VESSEL DID NOT HAVE WEAK LINKS FOR FLOAT FREE INSTALLATION OF LIFERAFTS. _x001C_ MUST PROVIDE PRIOR TO NEXT U.S. PORT. AS PER SOLAS 74 AMMENDED CHAPTER 3_x001C_ REGULATION 38.6.2
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996