Records from 1985 to 2006. Most recent: inspection, 21 August 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
21 August 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2754776
9 September 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1680464
7 December 2001
In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1076947
12 July 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1054370
4 June 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 48908
18 May 2000
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1436381
21 May 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1459508
14 April 1998
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1411679
21 May 1997
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1435930
30 April 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1102327
21 August 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1137917
29 May 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1084903
2 July 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 116414
26 June 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 881103
4 May 1995
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 862446
13 April 1995
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1371051
10 February 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1149387
22 November 1994
Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 861909
27 September 1994
Damage Survey · Examination of Repairs
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 869971
17 August 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 63149
14 June 1994
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018266
14 June 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325751
27 May 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 859536
28 May 1993
Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1379832
14 May 1993
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1467372
19 November 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 827320
30 June 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 20453
5 May 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 949270
19 April 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 920211
19 April 1991
Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1219940
12 April 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1224917
28 March 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 907231
9 May 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 918283
10 May 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 889527
4 May 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1201194
20 December 1988
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1032091
13 May 1988
Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888373
10 May 1988
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888527
16 November 1987
Administrative
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330435
23 October 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325194
1 July 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1031036
29 June 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1031034
24 March 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1019853
25 July 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324484
14 May 1986
Credit Drydock · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 992631
21 April 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 999946
31 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 980983
4 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 982067
Operations/Management › Drills/Instruction
Issued 26 September 2002
Resolved
Life jacket donning placard not posted. LEGACY COMPONENT DESC: Safety Orientation
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 19 November 2002
Resolution: Posted life jacket donning placard.
Lifesaving › Lifejacket/PFD (General)
Issued 26 September 2002
Resolved
Seperate adult/child life jackets and label as such. LEGACY COMPONENT DESC: Storage
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: Seperated children and adult life jackets.
Fire Fighting › Remote Fuel Shutoff
Issued 26 September 2002
Resolved
Label emergency fuel shut-offs and mount wrench for access to the valves.
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: Labeld fuel shut-offs and installed operating wrench.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 September 2002
Resolved
Label second deck with number of passengers permitted.
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: Labeld second deckas per stability letter with 24 passengers.
Electrical › Electric Generation Source (service)
Issued 26 September 2002
Resolved
Replace cover for generator resistors. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 9 October 2002
Resolved 7 October 2002
Resolution: Installed cover on generator resistors.
Electrical › Lighting (service)
Issued 26 September 2002
Resolved
Provide cover for flourescent light in engine room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 9 October 2002
Resolved 7 October 2002
Resolution: Installed cover on light in engine room.
Engineering › Electric Propulsion System
Issued 26 September 2002
Resolved
Provide new hangers for generator vent/include double hose clamps.
Condition: Unknown
Due 9 October 2002
Resolved 7 October 2002
Resolution: Installed new hangers and double hose clamps on generator vent.
Engineering › Bilge Water Management System
Issued 26 September 2002
Resolved
Double hose clamp all thru hull fittings. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 9 October 2002
Resolved 7 October 2002
Resolution: Installed double hose clamps on all thr-hull fittings.
Documentation › Logs/Records
Issued 26 September 2002
Resolved
Provide proof of payment of user fee.
Condition: Unknown
Due 9 October 2002
Resolved 7 October 2002
Resolution: Provide check and certified mail recepit for user fee.
Stability › Watertight Integrity
Issued 26 September 2002
Resolved
Make fore and aft hatches watertight and mount wrenches for access for and aft.
Condition: Improper/Lack of Maintenance
Due 9 October 2002
Resolved 7 October 2002
Resolution: Mounted wrenches and replaced gasket on hatches.
Engineering › Bilge Water Management System
Issued 26 September 2002
Resolved
Place proper labels on bilge alarms in pilot house. LEGACY COMPONENT DESC: Pump
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: Numbered bilge alarms in pilot house.
Lifesaving › Lifebuoys
Issued 26 September 2002
Resolved
Replace clip on ring buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 9 October 2002
Resolved 7 October 2002
Resolution: Installed proper clip on ring buoy.
Documentation › Logs/Records
Issued 26 September 2002
Resolved
Provide proof of master/mate and crew in proper testing program. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Due 9 October 2002
Resolved 19 November 2002
Resolution: Provided proof of all master/mates in drug program.
Operations/Management › Drills/Instruction › Fire
Issued 26 September 2002
Resolved
Conduct proper man overboard/fire drills.
Due 9 October 2002
Resolved 21 August 2006
Resolution: Discrepancy not resolved, COI not issued/ deactivated.
Electrical › Electric Generation Source (service)
Issued 26 September 2002
Resolved
Remount/remove electrical shore tie. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Due 9 October 2002
Resolved 7 October 2002
Resolution: Remounted electical shore tie.
Stability › Watertight Integrity
Issued 26 September 2002
Resolved
Make repairs to all leaks in #1 compartment.
Condition: Improper/Lack of Maintenance
Due 9 October 2002
Resolved 7 October 2002
Resolution: Repairs made to starboard side in # 1 comparment. Leaking seams were removed recaulked/resealed. No leaks were observed underway.
Electrical › Electrical Distribution System (service)
Issued 26 September 2002
Resolved
Label circuit breaker box in engine room. LEGACY COMPONENT DESC: Switchboard
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: All circuit breakers labeled.
Navigation › Piloting/Steering
Issued 26 September 2002
Resolved
Provide proper Light List/Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: Provided current light list/coast pilot.
Electrical › Electrical Distribution System (service)
Issued 26 September 2002
Resolved
Remove extension cord in forward compartment. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: Removed extension cord.
Documentation › Logs/Records
Issued 26 September 2002
Resolved
Provide all logs for pilothouse. LEGACY COMPONENT DESC: Logbook (official)
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 19 November 2002
Resolution: Updated all vessel logs.
Engineering › Bilge Water Management System
Issued 26 September 2002
Resolved
Install high level alarm in forward compartment. LEGACY COMPONENT DESC: Interface Detector
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: Installed and operated high level bilge alarm in forward compartment.
Electrical › Lighting (emergency)
Issued 26 September 2002
Resolved
Provide two hand held flash lights. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Placed in Improper Service
Due 9 October 2002
Resolved 7 October 2002
Resolution: Provided two operational flashlights
Engineering › Bilge Water Management System
Issued 26 September 2002
Resolved
Remove spigot valve on bilge main, stbd side. LEGACY COMPONENT DESC: Piping
Due 9 October 2002
Resolved 7 October 2002
Resolution: Removed spigot valve.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 9 September 2002
Resolved
Replace starboard shaft.
Due 19 November 2002
Resolved 21 August 2006
Resolution: Discrepancy not resolved, COI not issued/ deactivated.
Electrical › Electric Supply System (service) › Cable
Issued 9 September 2002
Resolved
Heat shrink electrical wiring to S/S powere take-off unit on port MDE.
Due 19 November 2002
Resolved 21 August 2006
Resolution: Discrepancy not resolved, COI not issued/ deactivated.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 September 2002
Resolved
Seal holes in main deck above #1 compartment.
Due 19 November 2002
Resolved 21 August 2006
Resolution: Discrepancy not resolved, COI not issued.
Deck/Cargo › Ballast › CBT
Issued 9 September 2002
Resolved
Remove rotted wood on forward main deck with new.
Due 19 November 2002
Resolved 21 August 2006
Resolution: Discrepancy not resolved, COI not issued.
Construction/Loadline
Issued 7 December 2001
Resolved
#1 & #2 COMPARTMENTS STARBOARD SIDE IN WAY OF FIRST 4 DECK FRAME BAYS, REMOVE NAILER AND EPLACE WITH BUTT BLOCKS AS EVIDENT BY PORT SIDE.
Condition: Unknown
Due 14 December 2001
Resolved 10 December 2001
Lifesaving
Issued 7 December 2001
Resolved
REPLACE WATER LIGHT BATTERY ON VESSEL'S RING LIFE BOUY.
Condition: Unknown
Due 14 December 2001
Resolved 10 December 2001
Navigation
Issued 7 December 2001
Resolved
REPLACE BULB ON VESSELS ANCHOR LIGHT.
Condition: Unknown
Due 14 December 2001
Resolved 10 December 2001
Lifesaving
Issued 18 May 2000
Resolved
PRIOR TO OPERATION WITH PASSENGERS, PROVIDE VESSEL FOR U/W EXAM.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Construction/Loadline
Issued 21 May 1997
Resolved
REPLACE FIRST BOTTOM PLANK PORTSIDE, INBOARD OF CHINE, IN WAY OF SECOND ANDTHIRD VOIDS. FRAMES TO BE EXAMINED BY A MARINE INSPECTOR, AFTER PLANK REMOVAL.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Accommodation/Occupational Safety
Issued 30 April 1997
Resolved
REPAIR AND DEMONSTRATE STBD TOILET. (FEMALE HEAD)
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Electrical
Issued 30 April 1997
Resolved
REPAIR PORTSIDE UPPER DECK ELECTRICAL OUTLET.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Accommodation/Occupational Safety
Issued 30 April 1997
Resolved
SECURE UPPER DECK WIRE MESH ON RAILS.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Lifesaving
Issued 30 April 1997
Resolved
PROVIDE NON CORROSION CLIP ON RING BUOY LIGHT LINE.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Lifesaving
Issued 30 April 1997
Resolved
PROVIDE 39 ADDITIONAL CG APPROVED TYPE I ADULT LIFE JACKETS PRIOR TO CARRYING MORE THAN 63 ADULTS.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Electrical
Issued 21 August 1996
Resolved
PROPERLY MOUNT PORTSIDE, UPPER DECK ELECTRICAL RECEPTICLE.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Lifesaving
Issued 21 August 1996
Resolved
REPAIR OR REPLACE RINGBUOY WATERLIGHT.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Accommodation/Occupational Safety
Issued 21 August 1996
Resolved
REPAIR OR REPLACE PORT TOILET AND DEMONSTRATE.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Construction/Loadline
Issued 29 May 1996
Resolved
DEMONSTRATE FIXED BILGE SYSTEM ON BOW AND AFT STEERING COMPARTMENTS.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 29 May 1996
Resolved
PROPERLY REPAIR STERN SAFETY RAILS.
Condition: Unknown
Due 28 June 1996
Resolved 26 June 1996
Lifesaving
Issued 4 May 1995
Resolved
PRIOR TO CARRYING MORE THAN 59 ADULTS, PROVIDE 43 ADDITIONAL USCG APPROVED TYPE I ADULT-SIZE LIFE PRESERVERS.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Engineering
Issued 4 May 1995
Resolved
PROVIDE LOW VENTILATION IN THE ENGINE ROOM AS REQUIRED BY 46 CFR 182.20-45 (c) & (d).
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Construction/Loadline
Issued 4 May 1995
Resolved
REPAIR THE BROKEN BILGE LINE TO AFT STEERING AND DEMONSTRATE PROPER BILGE SYSTEM OPERATION BY TESTING THE SYSTEM.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Construction/Loadline
Issued 13 April 1995
Resolved
REPLACED 23'7" OF PORT UPPER CHINE FROM STERN FWD DUE TO DAMAGE, WITH MAHOGANY PLANK AND FASTENED WITH 4" #6 MONEL RING NAILS. ALL GALVANIZED BOAT NAILS REMOVED WERE SAT.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
REPLACED 16'8" OF PORTSIDE UPPER SIDESHELL PLANK, ABOVE UPPER CHINE FROM STERN FWD DUE TO DAMAGE. REPLACED WITH MAHOGANY PLANK, FASTENED WITH 4" #6MONEL RING NAILS.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
PROVIDE A PROPER BILGE SYSTEM PER 46 CFR 182.25-5(b) WITH MINIMUM ONE INCH METALLIC LINE AND DISCHARGE VALVE (SKIN VALVE), TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
REPLACED 7'6" OF PORT LOWER PLANK BELOW LOWER CHINE 17'6" FWD OF STERN DUE TO DAMAGE, WITH MAHOGANY PLANK AND FASTENED WITH 4" #6 MONEL RING NAILS. ALL 4" GALVANIZED BOAT NAILS REMOVED WERE SAT.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
LEAKS IN FOLLOWING AREAS: 5TH COMPT. AFT BULKHEAD PORTSIDE OF KEEL. 3RD COMPT. PORT CHINE, 2ND FRAME. LEAKS SEALED NATURALLY BY SWELLING IN WATER,NO CAULKING APPLIED.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
INSTALLED MISSING 1/2" GALVANIZED CHINE BOLTS ON FRAME 4 & 5.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
REFASTENED GARBOARD PORT AND STBD SIDE FROM STEM TO STERN, REFASTENED STEM FROM WATERLINE TO GARBOARD PORT AND STBD SIDE, REFASTENED ENTIRE LOWER STERN BOARD. ALL WITH 4" #6 MONEL RING NAILS.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
REPLACED (3) STBD PLANKS AS FOLLOWS: 16'6" GARBOARD 10'5" AFT OF BOW, 14'9"1ST PLANK ABOVE GARBD 16' AFT OF BOW, 2ND PLANK ABOVE GARBD 20'6" AFT OF BOW, ALL PLANKS REPLACED WITH MAHOGANY & FASTENED WITH 4" #6 MONEL RING NAILS, DUE TO IMPROPER REPAIR USING TWO STEEL PLATES.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Documentation
Issued 13 April 1995
Resolved
PRIOR TO OPERATING THE VESSEL MORE THAN 1,000 FT FROM SHORE, PROVIDE A VALID FCC STATION LICENSE.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
REPLACE TWO GALVANIZED 3/8" BUTT BLOCK CARRIAGE BOLTS ON ONE BUTT BLOCK, PORTSIDE BOW COMPT. AND ONE BUTT BLOCK STBDSIDE BOW COMPT.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Construction/Loadline
Issued 13 April 1995
Resolved
REPLACED 1/2" GALVANIZED PORT RUDDER BLOCK BOLT.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Construction/Loadline
Issued 22 November 1994
Resolved
PRIOR TO CARRYING PASSENGERS (AFTER 30NOV94), COMPLETE A CREDIT DRYDOCK EXAMINATION TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR. (DRYDOCK DUE DATE EXTENDED TO 31MAR95 FOR WINTER LAY-UP, PER OWNER WRITTEN REQUEST)
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 27 September 1994
Resolved
REPLACE SECTION OF MISSING PIPING, AND REPAIR/REPLACE BROKEN VALVE ON FIRE MAIN OVERBOARD DISCHARGE LINE IN THE ENGINE ROOM, STARBOARD SIDE.
Condition: Unknown
Due 27 September 1994
Resolved 29 September 1994
Navigation
Issued 27 September 1994
Resolved
PROVE PROPER OPERATION OF THE STEERING SYSTEM, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 September 1994
Resolved 29 September 1994
Construction/Loadline
Issued 27 September 1994
Resolved
HOLE APPROXIMATELY 12 IN X 18 IN PORTSIDE AMIDSHIPS JUST ABOVE THE _x001C_ WATERLINE. HOLE APPROXIMATELY 4 IN X 6 IN PORTSIDE AT THE WATERLINE _x001C_ APPROXIMATELY 6 FT AFT OF THE LARGE HOLE.
Condition: Unknown
Due 27 September 1994
Resolved 29 September 1994
Construction/Loadline
Issued 27 September 1994
Resolved
PRIOR TO COMPLETION OF NEXT DRYDOCKING, MAKE PERMANENT REPAIRS WHERE THE TEMPORARY REPAIR ON THE PORT SIDE AMIDSHIPS AT THE WATERLINE WAS AFFECTED 27SEP94. (TWO DUTCHMAN PLACED IN BOTTOM-MOST PLANK OF DAMAGED AREA. VSL WASNOT HAULED AND THERFORE THIS PLANK COULD NOT BE PERMANENTLY REPAIRED.)
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Documentation
Issued 27 May 1994
Resolved
PRIOR TO OPERATING MORE THAN 1,000 FROM SHORE, PROVIDE A MASTER WITH A VALID FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994
Electrical
Issued 27 May 1994
Resolved
PROVE PROPER OPERATION OF THE AUXILIARY GENERATOR.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994
Electrical
Issued 28 May 1993
Resolved
REMOVE PORTABLE NON-MARINE TYPE BATTERY CHARGER IN ENGINEROOM.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Lifesaving
Issued 28 May 1993
Resolved
REPAIR OR RENEW # 2 BUOYANT APPARATUS (SCREWS LOOSE AND DELAMINATING).
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Documentation
Issued 28 May 1993
Resolved
PROVIVE A CURRENT FCC STATION LICENSE, ROUTE IS RESTRICTED TO NOT MORE THAN1000' FROM SHORE.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 28 May 1993
Resolved
PROPERLY SECURE OVERHEAD GAUGE BOARD IN ENGINEROOM.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Electrical
Issued 28 May 1993
Resolved
REMOVED DEAD END (CUT OFF) WIRES IN ENGINEROOM.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Navigation
Issued 5 May 1992
Resolved
PROVIDE A CURRENT COPY OF, OR APPLICABLE EXTRACT FROM, THE U. S. COAST GUARD LIGHT LIST.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Accommodation/Occupational Safety
Issued 5 May 1992
Resolved
REPAIR LOOSE STANCHION ON LIFERAIL, STARBOARD SIDE, BY THE AFT END OF THE RAIL OPENING. THE AREA WHERE IT BOLTS TO THE GUNNEL CAP APPEARS TO BE ROTTED.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Engineering
Issued 19 April 1991
Resolved
ENGINE COMPARTMENT, REPLACE PVC PIPING ON MDE COOLING WITH METALLIC_x001C_ PIPING.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Engineering
Issued 19 April 1991
Resolved
COLLISION COMPARTMENT BILGE VALVE FROZEN.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 13 May 1988
Resolved
PROVIDE TWO (2) ADDITIONAL ADULT TYPE I LIFEJACKETS. THE NUMBER OF ADULTS TO BE CARRIED ABOARD THE VESSEL IS TO BE NOT MORE THAN ONE-HUNDRED (100) PERSONS UNTIL CORRECTED.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Accommodation/Occupational Safety
Issued 13 May 1988
Resolved
PROVIDE WATER SERVICE TO THE TOILET SPACE WASH BASINS. THE VESSEL IS RESTRICTED TO NOT MORE THAN FORTY-NINE (49) PERSONS UNTIL CORRECTED.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Fire Fighting
Issued 13 May 1988
Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE AN ADDITIONAL FIFTY (50) FOOT LENGTH OF FIREHOSE ALONG WITH A NOZZLE.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Electrical
Issued 29 June 1987
Resolved
PLUG THE TWO MISSING KNOCKOUTS IN THE ELECTRICAL DISTRIBUTION PANEL IN WAY OF THE FORWARD ACCOMMODATION SPACE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987
Resolved
PROVIDE ELEVEN (11) TYPE I ADULT LIFE PRESERVERS. VESSEL IS LIMITED TO CARRIAGE OF 78 PERSONS ON COASTWISE ROUTE AND 91 PERSONS ON LAKE, BAYS AND SOUNDS ROUTE UNTIL COMPLETED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Deck/Cargo
Issued 29 June 1987
Resolved
REPAIR OR REMOVE THE ANCHOR WINDLASS.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Electrical
Issued 29 June 1987
Resolved
REMOVE ALL DEAD ENDED WIRING IN THE VESSEL. BOXES, WIRES ON FORWARD BULKHEADS OF TANK SPACE, ENGINEROOM, AND #4 VOID AFT OF ENGINEROOM ARE SPECIFICIALLY INCLUDED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Engineering
Issued 29 June 1987
Resolved
PROVIDE AND INSTALL CHECK VALVES IN ALL BILGE LINES PRIOR TO THE 1988 OPERATING SEASON.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 14 May 1986
Resolved
STENCIL THE VESSEL'S NAME ON ALL PFD'S.
Condition: Unknown
Due 14 May 1986
Resolved 14 May 1986
Lifesaving
Issued 14 May 1986
Resolved
STENCIL THE VESSEL'S NAME ON THE RING BUOY.
Condition: Unknown
Due 14 May 1986
Resolved 14 May 1986
Lifesaving
Issued 14 May 1986
Resolved
STENCIL THE BUOYANT APPARATUSES WITH THE VESSEL'S NAME.
Condition: Unknown
Due 14 May 1986
Resolved 14 May 1986
Engineering
Issued 4 April 1985
Resolved
REPAIR REACH ROD TO FORWARD COLLISION BULKHEAD SHUT-OFF VALVE AND PROVE PROPER OPERATION.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Engineering
Issued 4 April 1985
Resolved
E-3 PROVIDE GROUNDING STRAPS TO A COMMON GROUND FOR FUEL TANKS.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Engineering
Issued 4 April 1985
Resolved
REPAIR REACH ROD FOR FUEL TANK SHUT-OFF VALVES AND PROVE PROPER OPERATION.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985