MAURY USCG vessel records Sign in
← All vessels

OTTAWA

OTTAWA is a 1959 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1984, most recently in July 2026, along with 106 deficiencies, 2 operational controls and 3 casualty investigations between 2012 and 2025.

Records from 1984 to 2026. Most recent: inspection, 7 July 2026.

Built
1959
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WJD4881
Flag
UNITED STATES
367782080
Maury page id
psix-43694

Inspections, by type

…with no type recorded6
Years with a record 42 calendar years (1984–2026)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)91.0 ft × 29.8 ft × 5.2 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAASCH MARINE SERVICE · ERIE, PA, UNITED STATES · built 1959
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4881MMSI 367782080 · active · compulsorily equipped · granted 11 April 2017, expires 11 April 2027
WDI6719MMSI 367721540 · expired · compulsorily equipped · granted 17 March 2016, cancelled 23 May 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 94

7 July 2026 In-Service Inspection · Special Consideration · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8431836
13 June 2026 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8403501
1 June 2026 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8385665
1 December 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8275545
29 November 2025 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8278060
5 November 2025 Special Consideration · Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8264586
24 October 2025 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8255685
17 September 2025 In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8237272
13 January 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8062713
16 September 2024 In-Service Inspection · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8036634
9 September 2024 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999079
26 July 2024 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7967780
1 July 2024 COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7946544
13 December 2023 COI Inspection · MTSA Verification · Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7838628
28 November 2023 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7838270
31 August 2023 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7781536
21 August 2023 Inclining Experiment · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7773563
28 November 2022 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7600785
9 December 2021 Hull Examination · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7368034
13 October 2021 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7331623
23 August 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7296120
1 May 2021 MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7184049
10 December 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7113121
22 September 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7062855
1 June 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6965134
25 September 2019 In-Service Inspection · Deficiency Check · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6820036
11 April 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6713557
31 October 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6577282
1 October 2018 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6562086
25 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548305
14 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6540542
5 April 2018 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6385587
12 September 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6267372
10 August 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6240330
29 June 2017 COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6160867
23 December 2016 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6061698
13 December 2016 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6061679
1 November 2016 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6059063
1 June 2016 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6019942
26 May 2016 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5887420
17 December 2015 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5783947
29 September 2015 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5731607
13 August 2015 Plan Review (Other than "T")
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5216135
6 August 2015 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5212312
18 June 2014 Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4893291
18 June 2014 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4893322
21 May 2014 COI Inspection · Plan Review (Other than "T") · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4883757
6 January 2012 Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4219603
19 August 2011 Deficiency Check · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4124971
3 August 2011 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4108923
29 July 2011 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4113647
29 July 2011 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4118576
18 July 2011 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4085618
29 September 2010 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3860400
20 September 2010 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3853649
30 July 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3551399
16 July 2008 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3338565
15 July 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3338539
8 May 2007 COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2953950
20 July 2006 Periodic Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2723167
7 July 2006 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2704854
31 May 2006 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2667232
9 June 2005 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2389324
2 June 2005 MTSA Verification
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2376745
30 August 2004 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2181371
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978146
8 July 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1840671
8 May 2002 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1626430
25 July 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1393749
22 February 2001 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1059616
12 October 2000 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1444435
17 May 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1421891
25 May 1999 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1384157
7 May 1998 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1125013
15 May 1997 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1091991
9 May 1996 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1088198
3 October 1995 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1182568
10 May 1995 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 870400
12 May 1994 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1168931
4 May 1994 Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1168926
12 May 1993 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1145955
12 May 1992 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 944745
12 May 1992 Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 959248
4 June 1991 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 918650
20 September 1990 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1231464
17 May 1990 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1232580
17 May 1989 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1195354
16 May 1988 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1196785
14 May 1987 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1335934
6 August 1986 Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1001373
13 May 1986 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 993795
10 October 1985 Credit Drydock
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 992889
14 May 1985 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 979479
28 September 1984 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1281476

Deficiency record · 106

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2026 Resolved
Fire pump failed to catch a prime when energized from the pilot house. Mechanics believe an error was made in the staging of the pump after last use. Add instructions and train crew on how to correctly stage pump for emergency firefighting and monitor over the next 5 days for effectiveness.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 4 June 2026
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 1 June 2026 Resolved
Fuel line going forward into the machinery space is slowly leaking at/ or near the emergency fuel shut off valve showing a minimal accumulation in the bilge. Investigate the source and report back to the CG with a repair plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 4 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2026 Resolved
Found 7 adult and 1 child sized life jackets with UV damage and were deemed unservicable and destroyed. 8 jackets were replaced on the spot.
Action required: 10 - Deficiency Rectified
Due 1 June 2026
Resolved 1 June 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2025 Resolved
Circuit breakers installed onboard do not meet UL489.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 December 2025
Resolved 9 December 2025
Resolution: All con-compliant circuit breakers were removed and replaced with UL489 compliant C/B's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 September 2025 Resolved
Pilothouse and local gauges, indicators and controls for newly installed gen-sets must be installed and operational testing witnessed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 29 January 2026
Resolution: corrected. witnessed all gauges & indicators in pilothouse & engine room correctly functioning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 September 2025 Resolved
Both new gen-sets are designed to operate in ambient temperatures not to exceed 40 degrees C. Both gen-sets must be derated to 80% of full load rating and properly placarded. Alternatively, vessel owner must prove engineroom temperature will not exceed 40 degrees C under normal operating conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 6 October 2025
Resolution: Genset placards depict operating parameters not to exceed 50 degrees C as required by the regs, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2025 Resolved
Circuit breaker for port side forward accom. space heater is inoperative, must be replaced. Heater shall not be used until corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 30 September 2025
Resolution: C/B replaced, functional test witnessed all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2025 Resolved
Both MDE RPM local gauges are inoperative, must be corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 9 December 2025
Resolution: sighted local gauges installed and properly functioning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2025 Resolved
#5 void bilge foot corroded, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 18 September 2025
Resolution: replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 September 2025 Resolved
2 forwardmost void access covers require repair/replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 4 November 2025
Resolution: covers repaired to properly close and remain watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 March 2025 Resolved
Newly installed single-phase generator shall not be operated while passengers are on-board until necessary approvals are returned satisfactorily from Coast Guard Marine Safety Center. Gen-set and associated breakers must be secured prior to the embarkation of any passengers. 46CFR182.310
Action required: 705 - Other - as specified
Due 18 March 2025
Resolved 18 September 2025
Resolution: Gen-set and heater system inspected and tested with satisfactory results.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 July 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel made notification that the port shaft tube was installed incorrectly causing the port shaft to overheat. Make repairs to the port shaft tube to the satisfaction of the OCMI. 46 CFR 177.100 / 701 / c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2025
Resolution: witnessed satisfactory underway trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 July 2024 Resolved
Found both operating station transmission pressure gauges inoperative. Repair or replace and demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 18 March 2025
Resolution: corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 May 2021 Resolved
Make main deck access covers for voids 1, 2, 3 and shaft alley compartment operational. ** Cite 46CFR116.1160 not selectable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 23 August 2021
Resolution: corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 May 2021 Resolved
5 main deck bench seats are a hazard to passengers, require repair. Make inaccessible to passengers until properly repaired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 1 July 2024
Resolution: repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2021 Resolved
Port MDE has oil leak in/around air start selenoid. Monitor/investigate; effect permanent repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 23 August 2021
Resolution: cleaned, repaired, monitored.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2021 Resolved
Stbd MDE exhaust temperature sensor damaged. Effect permanent repairs and demonstrate proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 23 August 2021
Resolution: repaired.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 May 2021 Resolved
Sprinkler pump packing leaking excessively. Repair and demonstrate proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 23 August 2021
Resolution: repaired. sighted proper operation.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 22 September 2020 Resolved
Numerous benches on the top deck need the center support reattached to the bench base.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 17 December 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 September 2020 Resolved
Remove/ cap off dead end wires on the bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 17 December 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 September 2020 Resolved
Wiring for installed heaters in passenger space is affixed with zip ties and is resting on a rotating portion of the steering gear. Remove the wire from the steering gear and replace zip ties with metal supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 17 December 2020
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2019 Resolved
Replace missing stern light and adjust Nav Light configuration IAW Inland Navigation Rules. 46 CFR 120.420 ** Extended pending OCMI interpretation resolution. Owner awaiting decision prior to modification. **
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 1 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 September 2019 Resolved
Replace missing guard on light in second void. 46 CFR 120.410(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 October 2019
Resolution: Replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 September 2019 Resolved
Repair cracks on port rubrail. 46 CFR 115.802(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 24 October 2019
Resolution: All cracks welded on exterior of rubrail. I informed owmer this is considered a long term temp repair which will be called out for completion at next hull exam.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 September 2019 Resolved
Replace missing lagging in Engine Room. 46 CFR 116.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 October 2019
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 25 September 2019 Resolved
Repair stbd tachometer in Engine Room. 46 CFR 119.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 23 September 2020
Resolution: Removed tachs in the engine room.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2019 Resolved
Replace bulbs in port and stbd running lights. 46 CFR 120.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 October 2019
Resolution: corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 25 September 2019 Resolved
Repair damaged seats. 25 benches on the upper deck and 9 benches on the main deck. 46 CFR 116.820(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 30 June 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2019 Resolved
Clean/ Replace clogged strainers in 4th void bilge. 46 CFR 119.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 24 October 2019
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 September 2019 Resolved
Cap pipe in second void aft watertight bulkhead. 46 CFR 115.802(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 October 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2019 Resolved
Found numerous PFDs that needed retro replaced and 2 that had to be removed from service due to poor overall condition.
Action required: 10 - Deficiency Rectified
Due 25 September 2019
Resolved 25 September 2019
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 September 2019 Resolved
Clean and descale interior of air recievers. Test pressure relief valve. 46 CFR 54.10-3(b)
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 30 June 2020
Resolution: Cleaned and descaled.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 October 2018 Resolved
Make main deck access covers operational and watertight. (referred cite: 46CFR116.1160 not selectable below)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2018
Resolved 1 October 2018
Resolution: Vessel rep informed me the access covers were made operational & watertight by the time I'd returned to the office.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2018 Resolved
Bilge alarm audible alarm is inoperative. Correct and demonstrate proper operation. ** Until item #2 is corrected, crew is required to check engineroom and lazzarette after each run, not to exceed 30 minutes.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 31 October 2018
Resolution: witnessed proper operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2018 Resolved
Generator battery box must be secured from movement and battery must be chocked in box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 31 October 2018
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 October 2018 Resolved
#5 void (doghouse) bilge pipe foot wasted, must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 31 October 2018
Resolution: replaced
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 October 2018 Resolved
Voids #3 & #4 require sounding tubes or quick acting access covers to allow for sounding or checking the compartment regularly for flooding. (referred cite: 46CFR116.1160 not selectable below)
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 11 April 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2018 Resolved
Monitor genset oil leak. Prove proper operation after winter overhaul.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 11 April 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 October 2018 Resolved
Fire pumps, sprinkler pump & associated controls must be properly labeled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 31 October 2018
Resolution: corrected
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018 Resolved
The vessel is currently broadcasting (1) Improper MMSI Number (2) Improper Call Sign, (3) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2018
Resolved 7 December 2018
Resolution: Owner corrected errors
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018 Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) Not broadcasting a Call Sign, (3) Zero Length and Beam, (4) No Ship Type. Vessel must have proper Ship Type per the official US Encoding guide, (5) Improper IMO Number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2018
Resolved 7 December 2018
Resolution: errors corrected
Communications › Radio Communications › VHF Radiotelephone
Issued 6 July 2017 Resolved
Provide Great Lakes agreement radio inspection certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 18 July 2017
Resolution: Recieved inspection report via e-mail.
Stability › Freeing Ports › General
Issued 6 July 2017 Resolved
Repair stbd aft freeing port non-return flap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 August 2017
Resolution: Repaired.
Construction/Loadline › Hull › Hull Plating
Issued 6 July 2017 Resolved
De-scale shaft alley compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 12 September 2017
Resolution: Completed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 July 2017 Resolved
Properly mark E/R emergency escape in engineroom.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 August 2017
Resolution: Marked.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 December 2016 Resolved
Install #2 and #3 void hatch covers missing locking pins per 46CFR116.1160.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 6 July 2017
Resolution: Corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 19 December 2016 Resolved
Replace cracked main deck port side forth window from front.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 6 July 2017
Resolution: Replaced.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 19 December 2016 Resolved
All replaced piping in engineroom for bilge and raw water cooling systems shall be operationally tested at next inspection for certification.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2017
Resolved 6 July 2017
Resolution: Tested.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 September 2015 Resolved
Replace expired items in the first aid kit.
Action required: 705 - Other - as specified
Due 2 October 2015
Resolved 17 December 2015
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 September 2015 Resolved
Properly secure the exhaust lagging on both MDE's.
Due 2 October 2015
Resolved 17 December 2015
Fire Fighting › Fire Pumps › Location
Issued 6 August 2015 Resolved
Use fire pump on portside engine room instead of electric fire/bilge pump on starboard side for firefighting.
Action required: 705 - Other - as specified
Due 6 September 2015
Resolved 6 August 2015
Resolution: Demonstrated proper operation of portside engine room electric fire pump.
Fire Fighting › Fire Pumps › Arrangement
Issued 6 August 2015 Resolved
Submit plans for replacement of electric fire/bilge pump.
Action required: 705 - Other - as specified
Due 6 September 2015
Resolved 13 August 2015
Resolution: Received plans for new pump.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 18 June 2014 Resolved
Make proper repairs to stbd main engine prior to operation to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2014
Resolved 23 June 2014
Fire Fighting › Fire Pumps › Pressure
Issued 21 May 2014 Resolved
Repair and prove proper operation of main fire pump at 50 GPM and 60 PSIG.
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 23 June 2014
Resolution: Drive motor replaced in kind.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 21 May 2014 Resolved
Prove proper operation of propulsion engine tachometers in wheelhouse and engineroom.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 23 June 2014
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 21 May 2014 Resolved
Properly label bilge suction manifold and fire pump sea valve and demonstrate adequacy of crew ability to comprehend and operate same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 23 June 2014
Construction/Loadline › Structures › Deck Plating
Issued 6 January 2012 Resolved
Crop and insert deck plating and transom stiffeners in way of transom. Completed during inspection.
Action required: 705 - Other - as specified
Resolved 10 January 2012
Resolution: Repair completed during this inspection.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 19 August 2011 Resolved
Repair lube oil leak on port main engine reduction gear.
Action required: 705 - Other - as specified
Due 19 September 2011
Resolved 29 August 2011
Resolution: Installed lube oil distributer cap on port main engine reduction gear.
Engineering › Fuel Oil Service System › Hose
Issued 19 August 2011 Resolved
Repair fuel oil leak on port main engine flexible fuel line prior to underway operations.
Action required: 705 - Other - as specified
Due 19 September 2011
Resolved 29 August 2011
Resolution: Installed replacement flexible fuel line on port main engine.
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 August 2011 Resolved
Replace retro-reflective tape two of the 22-person life floats.
Action required: 705 - Other - as specified
Due 19 September 2011
Resolved 14 September 2011
Resolution: Retro-reflective tape on the two 22-person life floats.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 19 August 2011 Resolved
Provide guard for fire pump shaft.
Action required: 705 - Other - as specified
Due 19 September 2011
Resolved 29 August 2011
Resolution: Installed guard for fire pump shaft.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 19 August 2011 Resolved
Provide permanently affixed draft marks.
Action required: 705 - Other - as specified
Due 29 April 2012
Resolved 23 April 2012
Resolution: Sighted digital photos submitted via email showing draft marks properly placed IAW Sectio 122.602.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 19 August 2011 Resolved
Install door handle and luver on dunnage room.
Action required: 705 - Other - as specified
Due 19 October 2011
Resolved 29 August 2011
Resolution: Door handle and luver installed on dunnage room.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 September 2010 Resolved
Proved and post a vessels specific fire control plan as required by 46CFR116.530.
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 20 June 2011
Resolution: Not required for an Old "T" Large vessel.
Lifesaving › Lifefloat › Paddle
Issued 29 September 2010 Resolved
Mark the vessels name on all of the vessels lifefloat paddles as required by 46CFR122.604(g).
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 19 August 2011
Resolution: Vessel''s name marked on life float paddles.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 September 2010 Resolved
Mark the vessels lifejacket stowage as required by 46CFR122.604(f).
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 19 August 2011
Resolution: Vessel''s life jacket stowage marked with correct #/size of life jackets.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 September 2010 Resolved
Post emergency broadcast placard next to the VHF radio as required by 46CFR121.506.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 19 August 2011
Resolution: Emergency broadcast placard posted next to VHF radio.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 29 September 2010 Resolved
Provide the number of lifejackets required by the COI or request a passenger count reduction. Provide a lifejacket for everyone on board as required by 46CFR117.71.
Action required: 705 - Other - as specified
Due 30 October 2010
Resolved 19 August 2011
Resolution: 510 adult size and 83 child size life jackets onboard the vessel which exceeds the requirement on the COI.
Lifesaving › Lifefloat › Serviceable
Issued 15 July 2008 Resolved
Lifeline/pendants worn and deteriorated, stenciling faded, minor tears in outer covering. Service LF.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2008
Resolved 16 July 2008
Resolution: Serviced LF''s.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 July 2008 Resolved
COD expired. Provide copy to SEC Sault Inspections office via fax.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 16 July 2008
Resolution: Fax copy received.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 May 2007 Resolved
Make collision bulkhead watertight by either removing piping in the overhead or plugging.
Due 8 July 2007
Resolved 7 June 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 May 2007 Resolved
Remove or install plug in bulkhead piping between laz space and fuel tank compt.
Due 8 July 2007
Resolved 7 June 2007
Engineering › Lubricating Oil Service System › Filter
Issued 8 May 2007 Resolved
Renew gasket/ o-ring on oil supply and return lines in the vicinity of the oil filter housing to the MDE.
Due 7 July 2007
Resolved 6 July 2007
Engineering › Fuel Oil Service System › Pump
Issued 8 May 2007 Resolved
Renew gasket/ o-ring on gear oil lube system for fuel pump on port engine
Due 7 July 2007
Resolved 6 July 2007
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 8 May 2007 Resolved
Install new ground wire connection from the starter solenoid to block on stbd engine.
Due 7 July 2007
Resolved 6 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2007 Resolved
remove or connect wiring for instrumentation on the after side of the port MDE.
Due 7 July 2007
Resolved 6 July 2007
Lifesaving › Lifebuoys › Serviceable
Issued 20 July 2006 Resolved
replace life ring on main deck missing retro and line hangers as per 46cfr117.70
Due 20 August 2006
Resolved 21 August 2006
Resolution: replaced life ring
Lifesaving › Lifebuoys › Serviceable
Issued 20 July 2006 Resolved
APPLY RETRO TO UPPER DECK LIFE RING ON PORTSIDE OF PILOT HOUSE, AS PER 46CFR117.70
Due 20 August 2006
Resolved 20 August 2006
Resolution: Retroflective material replaced on life rings
Lifesaving › Lifefloat › Lifeline
Issued 20 July 2006 Resolved
RE STRING LIFE FLOAT MANROPES AND BASKET NETTING WITH FIBROUS LINE AS PER SUBCHAPTER Q.
Due 20 August 2006
Resolved 20 August 2006
Resolution: all hanks secured with cotton fiber small stuff
Lifesaving › Lifefloat › Paddle
Issued 20 July 2006 Resolved
REPLACE 5 DILAPIDATED LIFE FLOAT PADDLES PER 46CFR117.175
Due 20 August 2006
Resolved 20 August 2006
Resolution: Replaced paddles
Documentation › Certificates/Documents › FCC SSL
Issued 20 July 2006 Resolved
PROVIDE VALID FCC RADIO CERTIFICATE PER 46CFR121.502
Due 20 August 2006
Resolved 20 August 2006
Resolution: Faxed valid FCC license to Sector Sault Inspection
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 July 2006 Resolved
Correct hailing port on cert of documentation at next renewal.
Due 31 May 2008
Resolved 23 June 2008
Resolution: Received fax confirming update to COD.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 June 2005 Resolved
Label Life Jacket stowage area main deck with the amount and type (child-adult)
Condition: Unknown
Due 20 June 2005
Resolved 20 June 2005
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump
Issued 9 June 2005 Resolved
Repair sprinkler pump elbow and gasket in the engine room.
Condition: Unknown
Due 20 June 2005
Resolved 20 June 2005
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 9 June 2005 Resolved
Make available for internal inspection the two Air Receivers.
Condition: Unknown
Due 20 June 2005
Resolved 20 June 2005
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 8 July 2003 Resolved
INSTALL ELECTRICAL COVER ON BREAKER BOX FOR AIR COMPRESSOR IN ENGINE ROOM.
Due 9 August 2003
Resolved 30 August 2004
Fire Fighting › Fire Pumps
Issued 8 May 2002 Resolved
Repair or replace main fire pump and prove operation of at least 50 GPM and 60 PSI prior to carrying passengers and prior to the compliance date. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Due 15 May 2002
Resolved 28 May 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 May 2002 Resolved
Replace port shaft packing seal to prevent excess leaking prior to the compliance date.
Condition: Unknown
Due 31 May 2002
Resolved 28 May 2002
Navigation › Collision/Grounding Avoidance
Issued 8 May 2002 Resolved
Provide a ships bell of at least 300 mm prior to operations and prior to the compliance date.
Condition: Unknown
Due 31 May 2002
Resolved 28 May 2002
Lifesaving
Issued 25 July 2001 Resolved
Install proper size weak-link for life-float, port side forward, prior to the compliance date.
Condition: Unknown
Due 10 August 2001
Resolved 31 July 2001
Construction/Loadline
Issued 25 July 2001 Resolved
Tighten bilge pipe connection in # 3 compartment prior to the compliance date.
Condition: Unknown
Due 10 August 2001
Resolved 31 July 2001
Documentation
Issued 25 July 2001 Resolved
Post copy of station bill prior to the compliance date.
Condition: Unknown
Due 10 August 2001
Resolved 31 July 2001
Lifesaving
Issued 25 July 2001 Resolved
Re-mount waterlight for life-float, starboard side forward, prior to the compliance date.
Condition: Unknown
Due 10 August 2001
Resolved 31 July 2001
Construction/Loadline
Issued 12 October 2000 Resolved
Clean hull, conduct repairs to hull pitting as per approved repair proposal.
Condition: Unknown
Due 17 October 2000
Resolved 29 November 2000
Electrical
Issued 12 October 2000 Resolved
Replace plastic electrical wire tie holders in the # 6 compartment with metal hangers as required by 46 CFR 183.340 prior to the compliance date.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Construction/Loadline
Issued 12 October 2000 Resolved
Remove ater from # 8 compartment bilge and make ready for inspection.
Condition: Unknown
Due 31 October 2000
Resolved 29 November 2000
Navigation
Issued 12 October 2000 Resolved
Tighten coupling bolts for starboard rudder bearing retainer prior to the compliance date.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Engineering
Issued 12 October 2000 Resolved
Repair exhaust lagging for exposed port and starboard main engine exhaust piping prior to the compliance date.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Construction/Loadline
Issued 12 October 2000 Resolved
Replace four (4) broken main glass windows on the main deck, port side, aftwith tempered glass prior to the compliance date.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Construction/Loadline
Issued 12 October 2000 Resolved
Replace hatch cover gaskets for # 4 and # 6 compartments prior to the compliance date.
Condition: Unknown
Due 12 October 2000
Resolved 12 October 2000
Accommodation/Occupational Safety
Issued 17 May 2000 Resolved
PURSER'S CAGE LITTERED WITH DIRTY RAGS AND FLAMMABLES, CORRECTED.
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Lifesaving
Issued 17 May 2000 Resolved
RELABLE THE CAPACITY ON EACH BUOYANT APPARATUS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 24 May 2000
Resolved 27 June 2000
Lifesaving
Issued 17 May 2000 Resolved
PROVIDE LIFE FLOAT IN REPLACEMENT OF DECAYED BALSA 20 PERSON BUOYANT APPARATUS, BEFORE THE COMPLIANCE DATE. MEANWHILE VESSEL IS LIMITED TO NOT MORE THAN 560 TOTAL PERSONS ABOARD.
Condition: Unknown
Due 17 June 2000
Resolved 27 June 2000
Engineering
Issued 25 May 1999 Resolved
REPLACE FLEXIBLE FUEL LINES ON STARBOARD MDE PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Engineering
Issued 25 May 1999 Resolved
REPLACE SAFETY RELIEF VALVE FOR MDE START PRESSURE VESSELS PRIOR TO THE COMPLIANCE DATE AND DEMONSTRATE RELIEF VALVE SETTING.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Documentation
Issued 25 May 1999 Resolved
POST EMERGENCY INSTRUCTION LIST AS REQUIRED BY 46 CFR 185.510 PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999

Casualty record · 3

7 October 2012Routine · role: Involved in a Marine Casualty · activity 4476695
18 June 2014Routine · role: Involved in a Marine Casualty · activity 4893322
29 November 2025Routine · role: Involved in a Marine Casualty · activity 8278060
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.