MAURY USCG vessel records Sign in
← All vessels

YANKEE STAR

YANKEE STAR is a 1996 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1996, most recently in February 2026, along with 71 deficiencies, 1 operational control and 3 casualty investigations between 2007 and 2013.

Records from 1996 to 2026. Most recent: inspection, 26 February 2026.

Built
1996
Last inspected
26 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2778
436622
Flag
UNITED STATES
367119790 (licence lapsed)
Maury page id
psix-436622

Inspections, by type

…with no type recorded5
Years with a record 25 calendar years (1996–2026)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 19.0 ft × 8.0 ft
Registered tonnagegross 66 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS · ELMORE, AL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 9 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI8685MMSI 367119790 · expired · compulsorily equipped · granted 16 June 2016, cancelled 25 July 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDD2778MMSI 367119790 · terminated · compulsorily equipped · granted 7 June 2006, cancelled 15 June 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 48

26 February 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8312585
21 March 2025 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8091941
11 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7906029
31 January 2024 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7857945
14 September 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7791396
30 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7684777
15 March 2022 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7403887
31 January 2022 Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7383615
24 September 2021 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7319785
28 May 2021 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7200283
23 March 2020 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6928266
3 February 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6901841
17 September 2019 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6814821
13 May 2019 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6667733
8 May 2018 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6393081
24 January 2018 Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6333121
27 January 2017 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6078599
3 August 2016 Simplified Stability Test · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5961863
1 July 2016 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5921125
16 February 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5815923
9 July 2012 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4372884
7 May 2012 Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4304878
7 May 2009 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3472100
3 March 2009 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3428011
1 July 2008 Hull Examination · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3254353
22 June 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3248753
16 May 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3206865
7 November 2007 Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 3095093
13 October 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3094694
10 May 2007 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2926928
2 April 2007 Simplified Stability Test · Plan Review "T" Boat
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2897500
19 July 2006 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2718203
2 June 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2667060
8 March 2006 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2618412
14 April 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2372903
24 March 2004 Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2030286
8 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1789009
11 July 2002 Type not recorded
No type recorded · USCGC STURGEON (WPB 87336) · USCG Northeast District (CGD-NE) · Activity 1647189
9 April 2002 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1602744
17 April 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467281
24 February 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440254
27 January 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397338
17 November 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437480
19 October 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402725
19 November 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416596
25 February 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099796
22 November 1996 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1398576
18 November 1996 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380695

Deficiency record · 71

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2025 Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. At the time of inspection, the vessel's Port Engine was found to have an exhaust leak. Operator to rectify within 30 days and prior to carriage of passengers. 46CFR182.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2025
Resolved 8 April 2025
Resolution: Vessel operator provided documentation in the form of photos and technician's servicing report attesting to the repair and satisfactory operation of the vessel's exhaust system. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 June 2024 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Fuel vents did not have flame screens on discharge end of piping. 46 CFR 182.20-35 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 8 July 2024
Resolution: Received picture of flame screen fitted on end of vent pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2024 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Port side engine did not have a machinery guard around the moving belt drives on the forward part of the engine, posing a hazard to personnel working in close proximity. 46 CFR 182.01-5 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 8 July 2024
Resolution: Received picture of machinery guard installed on moving parts of port engine.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 June 2024 Resolved
The water light must be- (i) Of an approved automatic electric type, constructed in accordance with Subpart 161.010 of this chapter, except as allowed under paragraph (d)(2) of this section. Port water light connected to life float would not illuminate as intended.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 8 July 2024
Resolution: Received video of water light operating properly with flashing strobe. Video was unable to be uploaded, but screenshot of strobe working is uploaded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2024 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles onboard were made of plastic material and not noncombustible material. 46 CFR 177.405(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 16 July 2024
Resolution: Received picture from operator verifying non-combustible trash receptacle onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2024 Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structure examinations for certification. Vessel has lapsed the drydock and internal structure exam expiration dates, 31JAN24, on its COI. Allow inspection for satisfactory drydock and internal structure exam credit prior to the carriage of passengers. 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2024
Resolved 6 February 2024
Resolution: Completed vessel's hull/ISE inspections on 06FEB24 with no worklist items noted. Vessel's COI will be amended to reflect credit drydock this date.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 30 May 2023 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Marine Inspector identified three Type I lifejackets two adult and one child with life jacket lights that did not work properly. Reduce passenger count down to 38 adults and 4 children. 46 CFR 180.75(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 16 June 2023
Resolution: Owner purchased new lifejacket lights and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2023 Resolved
Each ring life buoy must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150 Each ring buoy must have the following information in waterproof lettering: Type IV Personal Flotation Device. Inspected and tested in accordance with U.S. Coast Guard regulations.(Name of buoyant material) buoyant material provides a minimum buoyant force of (32 lb. or 161/2 lb.).Approved for use on recreational boats only as a throwable device. U.S. Coast Guard Approval No. 160.050/(assigned manufacturer's No.)/(Revision No.); (Model No.).(Name and address of manufacturer or distributor).(Size).USCG (Marine Inspection Office identification letters).(Lot No.). Marine Inspector identified ring buoy with data placard worn not being being able to identify Q specifications approved under. 46 CFR 180.70(b) 46 CFR 160.050
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 16 June 2023
Resolution: Ring Buoy was replaced with a new one.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 May 2023 Resolved
Flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring. Marine inspector observed 01 cable being utilized as permanent installation on the main deck located portside super structure for permanent lighting. 46 CFR 183.10-20(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 16 June 2023
Resolution: Rewired receptacle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2023 Resolved
Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage. Marine inspector identified raw water piping for the stbd main diesel engine supply hose and generator supply hoses missing hose clamps. Crew installed hose clamps on both stbd main diesel engine and generator. 46 CFR 182.410(d)(4)
Action required: 10 - Deficiency Rectified
Due 30 May 2023
Resolved 30 May 2023
Resolution: Crew installed hose clamps on both stbd main diesel engine and generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2023 Resolved
Flexible hose must be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. Marine Inspector identified supply raw water hose from sea chest valve to the generator strainer that was severely dry rotted and cracked. 46 CFR 182.720(e)(3)(iii)
Action required: 10 - Deficiency Rectified
Due 30 May 2023
Resolved 30 May 2023
Resolution: Crew installed new length of hose, test ran generator with no concerns/issues.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 March 2022 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional tests or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Both port and starboard rudder posts have a steady leak. 46 CFR 176.840
Action required: 10 - Deficiency Rectified
Due 15 March 2022
Resolved 15 March 2022
Resolution: Crewmember tightened the packing nuts on both rudder posts. Both leaks are secured.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 March 2022 Resolved
Each vessel that operates on the high seas must have on board a EPIRB installed to automatically float-free and activate. EPIRB installed under canopy, rendering it to not be float-free. 46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2022
Resolved 30 March 2022
Resolution: Vsl rep installed EPIRP in a float-free arrangement on top of the house.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 May 2021 Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date charts. Provide charts for the area the vessel operates to include the Gulf of Mexico. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The operator ordered a new chart, chart# 411 Gulf of Mexico, and placed it into service onboard the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2021 Resolved
Accessories, such as switches, fuses, and sockets, shall be standard NEC types for the loads to be carried and shall be of types listed by, or types equal to those listed by UL. Blade automotive fuse found installed as branch circuit overcurrent protection. The fuses installed on this vessel are ATC blade fuses designed for use in 32 volt DC automotive applications, not 12 or 24 V marine applications. Install UL listed cartridge type fuses in place of the automotive blade fuses found onboard. 46 CFR 183.05-35 and 46 CFR 183.380(L)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The opeator replaced the unapproved blade automotive fuses with Bussman ABC fast acting 1/4” x 1 1/4” ceramic fuses (under 15 amps) and a new bussman S-8000 fuse block rated for 30 amps, 300Vac/dc. The installation was found to be satisfactory
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 28 May 2021 Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator permit. The operator is responsible for the proper operation of the station IAW 47 CFR 80.155. The master was unfamiliar with the operation of the MF radio. The master must be familiar with the operation of the MF radio and be able to change to a frequency monitored for distress calls. 46 CFR 184.502 and 47 CFR 80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 24 September 2021
Resolution: The owner removed the previous MF radio installation, purchased a new MF radio, and the FCC technician verified its compliance. The master of the vessel was familiar with the MF radio and its functions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2021 Resolved
At each inspection for certification and at every other inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected IAW 46 CFR 176.830. Inspector found the auto pilot installation with three worn mounting bolts and falling off of the steering post it was mounted to. The auto pilot mechanism was found not permanently installed and created a hazardous situation. Install auto pilot permanently to the satisfaction of the attending MI. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The operator replaced the three #10 1 1/4" stainless screws with new stainless #10 1 1/4" screws "in kind." kind".
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 May 2021 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the [name withheld] identified a longitudinal stringer located port side of centerline in compartment number one originally tabbed into the aft bulkhead using FRP. The FRP tab at the bulkhead was found fractured and the stringer was easily moved by hand. Make satisfactory repairs to the tabbed in stringer to the satisfaction of the attending MI. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The operator repaired the FRP tab using the professional standard Gougeon Brothers fiberglass repair guide. Witnessed 3 layers of 1.5 ounce fiberglass mat tabbed into the existing bulkhead. Repair found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2021 Resolved
Propulsion machinery shall be of suitable type and design for propulsion requirements and capable of operating at constant marine load. Port main engine exhaust manifold found heavily corroded. Replace exhaust manifold piping prior to the cooling water injection, approx 3 feet, in kind. 46 CFR 182.05-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 24 September 2021
Resolution: The owner purchased and installed a new exhaust manifold for the port main engine. Witnessed port main engine in operation; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2021 Resolved
Lighting and power conductors for interior wiring shall be insulated in accordance with Table 183.05-45(c). MI found welding cable installed on main engine starting batteries which does not comply with the insulation requirements for conductors. New installation of conductors must comply with 46 CFR 183.340(d). Install appropriate sized Marine Grade UL listed conductors in place of welding cable. 46 CFR 183.05-45(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 18 June 2021
Resolution: The operator replaced the welding cable with a 2 AWG marine grade conductor. The installation was found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 March 2020 Resolved
46 CFR 180.200(a)(2) Each survival craft required on the vessel must remain in good and serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2020
Resolved 4 May 2020
Resolution: Operator repainted degraded life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 May 2019 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed port side life float net supports to be worn and connected with unapproved line. Repair in accordance with manufactures instruction or replace. IAW: 46CFR176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 31 May 2019
Resolution: New life float installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 May 2019 Resolved
Each life float required on a vessel by this part must meet approval series 160.027 or other standard specified by the Commandant. MI observed pendants made up in hanks with electrical tape and wire ties. Replace with light twine or similar material. IAW: 46 CFR 180.200 (a) (2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 31 May 2019
Resolution: Electrical tape removed and twine used to secure hanks.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019 Resolved
Each ring life buoy on a vessel must be readily accessible, be stowed in a way that it can be rapidly cast loose, and not be permanently secured in any way. MI observed ring life buoy securely fastened to railing in way of pilot house. Stow in accordance with regulations as stated above. IAW: 46 CFR 180.70 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 31 May 2019
Resolution: New life ring bracket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2019 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. MI observed wasted retroreflective material on ring life buoy. Provide and replace in accordance with regulations. IAW:46 CFR 185.604 (i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner replaced retro reflective tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2019 Resolved
Where flexibility is necessary, a section of flexible metallic hose may be used. Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or or panting, and is double clamped where practicable. MI observed a loose wasted hose clamp on the starboard wet exhaust system. Provide and replace in accordance with regulations. IAW:46 CFR 182.430 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner replaced hose clamp on engine exhaust.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 May 2019 Resolved
Each hatch exposed to the weather must be watertight. MI observed wasted gasket on fore peak hatch cover. Repair in accordance with manufacturer's instruction. IAW: 46 CFR 171.124 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner replaced with new gasket.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 May 2019 Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595, or shall bear the proper Underwriters, Laboratories, Inc. "Marine Type" label, or shall be constructed in accordance with the requirements of other recognized testing laboratories. MI observed missing light cover in the forward starboard side of engine compartment. Replace in accordance with manufacturer's instruction. IAW: 46 CFR 183.10-20 (k)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner installed new lens cover for light fixture.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2019 Resolved
All electrical installations shall be to the satisfaction of the officer in Charge, Marine Inspection. No more than four conductors shall be secured to any one terminal stud. If additional connections are necessary, two or more terminal studs shall be connected together by means of jumpers or copper straps. MI observed 8 conductors connected to each terminal on a battery located starboard side of engine compartment. Reduce the number of conductors on each terminal. IAW:46 CFR 183.01-15 (a), ABYC E-9.16 (k.10)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner removed excess cables from battery terminal.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2019 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. MI observed that EPIRB test was not being logged. Start logging EPIRB test. IAW: 46 CFR 185.728 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner logged EPIRB tests.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 May 2019 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. MI observed that drills were not being logged. Start logging drills. IAW: 46 CFR 185.420(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Owner provided proof of crew training logs.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 January 2018 Resolved
Provide repair proposal for upper outboard support frame for MSD tank portside.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 29 January 2018
Resolution: Provide acceptable repair proposal
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 January 2018 Resolved
Remove fiberglass layer in overhead frame to good wood, in fwd engineroom stb side and make ready for inspection by a marine inspector.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 29 January 2018
Resolution: Satisfactory inspection and repair
Lifesaving › Lifefloat › Float-free Link
Issued 14 February 2017 Resolved
Provide proper weak link and configuration for both life floats iaw 46CFR180.137(b). Prior to completion of item, vessel may operate on waters less than 100 ft deep on 15FEB17.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2017
Resolved 21 February 2017
Resolution: Weak link and configuration was satisfactory.
Lifesaving › Lifefloat › Netting
Issued 14 February 2017 Resolved
Replace 01 strap and tighten 02 straps on port side life float iaw 46CFR180.10-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: New lines on the life float were installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 February 2017 Resolved
Provide 02 personal flotation devices iaw 46CFR180.71(a). Passenger count reduced to 38.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 14 February 2017
Resolution: Vessel provided 02 new life jackets prior to the departure of the attending marine inspectors.
Navigation › Piloting/Steering › Marine Charts
Issued 14 February 2017 Resolved
Provide updted charts and nautical publications iaw 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Resolution: A new 2017 chart was onboard and publications were updated.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 February 2017 Resolved
Repair/Replace breaker for galley systems iaw 46CFR176.806(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: The breaker for the galley was reconfigured and renewed.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 February 2017 Resolved
Install longer cables for battery charger and fresh water pump to reach outlet iaw 46CFR176.806(a).
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Resolution: The battery charger was moved and new terminal box installed for fresh water pump.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 February 2017 Resolved
Install generator fuel shutoff label iaw 46CFR185.30-20.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: Fuel shut off was labeled.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 February 2017 Resolved
Prove input of MMSI and LAT/LONG (GPS) in VHF-FM radio iaw 47CFR80.103.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Resolution: MMSI and Lat/Lon were within the VHF radio.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 February 2017 Resolved
Provide proper repair of port side fuel shutoff valve iaw 46CFR182.15(b)(3).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2017
Resolved 14 February 2017
Resolution: Vessel replaced/repaired valve prior to the departure of attending marine inspectors.
Documentation › Certificates/Documents › Stability Letter
Issued 3 August 2016 Resolved
Prove that the vessel has a current stability letter. If no there is no current stability letter, the vessel must preform a SST or meet 46CFR 170-171. Vessel is restricted to carrying no more than 19 passengers (+5 crew) for a total of 24 persons. If in operation,the aft canopy and upper deck canopy must be removed with the exception of the frame. 46CFR 178.210 & 46CFR 178.330
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 9 August 2016
Resolution: Completed and passed a SST.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2016 Resolved
All wires shall be secured every 24". 46CFR183.10-15
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 22 August 2016
Resolution: All wires appear to be properly terminated and supported.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 July 2016 Resolved
New COI and stability letter shall be posted. 46CFR 176.01-35
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 22 August 2016
Resolution: Current documents posted and new documents will be posted once delivered.
Documentation › Certificates/Documents › FCC SSL
Issued 2 June 2006 Resolved
Provide a FCC Safety Certificate and FCC Station License for vessel. POC has sent in the application for the license/cert because of the new name and O/O change. FCC inspector said it should be done early next week.
Condition: Improper/Lack of Maintenance
Due 9 June 2006
Resolved 9 June 2006
Resolution: RCVD A COPY OF ALL CERTIFICATES.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 June 2006 Resolved
Replace all cracked windows as discussed. Most windows in the passenger area area cracked. O/O planned on replacing them, but needed 30 days to get material.
Condition: Improper/Lack of Maintenance
Due 2 August 2006
Resolved 15 May 2007
Resolution: O/O renewed ALL windows in the passenger area.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 June 2006 Resolved
Replace retro-reflective material on life preservers as needed. O/O was going to clean and repair jackets prior to stowage.
Condition: Improper/Lack of Maintenance
Due 9 June 2006
Resolved 9 June 2006
Resolution: RCVD A COPY OF RECEIPT FOR TAPE.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 June 2006 Resolved
Prior to the carriage of passengers, repair high blige level alarm in after steering void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2006
Resolved 9 June 2006
Resolution: RCVD AN E-MAIL FROM O/O ATTESTING REPAIRS.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 2 June 2006 Resolved
Prior to the carriage of passengers, provide emergency lighting IAW 46CFR183.432. They only have manual operated emergency lighting for the FWD berthing areas. Discussed regulations and O/O will correct.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2006
Resolved 9 June 2006
Resolution: RCVD AN E-MAIL FROM O/O ATTESTING TO THE REPAIR. INSTALLED A RELAY SO LIGHTS WILL COME ON WHEN POWERE IS LOST.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 2 June 2006 Resolved
Prior to the carriage of passengers, provide 02 independent mudular smoke detection units for the FWD berthing areas IAW 46CFR181.450 (UL Standard 217) They have no means to detect smoke in the FWD berthing areas.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2006
Resolved 9 June 2006
Resolution: RCVD A COPY OF RECEIPT AND DATA SHEET FOR DETECTOR.
Communications › Radio Communications › EPIRB
Issued 2 June 2006 Resolved
Prior to the carriage of passengers, provide EPIRB registration for vessel. Paper work has been submitted for name change.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2006
Resolved 9 June 2006
Resolution: RCVD A COPY OF REGISTRATION.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 14 April 2005 Resolved
Condition: Improper/Lack of Maintenance
Due 14 May 2005
Resolved 1 May 2005
Resolution: Hand Rail repaired.
Accommodation/Occupational Safety › Potable Water System › General
Issued 14 April 2005 Resolved
Renew or Remove existing potable hot water heater.
Condition: Improper/Lack of Maintenance
Due 14 May 2005
Resolved 1 May 2005
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 14 April 2005 Resolved
Show proper operation of Generator Oil Pressure Gauge.
Due 14 May 2005
Resolved 1 May 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 April 2005 Resolved
Remove installed wing nuts from battery terminals and install hexagon nuts.
Condition: Improper Installation
Due 14 May 2005
Resolved 1 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 14 April 2005 Resolved
Renew gauge line on Stbd Main Engine Clutch Assembly.
Condition: Improper/Lack of Maintenance
Due 14 May 2005
Resolved 1 May 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 14 April 2005 Resolved
Demonstrate proper operation of both VHF radios.
Condition: Unknown
Due 14 May 2005
Resolved 1 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 April 2005 Resolved
Renew retroreflective material on ten (10) PFD's.
Condition: Improper/Lack of Maintenance
Due 14 May 2005
Resolved 1 May 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 10 April 2002 Resolved
NO FLAME SCREEN ON FUEL TANK VENT.
Due 10 April 2002
Resolved 10 April 2002
Documentation › Manuals/Policy Documentation
Issued 10 April 2002 Resolved
MISSING 1 COMPLETE SET OF REQUIRED NAV PUBS. LEGACY COMPONENT DESC: NAV PUBS
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Lifesaving
Issued 10 April 2002 Resolved
EPIRB HAS EXPIRED BATTERY. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 10 April 2002 Resolved
NO ANNUAL SERVICE CONDUCTED FOR ALL PORTABLE FIRE EXTINGUISHERS. LEGACY COMPONENT DESC: Service
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 10 April 2002 Resolved
2 CONDUCTOR WIRE ON STARBOARD BATTERY BROKEN.
Due 10 April 2002
Resolved 10 April 2002
Navigation › Collision/Grounding Avoidance
Issued 10 April 2002 Resolved
NAVIGATION LIGHTS INOPERABLE. LEGACY COMPONENT DESC: Navigation Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Pollution Prevention/Response
Issued 9 April 2002 Resolved
SEWAGE VALVE NOT LOCKED. LEGACY COMPONENT DESC: SEWAGE VALVE
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002
Resolved 10 April 2002
Lifesaving
Issued 22 November 1996 Resolved
PROVIDE AND POST ON BOARD VESSEL REQUIRED EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH 46 CFR 185.510 AND 185.512.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Lifesaving
Issued 22 November 1996 Resolved
CONDUCT SATISFACTORY MAN OVERBOARD, ABANDON SHIP AND FIRE DRILLS IN THE PRESENCE OF A COAST GUARD INSPECTOR IN ACCORDANCE WITH 46 CFR 185.520; 185.524; AND NVIC 1-91.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Unknown
Issued 22 November 1996 Resolved
PRESENT VESSEL TO COGNIZANT OCMI FOR INSPECTION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 December 1996
Resolved 1 February 1997
Accommodation/Occupational Safety
Issued 22 November 1996 Resolved
PROVIDE A MEANS TO DETERMINE WHEN THE MSD TANK IS 3/4 FULL BY VOLUME IAW 33CFR 159.83.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Lifesaving
Issued 22 November 1996 Resolved
PROVIDE AND POST LIFEJACKET DONNING PLACARD FOR SPECIFIC TYPE OF LIFE PRESERVER CARRIED ONBOARD VESSEL IN ACCORDANCE WITH 46 CFR 185.516.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996

Casualty record · 3

13 October 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3094694
22 June 2008Routine · role: Involved in a Marine Casualty · activity 3248753
1 September 2013Routine · role: Involved in a Marine Casualty · 3 injured · activity 4711280
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GULF STAR (2007–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.