13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2025
Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire,
explosion, machinery failure and personnel injury. At the time of inspection, the vessel's Port Engine was found to have an exhaust leak. Operator to rectify within 30 days and prior to carriage of passengers.
46CFR182.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2025
Resolved 8 April 2025
Resolution: Vessel operator provided documentation in the form of photos and technician's servicing report attesting to the repair and satisfactory operation of the vessel's exhaust system. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 June 2024
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame
screens shall consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Fuel vents did not have flame screens on discharge end of piping.
46 CFR 182.20-35 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 8 July 2024
Resolution: Received picture of flame screen fitted on end of vent pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2024
Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Port side engine did not have a machinery guard around the moving belt drives on the forward part of the engine, posing a hazard to personnel working in close proximity. 46 CFR 182.01-5 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 8 July 2024
Resolution: Received picture of machinery guard installed on moving parts of port engine.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 June 2024
Resolved
The water light must be- (i) Of an approved automatic electric type, constructed in accordance with Subpart 161.010 of this chapter, except as allowed under paragraph (d)(2) of this section. Port water light connected to life float would not illuminate as intended.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 8 July 2024
Resolution: Received video of water light operating properly with flashing strobe. Video was unable to be uploaded, but screenshot of strobe working is uploaded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2024
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles onboard were made of plastic material and not noncombustible material. 46 CFR 177.405(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 16 July 2024
Resolution: Received picture from operator verifying non-combustible trash receptacle onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2024
Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structure examinations for certification.
Vessel has lapsed the drydock and internal structure exam expiration dates, 31JAN24, on its COI.
Allow inspection for satisfactory drydock and internal structure exam credit prior to the carriage of passengers.
46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2024
Resolved 6 February 2024
Resolution: Completed vessel's hull/ISE inspections on 06FEB24 with no worklist items noted. Vessel's COI will be amended to reflect credit drydock this date.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 30 May 2023
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket.
Marine Inspector identified three Type I lifejackets two adult and one child with life jacket lights that did not work properly.
Reduce passenger count down to 38 adults and 4 children.
46 CFR 180.75(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 16 June 2023
Resolution: Owner purchased new lifejacket lights and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2023
Resolved
Each ring life buoy must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150
Each ring buoy must have the following information in waterproof lettering: Type IV Personal Flotation Device. Inspected and tested in accordance with U.S. Coast Guard regulations.(Name of buoyant material) buoyant material provides a minimum buoyant force of (32 lb. or 161/2 lb.).Approved for use on recreational boats only as a throwable device. U.S. Coast Guard Approval No. 160.050/(assigned manufacturer's No.)/(Revision No.); (Model No.).(Name and address of manufacturer or distributor).(Size).USCG (Marine Inspection Office identification letters).(Lot No.).
Marine Inspector identified ring buoy with data placard worn not being being able to identify Q specifications approved under.
46 CFR 180.70(b)
46 CFR 160.050
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 16 June 2023
Resolution: Ring Buoy was replaced with a new one.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 May 2023
Resolved
Flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring.
Marine inspector observed 01 cable being utilized as permanent installation on the main deck located portside super structure for permanent lighting.
46 CFR 183.10-20(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 16 June 2023
Resolution: Rewired receptacle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2023
Resolved
Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage.
Marine inspector identified raw water piping for the stbd main diesel engine supply hose and generator supply hoses missing hose clamps. Crew installed hose clamps on both stbd main diesel engine and generator.
46 CFR 182.410(d)(4)
Action required: 10 - Deficiency Rectified
Due 30 May 2023
Resolved 30 May 2023
Resolution: Crew installed hose clamps on both stbd main diesel engine and generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2023
Resolved
Flexible hose must be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid.
Marine Inspector identified supply raw water hose from sea chest valve to the generator strainer that was severely dry rotted and cracked.
46 CFR 182.720(e)(3)(iii)
Action required: 10 - Deficiency Rectified
Due 30 May 2023
Resolved 30 May 2023
Resolution: Crew installed new length of hose, test ran generator with no concerns/issues.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 March 2022
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional tests or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed.
Both port and starboard rudder posts have a steady leak.
46 CFR 176.840
Action required: 10 - Deficiency Rectified
Due 15 March 2022
Resolved 15 March 2022
Resolution: Crewmember tightened the packing nuts on both rudder posts. Both leaks are secured.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 March 2022
Resolved
Each vessel that operates on the high seas must have on board a EPIRB installed to automatically float-free and activate.
EPIRB installed under canopy, rendering it to not be float-free.
46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2022
Resolved 30 March 2022
Resolution: Vsl rep installed EPIRP in a float-free arrangement on top of the house.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 May 2021
Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date charts. Provide charts for the area the vessel operates to include the Gulf of Mexico. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The operator ordered a new chart, chart# 411 Gulf of Mexico, and placed it into service onboard the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2021
Resolved
Accessories, such as switches, fuses, and sockets, shall be standard NEC types for the loads to be carried and shall be of types listed by, or types equal to those listed by UL. Blade automotive fuse found installed as branch circuit overcurrent protection. The fuses installed on this vessel are ATC blade fuses designed for use in 32 volt DC automotive applications, not 12 or 24 V marine applications. Install UL listed cartridge type fuses in place of the automotive blade fuses found onboard. 46 CFR 183.05-35 and
46 CFR 183.380(L)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The opeator replaced the unapproved blade automotive fuses with Bussman ABC fast acting 1/4” x 1 1/4” ceramic fuses (under 15 amps) and a new bussman S-8000 fuse block rated for 30 amps, 300Vac/dc. The installation was found to be satisfactory
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 28 May 2021
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator permit. The operator is responsible for the proper operation of the station IAW 47 CFR 80.155. The master was unfamiliar with the operation of the MF radio. The master must be familiar with the operation of the MF radio and be able to change to a frequency monitored for distress calls. 46 CFR 184.502 and 47 CFR 80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 24 September 2021
Resolution: The owner removed the previous MF radio installation, purchased a new MF radio, and the FCC technician verified its compliance. The master of the vessel was familiar with the MF radio and its functions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2021
Resolved
At each inspection for certification and at every other inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected IAW 46 CFR 176.830. Inspector found the auto pilot installation with three worn mounting bolts and falling off of the steering post it was mounted to. The auto pilot mechanism was found not permanently installed and created a hazardous situation. Install auto pilot permanently to the satisfaction of the attending MI. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The operator replaced the three #10 1 1/4" stainless screws with new stainless #10 1 1/4" screws "in kind."
kind".
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 May 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the [name withheld] identified a longitudinal stringer located port side of centerline in compartment number one originally tabbed into the aft bulkhead using FRP. The FRP tab at the bulkhead was found fractured and the stringer was easily moved by hand. Make satisfactory repairs to the tabbed in stringer to the satisfaction of the attending MI. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The operator repaired the FRP tab using the professional standard Gougeon Brothers fiberglass repair guide. Witnessed 3 layers of 1.5 ounce fiberglass mat tabbed into the existing bulkhead. Repair found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2021
Resolved
Propulsion machinery shall be of suitable type and design for propulsion requirements and capable of operating at constant marine load. Port main engine exhaust manifold found heavily corroded. Replace exhaust manifold piping prior to the cooling water injection, approx 3 feet, in kind. 46 CFR 182.05-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 24 September 2021
Resolution: The owner purchased and installed a new exhaust manifold for the port main engine. Witnessed port main engine in operation; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2021
Resolved
Lighting and power conductors for interior wiring shall be insulated in accordance with Table 183.05-45(c). MI found welding cable installed on main engine starting batteries which does not comply with the insulation requirements for conductors. New installation of conductors must comply with 46 CFR 183.340(d). Install appropriate sized Marine Grade UL listed conductors in place of welding cable. 46 CFR 183.05-45(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The operator replaced the welding cable with a 2 AWG marine grade conductor. The installation was found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 March 2020
Resolved
46 CFR 180.200(a)(2) Each survival craft required on the vessel must remain in good and serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2020
Resolved 4 May 2020
Resolution: Operator repainted degraded life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 May 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
MI observed port side life float net supports to be worn and connected with unapproved line.
Repair in accordance with manufactures instruction or
replace.
IAW: 46CFR176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 31 May 2019
Resolution: New life float installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 May 2019
Resolved
Each life float required on a vessel by this part must meet approval series 160.027 or other standard specified by the Commandant.
MI observed pendants made up in hanks with electrical tape and wire ties.
Replace with light twine or similar material.
IAW: 46 CFR 180.200 (a) (2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 31 May 2019
Resolution: Electrical tape removed and twine used to secure hanks.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Each ring life buoy on a vessel must be readily accessible, be stowed in a way that it can be rapidly cast loose, and not be permanently secured in any way.
MI observed ring life buoy securely fastened to railing
in way of pilot house.
Stow in accordance with regulations as stated above.
IAW: 46 CFR 180.70 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 31 May 2019
Resolution: New life ring bracket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2019
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant.
MI observed wasted retroreflective material on ring life buoy.
Provide and replace in accordance with regulations.
IAW:46 CFR 185.604 (i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner replaced retro reflective tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2019
Resolved
Where flexibility is necessary, a section of flexible metallic hose may be used. Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or
or panting, and is double clamped where practicable.
MI observed a loose wasted hose clamp on the starboard
wet exhaust system.
Provide and replace in accordance with regulations.
IAW:46 CFR 182.430 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner replaced hose clamp on engine exhaust.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 May 2019
Resolved
Each hatch exposed to the weather must be watertight.
MI observed wasted gasket on fore peak hatch cover.
Repair in accordance with manufacturer's instruction.
IAW: 46 CFR 171.124 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner replaced with new gasket.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 May 2019
Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595, or shall bear the proper Underwriters, Laboratories, Inc. "Marine Type" label, or shall be constructed in accordance with the requirements of other recognized testing laboratories.
MI observed missing light cover in the forward starboard side of engine compartment.
Replace in accordance with manufacturer's instruction.
IAW: 46 CFR 183.10-20 (k)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner installed new lens cover for light fixture.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2019
Resolved
All electrical installations shall be to the satisfaction of the officer in Charge, Marine Inspection.
No more than four conductors shall be secured to any one terminal stud. If additional connections are necessary, two or more terminal studs shall be connected together by means of jumpers or copper straps.
MI observed 8 conductors connected to each terminal on a battery located starboard side of engine compartment.
Reduce the number of conductors on each terminal.
IAW:46 CFR 183.01-15 (a), ABYC E-9.16 (k.10)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner removed excess cables from battery terminal.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2019
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
MI observed that EPIRB test was not being logged.
Start logging EPIRB test.
IAW: 46 CFR 185.728 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner logged EPIRB tests.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 May 2019
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information.
(1) Date of the training; and
(2) General description of the training topics.
MI observed that drills were not being logged.
Start logging drills.
IAW: 46 CFR 185.420(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner provided proof of crew training logs.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 January 2018
Resolved
Provide repair proposal for upper outboard support frame for MSD tank portside.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 29 January 2018
Resolution: Provide acceptable repair proposal
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 January 2018
Resolved
Remove fiberglass layer in overhead frame to good wood, in fwd engineroom stb side and make ready for inspection by a marine inspector.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 29 January 2018
Resolution: Satisfactory inspection and repair
Lifesaving › Lifefloat › Float-free Link
Issued 14 February 2017
Resolved
Provide proper weak link and configuration for both life floats iaw 46CFR180.137(b). Prior to completion of item, vessel may operate on waters less than 100 ft deep on 15FEB17.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2017
Resolved 21 February 2017
Resolution: Weak link and configuration was satisfactory.
Lifesaving › Lifefloat › Netting
Issued 14 February 2017
Resolved
Replace 01 strap and tighten 02 straps on port side life float iaw 46CFR180.10-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: New lines on the life float were installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 February 2017
Resolved
Provide 02 personal flotation devices iaw 46CFR180.71(a). Passenger count reduced to 38.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 14 February 2017
Resolution: Vessel provided 02 new life jackets prior to the departure of the attending marine inspectors.
Navigation › Piloting/Steering › Marine Charts
Issued 14 February 2017
Resolved
Provide updted charts and nautical publications iaw 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Resolution: A new 2017 chart was onboard and publications were updated.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 February 2017
Resolved
Repair/Replace breaker for galley systems iaw 46CFR176.806(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: The breaker for the galley was reconfigured and renewed.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 February 2017
Resolved
Install longer cables for battery charger and fresh water pump to reach outlet iaw 46CFR176.806(a).
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Resolution: The battery charger was moved and new terminal box installed for fresh water pump.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 February 2017
Resolved
Install generator fuel shutoff label iaw 46CFR185.30-20.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: Fuel shut off was labeled.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 February 2017
Resolved
Prove input of MMSI and LAT/LONG (GPS) in VHF-FM radio iaw 47CFR80.103.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Resolution: MMSI and Lat/Lon were within the VHF radio.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 February 2017
Resolved
Provide proper repair of port side fuel shutoff valve iaw 46CFR182.15(b)(3).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2017
Resolved 14 February 2017
Resolution: Vessel replaced/repaired valve prior to the departure of attending marine inspectors.
Documentation › Certificates/Documents › Stability Letter
Issued 3 August 2016
Resolved
Prove that the vessel has a current stability letter. If no there is no current stability letter, the vessel must preform a SST or meet 46CFR 170-171. Vessel is restricted to carrying no more than 19 passengers (+5 crew) for a total of 24 persons. If in operation,the aft canopy and upper deck canopy must be removed with the exception of the frame. 46CFR 178.210 & 46CFR 178.330
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 9 August 2016
Resolution: Completed and passed a SST.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2016
Resolved
All wires shall be secured every 24". 46CFR183.10-15
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 22 August 2016
Resolution: All wires appear to be properly terminated and supported.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 July 2016
Resolved
New COI and stability letter shall be posted. 46CFR 176.01-35
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 22 August 2016
Resolution: Current documents posted and new documents will be posted once delivered.