CARNIVAL INSPIRATION is a 1996 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2016, most recently in April 2020, along with 7 deficiencies and 1 operational control.
Records from 2016 to 2020. Most recent: operational control imposed, 7 April 2020.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it63835 - Convention (Subpart B), Gross Ton 39964 - Convention (Subpart B), Net Ton 33626 - Displacement, Metric Ton 6021 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 38
7 April 2020In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6936749
21 February 2020Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6918981
24 January 2020Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6897372
6 January 2020Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6872682
23 November 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6865825
19 November 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6859260
5 November 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6866752
28 October 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6866458
4 October 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6829807
15 July 2019ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6712149
29 June 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732724
28 June 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732620
4 June 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6704475
3 June 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6703736
27 April 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6681480
25 March 2019Deficiency Check · NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6649865
11 February 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6626131
7 January 2019COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6605209
9 July 2018ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6465963
31 January 2018Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6346999
12 January 2018COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6339427
24 October 2017Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6301729
4 September 2017Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6259911
10 July 2017ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6204890
6 June 2017Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6167978
8 May 2017Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6142594
4 April 2017Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6174139
9 January 2017Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6068206
22 November 2016Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6103796
13 September 2016Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6004613
5 August 2016COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5963610
25 July 2016Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5960949
5 July 2016Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5937226
25 June 2016Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5921743
5 May 2016Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5869892
9 March 2016Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5830311
24 February 2016Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5824385
15 February 2016ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5810339
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 January 2020Resolved
The rescue boat embarkation and launching arrangements shall be such that the rescue boat can be boarded and launched in the shortest possible time. The port side rescue boat failed to start during drill. Crew was able to start the rescue boat after approximately 30 minutes.
Action required: 10 - Deficiency Rectified
Due 6 January 2020
Resolved 6 January 2020
Resolution: This deficiency was rectified, to the satisfaction of the attending Port State Control Officer, prior to departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 January 2020Resolved
Each section of sprinklers shall include means for giving a visual and audible alarm signal automatically at one or more indicating units whenever any sprinklers come into operation. PSCOs witnessed section valve 13, on deck 3, failed to alarm upon activation. Vessel's crew adjusted flowmeter and PSCOs witnessed satisfactory operation.
Action required: 10 - Deficiency Rectified
Due 6 January 2020
Resolved 6 January 2020
Resolution: This deficiency was rectified, to the satisfaction of the attending Port State Control Officer, prior to departing the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 March 2019Resolved
Where the emergency source of electrical power is a generator, it shall be: started automatically upon failure of the electrical supply form the main source of electrical power and shall be automatically connected to the switchboard... Vessel's emergency generator is unable to start automatically upon loss of electrical power. 74 SOLAS (97) II-1/42.3.1.2 - 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 April 2019
Construction/Loadline › Penetrations › Gasket
Issued 15 February 2016Resolved
Watertight hatch in ceiling near fire station N-33A has a leaking gasket and does not appear to be watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 9 March 2016
Resolution: Received Class report stating repairs completed
Fire Fighting › Automatic Sprinkler System › Sprinkler Grouping
Issued 15 February 2016Resolved
Section valves 43 and 38 with leaking from the gaskets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 9 March 2016
Resolution: Received Class report stating repairs completed
Construction/Loadline › Structures › Door
Issued 15 February 2016Resolved
Firescreen doors 1205 and 503 did not fully close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Crew repaired firescreen doors to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 15 February 2016Resolved
Heat detector in crew laundry was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Crew replaced heat detector
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National