Records from 1984 to 2022. Most recent: inspection, 3 March 2022.
Inspection history · 60
3 March 2022
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7405523
1 July 2009
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3520585
30 June 2008
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3252858
9 November 2007
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3096082
27 June 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2694431
23 May 2006
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2656828
27 February 2006
Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2592845
27 May 2005
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2369050
8 July 2004
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2091711
19 February 2004
Hull Examination · Administrative Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2007912
19 May 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1796837
27 February 2002
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1488628
14 November 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 772149
8 November 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 772323
4 September 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1389465
5 June 2000
COI Inspection · Plan Review "T" Boat
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372925
19 April 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 817607
23 March 1998
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1122511
2 June 1997
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1109165
17 March 1997
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1096684
12 February 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371666
27 January 1997
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1100933
8 January 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363911
14 August 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 943818
13 August 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367892
24 June 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367749
10 April 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385675
17 January 1996
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374470
5 January 1996
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359019
6 January 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353683
15 December 1994
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354717
3 December 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 847816
20 October 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356437
14 August 1993
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1447287
29 December 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1140149
30 November 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 829913
9 March 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 960152
27 February 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661212
10 February 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 63739
2 January 1992
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1266902
19 December 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661211
2 December 1991
Drydock Extension · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1251332
10 December 1990
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 929056
21 June 1990
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 931923
2 March 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 916970
15 December 1989
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1220818
15 December 1989
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1233405
20 January 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 892664
13 January 1989
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1201896
2 December 1988
COI Inspection · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341494
11 April 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1202204
21 December 1987
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1005491
17 November 1987
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1026331
12 August 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1340873
1 June 1987
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1028110
2 December 1986
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1022181
31 December 1985
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990308
6 December 1985
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1293331
18 December 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 977611
7 December 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 976584
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 June 2008
Resolved
Credit dry-dock was due NLT 31 MAY 08. Complete credit dry-dock prior to carry passengers for hire
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2022
Resolution: Contacted PSI and previous owner. Vessel was sold to an individual who failed to pay mooring fees. State confiscated vessel and failed to auction it. PSI scrapped vessel in March of 2018.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 June 2006
Resolved
Provide rail at upper deck aft which is capable of supporting 200lbs IAW 46CFR177.90
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 31 July 2006
Lifesaving › Lifebuoys › Serviceable
Issued 28 June 2006
Resolved
Replace all ringbouys, ensure ringbouys are not wasted IAW 46CFR180.70
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 6 July 2006
Resolution: Vsl provided three new ring bouys that were IAW 46CFR180.70
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 June 2006
Resolved
Provide evidence of proper operation of visual bilge alarm indicators IAW 46CFR182.530
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 31 July 2006
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 28 June 2006
Resolved
Ensure that Gas Grill at stern is installed IAW 46CFR184.240, reference NFPA 302 chapter 6 ABYC A-1 Marine liquified Petroleum Gas systems
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 6 July 2006
Resolution: It was determined by the OCMI that the vsl''s grill installation was proper
Stability › Weathertight Integrity › General
Issued 28 June 2006
Resolved
Provide chains/ropes for hatches on the weather deck IAW 46CFR171.124
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 6 July 2006
Resolution: Vsl provided ropes for hatches on the weather deck
Construction/Loadline › Structures › Superstructure
Issued 23 May 2006
Resolved
Replace rotted wood mount for hot water heater
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 31 May 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 May 2006
Resolved
Tighten all S/W cooling hoses main engines.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 31 May 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 23 May 2006
Resolved
Connect ground wire for fuel tank
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 31 May 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 23 May 2006
Resolved
Prove operation of all bilge alarms
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 31 May 2006
Construction/Loadline › Hull
Issued 27 February 2002
Resolved
Repair FRP crack on port stabilizer fin port outboard side. LEGACY COMPONENT DESC: Stabilizer Fin
Due 27 February 2002
Resolved 28 February 2002
Resolution: Vessel operator repaired FRP crack on stabilizer fin, port outboard side.
Construction/Loadline › Hull
Issued 27 February 2002
Resolved
Repair FRP above port rudder. LEGACY COMPONENT DESC: Rudder
Due 27 February 2002
Resolved 28 February 2002
Resolution: Vessel operator made FRP repairs above the port rudder.
Construction/Loadline › Hull
Issued 27 February 2002
Resolved
Repair cracks in FRP on both port and starboard rudders. LEGACY COMPONENT DESC: Rudder
Due 27 February 2002
Resolved 28 February 2002
Resolution: Vessel operator made repairs to FRP on both port and starboard rudders.
Construction/Loadline › Hull
Issued 27 February 2002
Resolved
Repair FRP area aft of the drydock block on the starboard side.
Due 27 February 2002
Resolved 28 February 2002
Resolution: Vessel operator made repairs to FRP aft of the drydock block on the starboard side.
Documentation
Issued 4 September 2001
Resolved
Provide documentation of 60-minute drug/alcohol program training for supervisors in accordance with 46 CFR 16.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Documentation
Issued 4 September 2001
Resolved
Submit Management Information System (MIS) Form to Commandant in accordancewith 46 CFR 16.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001
Resolved
Provide documentation of crew training in accordance with 46 CFR 185.420.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001
Resolved
Post emergency instructions in accordance with 46 CFR 185.510.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Navigation
Issued 4 September 2001
Resolved
Provide Tide Tables and Current Tables in accordance with 46 CFR 184.420.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001
Resolved
Provide internal communications in accordance with 46 CFR 184.602.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001
Resolved
Post a durable emergency broadcast placard in accordance with 46 CFR 184.506.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001
Resolved
Provide a public address system in accordance with 46 CFR 184.610.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001
Resolved
Provide (11) additional adult PFD's to bring count to (137) in accordance with 46 CFR 180.71. Passenger count is reduced to (114) until provided.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001
Resolved
Provide retro-reflective tape for all (3) ring life buoys in accordance with 46 CFR 185.604.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Engineering
Issued 4 September 2001
Resolved
Renew ventilation duct in the starboard fuel tank compartment in accordancewith 46 CFR 182.465.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Fire Fighting
Issued 4 September 2001
Resolved
Provide a means to close ventilation for areas protected by fixed fire fighting systems in accordance with 46 CFR 182.465(h).
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Fire Fighting
Issued 4 September 2001
Resolved
Demonstrate proper operation of the fire pump in accordance with 46 CFR 181.300 prior to sailing with passengers._x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Engineering
Issued 4 September 2001
Resolved
Prove pilothouse control of propulsion in accordance with 46 CFR 184.620.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 4 September 2001
Resolved
Provide a visual and audible alarm at the operator station for the bilge high level alarm in accordance with 46 CFR 182.530. _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001
Resolved
Conduct fire and abandon ship drills with new crew in the presence of a USCG Marine Inspector prior to sailing with passengers.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Documentation
Issued 4 September 2001
Resolved
Post stability letter in accordance with 46 CFR 176.306.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Accommodation/Occupational Safety
Issued 4 September 2001
Resolved
Post Small Passenger Vessel (SPV) Decal in accordance with 46 CFR 176.310.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Accommodation/Occupational Safety
Issued 4 September 2001
Resolved
Post station bill in accordance with 46 CFR 185.514.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Accommodation/Occupational Safety
Issued 4 September 2001
Resolved
Provide a waste management plan in accordance with 33 CFR 151.57.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Accommodation/Occupational Safety
Issued 4 September 2001
Resolved
Provide Red Cross First Aid/CPR cards for 50% of new crew in accordance with NVIC 1-91.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Fire Fighting
Issued 8 January 1997
Resolved
Provide fire extinguisher servicing report.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Electrical
Issued 8 January 1997
Resolved
Prove operation of starboard generator.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Construction/Loadline
Issued 8 January 1997
Resolved
Prove operation of bilge system forward of collision bulkhead (port and starboard).
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Documentation
Issued 8 January 1997
Resolved
Provide Certificate of Documentation on board vessel.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Engineering
Issued 17 January 1996
Resolved
REPAIR MINOR FUEL LEAK IN FUEL LINE LOCATED APPROXIMATELY 10 FEET AFT OF STARBOARD FUEL TANK. REPAIR TO BE COMPLETED PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Construction/Loadline
Issued 17 January 1996
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REMOVE VESSEL FROM WATER FOR FURTHEREXAMINATION OF POSSIBLE WOOD ROT IN AREA OF STARBOARD ENGINE. EXAMINATION OF SOURCE OF WATER LEAK AND CONDITION OF WOOD TO BE CONDUCTED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Electrical
Issued 5 January 1996
Resolved
Provide battery box and isolating transformer for batteries in port generator room in accordance with 46 CFR 183.05-20.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Documentation
Issued 5 January 1996
Resolved
Provide FCC safety certificate, station license and operator's license.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Documentation
Issued 5 January 1996
Resolved
Provide documentation of employee assistance program training in accordancewith 46 CFR 16._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Construction/Loadline
Issued 5 January 1996
Resolved
Replace flexible bilge hose with metallic piping in port and starboard fueltank spaces.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Engineering
Issued 5 January 1996
Resolved
Replace flexible fuel hose with USCG approved flexible fuel hose on all fuel tanks in accordance with 46 CFR 182.20-40 (6 each).
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Electrical
Issued 5 January 1996
Resolved
Prove operation of starboard generator.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Lifesaving
Issued 5 January 1996
Resolved
Provide proper retroreflective tape and markings for 56 adult and 1 child life preservers. Vessel is restricted to the carriage of 86 persons (including crew) until corrected.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Construction/Loadline
Issued 5 January 1996
Resolved
Cap unused throughhull fittings in port and starboard MSD spaces.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Navigation
Issued 5 January 1996
Resolved
Provide all-around white anchor light.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Accommodation/Occupational Safety
Issued 5 January 1996
Resolved
Label upper deck with maximum capacity of 30 persons in accordance with 46 CFR 185.30-3(e).
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Construction/Loadline
Issued 5 January 1996
Resolved
At next drydock provide proper draft marks and loadlines in accordance with46 CFR 185.30-3.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Construction/Loadline
Issued 14 August 1993
Resolved
RENEW AND/OR REPAIR AS NEEDED THE BOTTOM SHEATHING LOCATED UNDER THE WING BETWEEN BOTH HULLS.
Condition: Unknown
Due 20 October 1993
Resolved 20 October 1993
Construction/Loadline
Issued 14 August 1993
Resolved
RENEW THE DECK LOCATED IN THE FORWARD SPACE OF THE STBD HULL IN WAY OF THE AREA AROUND THE AFT VENT.
Condition: Unknown
Due 3 September 1993
Resolved 8 September 1993
Construction/Loadline
Issued 14 August 1993
Resolved
RENEW THE CRACKED FRAME LOCATED IN THE FORWARD SPACE OF THE STBD HULL (FRAME 7).
Condition: Unknown
Due 3 September 1993
Resolved 8 September 1993
Construction/Loadline
Issued 14 August 1993
Resolved
RENEW THE BALLAST BEDDING (FRAMING) FOR THE FIXED BALLAST LOCATED IN THE FORWARD SPACES IN BOTH HULLS.
Condition: Unknown
Due 3 September 1993
Resolved 8 September 1993
Construction/Loadline
Issued 14 August 1993
Resolved
RENEW ROTTEN SECTIONS OF WOOD FRAMES LOCATED UNDER THE UPPER DECK ON THE AFT END AND ALONG THE SIDES.
Condition: Unknown
Due 3 September 1993
Resolved 23 August 1993
Construction/Loadline
Issued 14 August 1993
Resolved
RENEW THE DECK IN WAY OF THE DRAIN LOCATED IN THE MENS HEAD.
Condition: Unknown
Due 23 August 1993
Resolved 23 August 1993
Lifesaving
Issued 14 August 1993
Resolved
PROVIDE 2 ADDITIONAL PFD'S TO MEET REQUIRED TOTAL OF 137. TOTAL NUMBER OF PERSONS IS LIMITED TO 135 UNTIL THE ADDITIONAL PFD'S ARE PLACED ONBOARD THEVESSEL.
Condition: Unknown
Due 14 August 1993
Resolved 14 August 1993
Construction/Loadline
Issued 14 August 1993
Resolved
RENEW THE DECK LOCATED IN THE FORWARD SPACE ON THE STBD HULL BETWEEN FRAMES3 & 4.
Condition: Unknown
Due 3 September 1993
Resolved 8 September 1993
Lifesaving
Issued 30 November 1992
Resolved
RENEW ONE RING BUOY ON THE MAIN DECK DUE TO DETERIORATION OF THE GRAB LINE.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Documentation
Issued 30 November 1992
Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE RANDOM DRUG TESTING REGULATIONS _x001C_ (46 CFR 16.230). FAILURE TO COMPLY WITH THIS REQUIREMENT WILL _x001C_ RESULT IN REVOCATION OF THE VESSEL'S CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Construction/Loadline
Issued 2 January 1992
Resolved
CROP AND RENEW THREE TERMITE DAMAGED PLANKS IN WAY OF THE FORWARD AND AFTERVENTS IN THE THIRD COMPARTMENT OF THE STARBOARD HULL (GENERATOR ROOM).
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Construction/Loadline
Issued 2 January 1992
Resolved
CROP AND RENEW THE TERMITE DAMAGED AFTER BULKHEAD ON THE UPPER OUTBOARD SIDE OF THE THIRD COMPARTMENT OF THE STARBOARD HULL (GENERATOR ROOM).
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Construction/Loadline
Issued 2 January 1992
Resolved
CROP AND RENEW THREE TERMITE DAMAGED PLANKS IN WAY OF THE FORWARD VENT IN THE FIFTH COMPARTMENT OF THE STARBOARD HULL (PUMP ROOM).
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Construction/Loadline
Issued 2 January 1992
Resolved
CROP AND RENEW THE ROTTEN DECK PLANK IN WAY OF THE AFTER VENT IN THE FIFTH COMPARTMENT OF THE PORT HULL (PUMP ROOM).
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Engineering
Issued 2 December 1991
Resolved
PROVE PROPER OPERATION OF PORT SIDE MAIN FUEL SHUTOFF.
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Engineering
Issued 2 December 1991
Resolved
PROPERLY LABEL MAIN FUEL SHUTOFF VALVES.
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Engineering
Issued 2 December 1991
Resolved
PROPERLY INSTALL FUEL TANK VENT TO MAIN FUEL TANKS AS PER 46 CFR 182.20- 35(A).
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Lifesaving
Issued 2 December 1991
Resolved
PROVIDE NINE ADULT AND FOUR CHILD APPROVED LIFE PRESERVERS. VESSEL RESTRICTED TO NO MORE THAN 130 PERSONS ON BOARD UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Electrical
Issued 21 June 1990
Resolved
REPAIR LIGHT FIXTURE AT ENTRANCE TO PORT PUMPROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
PORTABLE EXTINGUISHER IN PORT GENERATOR ROOM NEEDS SERVICING.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Engineering
Issued 21 June 1990
Resolved
PULL FOUNDATION BOLTS FOR INSPECTION AND RENEWAL OF ROTTEN WOOD, FWD AND AFT BOLTS ON PORT ENGINE ONLY.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
INSTALL LIFELINES ON UPPER DECK.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 15 December 1989
Resolved
RENEW TO GOOD WOOD, DECK (UPPER), PORT, FORWARD OF STANCHION, AT TRANSVERSE/UNDER DECK LONGITUDINAL.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989
Resolved
RENEW PORT OVERHEAD HATCH JUST FORWARD OF GANGWAY.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989
Resolved
RENEW TO GOOD WOOD, STARBOARD GANGWAY OVERHEAD.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989
Resolved
RENEW TO GOOD WOOD OVERHEAD FORWARD OF PORT HATCH AT GANGWAY.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989
Resolved
RENEW AS REQUIRED SPRUCE STRIPPING (HULL, INNER TO WING) PORT AND STARBOARDHULLS.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989
Resolved
EFFECT PERMANENT REPAIRS TO HULL/FRAME/KEEL/RUDDER HORN TIMBER TO THE SAT- ISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989
Resolved
OPEN FOR INSPECTION, TRANSVERSE OVERHEAD (STAGE LIGHTS, FORWARD) AND THREE TRANSVERSES AFT, FROM CENTERLINE TO PORT AND STARBOARD.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989
Resolved
RENEW TO GOOD WOOD, TRANSVERSE; THIRD BAY AFT OF AFTER STAGE LIGHTS CENTER-LINE TO STARBOARD.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 15 December 1989
Resolved
RENEW TO GOOD WOOD: BUTT BLOCK AND PLYWOOD, STARBOARD SIDE, ABEAM GALLEY, #6 TRANSVERSE OVERHEAD.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Construction/Loadline
Issued 13 January 1989
Resolved
RENEW ROTTED PLANKING IN STARBOARD GENERATOR ROOM OVERHEAD.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Construction/Loadline
Issued 13 January 1989
Resolved
RENEW WASTED FRAMING (TERMITE DAMAGE) IN BULKHEAD STARBOARD SIDE BETWEEN HEAD SPACE AND PUMPROOM.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Construction/Loadline
Issued 13 January 1989
Resolved
RENEW WASTED BULKHEAD (TERMITE DAMAGE) STARBOARD SIDE BETWEEN HEAD SPACE AND PUMPROOM.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Engineering
Issued 17 November 1987
Resolved
MAKE CHANGES TO FUEL SUPPLY PIPING ON PORT AND STARBOARD MAIN ENGINE TO COMPLY WITH 46 CFR 182.20-4.
Condition: Unknown
Due 17 November 1987
Resolved 17 November 1987
Unknown
Issued 17 November 1987
Resolved
PROVIDE A SHIP'S BELL AS REQUIRED BY 33 CFR 81.
Condition: Unknown
Due 17 November 1987
Resolved 17 November 1987
Fire Fighting
Issued 17 November 1987
Resolved
FIT FIRE PUMP DISCHARGE WITH A PRESSURE GAUGE AND DEMONSTRATE 60 PSI AS REQUIRED BY 46 CFR 181.10-1.
Condition: Unknown
Due 17 November 1987
Resolved 17 November 1987
Unknown
Issued 1 June 1987
Resolved
MAKE PERMANENT REPAIRS TO THE AREA OF DRY ROT LOCATED IN THE PORT ENGINE AFT OVERHEAD, OUTBOARD SIDE.
Condition: Unknown
Due 1 June 1987
Resolved 1 June 1987
Unknown
Issued 1 June 1987
Resolved
MAKE PERMANENT REPAIRS TO THE AREA OF DRY ROT LOCATED IN THE PORT FUEL ROOM AFT OVERHEAD, OUTBOARD SIDE.
Condition: Unknown
Due 1 June 1987
Resolved 1 June 1987
Unknown
Issued 1 June 1987
Resolved
MAKE PERMANENT REPAIRS TO THE AREA OF DRY ROT LOCATED IN THE STARBOARD FUEL ROOM, AFT OVERHEAD, OUTBOARD SIDE.
Condition: Unknown
Due 1 June 1987
Resolved 1 June 1987
Engineering
Issued 6 December 1985
Resolved
INSULATE BOTH MAIN PROPULSION ENGINE EXHAUST RISERS AT THE DRY STACK LOCATION.
Condition: Unknown
Due 6 December 1985
Resolved 6 December 1985
Unknown
Issued 6 December 1985
Resolved
REPAIR TO ORIGINAL HULL A PATCHED AREA OF BOTTOM PLANKING IN WAY OF THE PORT SHAFT ALLEY.
Condition: Unknown
Due 6 December 1985
Resolved 6 December 1985
Construction/Loadline
Issued 6 December 1985
Resolved
REPLACE ROTTED HULL IN WAY OF STARBOARD GENERATOR SPACE.
Condition: Unknown
Due 6 December 1985
Resolved 6 December 1985
Unknown
Issued 6 December 1985
Resolved
REPLACE ROTTEN HULL SECTION IN WAY OF THE PORT GENERATOR SPACE.
Condition: Unknown
Due 6 December 1985
Resolved 6 December 1985
Electrical
Issued 6 December 1985
Resolved
REPAQIR OR RENEW INOPERATIVE STARBOARD GENERATOR SPACE.
Condition: Unknown
Due 6 December 1985
Resolved 6 December 1985
Documentation
Issued 7 December 1984
Resolved
PROVIDE/POST STABILITY LETTER (ISSUED 11/9/73)
Condition: Unknown
Due 7 December 1984
Resolved 7 December 1984
Fire Fighting
Issued 7 December 1984
Resolved
PROVE OPERATION OF PORTABLE FIRE/BILGE PUMP.
Condition: Unknown
Due 7 December 1984
Resolved 7 December 1984
Accommodation/Occupational Safety
Issued 7 December 1984
Resolved
REROUTE MEN'S FORWARD TOILET DISCHARGE (TYPE III MSD)PUMP OUT LINE. PROVIDE SECURING DEVICES AND LOCK ALL SANITARY OVERBOARD IN THE CLOSED POSITION.
Condition: Unknown
Due 7 December 1984
Resolved 7 December 1984
Accommodation/Occupational Safety
Issued 7 December 1984
Resolved
PROPERLY SECURE LOOSE INBOARD ACCOMMODATION RAIL STARBOARD SIDE IN WAY OF STAGE.
Condition: Unknown
Due 7 December 1984
Resolved 7 December 1984