WINE THERAPY

WINE THERAPY is a 1958 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1985, most recently in August 2025, along with 145 deficiencies, 4 operational controls and 4 casualty investigations between 2012 and 2023.

Records from 1985 to 2025. Most recent: inspection, 12 August 2025.

Built
1958
Last inspected
12 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI3849
Flag
UNITED STATES
367692560
Maury page id
psix-43584

Inspections, by type

…with no type recorded10
Years with a record 36 calendar years (1985–2025)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 15.7 ft × 4.5 ft
Registered tonnagegross 19 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFRIES BOATS INC · VENICE, CA, UNITED STATES · built 1958
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI3849MMSI 367692560 · active · compulsorily equipped · granted 24 September 2025, expires 18 September 2035
WDD2894MMSI 367121240 · expired · compulsorily equipped · granted 13 June 2006, cancelled 13 August 2016
WDA8687MMSI 366856990 · expired · compulsorily equipped · granted 11 June 2002, cancelled 11 August 2012 · licensed under a name not among this hull’s recorded names (not shown)
WCZ5059MMSI not assigned · expired · compulsorily equipped · granted 20 September 1999, cancelled 21 November 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

12 August 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8207389
9 December 2024 Deficiency Check · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8043980
6 August 2024 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7973719
23 August 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7774119
31 March 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7660888
31 March 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7662715
28 November 2022 Internal Structural Exam · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7597843
16 August 2022 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7534762
15 June 2021 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7212432
12 January 2021 Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7122436
8 June 2020 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6968149
2 August 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6776147
9 July 2019 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6743931
4 December 2018 Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6592935
4 June 2018 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6433810
28 August 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6254141
26 October 2016 Internal Structural Exam · Drydock Exam · In-Service Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6030341
25 May 2016 COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5881187
12 March 2016 Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5833002
12 March 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5834379
15 October 2015 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5743776
1 August 2015 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5205285
3 June 2014 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4880205
5 March 2009 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3421083
21 October 2008 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3351656
6 October 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3339567
26 August 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3297256
20 May 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3212216
13 September 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3060653
13 June 2007 Plan Review "T" Boat · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2958700
20 June 2006 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2664584
23 January 2006 Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2571962
11 August 2005 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2442974
16 May 2005 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2359736
1 April 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2359479
29 July 2004 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2135206
26 July 2004 In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2146136
23 July 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2147184
18 February 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1999656
2 October 2003 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1920170
2 October 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1923842
25 August 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1884099
25 August 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1887114
23 July 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1842432
28 May 2002 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1620215
15 May 2000 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 818617
9 February 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1046319
8 April 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1124557
1 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1423156
1 April 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1460316
30 July 1998 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1129345
16 July 1998 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 795060
21 March 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413143
19 March 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357508
7 February 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374501
22 November 1995 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 879779
13 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 861987
15 November 1994 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 864983
21 October 1994 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 860961
18 August 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 870442
14 July 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1412669
4 February 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828681
28 August 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 953877
18 May 1992 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1256733
5 February 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 953374
19 February 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 912262
5 February 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995615
17 October 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 934861
21 March 1990 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1212662
8 February 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 910346
6 March 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 889086
6 February 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1342086
28 April 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1343436
30 March 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1300040
8 February 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1020340
18 September 1987 Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1321051
20 July 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329139
12 March 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1012641
10 February 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1010789
3 March 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1301475
11 February 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1301474
11 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1287953

Deficiency record · 145

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 August 2025 Resolved
Provision must be made be means of plugs, covers, etc., to prevent the admission of air into the space protected. Wire run obstructed functionality of closure device. 46CFR 181.20-35 "Old T"
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 27 August 2025
Resolution: Operator emailed photo of engine room fire damper fitted into place. Photo uploaded to documents.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 August 2025 Resolved
The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter: Each pendant must be made up in a hank, and the hank secured by not more than two turns of light twine. Pendants were not made up into hanks. 46 CFR 180.175(f)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 27 August 2025
Resolution: Operator emailed photos of pendants made up into hanks. Photos uploaded to documents.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 12 August 2025 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] shackle securing anchor rode to vessel was wasted. 46 CFR 184.300
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 27 August 2025
Resolution: Operator emailed photo of new shackle installed. Photo uploaded to documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 August 2024 Resolved
The fixed power bilge pump shall be self-priming and may be driven off the main engine or other source of power. MI observed a deteriorated belt for the engine driven bilge pump, operator replaced on the spot. 46 CFR 182.25-10 Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2024
Resolution: Vessel operator replaced bilge pump belt, while MIs were still on board.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 August 2024 Resolved
Each survival craft must be: secured to the vessel by a painter with a float-free link permanently attached to the vessel. Life floats float-free link was not connected, install to satisfaction of MI. 46 CFR 180.130 (a)(1)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2024
Resolution: Submitted satisfactory photo of new connection.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 August 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life floats had damage exposing the inner portion of the rafts, repair to MI satisfaction. 46 CFR 185.175(a)(4)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2024
Resolved 8 August 2024
Resolution: Submitted documentation of rapairs, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2024 Resolved
Filling and sounding pipes shall be arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. Sounding pipes may be omitted where sounding can be accomplished through the fill pipe or where marine type fuel gages are installed. Where sounding pipes are used, their openings shall be at least as high as the opening of the fill pipe and they shall be kept closed at all times except during sounding Vessel's filling and sounding piping was allowing overflow into the space. Replace the hoses to the satisfaction of the MI. 46 CFR 182.20-30(b) Old T
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 8 August 2024
Resolution: Hose was properly replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Vessels guard on the aft belt of the engine was found broken and not properly covering the exposed belt. Repair the guard to the satisfaction of the MI. 46 CFR 117.35-15 OLD T
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 29 August 2024
Resolution: Received photo evidence of securing the support guard. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2024 Resolved
At least one ring life buoy must be fitted with a lifeline... Each lifeline on a ring must: be buoyant. MI observed forward life line was not of buoyant type. Replace line the line to satisfaction of the MI. 46 CFR 180.70 (c)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 8 August 2024
Resolution: Replaced line, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 August 2024 Resolved
Each bouyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. The material must be in strips at least 55 mm (2 in.) wide extending from top to bottom over the side or end and continuing over the top and bottom surfaces of the apparatus. For peripheral body apparatus, each strip must extend completely over the top and bottom surface of the body. For box type apparatus, the strip must extend at least 300 mm (12 in.) inboard from the edge over the top and bottom surface. Each strip must be positioned near the center of the side or end, but so that it is not obscured by any strap. Multiple sections of tape were found not properly installed as required. Replace the tape to the satisfaction of the MI. 46 CFR 160.010-4(p)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 8 August 2024
Resolution: Reapplied tape all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 August 2024 Resolved
Each first-aid kit must meet the requirements in ISO 18813:2006(E) paragraph 4.12 (incorporated by reference, see § 199.05).(i) A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12, except that it does not contain the burn preparations. It must be clearly marked on the first-aid kit that it does not include the burn preparations.(ii) The active ingredients in medicinal products must conform to over-the-counter (OTC) drug regulations set out in 21 CFR part 330. Vessel had several items in their med kit, bring med kits up to ISO 18813:2006 (E) standard. 46 CFR 199.175(b)(10) 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 29 August 2024
Resolution: Vessel removed all expired meds and are now in compliance.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 August 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; Tide tables. Vessel charts and tide tables were outdated, update to MI satisfaction. 46 CFR 184.420 (a) (1)/(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 29 August 2024
Resolution: Vessel submitted photo of new chart and tide table. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 August 2024 Resolved
Each flare carried to meet this section must be stowed in one of the following: A portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station. Flare box paint appeared faded, repaint to MI satisfaction. 46 CFR 180.68 (e)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 8 August 2024
Resolution: Repainted all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks; A crack was discovered in the port side sanded area within void space 4. Diagnose extent of the damage of the crack and repair to the satisfaction of the Marine Inspector. 46 CFR 176.405(a)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 9 December 2024
Resolution: MI confirmed no crack found in the port side of space 4. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2024 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Vessel has a removable section of its bulkhead that has been found removed and allows vapors to escape to other areas of the vessel. Make the removable section permanent to the satisfaction of the Marine Inspector. 46CFR177.405(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 9 December 2024
Resolution: MI confirmed vapor barriers sufficient for vessel design/construction. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Vessel weather deck surrounding the hatch into the lazarette was found to be delaminating allowing water into the space. Submit temporary repair proposal to the satisfaction of the MI with a permanent repair to be conducted at the vessels next drydock. 46 CFR 176.802(a)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 27 January 2025
Resolution: Watertight deck hatch installed to satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 August 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel did not have the fire buckets on board of the vessel during the inspection. Vessel must obtain the required fire buckets of this regulation to the satisfaction of the attending Marine Inspector. 46CFR181.610
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2023
Resolution: Vessel Represenative was able to produce the amount of Fire Buckets required.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 23 August 2023 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2), except that a VHF radiotelephone installation without DSC capability is permitted until one year after the Coast Guard notifies the Commission that shore-based sea area A1 coverage is established. Vessels in this category must not operate more than 20 nautical miles from land. Vessel's VHF is not properly programmed with DSC which includes the vessel's MMSI and GPS coordinates. Vessel must upload and integrate all three of these systems into their radios to the satisfaction to the attending Marine Inspector. 46CFR184.502 47CFR80.905(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 8 September 2023
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 23 August 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel's Radiotelephone certificate showed incorrect information and radios tested did not meet the requirements outline in this part. The vessel radio telephony certificate is deemed invalid, vessel must obtain a new radio telephony certificate. 46CFR184.502 47CFR80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 21 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 August 2023 Resolved
Each floating water light installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the water light to be quickly disconnected from the ring life buoy. Vessel's water light was tied onto the life buoy. Vessel must install the water light to the satisfaction the the attending Marine Inspector. 46CFR180.70(d)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 8 September 2023
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 August 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel has multiple publications listed that were out of date. Vessel must obtain up to date publications to the satisfaction of the Marine Inspector. 46CFR1184.420(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 15 September 2023
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 March 2023 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Vessel reported damage to hull after allision with dock. Make necessary repairs to the hull and submit all repair proposals to the satisfaction of the Coast Guard marine inspector. 46 CFR 177.01-05(a) “OLD T”
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 April 2023
Resolution: Vessel made satisfactory repairs and conducted successful sea trial.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 February 2023 Resolved
Watertight integrity above the margin line in a vessel less than 100 gross tons.(a) Each hatch exposed to the weather must be watertight, except that the following hatches may be weather tight: (1) Each hatch on a watertight trunk that extends at least 12 inches (30.5 cm) above the weather deck. (2) Each hatch in a cabin top. (3) Each hatch on a vessel that operates only on protected waters. (b) Each hatch cover must- (1) Have securing devices; and be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss.(c) Each hatch that provides access to crew or passenger accommodations must be operable from either side. Access cover leading into the space aft of collision bulkhead is not watertight. 46CFR121.124 (OLD T, OLD S)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2023
Resolved 24 February 2023
Resolution: Replaced the hatch with approved type. OP TESTED SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 August 2022 Resolved
The breaking strength of each (float-free) link must be between: (1)450 N (100 lbs) and 600 N (134 lbs) for links intended for life floats and buoyant apparatus of 10 persons and less capacity.(2) 900 N (200 lbs) and 1200 N (268 lbs) for links intended for life floats and buoyant apparatus of 11 to 20 persons capacity. Vessel's weak link leading to 6 person life float is not compatible with current installation. In addition, 22 person life float's weak link is missing required identifying information.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 1 September 2022
Resolution: Received satisfactory photo.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 June 2021 Resolved
"All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections." 46 CFR 183.01-15(a). Bundle electrical installations in bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 17 June 2021
Resolution: Provided photos of satisfactory bundling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 June 2020 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. The vessel's main propulsion engine exhaust lagging is torn. Repair the exhaust lagging to the satisfaction of the Marine Inspector. 46 CFR 177.10-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2020
Resolved 13 July 2020
Resolution: Replaced
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 June 2020 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. There are multiple bulkhead penetrations in the forward bulkhead of the Engine Room that are not vapor tight. Seal the bulkhead penetrations to restore the vapor tight boundaries of the Engine Room compartment. 46 CFR 177.10-5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2020
Resolved 13 July 2020
Resolution: Sealed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 June 2020 Resolved
At each inspection, the marine inspector shall examine all weather tight closures above the weather deck. The gasket for the watertight hatch on the No. 2 compartment is damaged. Repair the gasket to restore the watertight integrity of the main deck. 46 CFR 176.25-5 (5)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2020
Resolved 13 July 2020
Resolution: Repaired
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 4 December 2018 Resolved
Crop and renew rotten port underdeck beam and deck on forward most main deck hatch at next credit dry dock in 2021.
Action required: 705 - Other - as specified
Due 31 January 2021
Resolved 12 January 2021
Resolution: Beam was satisfactorily cropped and renewed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 4 June 2018 Resolved
Replace the fuel line support (currently zip lines) with metallic/fire resistant material.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2018
Resolution: Metal support has been installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 June 2018 Resolved
Replace the wing nut connections on each battery with standard nut connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2018
Resolution: Wing nuts were removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 June 2018 Resolved
Replace fwd battery broken connection (port fwd, for the anchor windlass).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2018
Resolution: Connection was replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 4 June 2018 Resolved
Replace deteriorated life ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2018
Resolution: New Ring was installed.
Engineering › Bilge Water Management System › Not Operational
Issued 4 June 2018 Resolved
Install visual bilge alarms on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 July 2018
Resolution: Photo documentation provided of visual alarm at the operating station.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 June 2018 Resolved
Install machinery guard to cover the alternator belts on the main engine.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2018
Resolution: Machinery guard has been installed.
Construction/Loadline › Hull › Bracket
Issued 4 June 2018 Resolved
Identified crack in the vertical corner structure of the laz, port aft side - 3 planks of wood each approx 1/2" comprise the corner post, only the outer post appears to be cracked and also has an approx 1" spot of rot in the same vicinity. Prep the area for inspection prior to the upcoming drydock in December and be prepared for probable replacement of structural member. Ref: NVIC 7-95
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 15 June 2018
Resolution: Crack will be reviewed for potential replacement during the next drydock.
Lifesaving › Hand Flares › Expired
Issued 28 August 2017 Resolved
3 hand flares and 3 smoke signals onboard were expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 28 August 2017
Resolution: New flares/ smoke signals were purchased prior to the end of exam.
Engineering › Bilge Water Management System › Valve
Issued 26 October 2016 Resolved
Provide screw down valve for the forpeake bilge suction that is operable from the weather deck IAW 46 CFR 182.510(d)
Due 6 June 2017
Resolved 28 August 2017
Resolution: witnessed remote operation of the bilge suction valve.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 May 2016 Resolved
Vessel's anchor light inoperable. Make proper repairs to the anchor light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 26 May 2016
Lifesaving › Lifefloat › Serviceable
Issued 25 May 2016 Resolved
Renew primary lifesaving equipment for a minimum of 25 persons, 50%. If changing equipment from lifefloats, provide equipment information and arrangement for approval.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 13 July 2016
Lifesaving › Lifefloat › Float-free Link
Issued 25 May 2016 Resolved
Installed weak link on lifefloats is for 11-20 persons. Replace with proper weak link for 28 person capacity.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 15 June 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 May 2016 Resolved
All waterlight batteries are expired, renew with proper new batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 26 May 2016
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 May 2016 Resolved
Provide proof of obtaining 1 adult PFD to meet COI requirements.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 May 2016
Documentation › Logs/Records › Drug Test Records
Issued 25 May 2016 Resolved
Provide current list of crewmembers enrolled in drug and alcohol program
Condition: Invalid
Due 1 June 2016
Resolved 27 May 2016
Lifesaving › Lifebuoys › Serviceable
Issued 25 May 2016 Resolved
Installed lifering damaged from exposure, renew with new.
Condition: Improper/Lack of Maintenance
Due 25 June 2016
Resolved 26 May 2016
Navigation › Piloting/Steering › Marine Charts
Issued 25 May 2016 Resolved
Provide current and corrected charts and publications for area of transit.
Condition: Improper/Lack of Maintenance
Due 6 June 2016
Resolved 15 June 2016
Engineering › Bilge Water Management System › Hose
Issued 25 May 2016 Resolved
Bilge suction in the forepeak and #4 void inoperable. Make proper repairs and prove proper operation.
Condition: Improper/Lack of Maintenance
Due 30 May 2016
Resolved 27 May 2016
Stability › Weathertight Integrity › General
Issued 25 May 2016 Resolved
Renew the attachements for the identified deck hatches.
Condition: Improper/Lack of Maintenance
Due 6 June 2016
Resolved 15 June 2016
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 12 March 2016 Resolved
Vessel had a loss of propulsion with passengers onboard. Identify and correct cause of the engine failure. Prove proper operation of the MDE to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2016
Resolution: Successful dock trials completed.
Lifesaving › Lifefloat › Markings
Issued 31 August 2015 Resolved
Renew each lifefloat's retro-reflective tape and apply new coat of paint, including vessel name, to the satisfaction of attending CG inspector. 46CFR180.210(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 4 October 2015
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 31 August 2015 Resolved
Obtain and post valid Federal Communications Commission (FCC) and Bridge-to-Bridge Certificate and Station License. 47CFR80.1001 & 47CFR80.13
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 4 October 2015
Operations/Management › Passenger Operations › Safety Orientation
Issued 31 August 2015 Resolved
Implement method of recording passenger count that is available to CG and rescue personnel during each voyage. 46CFR185.504
Action required: 705 - Other - as specified
Due 14 September 2015
Resolved 4 October 2015
Engineering › Fuel Oil Service System › Valve
Issued 31 August 2015 Resolved
Install a fuel shut off valve on the engine end of the supply line to stop flow when servicing accessories. Install to satisfaction of OCMI.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 4 October 2015
Fire Fighting › Fire Bucket › Quantity
Issued 3 June 2014 Resolved
Provide 03 fire buckets on board.
Due 3 July 2014
Resolved 27 June 2014
Resolution: Provided
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 June 2014 Resolved
Replace hose clamps to secure hose to sewage holding tank.
Due 3 July 2014
Resolved 27 June 2014
Resolution: Provided
Lifesaving › Lifefloat › Float-free Link
Issued 3 June 2014 Resolved
Provide new weak link and properly install.
Condition: Improper Installation
Due 17 June 2014
Resolved 27 June 2014
Resolution: Provided
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 June 2014 Resolved
Provide current notice to mariners, light list, and coast pilot.
Due 3 July 2014
Resolved 27 June 2014
Resolution: Provided
Construction/Loadline › Hull › Stringer
Issued 5 March 2009 Resolved
Submit a repair proposal to address wood corrosion (rot) in the forepeak compt. Take all areas to good wood, to include lower aft stbd frame/backing at collision bkhd/keel, lower aft port frame/backing outboard of keel, and starboard wide laminated longitudinal (insert) just above the keel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2009
Construction/Loadline › Hull › Transverse Frame
Issued 5 March 2009 Resolved
Provide a repair proposal for collision bulkhead in the bow thruster hold, at forward starboard inboard keel area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2009
Resolution: determined to be mitigated by replacement of frame/backing piece in forepeak compartment on opposite side of this area.
Engineering › Bilge Water Management System › Pump
Issued 5 March 2009 Resolved
Re-adjust bilge pump float switch in aft engine room, and engine room high-level bilge alarm float switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 March 2009 Resolved
Provide access to engine room bilges. Remove deck plates/floors to expose frames and longitudinals for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 March 2009 Resolved
Repair rotted deck at the forward starboard area of the lazarette hatch.
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 22 June 2010
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Company policy insufficient, as required by 46 CFR 16.401.
Due 21 November 2008
Resolved 20 November 2008
Resolution: Company''s drug and alcohol policy has been updated.
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR 16.240.
Due 21 November 2008
Resolved 20 November 2008
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 21 November 2008
Resolved 20 November 2008
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR 16.240.
Due 21 November 2008
Resolved 20 November 2008
Resolution: Post-casualty arrangements are set up through company''s consortium.
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 21 November 2008
Resolved 20 November 2008
Resolution: EAP program posted.
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 21 November 2008
Resolved 20 November 2008
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 21 November 2008
Resolved 20 November 2008
Resolution: Supervisor recieved 1 hr of EAP training.
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Substane Abuse Professional (SAP) name and contact information not posted as required by 46 CFR part 16.401.
Due 21 November 2008
Resolved 20 November 2008
Resolution: SAP contact information posted.
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company’s drug and alcohol policy in accordance with 46 CFR 16.401.
Due 21 November 2008
Resolved 20 November 2008
Resolution: Crewmembers are now recieving EAP training prior to assuming a safety sensative position.
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 21 November 2008
Resolved 20 November 2008
Documentation › Logs/Records › Drug Test Records
Issued 21 October 2008 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 21 November 2008
Resolved 20 November 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 September 2008 Resolved
Stencil vessels name on the life ring.
Due 9 September 2008
Resolved 9 September 2008
Resolution: Stenciled while on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 September 2008 Resolved
Remove wire nut from installed music radio next to the serving area.
Due 9 September 2008
Resolved 10 September 2008
Resolution: Re-visited vessel and wire nut was replaced with butt connector.
Personnel › Training › First Aid/CPR
Issued 9 September 2008 Resolved
Provide proof of CPR & first aid training.
Due 9 October 2008
Resolved 6 October 2008
Resolution: Class scheduled and paid for, for 22 Oct 08.
Engineering › Bilge Water Management System › Not Operational
Issued 20 June 2006 Resolved
Prove proper operation of engine room high level bilge alarm indicator light at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 22 June 2006
Lifesaving › Lifefloat › Float Free
Issued 20 June 2006 Resolved
Properly arrange lifefloats to meet stowage requirements of 46 CFR 180.137 to include arrangement of lifeline weak link, painter and waterlights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 22 June 2006
Engineering › Pressure Vessel › Relief Valve
Issued 20 June 2006 Resolved
Prove proper operation of pressure relief valve on air receiver.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 22 June 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 June 2006 Resolved
Replace expired items in First Aid kit to include eye wash, burn gel and aspirin.
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 June 2006 Resolved
Properly mark ring buoy with retro-reflective tape.
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 June 2006 Resolved
Properly mark 5 adult lifejackets with vessel's name and provide retro-reflective tape.
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Stability › Watertight Integrity › General
Issued 23 January 2006 Resolved
Make watertight all thru bulkhead penetrations to include bilge suction line and electric cable lines.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 4 April 2006
Engineering › Bilge Water Management System › Valve
Issued 23 January 2006 Resolved
Label bilge suction valve on deck in collision bulkhead space.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 4 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 23 January 2006 Resolved
Submit a repair proposal to renew as original damage to wood on starboard side in second hold from the bow.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 4 April 2006
Stability › Watertight Integrity › Coaming
Issued 23 January 2006 Resolved
Add coaming to vent pipe on second hold from the bow for watertight integrity.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 4 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 January 2006 Resolved
Replace twist-on type connectors in the space under pilothouse IAW 46CFR183.340(i)(2)
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 4 April 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 23 January 2006 Resolved
Secure cable in space under pilothouse every 24 inches
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 4 April 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 23 January 2006 Resolved
Dead end loose wire in space under pilothouse.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 4 April 2006
Construction/Loadline › Structures › Superstructure
Issued 23 January 2006 Resolved
Secure all wood block supports throughout the vessel under bilge piping.
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 9 February 2006
Construction/Loadline › Structures › Superstructure
Issued 23 January 2006 Resolved
Renew backing block in deteriorated wood on fire pump sea suction in way of engine room space.
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 9 February 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 23 January 2006 Resolved
Provide proper method of securing ventilation to engine room space.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 4 April 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 23 January 2006 Resolved
Renew propeller strut backing plate in way of compartment #7 as indicated by attending marine inspector.
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 9 February 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 23 January 2006 Resolved
Conduct underway sea trials for issuance of credit drydock.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 20 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 August 2005 Resolved
Procure or replace two life jackets with serviceable life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 20 June 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 May 2005 Resolved
Provide proof of enrollment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2005
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 29 July 2004 Resolved
Mounting bracket for pilot house Fire extinguisher not holding extinguisher properly.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 August 2004
Resolved 29 July 2004
Resolution: Hook was bent back into shape before inspector left vessel. Mount properly working.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 26 July 2004 Resolved
Replace expended Fire Boy cylinder with a serviced pre-charged cylinder.
Action required: 705 - Other - as specified
Due 27 July 2004
Resolved 26 July 2004
Engineering › Reduction Gearing/Clutches
Issued 2 October 2003 Resolved
Clutch plate would not allow gears out of reverse. Vessel delayed voyage until after repairs and USCG clearance. Clutch plate was in an unlubricated portion of the gear box and required routine maintenance that the operator was not aware of. 2692 to be submitted along with PMS adjustment. LEGACY COMPONENT DESC: Gear
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2003
Resolved 9 October 2003
Documentation › Certificates/Documents
Issued 23 July 2003 Resolved
Vessel is required ti have a Ships Safety Radio Certificate. Master advised that M/V CHEERS is restricted to 1000 feet from shore until receipt of certificate. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Due 24 November 2003
Resolved 11 February 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 July 2003 Resolved
Replace reflective tape on 40 of 53 identified adult lifejackets and all seven of the childrens lifejackets. IAW 46 CFR 185.604(h) LEGACY COMPONENT DESC: Retroreflective Material
Due 23 August 2003
Resolved 25 August 2003
Engineering › Bilge Water Management System
Issued 10 July 2003 Resolved
Re-route all bilge sensor wiring in all spaces into a channel or harness and permanently affix to bulkhead. IAW 46 CFR 183.340. LEGACY COMPONENT DESC: Bilge sensor wiring
Due 23 August 2003
Resolved 25 August 2003
Documentation
Issued 21 March 1997 Resolved
PROVIDE STABILITY LETTER
Condition: Unknown
Due 4 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 March 1997 Resolved
PROVIDE PFD PLACARD
Condition: Unknown
Due 4 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 21 March 1997 Resolved
PROVIDE EMERGENCY STEERING ROD
Condition: Unknown
Due 4 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 18 August 1994 Resolved
PROVIDE CURRENT F.C.C. RADIOTELEPHONY CERTIFICATE. VESSEL NOT TO OPERATE MORE THAN 1000 FEET FROM SHORE UNTIL PROVIDED.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Construction/Loadline
Issued 4 February 1993 Resolved
TREAT WET ROT AS MARKED IN THIRD VOID AFT OF BOW.
Condition: Unknown
Due 4 February 1993
Resolved 4 February 1993
Construction/Loadline
Issued 4 February 1993 Resolved
TREAT EXPOSED WOOD AS MARKED IN FOURTH VOID AFT OF THE BOW.
Condition: Unknown
Due 4 February 1993
Resolved 4 February 1993
Navigation
Issued 4 February 1993 Resolved
PROVIDE PROPER DEVIATION CARD FOR MAGNETIC STEERING COMPASS.
Condition: Unknown
Due 4 February 1993
Resolved 4 February 1993
Deck/Cargo
Issued 5 February 1991 Resolved
FREE-UP FROZEN VALVE ON REACH ROD TO BILGE LINE, FORWARD COMPARTMENT.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Navigation
Issued 5 February 1991 Resolved
PROVIDE COTTER PIN OR DOUBLE NUT FOR STEERING CONTROL ARM IN LAZARETTE.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Lifesaving
Issued 5 February 1991 Resolved
RENEW 3 SIGNAL FLARES (1 ORANGE, 2 RED).
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Lifesaving
Issued 5 February 1991 Resolved
PROVIDE ONE (1) ADDITIONAL ADULT TYPE PFD.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Construction/Loadline
Issued 5 February 1991 Resolved
CLEAN AND TREAT DRYROT BENEATH FORWARD CLEAT PORT SIDE.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Lifesaving
Issued 8 February 1990 Resolved
REPLACE THE RETRO-REFLECTIVE TAPE ON THE ADULT SIZE TYPE ONE YOKE STYLE PFDIAW 46 CFR 180.25-25.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Lifesaving
Issued 8 February 1990 Resolved
POST THE EMERGENCY CHECKOFF IN A SPACE ACCESSIBLE TO PASSENGERS AND CREW IAW 46 CFR 185.25-1.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Electrical
Issued 8 February 1990 Resolved
REPLACE THE WIRE NUT CONNECTORS WITH CRIMP/BUTT STYLE CONNECTORS.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Construction/Loadline
Issued 8 February 1990 Resolved
REPAIR THE FRACTURED SIDE SHELL PLYWOOD IN THE COMPARTMENT FORWARD OF THE ENGINE ROOM, PORT SIDE 12 INCHES ABOVE WATERLINE.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Lifesaving
Issued 8 February 1990 Resolved
PROVIDE 3 ADDITIONAL TYPE ONE ADULT SIZE PFD'S.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Engineering
Issued 8 February 1990 Resolved
INSTALL A FLAME SCREEN IN THE FUEL OIL TANK VENT LINE IAW 46 CFR 182.20-35
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Lifesaving
Issued 8 February 1990 Resolved
LABLE THE CHILD SIZE PFD LOCKER IAW 46 CFR 185.30-10.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Engineering
Issued 6 February 1989 Resolved
REPLACE RUSTED ELBOW JOINT ON PIPING FROM COOLING PUMP TO HEAT EXCHANGER ONDIESEL ENGINE.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Electrical
Issued 6 February 1989 Resolved
PROPERLY WIRE ENGINE ROOM BILGE PUMP WITH AUTHORIZED WIRING.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Lifesaving
Issued 6 February 1989 Resolved
PROVIDE 6 ADDITIONAL ADULT PFD'S; OPS LIMITED TO 89 PAX UNTIL PROVIDED.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Navigation
Issued 8 February 1988 Resolved
TEST EMERGENCY TILLER AT FULL FORWARD POWER. ADD AN EXTENSION IF IT DOES NOT EASILY MOVE THE RUDDER.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Documentation
Issued 8 February 1988 Resolved
MAKE OPERATOR'S LICENSE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Navigation
Issued 8 February 1988 Resolved
REPLACE FORWARD TIE ROD END IN STEERING COMPARTMENT AND REPLACE MISSING COTTER PIN AT AFT TIE ROD END.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Construction/Loadline
Issued 8 February 1988 Resolved
REPLACE ROTTED PLYWOOD IN MAIN DECK PORT AND STARBOARD OF FOREPEAK ACCESS, UNDER WHEELHOUSE AND OVER ENGINEROOM.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Construction/Loadline
Issued 8 February 1988 Resolved
CROP OUT AND REPAIR ROTTED INNER HULL PLANKING (PLYWOOD) STARBOARD AFT IN #2 COMPARTMENT AS MARKED. A DOUBLER (SIMILAR TO PORT SIDE) MAY BE USED TO JOIN THE NEW MATERIAL TO EXISTING.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Construction/Loadline
Issued 8 February 1988 Resolved
COMPLETE REPAIRS OF ROTTED AREAS IN DECKHOUSE AND WHEELHOUSE SIDES, INCLUDING THEIR FRAMING.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Construction/Loadline
Issued 8 February 1988 Resolved
RESECURE MAIN DECK SEAM TO LONGITUDINAL IN PORT SIDE OF ENGINEROOM.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Documentation
Issued 8 February 1988 Resolved
RENEW FCC LICENSE.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Engineering
Issued 8 February 1988 Resolved
SUBMIT PLANS ON NEW EXHAUST INSTALLATION INCLUDING SPECIFICATIONS OF NON-METALLIC HOSE MATERIAL.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Lifesaving
Issued 8 February 1988 Resolved
DO NOT OPERATE WITH MORE THAN 81 ADULTS (INCLUDING CREW) AND 10 CHILDREN ON BOARD UNTIL REPLACING 14 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Navigation
Issued 8 February 1988 Resolved
DO NOT OPERATE IN HOURS OF DARKNESS OR REDUCED VISIBILITY WITHOUT REPLACINGAND TESTING PORT AND STARBOARD RUNNING LIGHTS, AND PORT AND STARBOARD EMERGENCY ACCESS LIGHTS.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Lifesaving
Issued 8 February 1988 Resolved
REPLACE 20" RING BUOY WITH 24" APPROVED RING BUOY AND ATTACH LIGHT AND LINE.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Lifesaving
Issued 10 February 1987 Resolved
PROVIDE 5 ADULT PFD'S. VSL LIMITED TO 90 PASSENGERS UNTIL PROVIDED.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Engineering
Issued 10 February 1987 Resolved
REPLACE FUEL HOSES WITH COAST GUARD APPROVED TYPE.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Engineering
Issued 10 February 1987 Resolved
PROVIDE FLAME GUARD FOR RACOR FUEL FILTER.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Engineering
Issued 10 February 1987 Resolved
REPAIR REACH ROD FOR FOREPEAK BILGE SUCTION VALVE.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Construction/Loadline
Issued 10 February 1987 Resolved
PROVIDE SECURING DEVICES FOR WEATHER DECK HATCHES.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Navigation
Issued 10 February 1987 Resolved
PROVIDE ANCHOR LIGHT.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Engineering
Issued 10 February 1987 Resolved
PROVIDE FLAME SCREEN FOR FUEL TANK VENT.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Engineering
Issued 10 February 1987 Resolved
PROVE PROPER OPERATION OF AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Construction/Loadline
Issued 10 February 1987 Resolved
REPAIR BROKEN PILOT HOUSE WINDOW.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987

Casualty record · 4

12 October 2012Routine · role: Involved in a Marine Casualty · activity 4464403
12 March 2016Routine · role: Involved in a Marine Casualty · activity 5834379
2 August 2019Routine · role: Involved in a Marine Casualty · activity 6776147
31 March 2023Routine · role: Involved in a Marine Casualty · activity 7662715
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

NEPTUNE (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.