Records from 2016 to 2026. Most recent: inspection, 11 May 2026.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 70 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTURGEON BAY SHIPBUILDING & DRY DOCK CO · STURGEON BAY, WI, UNITED STATES · built 1959
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAULT STE MARIE, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
11 May 2026
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8383399
22 May 2025
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8141475
20 May 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7964045
3 May 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7686181
13 April 2023
Administrative Inspection · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7667823
14 September 2022
Hull Examination · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7558745
13 June 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7476330
5 April 2022
Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7431745
15 October 2021
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7333266
6 July 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6998001
14 February 2020
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6909195
17 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6753616
23 May 2019
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6692045
14 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6540568
3 May 2018
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6405012
25 May 2017
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6158305
1 May 2017
Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6142414
12 October 2016
Deficiency Check · Drydock Extension
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6018119
18 May 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5896156
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2019
Resolved
Complete repairs and demostrate proper operation of MDE, specifically the cooling system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2019
Resolved 18 July 2019
Resolution: Crew replaced burst hose, refilled coolant and completed 20-30 operational test at the dock. CG allowed transit back company dock. CG MI attended, witnessed repairs and additional ops check, all sat. No sail cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2019
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet in length, securing the waterlight around the ring of the body. The waterlight lanyard on the upper deck, port side, is frayed and must be replaced. Replace lanyard to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 28 May 2019
Resolution: Replaced lanyard
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 23 May 2019
Resolved
Placards containing instructions for donning and use of life jackets must be posted in conspicuous places that are regularly visible to the crew. There is no life jacket instruction placard posted on the lower deck. Post placard to the satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 28 May 2019
Resolution: Posted placards
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2019
Resolved
Each life jacket must be marked with vessel's name. 1 child life jacket's marking is illegible. Re-mark life jacket to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 28 May 2019
Resolution: Life jacket properly marked
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 May 2019
Resolved
A hatch exposed to the weather must be watertight. The gaskets on the hatches leading to the forepeak and aft steering space are severely deteriorated. Replace gaskets to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 28 May 2019
Resolution: Gaskets replaced
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2019
Resolved
Batteries must be free from exposure to water splash or spray. The rubber cover for the battery in the engine room does not cover the entire battery. Provide a cover large enough to protect the entire battery to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 17 June 2019
Resolution: Installed appropriately sized battery cover
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 May 2019
Resolved
All observed unsafe practices must be corrected. The magnetic compass is displaying incorrect heading. A magnetic compass is not required on a vessel operating on a rivers route. Prove proper operation of the magnetic compass or render system inoperable from use.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2019
Resolved 17 June 2019
Resolution: installed cover labeled "inoperable"
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 23 May 2019
Resolved
Abandon ship, man overboard, and fire drills shall be logged or documented. Vessel rep unable to provide documentation of drills. Log drills appropriately for review by the attending marine inspector in 6 months.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2019
Resolved 28 July 2020
Resolution: CORRECTED
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 23 May 2019
Resolved
A seat must be constructed to minimize the possibility of injury. Multiple fixed benches on the upper deck are missing bolt attachments to the deck. Properly secure fixed benches to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2019
Resolved 28 May 2019
Resolution: Seatin properly secured
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018
Resolved
The vessel is currently broadcasting (1) Zero Length and Beam (2) Zero Draft (3) No Ship Type. The Vessel must have proper Ship Type per the official US Encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2018
Resolved 14 February 2020
Resolution: Verified AIS broadcasting correctly on NavCen website.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 18 May 2016
Resolved
Waste Receptacles must be constructed of non-combustible materials. Replace plastic trash cans with non-combustible ones.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 25 May 2017
Resolution: Replaced trash cans with non-combustible type.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 May 2016
Resolved
Fire Extinquisher not in proper mount. Mount Fire Extinquisher in wheelhouse.
Due 16 June 2016
Resolved 12 October 2016
Resolution: Wheelhouse fire extinguisher properly mounted with approved bracket.