Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 July 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WJD4881
Flag
UNITED STATES
Maury page id
psix-43694

Documentation record

Registered dimensions (L × B × D)91.0 ft × 29.8 ft × 5.2 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAASCH MARINE SERVICE · ERIE, PA, UNITED STATES · built 1959
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMACKINAC ISLAND, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 20 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 40 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 40

7 July 2026 In-Service Inspection · Special Consideration · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8431836
13 June 2026 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8403501
1 June 2026 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8385665
1 December 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8275545
29 November 2025 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8278060
5 November 2025 Special Consideration · Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8264586
24 October 2025 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8255685
17 September 2025 In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8237272
13 January 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8062713
16 September 2024 In-Service Inspection · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8036634
9 September 2024 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999079
26 July 2024 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7967780
1 July 2024 COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7946544
13 December 2023 COI Inspection · MTSA Verification · Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7838628
28 November 2023 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7838270
31 August 2023 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7781536
21 August 2023 Inclining Experiment · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7773563
28 November 2022 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7600785
9 December 2021 Hull Examination · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7368034
13 October 2021 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7331623
23 August 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7296120
1 May 2021 MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7184049
10 December 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7113121
22 September 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7062855
1 June 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6965134
25 September 2019 In-Service Inspection · Deficiency Check · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6820036
11 April 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6713557
31 October 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6577282
1 October 2018 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6562086
25 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548305
14 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6540542
5 April 2018 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6385587
12 September 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6267372
10 August 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6240330
29 June 2017 COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6160867
23 December 2016 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6061698
13 December 2016 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6061679
1 November 2016 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6059063
1 June 2016 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6019942
26 May 2016 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5887420

Deficiency record · 48

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2026 Resolved
Fire pump failed to catch a prime when energized from the pilot house. Mechanics believe an error was made in the staging of the pump after last use. Add instructions and train crew on how to correctly stage pump for emergency firefighting and monitor over the next 5 days for effectiveness.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 4 June 2026
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 1 June 2026 Resolved
Fuel line going forward into the machinery space is slowly leaking at/ or near the emergency fuel shut off valve showing a minimal accumulation in the bilge. Investigate the source and report back to the CG with a repair plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 4 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2026 Resolved
Found 7 adult and 1 child sized life jackets with UV damage and were deemed unservicable and destroyed. 8 jackets were replaced on the spot.
Action required: 10 - Deficiency Rectified
Due 1 June 2026
Resolved 1 June 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2025 Resolved
Circuit breakers installed onboard do not meet UL489.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 December 2025
Resolved 9 December 2025
Resolution: All con-compliant circuit breakers were removed and replaced with UL489 compliant C/B's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 September 2025 Resolved
Pilothouse and local gauges, indicators and controls for newly installed gen-sets must be installed and operational testing witnessed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 29 January 2026
Resolution: corrected. witnessed all gauges & indicators in pilothouse & engine room correctly functioning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 September 2025 Resolved
Both new gen-sets are designed to operate in ambient temperatures not to exceed 40 degrees C. Both gen-sets must be derated to 80% of full load rating and properly placarded. Alternatively, vessel owner must prove engineroom temperature will not exceed 40 degrees C under normal operating conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 6 October 2025
Resolution: Genset placards depict operating parameters not to exceed 50 degrees C as required by the regs, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2025 Resolved
Circuit breaker for port side forward accom. space heater is inoperative, must be replaced. Heater shall not be used until corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 30 September 2025
Resolution: C/B replaced, functional test witnessed all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2025 Resolved
Both MDE RPM local gauges are inoperative, must be corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 9 December 2025
Resolution: sighted local gauges installed and properly functioning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2025 Resolved
#5 void bilge foot corroded, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 18 September 2025
Resolution: replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 September 2025 Resolved
2 forwardmost void access covers require repair/replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025
Resolved 4 November 2025
Resolution: covers repaired to properly close and remain watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 March 2025 Resolved
Newly installed single-phase generator shall not be operated while passengers are on-board until necessary approvals are returned satisfactorily from Coast Guard Marine Safety Center. Gen-set and associated breakers must be secured prior to the embarkation of any passengers. 46CFR182.310
Action required: 705 - Other - as specified
Due 18 March 2025
Resolved 18 September 2025
Resolution: Gen-set and heater system inspected and tested with satisfactory results.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 July 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel made notification that the port shaft tube was installed incorrectly causing the port shaft to overheat. Make repairs to the port shaft tube to the satisfaction of the OCMI. 46 CFR 177.100 / 701 / c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2025
Resolution: witnessed satisfactory underway trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 July 2024 Resolved
Found both operating station transmission pressure gauges inoperative. Repair or replace and demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 18 March 2025
Resolution: corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 May 2021 Resolved
Make main deck access covers for voids 1, 2, 3 and shaft alley compartment operational. ** Cite 46CFR116.1160 not selectable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 23 August 2021
Resolution: corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 May 2021 Resolved
5 main deck bench seats are a hazard to passengers, require repair. Make inaccessible to passengers until properly repaired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 1 July 2024
Resolution: repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2021 Resolved
Port MDE has oil leak in/around air start selenoid. Monitor/investigate; effect permanent repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 23 August 2021
Resolution: cleaned, repaired, monitored.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2021 Resolved
Stbd MDE exhaust temperature sensor damaged. Effect permanent repairs and demonstrate proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 23 August 2021
Resolution: repaired.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 May 2021 Resolved
Sprinkler pump packing leaking excessively. Repair and demonstrate proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 23 August 2021
Resolution: repaired. sighted proper operation.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 22 September 2020 Resolved
Numerous benches on the top deck need the center support reattached to the bench base.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 17 December 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 September 2020 Resolved
Remove/ cap off dead end wires on the bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 17 December 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 September 2020 Resolved
Wiring for installed heaters in passenger space is affixed with zip ties and is resting on a rotating portion of the steering gear. Remove the wire from the steering gear and replace zip ties with metal supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 17 December 2020
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2019 Resolved
Replace missing stern light and adjust Nav Light configuration IAW Inland Navigation Rules. 46 CFR 120.420 ** Extended pending OCMI interpretation resolution. Owner awaiting decision prior to modification. **
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 1 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 September 2019 Resolved
Replace missing guard on light in second void. 46 CFR 120.410(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 October 2019
Resolution: Replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 September 2019 Resolved
Repair cracks on port rubrail. 46 CFR 115.802(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 24 October 2019
Resolution: All cracks welded on exterior of rubrail. I informed owmer this is considered a long term temp repair which will be called out for completion at next hull exam.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 September 2019 Resolved
Replace missing lagging in Engine Room. 46 CFR 116.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 October 2019
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 25 September 2019 Resolved
Repair stbd tachometer in Engine Room. 46 CFR 119.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 23 September 2020
Resolution: Removed tachs in the engine room.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2019 Resolved
Replace bulbs in port and stbd running lights. 46 CFR 120.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 October 2019
Resolution: corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 25 September 2019 Resolved
Repair damaged seats. 25 benches on the upper deck and 9 benches on the main deck. 46 CFR 116.820(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 30 June 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2019 Resolved
Clean/ Replace clogged strainers in 4th void bilge. 46 CFR 119.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 24 October 2019
Resolution: corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 September 2019 Resolved
Cap pipe in second void aft watertight bulkhead. 46 CFR 115.802(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 October 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2019 Resolved
Found numerous PFDs that needed retro replaced and 2 that had to be removed from service due to poor overall condition.
Action required: 10 - Deficiency Rectified
Due 25 September 2019
Resolved 25 September 2019
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 September 2019 Resolved
Clean and descale interior of air recievers. Test pressure relief valve. 46 CFR 54.10-3(b)
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 30 June 2020
Resolution: Cleaned and descaled.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 October 2018 Resolved
Make main deck access covers operational and watertight. (referred cite: 46CFR116.1160 not selectable below)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2018
Resolved 1 October 2018
Resolution: Vessel rep informed me the access covers were made operational & watertight by the time I'd returned to the office.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2018 Resolved
Bilge alarm audible alarm is inoperative. Correct and demonstrate proper operation. ** Until item #2 is corrected, crew is required to check engineroom and lazzarette after each run, not to exceed 30 minutes.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 31 October 2018
Resolution: witnessed proper operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2018 Resolved
Generator battery box must be secured from movement and battery must be chocked in box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 31 October 2018
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 October 2018 Resolved
#5 void (doghouse) bilge pipe foot wasted, must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2018
Resolved 31 October 2018
Resolution: replaced
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 October 2018 Resolved
Voids #3 & #4 require sounding tubes or quick acting access covers to allow for sounding or checking the compartment regularly for flooding. (referred cite: 46CFR116.1160 not selectable below)
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 11 April 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2018 Resolved
Monitor genset oil leak. Prove proper operation after winter overhaul.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 11 April 2019
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 October 2018 Resolved
Fire pumps, sprinkler pump & associated controls must be properly labeled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 31 October 2018
Resolution: corrected
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018 Resolved
The vessel is currently broadcasting (1) Improper MMSI Number (2) Improper Call Sign, (3) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2018
Resolved 7 December 2018
Resolution: Owner corrected errors
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018 Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) Not broadcasting a Call Sign, (3) Zero Length and Beam, (4) No Ship Type. Vessel must have proper Ship Type per the official US Encoding guide, (5) Improper IMO Number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2018
Resolved 7 December 2018
Resolution: errors corrected
Communications › Radio Communications › VHF Radiotelephone
Issued 6 July 2017 Resolved
Provide Great Lakes agreement radio inspection certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 18 July 2017
Resolution: Recieved inspection report via e-mail.
Stability › Freeing Ports › General
Issued 6 July 2017 Resolved
Repair stbd aft freeing port non-return flap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 August 2017
Resolution: Repaired.
Construction/Loadline › Hull › Hull Plating
Issued 6 July 2017 Resolved
De-scale shaft alley compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 12 September 2017
Resolution: Completed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 July 2017 Resolved
Properly mark E/R emergency escape in engineroom.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 August 2017
Resolution: Marked.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 December 2016 Resolved
Install #2 and #3 void hatch covers missing locking pins per 46CFR116.1160.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 6 July 2017
Resolution: Corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 19 December 2016 Resolved
Replace cracked main deck port side forth window from front.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 6 July 2017
Resolution: Replaced.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 19 December 2016 Resolved
All replaced piping in engineroom for bilge and raw water cooling systems shall be operationally tested at next inspection for certification.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2017
Resolved 6 July 2017
Resolution: Tested.

Ownership record