MAURY USCG vessel records
← All vessels

CHUBASCO II

CHUBASCO II is a 1958 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in April 2026, along with 16 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 29 April 2026.

Built
1958
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD2019
Flag
UNITED STATES
Maury page id
psix-43593

Documentation record

Registered dimensions (L × B × D)53.1 ft × 18.0 ft × 4.7 ft
Registered tonnagegross 37 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICHARD A MATHENY · COSTA MESA, CA, UNITED STATES · built 1958
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 14 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

29 April 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8358400
8 May 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8132076
17 April 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8113018
22 October 2024 In-Service Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023518
6 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7929510
28 June 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818931
2 May 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7679832
2 June 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7447235
24 June 2021 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7235113
7 April 2021 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169942
4 June 2020 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6971231
30 March 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6933326
11 June 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6710487
16 April 2019 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6724573
19 April 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6394928
25 April 2017 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6136286
18 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5880526

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2026 Resolved
Observed a non-rigid rescue ladder. Vessel is to have deployable rigid rescue ladder with an assist line, sufficient rung space/s, and the side of the hull for proper footing (capable of supporting at least 2 persons-370LBS). 46CFR175.118(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2026
Resolution: POC provided images of new rescue ladder. All SAT
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 29 April 2026 Resolved
Observed FCC Radio Authorization station permit expired. Vessel is renew permit and provide proof of new authorization station permit. 47CFR80
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2026
Resolution: POC provided images of new FCC documents. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 June 2024 Resolved
The storage container for the distress flares was found wasted and not water-tight. Provide flares with a water-tight container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 12 June 2024
Resolution: Vessel was provided with a water-tight container.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 June 2022 Resolved
POSTED COD was expired. VSL was able to provide proof of updated COD before MI departure.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 3 June 2022
Resolution: Corrected
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 June 2021 Resolved
Navigational charts not carried onboard. Add to onboard inventory / publications.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received Photo's satisfying requirements.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 June 2021 Resolved
Salon / Messdeck area Smoke detector missing from ceiling mount. Install and test operation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received video of installation and Satisfactory Op-test of smoke detector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 June 2021 Resolved
Portside main deck remote fuel valve shut-off cabling failed during actuation. Repair / replace cable & optest
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2021
Resolved 24 June 2021
Resolution: Received video of cable replacement & operational test; All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021 Resolved
Electrical extension cord being used for galley microwave equipment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received photo of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021 Resolved
Electrical light fixture at operation station missing cable penetration. Provide cable cap / plug.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2021
Resolved 24 June 2021
Resolution: Received photo of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2019 Resolved
Replace broken fuel oil shut-off valve on the stbd fuel tank.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2019
Resolution: Valve was replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 11 June 2019 Resolved
Make collision bulkhead water-tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Collision bulkhead was resealed and made water-tight.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2019 Resolved
Provide generator fuel hoses with double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Hoses were provided with double clamps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2019 Resolved
Provide port bait pump with electrical junction box for cable connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 June 2019
Resolution: Junction box was installed and connections were enclosed within.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 19 April 2018 Resolved
Renew Fuel vent pipe on port and starboard tanks
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 19 April 2018 Resolved
Install 30/30 mesh on both port and starboard fuel tank vents
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2018 Resolved
Install ammeter for generator more than 50 volts
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 11 June 2018

Ownership record