JIUYANG FORTUNE is a 1995 freight ship. The Coast Guard has recorded 8 inspections since 2021, most recently in March 2024, along with 2 deficiencies and 1 operational control.
Records from 2021 to 2024. Most recent: inspection, 16 March 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it44219 - Convention (Subpart B), Gross Ton 13265 - Convention (Subpart B), Net Ton 13778 - Dead Weight, Ton 26863 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
16 March 2024PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7879313
22 March 2023Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7655133
7 March 2023In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7647287
30 November 2022PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601388
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2022Resolved
Fire extinguishing medium associated pressure components shall be designed to the satisfaction of the Administration. PSCO observed leaking condensation on pipes connected to low pressure CO2 vessel causing insulation to work improperly. Exposed electrical components on refrigeration compressor #1.
74SOLAS(97)5/1.12
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 March 2023
Resolution: Received satisfactory class report for the deficiency.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 August 2021Resolved
Oil fuel pipes, if damaged, would allow oil to escape from a storage tank having a capacity of 500L. PSCO discovered quick closing valve #OV302 (D.O. tank to F.O. purifier) blocked open with bolts. Vessel stated bolts were left in place after quick closing valves test had been conducted prior to entry. PSCO perfermed pneumatic tests of #O.V.302 numerous times with satisfactory results.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 August 2021
Resolved 17 August 2021