MAURY USCG vessel records Sign in
← All vessels

MSC JAPAN

MSC JAPAN is a 1996 freight ship. The Coast Guard has recorded 42 inspections since 1996, most recently in August 2023, along with 13 deficiencies and 8 operational controls.

Records from 1996 to 2023. Most recent: operational control imposed, 28 August 2023.

Built
1996
Last inspected
28 August 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9110975 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
435816
Flag
PANAMA
—
Maury page id
psix-435816

Inspections, by type

…with no type recorded25
Years with a record 14 calendar years (1996–2023)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it37518 - Convention (Subpart B), Gross Ton
22460 - Convention (Subpart B), Net Ton
63430 - Displacement, Metric Ton
49272 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HARRIET MORAN Towing Vessel · MISLE 154934 · 28 January 2008 · activity 3138247CAPE ROMAIN Towing Vessel · MISLE 175672 · 28 January 2008 · activity 3138247CHELSEA Freight Ship · MISLE 48264 · 29 January 1999 · activity 46512

Inspection history · 42

28 August 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7776528
21 August 2023 PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7773085
29 October 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7585927
4 August 2022 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7519758
23 April 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7437690
20 April 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7435572
3 March 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7403415
26 December 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7371261
27 January 2021 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7130576
16 August 2020 Deficiency Check · PSC B · ISM Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7034299
28 June 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6189406
28 June 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6189469
19 January 2017 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6073410
30 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6063925
22 December 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6061345
4 June 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5897022
30 April 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5866114
7 October 2015 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5737555
22 August 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3305509
17 August 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3300631
26 June 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3248581
9 May 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3202593
25 February 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3156077
28 January 2008 PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3138079
28 January 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3138247
24 December 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3120354
22 December 2007 NPV Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3119777
7 September 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3051574
2 September 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3045537
4 June 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2950922
12 August 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 281040
25 June 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 638361
10 June 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 278763
4 December 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 435404
31 July 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 431277
29 January 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 46512
20 July 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 418182
24 September 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 408260
23 January 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 399832
3 December 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 192071
3 December 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754270
2 February 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 387553

Deficiency record · 13

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 21 August 2023 Resolved
During the abandon ship drill, the port side lifeboat remote braking cable snapped, rendering the lifeboat unusable in an emergency condition.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 August 2023
Resolution: Vessel crew replaced the affected braking cable, USCG examiners verified repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 August 2020 Resolved
The Company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. In meeting these requirements, the Company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: the crew failed to fully implement the requirements of the ISM code through their SMS procedures. These identified deficiencies are evidence that the ship and/or company are not meeting the SMS requirements. Recommend external audit. During the exam, PSCO requested engineering crew to conduct a test of the engine room bilge alarm system. Vessel’s electrician was tasked by the Chief Engineer to conduct the requested tests. In the presence of the PSCO, the electrician removed the bilge containment gratings in vicinity of the high and low sea chests to access the bilge alarms. The bilge water in each location was found to be so high that it almost reached the bilge deck plate (i.e. at such at a high level that the bilge alarms should have already been activated). PSCO asked the electrician why the audible and visual components of the bilge alarm system weren’t engaging, the electrician stated that he had disconnected the alarms without providing further explanation. The PSCO determined that the consistent ingress of water into this area was attributed to excessive leaking from the general service pump and sea water intake piping. The inoperability of the bilge alarms, deterioration of the general service pump and lack of watertight integrity within the piping system demonstrates neglect of the crew to address these issues in a timely and proper manner. The SMS required weekly and monthly inspections of the E/R to include operation of the bilge alarms. None of the weekly logs indicated any report of the nonconformity of the bilge alarm nor corrective action taken. Additionally, the operational readiness and effectiveness of the CO2 fire suppression system was found to be in non-compliance with the system’s intended design and installation. Two CO2 dispersion nozzles within the overhead of of the main diesel engine was missing (i.e. not installed).Maintenance of the CO2 system was conducted by a third party contractor in May of 2020; therefore the absence of these dispersion nozzles at the time of examination is inexplicable. The engineering department completed weekly and monthly inspection reports (i.e. logs), where the existing non-conformities on the CO2 system were not recorded, reported, or corrected as required by the SMS. This is clear evidence that the ship’s crew was not performing adequate required inspections and/or not submitting notifications to the vessel's classification society.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 17 August 2020
Resolved 18 August 2020
Resolution: External Audit of the Shipboard Safety Management System (SMS) completed by DNV-GL on August 18, 2020.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 August 2020 Resolved
The piping for the distribution of fire-extinguishing medium shall be arranged and discharge nozzles so positioned that a uniform distribution of medium is obtained. PSCOs discovered 02 fixed carbon dioxide dispersion nozzles missing from piping outside of engine control room. 74SOLAS(97)II-2/5.1.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2020
Resolved 17 August 2020
Resolution: CO2 dispersion nozzles installed and approved by Classification Society Surveyor and MSC Superintendent.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 August 2020 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devises approved by the Administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided for an additional three starts within 30 min. PSCOs witnessed crew try to start the emergency generator via hydraulic start for 30 minutes with no start achieved. 74SOLAS(04)II-1/44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2020
Resolved 17 August 2020
Resolution: PSCO witnessed proper operation of the vessel's EDG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 August 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs witnessed 04 soft patches on piping throughout the engine room. 01 on sea water piping along fwd bilge near GS pump, 03 in the overhead outside of the engine control room. SOLAS 74 (88 Protocol) I/11
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 August 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed substantial sea water ingress from one of the vessel’s general service pumps of approximately 1 gallon an hour, lack of machinery guard over impeller shaft, and wasted and missing mounting hardware. 74solas(04)II-1/26.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 December 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 August 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person onboard. Bilge alarm system is inoperable (disconnected) and unable to produce audible or visual alarm for water ingress. SOLAS 74 (88 Protocol) I/11
Action required: 30 - Ship detained
Due 16 August 2020
Resolved 17 August 2020
Resolution: Tested all engine room bilge alarms and found all 06 engine room bilge alarms to be operational.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 29 January 2008 Resolved
RO to attest to proper implementation of SMS in regards to the emergency anchoring procedures.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 February 2008
Resolution: Received class report clearing above issued def.
Stability › Watertight Integrity › General
Issued 28 January 2008 Resolved
Due to vessel running aground, vessel must provide dive survey to Baltimore OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: Provided dive survey, all sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 28 January 2008 Resolved
Class to attest to proper operation of vessel's failed #2 generator fuel booster pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2008
Resolution: Received class report clearing above issued def.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 28 January 2008 Resolved
Class to attest to proper operation of failed relay switch of #2 fuel booster pump.
Due 28 February 2008
Resolved 1 February 2008
Resolution: Received class report clearing above issued def.
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 January 2008 Resolved
Emergency generator was unable to sustain electrical load after service generators failed. Class to attest to proper operation.
Due 28 February 2008
Resolved 1 February 2008
Resolution: Received class report clearing above issued def.
Navigation › Piloting/Steering › Gyro Compass
Issued 24 December 2007 Resolved
Master requested a Letter of Deviation to enter the Port of New York with an inoperable gyrocompass. Letter of Deviation was issued to the vessel. Repairs to the gyrocompass must be completed prior to departure from the Port of New York.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2007
Resolved 26 December 2007
Resolution: Received technicians report #Y/599251 from Mackay Marine stating the problem with the Gyrocompass was identified as a bad sensor PCB. Sensor PCB was replaced and the Gyrocompass was reported to be working in satisfactory condition.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.