Records from 2016 to 2020. Most recent: inspection, 28 July 2020.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 September 2019
Resolved
Conudct Annual Inspection prior to carriage of passengers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 22 December 2020
Resolution: Deactivated COI and cleared requirement.
Electrical › Electric Supply System (service) › Battery Charger
Issued 23 April 2018
Resolved
Reinstall charging circuit as original
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 26 April 2018
Resolution: MI attended cleared outstanding
Electrical › Electric Supply System (service) › Cable
Issued 23 April 2018
Resolved
Properly secure electrical start circuit
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 26 April 2018
Resolution: MI attended cleared outstanding def
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 23 April 2018
Resolved
Properly install ground circuit for fuel tanks
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 26 April 2018
Resolution: MI attended cleared outstanding
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 31 October 2017
Resolved
VIKING FLEET failed to make immediate notification of the marine casualty as required by
46 CFR 5.05-1(a)
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: To the satisfaction of the Coast Gaurd.
Lifesaving › Lifebuoys › Serviceable
Issued 24 May 2017
Resolved
Provide new Ring Life Buoy. Current RLB is unserviceable. 46CFR180.70
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 30 May 2017
Resolution: Provided new RLB. with retro and labeled.
Construction/Loadline › Hull › Keel
Issued 10 November 2016
Resolved
Remove and replace 02 bolts at stem,keel, knee joint.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 November 2016
Resolution: Operator installed two (02) 20 inch long threaded bolts, washers and nuts through all lap joints on the stem, knee, keel temporary repair.
Construction/Loadline › Hull › Transverse Frame
Issued 10 November 2016
Resolved
Remove and replace 02 small transverse deck frames, sister 01 frame and add stanchion to starboard deck longitudinal in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 December 2016
Resolution: New transverse deck frames installed, stanchion added to starboard side longitudinal deck stringer, and deck boards replaced.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 November 2016
Resolved
Drain engine room bilge of oily water for keel bolt inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 November 2016
Resolution: Oil in engine room bilge removed and cleaned for inspection of keel bolts.
Engineering › Steering Gear System › Rudder Stock
Issued 27 May 2016
Resolved
Make repair to port rudder leak on the forward edge of support board.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2016
Resolution: Port side rudder support board nuts were tightened ceasing water from leaking into lazarette.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 May 2016
Resolved
Remove dead end wiring in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 27 May 2016
Resolution: Dead end wires were remove from vessel's engine room.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 May 2016
Resolved
Remove wing nuts from battery terminals.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 27 May 2016
Resolution: Wing nuts were removed and replaced with new hex head nuts on all battery terminals.
Construction/Loadline › Hull › Girder
Issued 20 May 2016
Resolved
Fasten stanchions in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 27 May 2016
Resolution: Stanchions were fastened into the floor timbers.
Engineering › Steering Gear System › Rudder Stock
Issued 20 May 2016
Resolved
Observe port side rudder for leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 27 May 2016
Resolution: Observed port side rudder leaking on the forward edge of the rudder stock support board with underway. New requirement to fix was written.
Construction/Loadline › Hull › Transverse Frame
Issued 6 May 2016
Resolved
Repair two (02) cracked frames on starboard side crash compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: (02) frames were sistered.
Engineering › Bilge Water Management System › Strainer
Issued 6 May 2016
Resolved
Install bilge suction strainer in crash compartment.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: New bilge suction strainer installed.
Engineering › Bilge Water Management System › Valve
Issued 6 May 2016
Resolved
Install deck access for crash compartment reach rod valve.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: Deck access for crash compartment reach rod installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 May 2016
Resolved
Make watertight bulkheads forward and aft of the engine room watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: Bulkhead penetrations filled and made watertight.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 May 2016
Resolved
Clean engine room and #2 compartment bilges of excess oil for reinspection.
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: Excess oil and trash was removed from bilges in engine room and #2 compartment.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 May 2016
Resolved
Repair port side rails amidships.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: Railings were repaired with wooden wedges and epoxy they were able to withstand point loads.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 6 May 2016
Resolved
Make starboard propeller ready for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: Starboard propeller was properly reinstalled and in new condition.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2016
Resolved
Remove wire nut from lazeratte bilge pump wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: Wire nut removed and replaced with permanent crimp splice.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 May 2016
Resolved
Remove and replace two (02) 2" inch valves in compartment #2. Valves were seized.
Action required: 705 - Other - as specified
Resolved 20 May 2016
Resolution: Valves were replaced with new 2" valves.
Construction/Loadline › Hull › Keel
Issued 6 May 2016
Resolved
Provide repair proposal for wood rot damage located at the stem forefoot joint.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2016
Resolution: Operator sumbitted repair proposal as requested.
Construction/Loadline › Hull › Side Shell
Issued 8 April 2016
Resolved
One year dry dock from tody's date to remove port side garboard plank at the stem, and port side and starboard side covering boards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 10 November 2016
Resolution: Port side garboard plank was found to terminate between frames and fastened to butt block. Plank was replaced in 2014 according to MISLE history. Observed underside of covering boards and observed no wood degredation in immediate vicinity.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 April 2016
Resolved
Service CO2 system to include hydro test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2016
Resolution: Operator provided paperwork proving hydro date for bottles conducted on 6-14. Bottles were raised 10 degrees to be within allowable limits for bottles with bent siphons. They may be inclined up to 80 degress from vertical