NAUTIC STAR

NAUTIC STAR is a 1959 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in November 2023, along with 53 deficiencies — 5 with no resolution recorded — and 1 operational control.

Records from 2016 to 2023. Most recent: inspection, 15 November 2023.

Built
1959
Last inspected
15 November 2023
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 November 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH7034
Flag
UNITED STATES
Maury page id
psix-43701

Documentation record

Registered dimensions (L × B × D)52.3 ft × 15.5 ft × 2.9 ft
Registered tonnagegross 10 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderERNEST F PETTEK · DORCHESTER, NJ, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBROOKLYN, NY
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Gross Ton
7 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 53 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

15 November 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7825143
6 September 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7552266
25 January 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7385311
25 May 2021 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7203213
7 April 2021 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7154258
23 September 2020 Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7054937
19 August 2020 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7037538
18 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6955540
17 September 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6809284
21 September 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6542205
10 August 2018 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6434685
5 April 2018 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6385708
28 September 2017 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6277274
13 September 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6259753
7 October 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6015401
8 June 2016 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5901237

Deficiency record · 53

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 November 2022 No resolution recorded
Provide repair plan for excessive gap between chine and first plank in the proximity of 14 to 17 feet measured aft the bow on the starboard side due to chine log scarf wastage.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 November 2022 No resolution recorded
Provide repair plan for incorrect plank sizing in the newly fastened keel to chine plank in the proximity of 14 foot measured aft the bow on the starboard side.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 November 2022 No resolution recorded
Refasten two identified midship chine fasteners on starboard side.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 November 2022 No resolution recorded
Provide repair plan for loose butt joint on the port side, 1st plank above the chine located 42 feet measured aft the bow.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 November 2022 Resolved
Provide repair plan to make forepeak bulkhead watertight.
Action required: 705 - Other - as specified
Resolved 24 January 2023
Resolution: Inspected sealing of all gaps.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 November 2022 Resolved
Refasten chine log fastener on port side frame #3 in 2nd Void.
Action required: 705 - Other - as specified
Resolved 24 January 2023
Resolution: Verified refastening
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 November 2022 No resolution recorded
Provide repair plan for wasted through-bolt fasteners on the port side chine log scarf in the vicinity of the fuel tank.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 May 2021 Resolved
VSL required to be inspection ready. VSL not ready for inspection. Issued checklist and zone requirments to be completed and/ or reviewed prior to future inspections. As discussed bilges need to be clean and dry, documentation needs to be updated and properly endorsed, and material items to be inspected ready and available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Attended vessel; vessel was inspection ready.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 May 2021 Resolved
BA were filled with water and no longer fit for service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Vessel is not required to carry a BA due to its vessel route of less than 1 mile offshore.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 25 May 2021 Resolved
Crew not enrolled in DAPI program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Crew is enrolled in a DAPI program.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 May 2021 Resolved
Outdated and inappropriate charts and pubs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Vessel has all current charts/publications for its route.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2021 Resolved
Ring life buoy had more than 6 feet of line attached.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Vessel's ring life buoy now has 6 feet of line attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021 Resolved
F/O shut off valves seized.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: F/O shut off valve was repaired/not seized and worked properly.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 25 May 2021 Resolved
Sheathing on aft 3/4 of vsl needs to be raised to ensure designed drainage is not compromised.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Sheathing on aft 3/4 of vsl was raised and drained properly.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 May 2021 Resolved
Forward compartment must be water tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Fwd compartment was repaired and appeared to be watertight during the inspection & while u/w.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 25 May 2021 Resolved
Freeing ports required to be secured while u/w per design construction.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Freeing ports were secured while u/w.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 May 2021 Resolved
Conduct drills in the presents of inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Vessel/crew conducted MOB drill in front of Inspection Team.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2021 Resolved
Engine room wiring must be mounted and installed in a safe manner and enclosures must be used where apporpriate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2021
Resolution: Wiring in the engine room was mounted/installed/secured in a safer manner with use of plastic wraps and metal supports.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 14 April 2021 Resolved
Buoyant apparatus installed must be in accordance with manufacturers instructions. Identified the float free line feeding from the top. The float free line must feed from the bottom of the float free guide installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 22 April 2021
Resolution: The float free line was reconfigured from the bottom of the furling canister to the top as designed by manufacturer
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2021 Resolved
A vessel inspected under 46 CFR sub-chapter T must be standards, not covered under sub chapter T, however be maintained to acceptable standards to the OCMI under good marine practices. Identified the forward sections of the Port and starboard passenger bench type seating as loose and a hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 22 April 2021
Resolution: The bench type seating identified was refastened and secured to prevent injury aboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2021 Resolved
An adult life jacket must be provided for each person on board. Identified 6 KAPOK type I adult PFD’s in in serviceable condition and condemned. available serviceable PFDs on board are 44 adult PFDs. Provide PFDs in accordance with COI prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Condemned PFDs were removed and replaced. Vessel has the appropriate number of PFDs IAW the issued COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2021 Resolved
The number and type of life saving equipment stored must be labeled and marked clearly. Identified the PFD labels work and illegible. Re-stencil the adult and child PFD locations on the over head.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 22 April 2021
Resolution: PFD labeling was renewed for adult and child sized PFDs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2021 Resolved
Placards containing instructions for the donning and use of the life jackets on board must be posted in a conspicuous place, regularly accessible to the crew and passengers. Vessel has 2 types of PFD’s on board and no placard for the KAPOK type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 22 April 2021
Resolution: Donning instructions were posted in a common space to the crew and passengers.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 April 2021 Resolved
Vessel must be made available for inspection. Arrived at the vessel with numerous tripping hazards through out the deck and gear adrift throughout the vessel. Make the vessel inspection ready prior to the inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 22 April 2021
Resolution: Deck and passenger areas were cleaned and all gear adrift was stowed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 April 2021 Resolved
Rails and guards must be installed around the periphery of all decks accessible by the passengers or crew. On the starboard side ladder on the bow the hand railing is loose. Deck railing must be able to withstand 200lb point load. Re- fasten and secure railing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 22 April 2021
Resolution: Railing was removed and re-fastened to withstand greater than 200LBS at any point
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 April 2021 Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB in accordance with the FCC, 47 CFR 80. Identified the EPIRB hydrostatic release expired. Replace the hydro static release and mark with the appropriate expiration date prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: New EPIRB hydro-static release was purchased and installed. I personally marked the hydrostatic release, providing training and education to the mariner.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2020 Resolved
Submit repair plan for the clamp block on the PORT side aft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: 7. Clamp block replaced and refastened with galvanized steel carriage bolts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2020 Resolved
Submit repair plan in way of the rudder and keel where the top board in front of the rudder was removed
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: 6. At the keel where the rudder post protrudes though the keel,a section of wood was cut out and replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2020 Resolved
Make available for inspection the forepeak where the space is over run with living organisms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: Areas were cleaned out and made available for inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2020 Resolved
Submit a repair plan where day light was observed from the inside the vessel in the number 2 void in way of the chine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: 4. RCVD repair plan and approved, light was observed where the hull planks met the chine board. Filled with cotton and caulked satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2020 Resolved
Submit a repair plan for areas discussed where newly installed caulk was identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: 3. Area where caulk was identified was dried out and repaired appropriately. Gap between the hull planks and the chine board was filled with cotton and caulked over.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 23 September 2020 Resolved
Remove all "apparent" black water from void 3 and make the internal structures available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: Areas were cleaned out and made available for inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2020 Resolved
Remove all oily water substance from the machinery space and make the internal structures available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: Areas were cleaned out and made available for inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2020 Resolved
Submit a repair plan in way of the starboard side aft where a keel bolt was identified corroded and the wood over the bolt was wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 28 September 2020
Resolution: 8. STBD side keel bolt was replaced and caulked over on the starboard side.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2020 Resolved
Prove proper operation on the vessel's MDE
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2020
Resolved 7 April 2021
Resolution: Witnessed operations of the vessel's MDE underway during drills
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 May 2020 Resolved
Failure to correct deficiencies identified by the attending MI on the vessel's annual exam
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 7 April 2021
Resolution: Deficiencies issued corrected. O/O left the area during COVID-19 and was not available to make the vessel available for inspection
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 September 2019 Resolved
EPIRB Battery found expired 6/2018 on 09/2019. 46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 7 April 2021
Resolution: Inspected. New EPIRB Purchased
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 September 2019 Resolved
Vessel's representative does not keep or track EPIRB Maintanance IAW CFR. 46 CFR 185.728
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 7 April 2021
Resolution: O/O created pre-printed log books with a section to track and record this information
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 September 2019 Resolved
Excessive oil found in the engine room bilge. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 7 April 2021
Resolution: E.R. space re-inspected and inspected at the vessel's last DD exam. E.R. was free and clear of excessive oil and debris at the time of this inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 September 2018 Resolved
Trace wiring for sensor/alarm in engine compartment
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2018
Resolved 23 October 2018
Resolution: Wiring for sensors inthe E.R. compt. identified by the O/O
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 September 2018 Resolved
Make hatches on back deck watertight
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2018
Resolved 23 October 2018
Resolution: O/O removed the boxes/hatches on the aft deck and istalled rubber/ foam gasket material and rebolted the boxes/ hatches down over the deck openings.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 September 2018 Resolved
Program MMSI into radio- 47CFR80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2018
Resolved 7 November 2018
Resolution: Cleared outstanding def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 September 2018 Resolved
Replace 02 adult life jackets
Action required: 10 - Deficiency Rectified
Due 21 September 2018
Resolved 21 September 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2018 Resolved
Label emergency fuel shutoffs
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2018
Resolved 23 October 2018
Resolution: Obsrved E./ Remote F/O shut off valves labled. O/O stated he is planning on re-painting the cover where the e. fuel stops are and should be re-checked at the next site visit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2018 Resolved
Make preexisting installed bilge system operationally ready
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2018
Resolved 23 October 2018
Resolution: Observed bilge pump and operation. O/O demonstrated knowledge of use.
Lifesaving › Hand Flares › Expired
Issued 13 September 2017 Resolved
Replace 2 Flares that are expired and remove old flares from vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Resolution: Corrected on the spot
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 September 2017 Resolved
repair bilge alarm in aft compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Resolution: corrected on the spot (float switch was replaced)
Communications › Radio Communications › EPIRB
Issued 7 October 2016 Resolved
Replace EPIRB hydrostatic release.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 20 December 2016
Resolution: Operator installed new EPIRB hydrostatic release.
Engineering › Fuel Oil Service System › Valve
Issued 7 October 2016 Resolved
Replace aft fuel filter shutoff handle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 20 December 2016
Resolution: Aft fuel filter shutoff valve handle replaced and operational test conducted.
Lifesaving › Lifebuoys › Serviceable
Issued 7 October 2016 Resolved
Replace port lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 20 December 2016
Resolution: New lifering onboard vessel to replace old lifering.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 October 2016 Resolved
Renew deck hatch cover gasket material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 13 September 2017
Resolution: Gasket renewed
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 October 2016 Resolved
Attach all deck hatch covers to vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 20 December 2016
Resolution: All deck hatch covers were secured to the vessel by chain link.
Construction/Loadline › Hull › Transverse Frame
Issued 7 October 2016 Resolved
Submit repair proposal to address wasted bow space wood and cracked sister.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 10 August 2018
Resolution: noted satisfactory repairs during inspection.