← All vessels
SEA PIRATE
Commercial Fishing Vessel · Fishing Vessel class · Built 1950s · USCG Northwest District (CGD-NW) · Other hulls named SEA PIRATE
SEA PIRATE is a 1959 commercial fishing vessel. The Coast Guard has recorded 56 inspections since 1986, most recently in May 2012, along with 81 deficiencies and 1 casualty investigation in 2012.
Records from 1986 to 2012. Most recent: casualty investigation, 23 September 2012.
- Built
- 1959
- Last inspected
- 5 May 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 81 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2012
Identity
278785
WAM5043
43684
Flag
UNITED STATES
367047060 (licence lapsed)
Maury page id
psix-43684
Inspections, by type
…with no type recorded4
Years with a record
25 calendar years (1986–2012)
The 56 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it12 - Regulatory (Subpart C or D), Net Ton
17 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WAM5043MMSI 367047060 · expired · compulsorily equipped · granted 3 June 2005, cancelled 8 August 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 56
5 May 2012
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4284494
20 July 2009
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3540929
25 June 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3249794
6 May 2008
Deficiency Check · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3164778
19 April 2007
COI Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2917048
5 June 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2681760
10 May 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2644998
27 April 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2642943
14 March 2006
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2576261
26 April 2005
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2345121
29 March 2005
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2319041
8 April 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2040406
19 February 2004
Annual Inspection · Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2000376
16 April 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1947338
20 April 2002
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1625904
5 April 2002
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1601208
2 May 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1070610
5 April 2001
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1422052
5 January 2001
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1448210
19 April 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1049215
3 April 2000
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1404942
11 May 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 795821
22 April 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1406482
24 November 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 806970
8 July 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1129157
9 April 1998
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1383849
13 February 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 776126
21 April 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1101740
31 March 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1106999
6 March 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1402402
12 December 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1092725
10 December 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1093138
9 October 1996
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414701
22 July 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1090414
3 June 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1182617
22 April 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1363586
17 February 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 100332
12 April 1995
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1402019
6 May 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2098
20 April 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1168173
5 April 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1462385
27 April 1993
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1376975
4 December 1992
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 832368
7 November 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 169286
15 July 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1254582
15 June 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 962976
11 May 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1263064
9 May 1991
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 930236
10 May 1990
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 916190
10 May 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1214559
24 January 1989
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1348862
8 December 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1032556
3 February 1988
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1019294
7 May 1987
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1334008
11 June 1986
Credit Drydock · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 993404
29 May 1986
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1292643
Deficiency record · 81
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 June 2008
Resolved
Properly conduct u/w drills (MOB & FF) and submit written documentation to the attending CG MI prior to operating with passengers.
Documentation › Markings/Placards › Lifejacket Placard
Issued 25 June 2008
Resolved
Properly post appropriate life jacket donning placard.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 June 2008
Resolved
Properly place vessel name on lifebuoy.
Lifesaving › Lifebuoys › Immediately Available
Issued 25 June 2008
Resolved
Properly install quick acting detachable link on lifebuoy.
Communications › Radio Communications › EPIRB
Issued 25 June 2008
Resolved
Properly replace battery in EPRIB.
Navigation › Piloting/Steering › Magnetic Compass
Issued 25 June 2008
Resolved
Prove proper operation of light on magnetic compass.
Engineering › Fuel Oil Service System › Ventilation
Issued 25 June 2008
Resolved
Properly replace fuel vent screens on fuel vent pipes.
Stability › Watertight Integrity › General
Issued 11 March 2008
Resolved
Properly replace toilet through hull fitting.
Stability › Watertight Integrity › General
Issued 11 March 2008
Resolved
Properly replace holding tank through hull fitting.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 11 March 2008
Resolved
Properly replace water intake for toilet.
Engineering › Bilge Water Management System › Piping
Issued 11 March 2008
Resolved
Submit repair proposal for wasted upper bilge clamp on stbd side lazarette.
Stability › Watertight Integrity › General
Issued 11 March 2008
Resolved
Properly repair wasted area in watertight bulkhead stbd side engine room aft.
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 March 2008
Resolved
Replace keel bolts in bay 3 (center) , 4 (fwd) and 5 (fwd).
Construction/Loadline › Hull › Side Shell
Issued 11 March 2008
Resolved
Make vessel available for u/w test in order to obtain credit for dry-dock.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 19 April 2007
Resolved
Provide documentation attesting to maintaining a company drug and alcohol policy and the posting of required hotline numbers.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 April 2007
Resolved
Provide two alcohol testing kits prior to operating with passengers.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 April 2007
Resolved
Clean battery terminals.
Electrical › Electric Supply System (service) › Cable
Issued 19 April 2007
Resolved
Replace loose battery cable on port side of MDE.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 April 2007
Resolved
Provide updated copy of Coast Guard Light List.
Lifesaving › Lifebuoys › Serviceable
Issued 19 April 2007
Resolved
Remove or replace damaged additional lifering.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 April 2007
Resolved
Place quick acting corrosion resistant clip on waterlight line attached to lifering.
Engineering › Bilge Water Management System › Manifold
Issued 19 April 2007
Resolved
Prove that installed bilge system complies with 46 CFR having check valve or stop check valves at or near manifold.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 10 May 2006
Resolved
Renew port aft cabin glass/window with proper materials. 46 CFR 177.1010. Correct to the satisfaction of the attending marine inspector.
Fire Fighting › Ventilation Systems › Ducts
Issued 10 May 2006
Resolved
Provide vent closures for each engine compartment vent. 46 CFR 182.440(l). Correct to the satisfaction of the attending marine inspector.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 10 May 2006
Resolved
Provide and install inline fuse with proper amp rating for VHF radio. 46 CFR 183.392. Correct to the satisfaction of the attending marine inspector.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2006
Resolved
Diagnose issue with circuit breaker activation during fixed gas fire extinguishing system discharge. Override switch should operate/allow main engine to be restarted. 46 CFR 181.410. Correct to the satisfaction of the attending marine inspector.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 May 2006
Resolved
Make lights for each magnetic compass operate. 46 CFR 184.402. Correct to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Sheerstrake
Issued 14 March 2006
Resolved
Reseal deck at seam where deck is coupled to hull along bulwarks to prevent water intrusion. Complete to the satisfaction of the attending marine inspector.
Engineering › Bilge Water Management System › Piping
Issued 29 March 2005
Resolved
Re-new bilge piping as discussed in fuel tank compartment. 46 CFR 182.510. Correct to the satisfaction of the attending Marine Inspector.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 29 March 2005
Resolved
Properly bond fuel fill hoses for both fuel tanks. 46 CFR 182.440. Correct to the satisfaction of the attending Marine Inspector.
Engineering › Steering Gear System › Rudder Stock
Issued 29 March 2005
Resolved
Install rudder stops on rudder assembly during next drydock (non-credit). 46 CFR 182.610(e). Correct to the satisfaction of the attending Marine Inspector.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 March 2004
Resolved
Make fixed gas fire fighting system operate as designed. Currently the MDE can be re-started after discharge without the override switch being engaged. 46 CFR 181.420(b)(3). Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Operating Controls
Engineering › Fuel Oil Service System
Issued 19 February 2004
Resolved
Replace fuel tank vent screens (painted over) as required by 46 CFR 182.450(e). Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Vent screen
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 19 February 2004
Resolved
Replace (1) B-I portable fire extinguisher located on deck to meet the requirements of NFPA-10. Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Condition
Engineering › Bilge Water Management System
Issued 19 February 2004
Resolved
Replace hose (garden type) at thru-hull fitting below W/L in engine space leading to deck wash pump with a type suitable for the service intended. Double clamp hose at both ends w/barb fittings as required. 46 CFR 182.520. Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Hose
Documentation
Issued 5 April 2001
Resolved
Provide and post lifejacket donning instructions.
Unknown
Issued 5 April 2001
Resolved
Replace expired medication from first aid kit (aspirin, eye wash, iodine solution).
Fire Fighting
Issued 5 April 2001
Resolved
Provide 3 2.5 gallon fire buckets.
Lifesaving
Issued 22 April 1999
Resolved
Renew the hydrostatic release for the EPIRB.
Lifesaving
Issued 22 April 1999
Resolved
Renew painter and lifeline for the buoyant apparatus.
Lifesaving
Issued 22 April 1999
Resolved
Conduct underway man overboard and fire drills with crew in the presence ofa marine inspector.
Lifesaving
Issued 22 April 1999
Resolved
Provide a first aid kit in accordance with 46 CFR 164.041 or equivalant.
Construction/Loadline
Issued 8 July 1998
Resolved
MAKE PERMANENT REPAIRS TO FRACTURED DECK LONGS 2, 3, and 4 AFT OF THE FWD BULKHEAD IN THE FUEL TANK VOID, STBD SIDE AT THE DECK CLAMP. THE AREA IS TO BE MONITORED FOR ANY CHANGES. ALL CHANGES TO BE REPORTED TO [name withheld] OF REPAIR SCHEDULE.
Construction/Loadline
Issued 9 April 1998
Resolved
Provide plans to make proper repair to deck longs 2, 3, and 4 aft of the fwd bulkhead in the fuel tank void, strb side at the deck clamp. Longs arefractured at the bolt holes.
Navigation
Issued 9 April 1998
Resolved
Make proper repair to the rudder shaft stuffing box to reduce the amount ofwater being allowed to enter the aft void. Proper repairs to the stuffing box must be demonstrated while the vessel is underway.
Lifesaving
Issued 6 March 1997
Resolved
PROVIDE A PROPERLY REGISTERED 406 EPIRB, WITH CORRECT MOUNT, PRIOR TO OPERATION BEYOND 3 MILES.
Engineering
Issued 6 March 1997
Resolved
PROVE PROPER OPERATION OF THE REMOTE FUEL SHUTOFFS.
Accommodation/Occupational Safety
Issued 6 March 1997
Resolved
PROVIDE PROPER DOG TO PORTLIGHT IN HEAD.
Documentation
Issued 6 March 1997
Resolved
PRIOR TO OPERATION MORE THAN 1000' FROM SHORE, PROVIDE OPERATOR'S RADIO LICENSE.
Construction/Loadline
Issued 6 March 1997
Resolved
PROVIDE WATERTIGHT COVERS FOR FUEL SHUTOFF (UP TO 12" HEIGHT).
Unknown
Issued 9 October 1996
Resolved
RENEW IN LIKE KIND AND QUALITY AS ORIGINAL THE SECOND AND THIRD FLOORS FROMAFT BULKHEAD IN THE BERTHING COMPARTMENT. FASTENERS ARE TO BE SAVED FOR CGINSPECTION. THIS TO BE DONE PRIOR TO PLACING THE VESSEL IN THE WATER.
Unknown
Issued 9 October 1996
Resolved
PROPERLY REPAIR TWO WASTED BOAT NAIL HOLES IN PORT STERN QUARTER. THIS TO BE COMPLETED PRIOR TO PLACING VESSEL IN THE WATER.
Navigation
Issued 22 April 1996
Resolved
PROVIDE CURRENT CHARTS OF OPERATING AREA.
Navigation
Issued 22 April 1996
Resolved
RE-PACK THE RUDDER POST STUFFING TUBE.
Construction/Loadline
Issued 22 April 1996
Resolved
PROPERLY SEAL ALL DECK COVERING BOARD SEAMS AND GUARD SPONSON SEAMS.
Documentation
Issued 22 April 1996
Resolved
PROVIDE CURRENT FCC SAFETY RADIOTELEPHONE CERTIFICATE.
Lifesaving
Issued 22 April 1996
Resolved
PROVIDE AND PROPERLY MOUNT SECOND RING LIFE BUOY FOR BUOYANT APPARATUS.
Lifesaving
Issued 22 April 1996
Resolved
REPAIR OR REPLACE BOTH EXISTING RING LIFE BUOYS.
Construction/Loadline
Issued 12 April 1995
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS PROVIDE DOCUMENTARY PROOF OF SATISFACTORY OPERATION OF VESSELS BILGE PUMP. ITEM TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI AND NOT LATER THAN 21 APRIL 95.
Fire Fighting
Issued 12 April 1995
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS PROVIDE DOCUMENTARY PROOF OF SATISFACTORY OPERATION OF VESSEL FIRE PUMP. ITEM TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI AND NOT LATER THAN 21 APRIL 95.
Engineering
Issued 12 April 1995
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS PROVIDE DOCUMENTARY PROOF OF SATISFACTORY OPERATION OF VESSEL MAIN ENGINE. ITEM TO BE COMPLETED TO THE SATISFRACTION OF THE COGNIZANT OCMI AND NOT LATER THAN 21 APRIL 95.
Navigation
Issued 5 April 1994
Resolved
PROVIDE PROOF OF ACQUIRING A CURRENT APPROVED LIGHT LIST.
Engineering
Issued 27 April 1993
Resolved
CONDUCT SATISFACTORY TEST OF MAIN PROPULSION SYSTEM.
Construction/Loadline
Issued 27 April 1993
Resolved
CONDUCT SATISFACTORY TEST OF BILGE PUMPING SYSTEM.
Fire Fighting
Issued 27 April 1993
Resolved
PROVIDE ON BOARD HAND FIRE PUMP 5 GPM THAT WILL REACH THE WATER FROM BOATS EDGE.
Construction/Loadline
Issued 15 June 1992
Resolved
PROVIDE A WEATHER DOOR FOR THE OPENING INTO THE DECKHOUSE IN ACCORDANCE WITH 171.124 OF 46 CFR FOR A COCKPIT VESSEL.
Construction/Loadline
Issued 15 June 1992
Resolved
RAISE VENTILATION INTAKES AND EXHAUSTS IN COCKPIT PERIPHERY ABOVE GUNWALE, OR CLOSE.
Fire Fighting
Issued 11 May 1992
Resolved
PROVIDE ONE (1) USCG APPROVED B-II FIRE EXTINGUISHER IN CURRENT HYDRO.
Lifesaving
Issued 11 May 1992
Resolved
PROVIDE ONE (1) ADULT PFD UNTIL THEN VESSEL IS RESTRICTED TO 15 TOTAL PERSONS ON BOARD.
Engineering
Issued 11 May 1992
Resolved
REPLACE "DRYER HOSE" EXHAUST VENTILATION TO BILGE WITH SOLID METALLIC PIPE.
Unknown
Issued 11 May 1992
Resolved
CONDUCT STABILITY TEST FOR EXPOSED WATER.
Accommodation/Occupational Safety
Issued 11 May 1992
Resolved
MAKE MSD OPERATIONAL.
Electrical
Issued 11 May 1992
Resolved
REMOVE OR PROPERLY INSTALL MARINE GLOBE OVER LIGHT BULB SOCKET ON AFT ENGINE ROOM BULKHEAD.
Documentation
Issued 11 May 1992
Resolved
PROVIDE CURRENT VESSEL DOCUMENT.
Construction/Loadline
Issued 24 January 1989
Resolved
RENEW AS ORIGINAL 3RD, 4TH, 5TH, AND 6TH FRAMES FWD OF THE TRANSOM ON THE STBD SIDE IN THE LAZARETTE. NOTE: SUBJ FRAMES ARE CURRENTLY SISTERED, BUT IT WILL NOT BE NECESSARY TO REPLACE THE SISTERS, ONLY THE ORIGINAL FRAMES.
Lifesaving
Issued 8 December 1988
Resolved
PROVIDE ADDITIONAL ADULT-SIZE PFD. TOTAL PERSONS ALLOWED IS LIMITED TO 15 UNTIL THIS REQUIREMENT IS MET.
Construction/Loadline
Issued 8 December 1988
Resolved
WHERE BOLTS HAVE LOST THEIR STRENGTH DUE TO CORROSION, RENEW AS NECESSARY TO RETURN STRUCTURE TO ORIGINAL CONDITION. IN CONJUNCTION W/THIS REQ'T, A MARINE INSPECTOR MUST BE PRESENT WHEN A REPRESENTATIVE NO. OF THRU-BOLTS ARE REMOVED TO ASCERTAIN THEIR GENERAL CONDITION THROUGHOUT THE VESSEL.
Lifesaving
Issued 8 December 1988
Resolved
REPLACE FLOAT-FREE LINK WITH AN APPROVED TYPE OF THE APPROPRIATE SIZE.
Engineering
Issued 8 December 1988
Resolved
PROVIDE REINFORCEMENT/PROPERLY INSTALL EXHAUST PIPING IN LAZARETTE COMPT. SO AS TO ELIMINATE THE LIKELIHOOD OF IT COMING LOOSE IN A SEAWAY.
Construction/Loadline
Issued 8 December 1988
Resolved
PROVIDE DECK HATCHES WITH CAPTIVE CHAINS OR LANYARDS TO PREVENT THEIR LOSS.
Navigation
Issued 8 December 1988
Resolved
REMOVE DETERIORATED HYDRAULIC HOSE FROM STEERING ASSEMBLY IN LAZARETTE COMPT. AND REPLACE WITH HOSE OF AN APPROVED TYPE.
Casualty record · 1
23 September 2012Routine · role: Involved in a Marine Casualty · activity 4448881
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.