MAURY USCG vessel records Sign in
← All vessels

ST. ANDREW

ST. ANDREW is a 1996 freight ship. The Coast Guard has recorded 15 inspections since 1996, most recently in April 2006, along with 4 deficiencies and 1 operational control.

Records from 1996 to 2006. Most recent: inspection, 20 April 2006.

Built
1996
Last inspected
20 April 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9088392 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
436502
Flag
LIBERIA
—
Maury page id
psix-436502

Inspections, by type

…with no type recorded11
Years with a record 8 calendar years (1996–2006)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it41499 - Dead Weight, Ton
50849 - Displacement, Ton
14148 - Regulatory (Subpart C or D), Net Ton
25190 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

20 April 2006 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2628517
14 April 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2625212
6 February 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1741037
6 February 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1741059
2 December 2002 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1697255
22 October 2002 Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1694661
21 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1693844
9 July 2002 Annual Inspection · Deficiency Check · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1641389
25 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286329
24 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 52293
22 February 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 275038
13 August 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 431536
11 December 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 423631
6 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 412935
17 May 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 391176

Deficiency record · 4

Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 22 October 2002 Resolved
General housekeeping of machinery and spaces. Remove oil on deck in after steering and decks throughtout engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2002
Resolved 14 April 2006
Resolution: while conducting PII SE the machinery spaces were generally clean of oil on the decks from the steering throughout the engine room.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 22 October 2002 Resolved
Numerous leaks on hydraulic lines that pass through the shaft tunnel forward to machinery. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 28 November 2006
Resolution: Verified class report and cleared 01 deficiencies.
Navigation
Issued 13 August 1999 Resolved
REPAIR/RENEW AS ORIGINAL ARPA/RADAR (X-BAND) FUNCTION. PROVIDE REPAIR REPORTS FROM MAINTENANCE COMPANY TO USCG MSO MOBILE. SOLAS 74(AMENDED) V/12.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Documentation
Issued 13 August 1999 Resolved
HAVE CLASS SOCIETY CORRECT IOPP CERTIFICATE TO SHOW CAPACITY OF BILGE HOLDING TANK. MARPOL 73/78 ANNEX 1.
Condition: Unknown
Due 14 August 1999
Resolved 26 August 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.