Records from 2016 to 2026. Most recent: inspection, 29 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)53.1 ft × 18.0 ft × 4.7 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICHARD A MATHENY · COSTA MESA, CA, UNITED STATES · built 1958
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 14 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
29 April 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8358400
8 May 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8132076
17 April 2025
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8113018
22 October 2024
In-Service Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023518
6 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7929510
28 June 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818931
2 May 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7679832
2 June 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7447235
24 June 2021
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7235113
7 April 2021
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169942
4 June 2020
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6971231
30 March 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6933326
11 June 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6710487
16 April 2019
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6724573
19 April 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6394928
25 April 2017
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6136286
18 May 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5880526
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2026
Resolved
Observed a non-rigid rescue ladder. Vessel is to have deployable rigid rescue ladder with an assist line, sufficient rung space/s, and the side of the hull for proper footing (capable of supporting at least 2 persons-370LBS).
46CFR175.118(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2026
Resolution: POC provided images of new rescue ladder. All SAT
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 29 April 2026
Resolved
Observed FCC Radio Authorization station permit expired. Vessel is renew permit and provide proof of new authorization station permit.
47CFR80
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2026
Resolution: POC provided images of new FCC documents. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 June 2024
Resolved
The storage container for the distress flares was found wasted and not water-tight. Provide flares with a water-tight container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 12 June 2024
Resolution: Vessel was provided with a water-tight container.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 June 2022
Resolved
POSTED COD was expired. VSL was able to provide proof of updated COD before MI departure.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 3 June 2022
Resolution: Corrected
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 June 2021
Resolved
Navigational charts not carried onboard.
Add to onboard inventory / publications.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received Photo's satisfying requirements.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 June 2021
Resolved
Salon / Messdeck area Smoke detector missing from ceiling
mount. Install and test operation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received video of installation and Satisfactory Op-test of smoke detector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 June 2021
Resolved
Portside main deck remote fuel valve shut-off cabling failed during actuation. Repair / replace cable & optest
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2021
Resolved 24 June 2021
Resolution: Received video of cable replacement & operational test; All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021
Resolved
Electrical extension cord being used for galley microwave equipment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received photo of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021
Resolved
Electrical light fixture at operation station missing cable penetration. Provide cable cap / plug.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received photo of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2019
Resolved
Replace broken fuel oil shut-off valve on the stbd fuel tank.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2019
Resolution: Valve was replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 11 June 2019
Resolved
Make collision bulkhead water-tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Collision bulkhead was resealed and made water-tight.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2019
Resolved
Provide generator fuel hoses with double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Hoses were provided with double clamps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2019
Resolved
Provide port bait pump with electrical junction box for cable connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Junction box was installed and connections were enclosed within.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 19 April 2018
Resolved
Renew Fuel vent pipe on port and starboard tanks
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 19 April 2018
Resolved
Install 30/30 mesh on both port and starboard fuel tank vents
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2018
Resolved
Install ammeter for generator more than 50 volts
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018