← All vessels
LUCKY TRADER
Freight Ship · Bulk Carrier class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named LUCKY TRADER
LUCKY TRADER is a 1996 freight ship. The Coast Guard has recorded 36 inspections since 1996, most recently in August 2014, along with 24 deficiencies and 3 operational controls.
Records from 1996 to 2014. Most recent: inspection, 24 August 2014.
- Built
- 1996
- Last inspected
- 24 August 2014
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9128075 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2GL8
435916
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-435916
Inspections, by type
…with no type recorded18
Years with a record
18 calendar years (1996–2014)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it23522 - Dead Weight, Ton
14746 - Convention (Subpart B), Gross Ton
7920 - Convention (Subpart B), Net Ton
14746 - Convention (Subpart B), Gross Ton
7920 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 36
24 August 2014
Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4958420
22 August 2014
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 4963076
21 August 2014
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4961419
15 May 2012
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4312098
16 February 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3943049
22 January 2010
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3668087
23 December 2009
PI Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3654468
23 December 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3701304
22 December 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3654348
22 December 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3654997
16 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3434494
4 October 2008
PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3333263
21 February 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3151533
2 January 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3123304
25 September 2007
MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3056683
17 February 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2873509
16 August 2006
Random ISPS/MTSA-No PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2750484
9 May 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2641523
21 February 2006
PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2589035
28 June 2005
STCW 95 Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · ILO-147 Exam · PII Safety Exam
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2406481
16 July 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2253093
15 July 2004
ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2127199
27 May 2004
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2072222
21 May 2004
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2078789
4 December 2003
MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1953674
19 November 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1706399
6 August 2001
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 292690
24 February 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 287405
23 July 2000
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 280169
14 January 2000
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 273269
29 May 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 429043
25 November 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 422750
28 April 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 415259
20 February 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 400502
18 June 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 392393
7 February 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 387603
Deficiency record · 24
Fire Fighting › Fire Main › Material
Issued 24 August 2014
Resolved
0725- Every ship shall be provided with firemains complying as applicable with the requirements of this regulation. The port state control officer discovered the firemaindeteriorated to the point that a severe leak was observed during hte testing of the fire pump and water spraying from the fire main piping next to the cargo hold four after the test was finished. 74 SOLAS (97 CONS) II-2/4.1
Fire Fighting › Fire Pumps › Pumpshaft
Issued 24 August 2014
Resolved
0740- Condition of ship and equipment shall be maintained to conform with the provisions of the present conventions. PSCO discovered a rubber hose attached to the potable water valve supplying cooling water to the shaft on the fire/general service pump for cooling to prevent the shaft from seizing and having an inoperable fire pump. 74 SOLAS (09 CONS) I/11
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 24 August 2014
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 24 August 2014
Resolved
0940 - Condition of the ship and equipment shall be maintained to conform with the provisions of the present conventions to ensure that the ship in all respects will remain fit to proceed to sea without dangering the ship or persons on board. PSCO discovered a plastic hose attached to the weather deck sewage into the number four starboard ballast tank. 74 SOLAS 97 cond) I/11.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 24 August 2014
Resolved
2560 - Significant evidence was discovered during an expanded exam revealing hte company/vessel failed to implement all applicable requirements of the safety management system (SMS) by not verifying appropriate corrective action was taken and reporting deficiencies. Recommend an external audit of the vessel's SMS. ISM CODE REG 5, PART A REG 1.4, REG 2.2, REG 3, REG 5, REG 9, REG 10.
Lifesaving › Lifeboat › Canopy
Issued 16 February 2011
Resolved
0610: Freefall lifeboat has approx. 04 patches on the canopy. Patches were inspected by class back in 2009; verification from class need regarding current integrity of patches. 70a/b
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 16 February 2011
Resolved
0650: Both port and starboard lifebuoys are not capable of quick release due to separate release points for the lifebuoy and smoke/light. Class to verify the stowage of bridge wing lifebuoys. 70 a/b
Lifesaving › Rocket Parachute Flares › General
Issued 16 February 2011
Resolved
0640: Parachute flares shall be stowed in a water resistant casing. Starboard side bridge wing stowage for flares were being kept in an old first aid box covered with tape and not water resistant. 70 a/b
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 16 February 2011
Resolved
0720: Fireman's outfit shall protect the skin from fire, burns, and scolding by steam Vessel's fireman's outfit is worn and material is peeling off. In addition, vessel must have proper firefighting equipment onboard and does not have an adequate lifeline. 70 a/b
Lifesaving › Immersion Suits › General
Issued 16 February 2011
Resolved
0663: Immersion suits shall be of adequate size. Several immersion suits were too small for crew members. 70 a/b
Fire Fighting › Structural - A Class Divisions › Doors
Issued 16 February 2011
Resolved
0750: Vessel "A" class boundaries shall be constructed as to be capable of preventing the passage of smoke and flame. Several "A" class doors, including those surrounding the galley and leading to the bridge would not close properly. 70 a/b
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 February 2011
Resolved
0371: Vessel is required to have a [name withheld] stretcher onboard and in accordance with the World Health Organization standards. Stretcher onboard is rotten and needs to be replaced. 70 a/b ISM9/10
Engineering › Steering Gear System › Pump
Issued 16 February 2011
Resolved
0936: Steering gear L.O. reservoir tank shall have 225L to supply on pump. Tank currently has only 180 L. 70 a/b
Operations/Management › Ballast Water Managment › Sediments
Issued 16 February 2011
Resolved
0199: Vessel must keep proper written records of ballast operations IAW 33 CFR 151.2045. The ship was using an improper log form and the log book soundings did not match the report form In addition, they had no sediment log for the last dry dock as required in their plan. 70 a/b
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 16 February 2011
Resolved
2120: Incineration entry in logbook shall include start and stop time of incineration. Logbook is not recording the start and stop times. In addition, the vessel is using their auxiliary boiler to burn paper, oily rags, welding rods, metal, etc. and have not been approved to use their boiler for these purposes. 70 a/b
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 22 December 2009
Resolved
0613 Lifeboats: Lifeboats should be stowed and secure in a ready position. Crew added shims and lashings to secure the lifeboat. Cracks were found in the port and starboard quarters and on top forward of the centerline. The shifting of the lifeboat may have caused structural damage to the cradle. The lashings and shims will inhibit the rapid deployment of the lifeboat. Cracks flood the boat.70
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 February 2008
Resolved
Received notification that the 10cm radar was not functioning properly.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 21 February 2006
Resolved
The Ballast Water Management Plan is incomplete. It is missing sampling points, crew training, and calculations of the flow though method and flush and fill method. The plan's sediment log and ballast water handling log are not being used.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 21 February 2006
Resolved
There are discrepancies between the Waste Management Plan and the procedures on board. Color coding of the plan is not being followed. The crew has established several collection points where mixed garbage is being segregated; this is not part of the plan. The vessel's plan incorporates an incinerator and comminutor. The vessel does not have an incinerator; the comminutor has been sealed.
Navigation › Collision/Grounding Avoidance
Issued 4 December 2003
Resolved
Install a permanently affixed label to the ARPA. 33 CFR 164.38(d) LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Fire Fighting › Firemans Outfit
Issued 4 December 2003
Resolved
Excessive deterioration in both firemans outfits. Renew fireman's outfits. SOLAS 74 amd II-2/17 LEGACY COMPONENT DESC: Protective Clothing
Lifesaving
Issued 14 January 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 7 February 1996
Resolved
CHANGE CORD AT PHONE STATION IN STEERING COMPARTMENT TO ALLOW IT TO REACH FAR SIDE OF EMERGENCY STEERING STATION.
Fire Fighting
Issued 7 February 1996
Resolved
CORRECT FIRE CONTROL PLAN TO REFLECT COLOR CODE AND SYMBOLOGY IAW SOLAS CHPTR 2-II REG. 20, MSC RESOLUTION A.654(16).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.