MAURY USCG vessel records Sign in
← All vessels

CHUBASCO II

CHUBASCO II is a 1958 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1985, most recently in April 2026, along with 134 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 29 April 2026.

Built
1958
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2019
Flag
UNITED STATES
366688460, 368154850
Maury page id
psix-43593

Inspections, by type

…with no type recorded7
Years with a record 39 calendar years (1985–2026)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.1 ft × 18.0 ft × 4.7 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICHARD A MATHENY · COSTA MESA, CA, UNITED STATES · built 1958
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 14 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD2019MMSI 366688460 · active · compulsorily equipped · granted 20 March 2026, expires 27 April 2036
WDL6867MMSI 368154850 · active · compulsorily equipped · granted 18 July 2020, expires 18 July 2030
WCT4636MMSI 366688460 · expired · compulsorily equipped · granted 19 July 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 82

29 April 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8358400
8 May 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8132076
17 April 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8113018
22 October 2024 In-Service Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023518
6 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7929510
28 June 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818931
2 May 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7679832
2 June 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7447235
24 June 2021 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7235113
7 April 2021 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169942
4 June 2020 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6971231
30 March 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6933326
11 June 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6710487
16 April 2019 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6724573
19 April 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6394928
25 April 2017 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6136286
18 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5880526
17 December 2015 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5783606
28 May 2014 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4872077
2 May 2012 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4300423
23 February 2011 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3951172
14 May 2009 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3474840
20 February 2009 Construction Oversight · Simplified Stability Test · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3388918
8 May 2008 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3189375
7 May 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3201094
6 May 2008 Spot Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3201075
12 June 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2947982
9 February 2007 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2856641
5 May 2006 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2626398
26 April 2005 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2332455
4 March 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2301027
13 April 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2026845
15 December 2003 Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1964559
3 December 2003 Internal Structural Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1954224
28 April 2003 Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1798616
22 May 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1619548
18 April 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1606172
21 December 2001 Simplified Stability Test
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1607662
5 November 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391713
23 May 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376812
24 April 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399365
15 February 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381855
15 October 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 788564
16 September 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1441567
4 May 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1360889
26 April 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 790923
28 May 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1418362
8 May 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381207
21 October 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1112923
25 April 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406097
8 October 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416380
24 April 1996 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407656
30 October 1995 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 878823
24 August 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 879348
17 August 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1184016
17 March 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 869114
17 March 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1191459
28 November 1994 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1174715
27 October 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1176719
26 April 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858009
1 February 1994 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858295
19 August 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156619
21 May 1993 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 838604
3 August 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1254714
27 May 1992 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962915
13 December 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262581
16 July 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1248529
8 May 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 921971
31 May 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917096
11 May 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 923978
1 May 1989 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203222
26 May 1988 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 888787
16 May 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1348213
1 October 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1316746
23 April 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1316384
11 February 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1321199
9 February 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1011447
18 December 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 998000
22 November 1985 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1301310
15 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978379
26 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 979109
15 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1280863

Deficiency record · 134

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2026 Resolved
Observed a non-rigid rescue ladder. Vessel is to have deployable rigid rescue ladder with an assist line, sufficient rung space/s, and the side of the hull for proper footing (capable of supporting at least 2 persons-370LBS). 46CFR175.118(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2026
Resolution: POC provided images of new rescue ladder. All SAT
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 29 April 2026 Resolved
Observed FCC Radio Authorization station permit expired. Vessel is renew permit and provide proof of new authorization station permit. 47CFR80
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2026
Resolution: POC provided images of new FCC documents. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 June 2024 Resolved
The storage container for the distress flares was found wasted and not water-tight. Provide flares with a water-tight container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 12 June 2024
Resolution: Vessel was provided with a water-tight container.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 June 2022 Resolved
POSTED COD was expired. VSL was able to provide proof of updated COD before MI departure.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 3 June 2022
Resolution: Corrected
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 June 2021 Resolved
Navigational charts not carried onboard. Add to onboard inventory / publications.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received Photo's satisfying requirements.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 June 2021 Resolved
Salon / Messdeck area Smoke detector missing from ceiling mount. Install and test operation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received video of installation and Satisfactory Op-test of smoke detector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 June 2021 Resolved
Portside main deck remote fuel valve shut-off cabling failed during actuation. Repair / replace cable & optest
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2021
Resolved 24 June 2021
Resolution: Received video of cable replacement & operational test; All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021 Resolved
Electrical extension cord being used for galley microwave equipment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received photo of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021 Resolved
Electrical light fixture at operation station missing cable penetration. Provide cable cap / plug.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received photo of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2019 Resolved
Replace broken fuel oil shut-off valve on the stbd fuel tank.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2019
Resolution: Valve was replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 11 June 2019 Resolved
Make collision bulkhead water-tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Collision bulkhead was resealed and made water-tight.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2019 Resolved
Provide generator fuel hoses with double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Hoses were provided with double clamps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2019 Resolved
Provide port bait pump with electrical junction box for cable connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Junction box was installed and connections were enclosed within.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 19 April 2018 Resolved
Renew Fuel vent pipe on port and starboard tanks
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 19 April 2018 Resolved
Install 30/30 mesh on both port and starboard fuel tank vents
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2018 Resolved
Install ammeter for generator more than 50 volts
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 May 2014 Resolved
Maintain current logs for lifesaving equipment maintenance, drills, and EPIRB checks.
Due 29 May 2014
Resolved 29 May 2014
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 May 2014 Resolved
Provide new hydrostatic release mechanism for EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2014
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 May 2014 Resolved
Provide guards for rotating machinery in Engine Room. (Shafts)
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 18 June 2014
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2012 Resolved
Provide a ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 24 May 2012
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 May 2009 Resolved
Provide MIS report for 2008
Action required: 705 - Other - as specified
Resolved 24 June 2009
Resolution: Report was provided
Construction/Loadline › Penetrations › Flange Pad
Issued 14 May 2009 Resolved
Repair insert on deck for fuel shut off valves, water is penetrating.
Action required: 705 - Other - as specified
Resolved 24 June 2009
Resolution: Insert on deck for fuel shut off valves, where water is penetrating have been repaired
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 May 2009 Resolved
Renew chart and tide table
Action required: 705 - Other - as specified
Resolved 24 June 2009
Resolution: Chart and tide tables have been renewed
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 May 2008 Resolved
replace 5 adult lifejackets
Due 8 May 2008
Resolved 8 May 2008
Engineering › Steering Gear System › Ram Seal
Issued 8 May 2008 Resolved
Repair leak from steering ram.
Due 18 May 2008
Resolved 29 May 2008
Lifesaving › Inflatable Liferafts › Boarding Ramp/Ladder
Issued 8 May 2008 Resolved
Provide a sturdy ladder.
Due 18 May 2008
Resolved 29 May 2008
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 May 2008 Resolved
Repair rot for port side beam in engine room.
Due 18 May 2008
Resolved 29 May 2008
Fire Fighting › Structural - Main Vertical Zones › General
Issued 8 May 2008 Resolved
Repair forward engine room bulkhead to prevent water seapage into the mess deck bilge compartment.
Due 18 May 2008
Resolved 29 May 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 May 2008 Resolved
Type III MSD overboard discharge valve was open and unsecured.
Due 7 May 2008
Resolved 21 June 2011
Resolution: MSD installation/operation is in substantial compliance w/regs.
Lifesaving › Lifefloat › Markings
Issued 12 June 2007 Resolved
Re-label life floats with vessel name as appropriate.
Action required: 705 - Other - as specified
Resolved 13 June 2007
Resolution: Re-labeled.
Lifesaving › Lifefloat › Paddle
Issued 12 June 2007 Resolved
Re-label life float paddles with vessel name.
Action required: 705 - Other - as specified
Resolved 13 June 2007
Resolution: Re-labeled.
Lifesaving › Lifefloat › Netting
Issued 12 June 2007 Resolved
Repair replace stainless steel wire support for 22 person lifefloat basket.
Action required: 705 - Other - as specified
Resolved 13 June 2007
Resolution: Welded new support wire and re-netted life-float basket.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 June 2007 Resolved
Repair/replace #3 lifefloat waterlight.
Action required: 705 - Other - as specified
Resolved 13 June 2007
Resolution: Replaced battery.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 June 2007 Resolved
Replace 02 adult PFDs
Action required: 705 - Other - as specified
Resolved 13 June 2007
Resolution: Purchased (2) new adult PFDs.
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 June 2007 Resolved
Provide current updates for all navigation publications (coast pilot, light list).
Action required: 705 - Other - as specified
Resolved 13 June 2007
Resolution: Updates downloaded for all nav pubs.
Construction/Loadline › Hull › Side Shell
Issued 9 February 2007 Resolved
Complete repairs of wood rot damage in port bow area approx 8-10' from the stem.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 18 April 2007
Resolution: Repairs completed; all sat.
Deck/Cargo › Holds/Tanks › Hatch
Issued 9 February 2007 Resolved
Replace hatch for lazarette, including gasket.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 18 April 2007
Resolution: New hatch cover installed.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 9 February 2007 Resolved
Ensure galley grease extraction hood meets 46 CFR 181.425 and CID Policy letter #20.
Action required: 705 - Other - as specified
Due 9 August 2007
Resolved 13 June 2007
Resolution: As instructed by MI, installed smoke detector in galley area & additional fire extinguisher to satisfy policy requirements.
Construction/Loadline › Hull › Side Shell
Issued 9 February 2007 Resolved
Have wood repair expert inspect crack on starboard side interior of forepeak to access repair necessity.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 18 April 2007
Resolution: Crack in plywood not significant to warrant replacement; non-structural.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 February 2007 Resolved
Remove interior paneling for bulwarks and repair/replace rotted beams and plywood as necessary. Remove marked sections of bulwarks amidships on port and stbd sides and inspect for rot.
Action required: 705 - Other - as specified
Due 9 March 2007
Resolved 18 April 2007
Resolution: Repair of the bulwarks completed; all sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 May 2006 Resolved
Navigation pubs (Coast Pilot [name withheld]) are outdated; vsl has 2002 Editions with no updates. Replace w/new pubs.
Due 17 May 2006
Resolved 19 May 2006
Resolution: Purchased new 2006 publications.
Navigation › Piloting/Steering › Marine Charts
Issued 5 May 2006 Resolved
Vsl's marine chart of the transit area is outdated. Replace w/new chart.
Due 17 May 2006
Resolved 19 May 2006
Resolution: Purchased new charts.
Lifesaving › Hand Flares › Quantity
Issued 5 May 2006 Resolved
Vsl is short three (3) red flares as req'd for limited coastwise route. Until additional flares are purchased, vsl's route is restricted to lakes, bays, and sounds.
Action required: 705 - Other - as specified
Resolved 5 May 2006
Resolution: Additional flares purchased & verified.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 May 2006 Resolved
Rejected fifteen (15) adult PFDs (kapok). Vsl's total person allowance is reduced fm fifty-two (52) to thirty-seven (37) until additional PFDs acquired.
Action required: 705 - Other - as specified
Resolved 15 May 2006
Resolution: Purchased fifteen (15) new adult PFDs.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 May 2006 Resolved
Waterlight on the 15 person lifefloat is inoperable. Repair/replace battery prior to MI departing.
Action required: 705 - Other - as specified
Resolved 5 May 2006
Resolution: Inoperable waterlight fixed on the spot.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2006 Resolved
Several items in first aid kit (aspirin, eye wash sol'n) are past their expiration dates and need to be replaced with new ones. Replace/update expired items.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2006
Resolution: Updated/replaced expired items with new ones.
Lifesaving › Lifefloat › Serviceable
Issued 26 April 2005 Resolved
Repair bird holes in top life float.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 10 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 April 2005 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 10 May 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 April 2005 Resolved
Ensure proper operation of bow bilge high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 10 May 2005
Lifesaving › Lifebuoys
Issued 13 April 2004 Resolved
Renew deteriorated ring buoy.
Due 24 May 2004
Resolved 28 April 2004
Resolution: New life ring was installed
Construction/Loadline › Structures
Issued 13 April 2004 Resolved
Renew hatch hold down devices on watertight hatches for the tank room and lazarette. LEGACY COMPONENT DESC: Scuttle
Condition: Placed in Improper Service
Due 24 May 2004
Resolved 28 April 2004
Resolution: Owner repaired hatch retaining bolts
Engineering › Steering Gear System
Issued 3 December 2003 Resolved
Replace wooden supports just aft of rudder stocks, existing supports are broken. LEGACY COMPONENT DESC: Bracket/Clamp
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2004
Resolution: Owner installed new steel rudder base assembly, new rudders, rebuilt hydraulic ram and all hoses.
Documentation › Logs/Records › Drug Test Records
Issued 28 April 2003 Resolved
Provide proof of current enrollment in drug testing program
Condition: Unknown
Due 15 May 2003
Resolved 14 May 2003
Resolution: Owner provided verification of enrollment with Drug Testing Consultants Inc.
Stability › Weathertight Integrity
Issued 28 April 2003 Resolved
Replace broken bridge windows on both port and starboard side.
Condition: Improper/Lack of Maintenance
Due 15 May 2003
Resolved 13 May 2003
Resolution: Windows were replaced
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 April 2003 Resolved
Provide cover for electrical outlet in the galley, starboard side, under the counter.
Condition: Improper/Lack of Maintenance
Due 15 May 2003
Resolved 13 May 2003
Resolution: Operator installed proper cover on the electrical outlet
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2003 Resolved
Provide metallic wire hangers for electric cables in the pilot house
Condition: Improper Installation
Due 15 May 2003
Resolved 13 May 2003
Resolution: Owner installed proper wire hangers.
Engineering › Fuel Oil Storage/Transfer System
Issued 18 April 2002 Resolved
reattach fuel filter bowl to filter housing in tank room. LEGACY COMPONENT DESC: Filter/Strainer
Condition: Improper/Lack of Maintenance
Due 25 May 2002
Resolved 23 May 2002
Electrical › Electric Supply System (service)
Issued 18 April 2002 Resolved
replace all butt spliced cable in the ER with voltages over 50 volts LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 25 May 2002
Resolved 23 May 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 18 April 2002 Resolved
Properly ground all fuel fill lines. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 25 May 2002
Resolved 23 May 2002
Stability › Watertight Integrity
Issued 18 April 2002 Resolved
Install skin valve in bilge line through hull penetration.
Condition: Improper Installation
Due 25 May 2002
Resolved 23 May 2002
Engineering › Bilge Water Management System
Issued 18 April 2002 Resolved
Clean ER bilges
Condition: Improper/Lack of Maintenance
Due 25 May 2002
Resolved 23 May 2002
Communications › Radio Communications
Issued 18 April 2002 Resolved
FAX EPIRB service information to this office. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Due 25 May 2002
Resolved 23 May 2002
Construction/Loadline › Structures
Issued 18 April 2002 Resolved
Attach capture chain to FWD hatch LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Due 25 May 2002
Resolved 23 May 2002
Navigation › Piloting/Steering
Issued 18 April 2002 Resolved
Update required navigation publications LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 25 May 2002
Resolved 23 May 2002
Lifesaving › Embarkation Appliances/Stations
Issued 18 April 2002 Resolved
Update life float launching configuration LEGACY COMPONENT DESC: Side Ropes
Condition: Improper Installation
Due 25 May 2002
Resolved 23 May 2002
Electrical
Issued 5 November 2001 Resolved
ELECTRICAL WIRING THROUGHOUT VESSEL NEEDS TO BE SECURED WITH METAL HANGERS.46CFR183.340b.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 May 2002
Resolved 23 May 2002
Construction/Loadline
Issued 5 November 2001 Resolved
Make engine room/tank space bulkhead water tight per 46CFR179.320.
Condition: Unknown
Due 25 May 2002
Resolved 23 May 2002
Construction/Loadline
Issued 5 November 2001 Resolved
Replace bilge piping in engine room and at bulkhead penetrations with metallic piping. To comply with 46CFR182.40-5 (old T) or 46CFR182.510 and 46CFR182.710 (new T).
Condition: Unknown
Due 25 May 2002
Resolved 23 May 2002
Engineering
Issued 5 November 2001 Resolved
Fuel hose must be replaced with metallic piping (46CFR182.40.-5 (old T)) orapproved flexible hoses and bulkhead penetrations (46CFR182.455 and 46CFR182.720 (new T)).
Condition: Unknown
Due 25 May 2002
Resolved 19 April 2002
Construction/Loadline
Issued 23 May 2001 Resolved
Install positive shutoff valve on bilge overboard discharge at the hull
Condition: Unknown
Due 5 November 2001
Resolved 21 November 2001
Unknown
Issued 24 April 2000 Resolved
Conduct and log fire, abondon, and man overboard drills and training as per46/185.520 & .524.
Condition: Unknown
Due 24 April 2000
Resolved 24 April 2000
Unknown
Issued 24 April 2000 Resolved
Remove wet rot and treat affected area on side keelson located starboard side of generator.
Condition: Unknown
Due 14 May 2000
Resolved 14 May 2000
Construction/Loadline
Issued 24 April 2000 Resolved
Show proper operation/good working condition of bilge high level alarm in compartment aft of collision bulkhead, as per 46/182.530.
Condition: Unknown
Due 14 May 2000
Resolved 14 May 2000
Construction/Loadline
Issued 24 April 2000 Resolved
Label valves handles or bilge piping manifold to clearly identify which compartment each valve serves, as per 46/176.800.
Condition: Unknown
Due 14 May 2000
Resolved 14 May 2000
Fire Fighting
Issued 24 April 2000 Resolved
Provide three (2-1/2 gallon) buckets for fire fighting, as per 46/181.610 or provide ferrous material piping for fire main system, as per 46/182.710(c).
Condition: Unknown
Due 14 May 2000
Resolved 14 May 2000
Accommodation/Occupational Safety
Issued 24 April 2000 Resolved
Mark galley's emergency exit as specified by 46/185.606.
Condition: Unknown
Due 14 May 2000
Resolved 14 May 2000
Construction/Loadline
Issued 15 February 2000 Resolved
Prior to carrying passengers for hire, vessel must conduct an after drydockcheckride.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Fire Fighting
Issued 16 September 1999 Resolved
Submit plans for approval to the inspections department for the installation of gas tight inspection doors at the forward bulkhead of the engine room where the port and starboard companionways extend forward underthe galley.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Fire Fighting
Issued 16 September 1999 Resolved
Ensure a method of closing all engine room vents, in case of a fire, is permanently installed on the vessel.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Electrical
Issued 28 May 1998 Resolved
PROVIDE PROOF THAT EMERGENCY LIGHTING FOR PASSENGER ACCOMMODATION SPACE WORKS.
Condition: Unknown
Due 29 May 1998
Resolved 26 June 1998
Electrical
Issued 28 May 1998 Resolved
PROVIDE LABELS FOR CIRCUIT BREAKER PANEL LOCATED IN THE ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1998
Resolved 26 June 1998
Navigation
Issued 28 May 1998 Resolved
PROVIDE VESSEL WITH DEVIATION TABLE.
Condition: Unknown
Due 29 May 1998
Resolved 26 June 1998
Engineering
Issued 28 May 1998 Resolved
PROVIDE FLAME BOWL FOR FUEL FILTER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1998
Resolved 26 June 1998
Lifesaving
Issued 28 May 1998 Resolved
REPLACE PENDANTS AND LIFELINE ON LIFEFLOAT.
Condition: Unknown
Due 29 May 1998
Resolved 26 June 1998
Electrical
Issued 28 May 1998 Resolved
SECURE PORT AND STARBOARD BATTERIES LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 29 May 1998
Resolved 26 June 1998
Navigation
Issued 28 May 1998 Resolved
PROVIDE VESSEL WITH TIDE AND CURRENT TABLES.
Condition: Unknown
Due 29 May 1998
Resolved 26 June 1998
Navigation
Issued 28 May 1998 Resolved
SECURE PAINTER FOR LIFEFLOAT SO IT RUNS OUT FREELY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1998
Resolved 26 June 1998
Lifesaving
Issued 8 October 1996 Resolved
Stencil vessel's new name on lifefloats._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Lifesaving
Issued 8 October 1996 Resolved
Fix bulb in life ring waterlight.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Lifesaving
Issued 8 October 1996 Resolved
Replace three expired red signal flares.
Condition: Unknown
Due 9 October 1996
Resolved 15 October 1996
Navigation
Issued 24 April 1996 Resolved
PROVE PROPER OF VESSEL'S NAVIGATION LIGHTS.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 24 April 1996 Resolved
Conduct underway hull exam prior to credit being given for this drydock.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 17 March 1995 Resolved
PERMANENTLY REPAIR THE GRAB LINE SECURING EYE TO THE 16 POB BUOYANT APP.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 27 October 1994 Resolved
MAKE BULKHEAD PENETRATIONS WATERTIGHT IN 1ST WATERTIGHT BULKHEAD AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Fire Fighting
Issued 27 October 1994 Resolved
REPLACE OR SERVICE ONE B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 27 October 1994 Resolved
TREAT MINOR FURRING IN WAY OF 3RD DECK STRINGER AFT OF COLLISION BULKHEAD, ON PORT AND STARBOARD SIDE.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Engineering
Issued 27 October 1994 Resolved
PROVIDE VENTILILATION TO MACHINERY SPACE (LOWEST PART OF THE BILGE) IN ACCORDANCE WITH 46CFR182.20-45.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 27 October 1994 Resolved
MAKE REPAIRS TO BLISTER ON PORT SIDE LOCATED ONE FOOT FORWARD OF PORT RUNNING LIGHT, NINE INCHES ABOVE WATERLINE AND BELOW RUB RAIL.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Lifesaving
Issued 21 May 1993 Resolved
PROVIDE ONE ADDITIONAL ADULT LIFE JACKET
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Construction/Loadline
Issued 21 May 1993 Resolved
REPALACE GASKET MATERIAL ON FORE PEAK AND FUEL TANK COMPT DECK OPENNINGS.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Engineering
Issued 21 May 1993 Resolved
RE-INSTALL FLAME CUP ON PORT RACOR FILTER.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Construction/Loadline
Issued 21 May 1993 Resolved
PROVIDE SUFFICIENT FREEING PORT AREA (110 SQ. INCHES) IN ACCORDEANCE WITH 46 CFR 171.150.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 27 May 1992 Resolved
PROVIDE WEAK LINK FOR 32 PERSON B/A.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Construction/Loadline
Issued 27 May 1992 Resolved
REPAIR LEAKY BILGE PUMP PIPING ON STBD ENGINE BELOW MECHANICAL BILGE PUMP.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Lifesaving
Issued 27 May 1992 Resolved
PROVIDE WATERLIGHTS FOR BUOYANT APPARATUS. REMOVE CANISTERS.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Accommodation/Occupational Safety
Issued 27 May 1992 Resolved
PROVIDE MSD WITH OVERBOARD DISCHARGE VALVE WITH LOCKING DEVICES.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Electrical
Issued 27 May 1992 Resolved
PROVIDE GLASS AND CAGE FOR ALL LIGHT FIXTURES.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Lifesaving
Issued 27 May 1992 Resolved
MARK EMERGENCY ESCAPE HATCH SIGN WITH "DO NOT BLOCK."
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Construction/Loadline
Issued 27 May 1992 Resolved
SCRAPE AND TREAT ROT IN COMPARTMENT FORWARD OF LAZARETTE ON 1ST AND 2ND TRANSVERSE DECK STIFFENER AND ON DECK IN WAY OF THE PORT FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Lifesaving
Issued 27 May 1992 Resolved
PROVIDE 4 ADULT PFD'S.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Lifesaving
Issued 27 May 1992 Resolved
PROVIDE ADEQUATE HOSE FOR HAND FIRE/BILGE PUMP TO OPERATE IT FROM MAIN DECKOVER BULWARKS.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Engineering
Issued 13 December 1991 Resolved
PROVIDE LOCKING PINS FOR RAMS IN E/R.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Navigation
Issued 13 December 1991 Resolved
PROVIDE HOSE CLAMPS ON HYDRAULIC LINES IN LAZ.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Construction/Loadline
Issued 13 December 1991 Resolved
REPLACE BILGE SUCTION SCREEN IN 2ND COMPARTMENT FROM STERN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Construction/Loadline
Issued 13 December 1991 Resolved
REPLACE SUCTION HEAD IN SECOND COMPARTMENT FROM THE BOW.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Documentation
Issued 8 May 1991 Resolved
PROVIDE WRITTEN TRASH DISPOSAL PLAN.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Documentation
Issued 8 May 1991 Resolved
PROVIDE CURRENT FCC STATION LISCENSE AND OPERATORS PERMIT.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Navigation
Issued 8 May 1991 Resolved
PROVIDE CURRENT COMPASS DEVIATION TABLE.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Lifesaving
Issued 8 May 1991 Resolved
PROCVIDE 4 ADULT AND 1 CHILD PFD. UNTIL THESE PFDS ARE PROVIDED TOTAL PERSONS IS LIMITED TO 38 AND NO MORE THAN 4 CHILDREN MAY BE CARRIED.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Construction/Loadline
Issued 11 May 1990 Resolved
4 REPLACE SHEATHING IN CHAIN LOCKER ON PORT SIDE NEAR STEM WHERE IT HAS COME LOOSE.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Engineering
Issued 11 May 1990 Resolved
1 FASTEN PORT SHAFT LOG PLANKING NEXT TO ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Construction/Loadline
Issued 11 May 1990 Resolved
2 REPLACE APPROXIMATELY 12 INCH X 15 INCH ROTTED SECTION OF FORWARD FUEL SPACE BULKHEAD ON STBD SIDE.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Engineering
Issued 11 May 1990 Resolved
3 PROVIDE HAND PROTECTION FOR EMERGENCY FUEL SHUT OFFS.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Engineering
Issued 1 May 1989 Resolved
DRILL AND PIN OF DOUBLE NUT THROTTLE CABLE CONNECTIONS IN ENGINE WING SPACES.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Construction/Loadline
Issued 1 May 1989 Resolved
REMOVE AND TREAT ROTTED NON-STRUCTURAL WOOD MEMBERS IN PORT ENGINE WING SPACE.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Lifesaving
Issued 1 May 1989 Resolved
INSTALL REFLECTIVE TAPE ON BOTH BA'S.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Accommodation/Occupational Safety
Issued 1 May 1989 Resolved
PROVIDE APPROPRIATE SIZE WRENCH AND ATTACH IT TO 1 AND A 1/2 INCH BAIT TANKGATE VALVE UNTIL REPLACEMENT HANDLE CAN BE OBTAINED.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Electrical
Issued 16 May 1988 Resolved
REPLACE EXPLOSION PROOF COVERS AND CAGES ON REAR OF PORT ENGINE AND FOWARD OF STARBOARD ENGINE.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Construction/Loadline
Issued 16 May 1988 Resolved
REPLACE DRY ROTTED WOOD AROUND FOWARD HATCH.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Lifesaving
Issued 11 February 1987 Resolved
1. PROVIDE 4 ADULT LIFE PRESERVERS TO BRING THE TOTAL TO 42 ADULT AND 5 CHILDREN. THE VESSEL IS RESTRICTED TO THE CARRIAGE OF 35 PASSENGERS UNTIL ITEM ONE IS COMPLETED.
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987
Engineering
Issued 22 November 1985 Resolved
REPAIR PORT FUEL FILTER ON PORT MAIN ENGINE AND PROVE OPERATION
Condition: Unknown
Due 22 November 1985
Resolved 22 November 1985
Construction/Loadline
Issued 22 November 1985 Resolved
REPLACE PORT HORIZONTAL UNDERDECK BEAM AT SIDESHELL IN LAZARETTE USING EQUIVALENT WOOD AND GOOD MARINE PRACTICE.
Condition: Unknown
Due 22 November 1985
Resolved 22 November 1985
Construction/Loadline
Issued 15 February 1985 Resolved
MAKE PERMANENT REPAIRS TO DETERIORATED TRANSVERSE UNDERDECK FRAME IN LAZAR-ETTE AT FORWARD BULKHEAD USING EQUIVALENT WOOD AND GOOD MARINE PRACTICE.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Documentation
Issued 15 February 1985 Resolved
PROVIDE AND POST STABILITY LETTER FOR VESSEL.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985

Ownership record