Records from 1984 to 2018. Most recent: inspection, 12 September 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
12 September 2018
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 6538820
20 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086544
12 December 1994
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 835049
29 July 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1334370
25 July 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1180143
21 May 1993
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1385094
10 May 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1379784
19 June 1992
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 952134
16 June 1992
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1255175
3 May 1991
Re-Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 901267
25 April 1991
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 901265
5 December 1990
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 927806
28 September 1990
Drydock Extension
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 928236
12 July 1990
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1233944
7 June 1990
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 902362
11 May 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 919274
24 April 1989
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1039331
31 March 1989
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 891701
15 November 1988
Drydock Extension
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 893274
1 December 1987
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1310689
28 July 1987
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1331255
24 March 1987
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1327808
23 October 1986
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1321673
28 April 1986
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1304589
28 March 1986
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 998460
20 March 1986
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 992202
12 December 1985
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1292897
7 April 1985
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 994751
7 March 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 979357
28 November 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1285385
Fire Fighting
Issued 16 June 1992
Resolved
Conduct hydrostatic test for B-II dry-chem extinguisher.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Lifesaving
Issued 16 June 1992
Resolved
Renew web lines to floor of 2 life floats.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Construction/Loadline
Issued 16 June 1992
Resolved
Repair reach rod to bilge suction valve for forward peak space.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Documentation
Issued 16 June 1992
Resolved
Provide documentation of enrollment in random drug testing program.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Construction/Loadline
Issued 3 May 1991
Resolved
INSTALL DOGGING BOLTS FOR FWD. SCUTTLE COVERS.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Documentation
Issued 3 May 1991
Resolved
POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Lifesaving
Issued 3 May 1991
Resolved
PROVIDE WATER LIGHTS (2) FOR EACH LIFEFLOAT.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Navigation
Issued 3 May 1991
Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHTS AND COMPLIANCE WITH INT'L COLREGS.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Engineering
Issued 3 May 1991
Resolved
INSTALL REMOTE OPERATION DEVICE FOR DRAINAGE VALVE TO FOREPEAK.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Engineering
Issued 3 May 1991
Resolved
INSTALL RUBBER REINFORCED BILGE PUMP DISCHARGE HOSE IN PLACE OF PLASTIC HOSE.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Accommodation/Occupational Safety
Issued 3 May 1991
Resolved
MAKE REPAIRS TO LEAK IN SANITARY PUMP.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Lifesaving
Issued 11 May 1990
Resolved
REPLACE PAINTERS, AND LINES TO WATER LIGHTS, FOR BOTH LIFE FLOATS.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 11 May 1990
Resolved
REPLACE LIFE LINES ON STARBOARD LIFE FLOAT.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 11 May 1990
Resolved
PROVIDE PADDLES FOR BOTH LIFE FLOATS.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 11 May 1990
Resolved
REPLACE WASTED SUPPORTS FOR LIFE FLOATS.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Fire Fighting
Issued 11 May 1990
Resolved
HYDROSTATICALLY TEST CO2 B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Engineering
Issued 11 May 1990
Resolved
REPAIR FROZEN BILGE VALVE IN ENGINE ROOM.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Navigation
Issued 11 May 1990
Resolved
HAVE COMPASS ADJUSTED AND PROVIDE DEVIATION TABLE ON BOARD.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Navigation
Issued 12 December 1985
Resolved
PROVIDE AND HAVE AVAILABLE FOR TESTING ALL ELECTRICAL NAVIGATIONAL EQUIPMENT.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Lifesaving
Issued 12 December 1985
Resolved
PROVIDE 3 ADULT PFD TO BRING TOTAL TO 52. NUMBER OF TOTAL PEOPLE ALLOWED RESTRICTED TO 49 UNTIL REQUIREMENT IS MET.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Construction/Loadline
Issued 12 December 1985
Resolved
DEWATER STEERING SPACE SO STEERING AND TRANSOM CAN BE EXAMINED.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Lifesaving
Issued 12 December 1985
Resolved
PROVIDE NEW LINES ON 1 BOUYANT APPARATUS AND 1 WATERLIGHT.
Condition: Unknown
Due 12 December 1985
Resolved 12 December 1985
Electrical
Issued 28 November 1984
Resolved
REMOVE UNUSED AND OBSOLETE RUNS OF ELECTRICAL WIRING IN VARIOUS SPACES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Electrical
Issued 28 November 1984
Resolved
REPAIR AND HAVE INTERCOM OPERABLE ON BRIDGE
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Deck/Cargo
Issued 28 November 1984
Resolved
REPAIR ANCHOR LINE AND SUPPLY SUITABLE LENGTH IN PROPER LOCATION.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Lifesaving
Issued 28 November 1984
Resolved
PROVIDE SIX ORANGE FLARES TO BRIDGE OF VESSEL.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Navigation
Issued 28 November 1984
Resolved
REPAIR FORWARD ANCHOR LIGHT ATOP THE PILOT HOUSE.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984