Records from 1996 to 2016. Most recent: inspection, 8 December 2016.
Inspection history · 26
8 December 2016
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6054575
10 December 2015
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5778626
14 December 2010
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3910500
23 February 2010
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3684851
2 March 2009
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3427339
9 December 2008
Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3377555
12 December 2007
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3113750
9 March 2007
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2884619
19 January 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2564863
16 December 2004
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2260564
17 September 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2237668
14 April 2004
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2043996
19 February 2004
Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2000452
20 November 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1951527
17 September 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1913061
21 February 2003
Administrative Inspection · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1730771
10 December 2002
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1716909
5 October 1999
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1045800
31 August 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1410168
25 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884743
14 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 796256
24 June 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469185
17 June 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 775970
8 May 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390507
8 July 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087043
1 May 1996
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454323
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 December 2016
No resolution recorded
Complete a credit hull exam. Vessel hull exam is overdue as of 04Dec16
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2017 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder
Issued 10 December 2015
Resolved
Replace rudder tie bar
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2016
Resolved 15 December 2015
Resolution: Vessel replaced tie bar.
Engineering › Fuel Oil Service System › Valve
Issued 10 December 2015
Resolved
Repair emergency fuel shutoff valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2016
Resolved 15 December 2015
Resolution: Vessel repaired valve
Lifesaving › Lifebuoys › Serviceable
Issued 10 December 2015
Resolved
Replace ring buoy
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 15 December 2015
Resolution: Vessel replaced ring buoy
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 December 2015
Resolved
Provide cover/junction box for terminal strip in head
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 15 December 2015
Resolution: Vessel provided enclosure.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 December 2015
Resolved
Replace light cover in port side berth
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 15 December 2015
Resolution: Vessel replaced cover
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 10 December 2015
Resolved
Repair exhaust leak on STBD engine
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 15 December 2015
Resolution: Vessel repaired exhaust leak
Engineering › Fuel Oil Service System › Valve, Control
Issued 2 March 2009
Resolved
REPAIR/REPLACE REMOTE FUEL SHUTOFF VALVE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2009
Electrical › Electric Supply System (service) › Cable
Issued 2 March 2009
Resolved
REMOVE DEADEND CABLE FOR OLD TRANSDUCER IN THE ENGINE ROOM.
Due 16 March 2009
Resolved 3 March 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 March 2009
Resolved
RESTENCILE LIFEBUOY.
Due 9 March 2009
Resolved 3 March 2009
Communications › Radio Communications › EPIRB
Issued 11 December 2007
Resolved
Provide proof of battery expiration date for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2007
Resolution: POC faxed a copy of a receipt from Sound Marine Electronics for an EPIRB battery with a 5 year life dated 20FEB2004. Called Electronics company to confirm validity of receipt, ALL SAT
Navigation › Piloting/Steering › Marine Charts
Issued 11 December 2007
Resolved
Provide vessel with new or up-to-date charts.
Condition: Improper/Lack of Maintenance
Due 19 December 2007
Resolved 4 January 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 December 2007
Resolved
Repair engine room portable fire extinguisher bracket.
Condition: Improper/Lack of Maintenance
Due 19 December 2007
Resolved 4 January 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 11 December 2007
Resolved
Ensure proper operation of smoke detectors.
Condition: Improper/Lack of Maintenance
Due 19 December 2007
Resolved 4 January 2008
Resolution: Vsl CAPT replaced batteries in all smoke detectors, all are now operational and were tested by a Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 December 2007
Resolved
Provide First Aid with Ammonia inhalants.
Condition: Improper/Lack of Maintenance
Due 19 December 2007
Resolved 4 January 2008
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 9 March 2007
Resolved
Replace overhead fire protection IWO the machinery space as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2007
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 9 March 2007
Resolved
Prove proper operation of both high level bilge alarms.
Due 23 March 2007
Resolved 19 March 2007
Resolution: A new system was installed. Test SAT.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 March 2007
Resolved
Update first aid kit (replace outdated items).
Due 23 March 2007
Resolved 19 March 2007
Resolution: New kit was purchased.
Engineering › Bilge Water Management System › Strainer
Issued 16 December 2004
Resolved
Repair/replace missing bilge pipe strainer on the FWD most pick up tube.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 17 February 2005
Engineering › Bilge Water Management System › Valve
Issued 16 December 2004
Resolved
Repair reach rod to valve in FWD void.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 17 February 2005
Stability › Watertight Integrity › General
Issued 16 December 2004
Resolved
Patch 2 holes in FWD BLKHD as discussed.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 17 February 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 16 December 2004
Resolved
Prior to the carriage of passengers, prove proper installation and operation of your new PORT engine.
Condition: Unknown
Due 16 December 2004
Resolved 17 February 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 December 2004
Resolved
Provide 50% of crew with Red Cross / CPR cards/training IAW NVIC 1-91. Cards are all expired.
Condition: Improper/Lack of Maintenance
Due 17 March 2005
Resolved 23 March 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 December 2004
Resolved
Update nautical publications IAW 46CFR184.420. They had last years editions with no updates.
Condition: Improper/Lack of Maintenance
Due 28 February 2005
Resolved 28 February 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 16 December 2004
Resolved
Prior to the carriage of passengers, repair the high bilge level alarm in AFT steering space IAW 46CFR182.530. No signal to the bridge once float switch was lifted.
Condition: Improper/Lack of Maintenance
Due 17 February 2005
Resolved 28 February 2005
Engineering › Fuel Oil Service System › Filter
Issued 16 December 2004
Resolved
Provide metal plugs for flame bowls on all Racor filters. They have plastic installed.
Condition: Improper Installation
Due 28 February 2005
Resolved 28 February 2005
Engineering › Bilge Water Management System › Pump
Issued 16 December 2004
Resolved
Provide a 5 GPM portable hand pump IAW 46CFR182.25-10(a). No hand pump onboard.
Condition: Improper/Lack of Maintenance
Due 28 February 2005
Resolved 28 February 2005
Engineering › Bilge Water Management System › Manifold
Issued 16 December 2004
Resolved
Label 2nd valve in from the left, when looking at manifold. Missing label on valve for bilge manifold system.
Condition: Improper/Lack of Maintenance
Due 28 February 2005
Resolved 28 February 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 December 2004
Resolved
Relocate or seperate child size life preservers from adults IAW 46CFR180.25-10(c). All life jackets are together under the STBD cabin seat. Properly labeled, just together with no seperation.
Condition: Improper Installation
Due 28 February 2005
Resolved 28 February 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 April 2004
Resolved
INSTALL AND PROVE PROPER OPERATION OF FIXED FIREFIGHTING SYSTEM IAW MANUFACTURER INSTRUCTIONS AND APPROVED PLANS. LEGACY COMPONENT DESC: Installation
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 17 September 2004
Resolution: FIREBOY MA-900.
Construction/Loadline › Structures
Issued 19 February 2004
Resolved
REPAIR STBD CABIN WINDOW. LEGACY COMPONENT DESC: Windows
Due 19 March 2004
Resolved 23 February 2004
Operations/Management › Drills/Instruction
Issued 19 February 2004
Resolved
INITIATE CREW TRAINING/DRILL LOGS (MAN OVERBOARD, FIRE, ABANDON SHIP, EPIRB). LEGACY COMPONENT DESC: Logs
Due 19 March 2004
Resolved 23 February 2004
Resolution: ISSUED LOF EXAMPLES.
Lifesaving › Lifejacket/PFD (Type I)
Issued 19 February 2004
Resolved
PROVIDE 2 ADDITIONAL ADULT TYPE I LIFEJACKETS AND 1 LIFEJACKET WATERLIGHT. TOTAL PERSONS REDUCED TO 18 UNTIL COMPLETED. LEGACY COMPONENT DESC: Quantity
Due 4 March 2004
Resolved 23 February 2004
Resolution: SAT
Communications › Radio Communications
Issued 19 February 2004
Resolved
REPLACE EPIRB BATTERY PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: EPIRB
Due 22 February 2004
Resolved 23 February 2004
Resolution: SAT
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 19 February 2004
Resolved
SUBMIT PLANS FOR INSTALLATION OF REQUIRED FIXED FIREFIGHTING SYSTEM. PROVIDE ENGINE ROOM SPACE CALCULATION, PROPOSED LOCATION OF BOTTLE, MAUNUAL PULL, CONTROLS, AND VENTILLATION STOPS.
Condition: Improper Installation
Due 19 March 2004
Resolved 14 April 2004
Resolution: ISSUED PLAN APPROVAL LETTER.
Lifesaving › Hand Flares
Issued 19 February 2004
Resolved
PROVIDE 9 ADDITIONAL HANDHELD DAY/NIGHT FLARES PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Quantity
Due 4 March 2004
Resolved 23 February 2004
Resolution: SAT
Engineering › Bilge Water Management System
Issued 19 February 2004
Resolved
REPAIR BILGE/FIRE PUMP PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Pump
Due 4 March 2004
Resolved 23 February 2004
Resolution: TESTED PUMP.
Communications › Radio Communications
Issued 21 February 2003
Resolved
UPDATE FCC RADIOTELEPHONE SAFETY CERTIFICATE. LEGACY COMPONENT DESC: Safety Certificate
Due 21 March 2003
Resolved 17 September 2003
Resolution: Rcv''d Radiotelephone Safety Certificate issued 29APR03.
Lifesaving
Issued 31 August 1999
Resolved
PROVIDE PROOF OF DRUG TESTING AS REQUIRED BY 46 CFR 16.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Unknown
Issued 31 August 1999
Resolved
REPLACE COMPRESSION FITTINGS ON STEERING HOSES.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Unknown
Issued 31 August 1999
Resolved
PROVIDE SCREEN ON MSD VENTILATION PIPE AS REQUIRED BY 33 CFR 159.95(a)(2).
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Unknown
Issued 31 August 1999
Resolved
PROVIDE DERATING PLACARD ON SHIPS SERVICE GENERATOR AS REQUIRED BY 46 CFR 183.320(e).
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Documentation
Issued 31 August 1999
Resolved
PROVIDE SAFETY RADIO TELEPHONE CERTIFICATE AND OPERATORS PERMIT AS REQUIREDBY 47CFR80.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Unknown
Issued 31 August 1999
Resolved
PROVIDE 3/4 FULL VOLUME INDICATOR ON MSD HOLDING TANK AS REQUIRED BY 33 CFR159.83._x001C_
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Lifesaving
Issued 8 May 1997
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Lifesaving
Issued 8 May 1997
Resolved
PAINT AND LABEL DISTRESS SIGNAL BOX
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Unknown
Issued 8 May 1997
Resolved
PROVIDE PROOF OF CHEMICAL TESTING PROGRAM IN ACCORDANCE WITH 46 CFR PART 16
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Documentation
Issued 1 May 1996
Resolved
PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE AND FCC STATION LICENSE
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996