CUMBERLAND STAR

CUMBERLAND STAR is a 1996 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in August 2025, along with 42 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 14 August 2025.

Built
1996
Last inspected
14 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 August 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3495
437088
Flag
UNITED STATES
Maury page id
psix-437088

Documentation record

Registered dimensions (L × B × D)64.6 ft × 18.0 ft × 3.3 ft
Registered tonnagegross 12 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOLIDCRAFT BOAT MFG · PARKERS LAKE, KY, UNITED STATES · built 1996
Hull materialAluminum
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationTri Hull
Hailing portMCCREARY COUNTY, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

14 August 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8209759
22 July 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7953128
26 February 2024 Deficiency Check · Construction Oversight
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7868154
29 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7780355
5 January 2023 Deficiency Check · Drydock Exam · In-Service Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7612465
27 September 2022 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7567118
9 August 2022 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7513812
30 July 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7272713
6 August 2020 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7020800
13 June 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6704632
4 December 2017 COI Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6317949
26 August 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6256269
17 August 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6244458
14 June 2016 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5906859

Deficiency record · 42

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 August 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. PORT engine compartment was witnessed with oil in the bilge. Owner shall ensure bilge is cleaned and free of oil and engine oil leak is repaired to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2025
Resolved 18 August 2025
Resolution: Replaced and fixed the oil filter, leak around the seal
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 July 2024 Resolved
Watertight integrity. (a) A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight:(3) A hatch on a vessel that operates only on protected waters. Vessel engine compartment hatch is allowing excessive water ingress into the bilges and engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 24 July 2024
Resolution: Leak has been fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2024 Resolved
Bilge piping system.(a) A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Port side not operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 24 July 2024
Resolution: Port side bilge is operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 July 2024 Resolved
Bilge high level alarms. (a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station. Port side not operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 24 July 2024
Resolution: Port side alarm is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2024 Resolved
Life jackets.(b) a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. 2 child life jackets not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 24 July 2024
Resolution: required amount of child life jackets are on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2024 Resolved
Stowage of life jackets. Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Child and adult life jackets not separated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 24 July 2024
Resolution: Child and adult life jackets are separated.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 July 2024 Resolved
Distress flares and smoke signals. (b) Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessels flares are expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 24 July 2024
Resolution: Vessels flares are good 09/2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 July 2024 Resolved
First-aid kits. A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10). Expired first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 6 August 2024
Resolution: Replaced First aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2024 Resolved
Batteries—general(b) Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Batteries container full of water.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 24 July 2024
Resolution: Proper maintence was performed on battery boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2024 Resolved
Cable and wiring requirements.(g) Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Multiple dead end wires in both engine compartments as well as exposed electrical connections.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 24 July 2024
Resolution: All wires have been installed correctly.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 August 2023 Resolved
Found port fuel tank to have what appeared to be temporary repairs on the bottom port corner. The same corner appeared to be saturated with fuel and a visible drop of fuel was noticed in the area of the temporary repair. This fuel tank will have to emptied, removed, repaired, and pressured tested. During transportation of the fuel tank at the shipyard the fuel tank was damaged beyond repair. Owner was granted permission to run both engines from the STBD fuel tank for the season and replace the port fuel tank in the off season.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 4 March 2024
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 January 2023 Resolved
Found port fuel tank to have what appeared to be temporary repairs on the bottom port corner. The same corner appeared to be saturated with fuel and a visible drop of fuel was noticed in the area of the temporary repair. This fuel tank will have to emptied, removed, repaired, and pressured tested. During transportation of the fuel tank at the shipyard the fuel tank was damaged beyond repair. Owner was granted permission to run both engines from the STBD fuel tank for the season and replace the port fuel tank in the off season.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 29 August 2023
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 January 2023 Resolved
Found the starboard side fuel tank cradle to be broken. Repair and/or replace.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 8 May 2023
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 January 2023 Resolved
Add operating instruction for Fixed engine room firefighting equipment.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 22 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 5 January 2023 Resolved
Remove oily water from engine compartment and clean oily residue.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 21 June 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 January 2023 Resolved
STBD bilge alarm was not operating at the lower operating station.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 10 May 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 August 2022 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2022
Resolved 5 October 2022
Resolution: Log entries have been created expanding the scope of the drills, to include dates/type drill along with scenarios for those drills.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 August 2022 Resolved
The owner or managing operator must provide satisfactory evidence (servicing report)of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 5 October 2022
Resolution: Received servicing reports for all of their fire fighting
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. To be completed at next drydock.
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 29 August 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 August 2022 Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2022
Resolved 27 September 2022
Resolution: MMC onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The Port out drive is leaking into the engine compartment.
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 29 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 August 2022 Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. The portable fire extinguisher located on the upper deck in the electrical box has not been serviced within the last year.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 27 September 2022
Resolution: Serviced and relocated fire extinguisher
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 August 2022 Resolved
Excess oil/water buildup in both engine compartments. In addition, the port engine compartment had oil residue covering most surfaces. Clean both compartments and pump out water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 29 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2022 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The original markings are faded and the number of child jackets was labelled 10 when they are required to have 12.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 8 May 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 August 2022 Resolved
A hatch exposed to the weather must be weather tight. Both the port and starboard engine hatches has deteriorated weather stripping. Replace weather stripping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2022
Resolved 27 September 2022
Resolution: Replaced weather stripping
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 August 2021 Resolved
Waterlight attached to Ring Life Bouy had a PFD style waterlight zip-tied to it. Provide proof of properly outfitted waterlight for RLB.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2021
Resolution: Day Light Ops only.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 August 2021 Resolved
Portable Fire extiguishers must be inspected monthly in accordance with NFPA 10 Chap 6. Maintain a log either paper or on maintainence tag.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 August 2021 Resolved
Vessel not equiped with high level bilge alarm with audible/visual indicator at the operating station. Additionally, a visual indicator must be provided to indicate when an automatic bilge pump is operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 August 2021 Resolved
Aspirin in First Aid kit is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 June 2019 Resolved
Replace worn line attached to ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 July 2019
Resolved 13 June 2019
Resolution: Vessel carrys more ring buoys than required by regulation.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2018 Resolved
Vessel could not provide Coast Guard approved first aid kit. Owner has fisrt aid kits onboard but they are not complete and Coast Guard Approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
Resolution: Received satisfactory photo from owner of a new first aid kit.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 May 2018 Resolved
Expired COD
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
Resolution: Received satisfactory documentation. Deficiency resolved.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 11 May 2018 Resolved
Vessel owner could not provide documenatation of abandon ship and man overboard drills and training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
Resolution: Received satisfactory documentation. Deficiency resolved.
Operations/Management › Drills/Instruction › Fire
Issued 4 December 2017 Resolved
Vessel could not provide proof of conducting firefighting drills and training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 11 June 2018
Resolution: Received satisfactory documentation. Deficiency resolved.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 17 August 2017 Resolved
Clean fuel/ oil on overhead near receptacle aft main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2017
Resolved 26 August 2017
Resolution: Received pictures of cleaned area.
Lifesaving › Lifebuoys › Stowage
Issued 17 August 2017 Resolved
Repair top deck port side lifebuoy mount (broken mounting screw).
Due 26 August 2017
Resolved 26 August 2017
Resolution: Received pictures of repaired mount.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 August 2017 Resolved
Prove proper operation of floating light attached to lifebuoy prior to carrying passengers at night.
Due 1 September 2017
Resolved 18 August 2017
Resolution: Batteries repalced, light operating properly.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 June 2016 Resolved
COD has been purchased - provide proof of purchase
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 19 July 2016
Resolution: Provided valid documentation.
Documentation › Certificates/Documents › FCC SSL
Issued 15 June 2016 Resolved
Provide FCC radio station license
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 19 July 2016
Resolution: Provided valid documentation
Documentation › Certificates/Documents/Licenses › Type Approval Certificate of Incinerator
Issued 15 June 2016 Resolved
Provide FCC Operators permit
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 July 2016
Resolution: Operator will show proof at next inspection
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 June 2016 Resolved
1 protable light would not light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 16 June 2016
Resolution: Corrected on the spot
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 15 June 2016 Resolved
fire extinguisher not in accessible location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 16 June 2016
Resolution: Moved fire extinguisher to accesible location - Pilot house; port side