Records from 2014 to 2026. Most recent: inspection, 24 March 2026.
Inspection history · 22
24 March 2026
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8318901
5 February 2026
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8294974
14 May 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8135676
18 March 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7881310
8 February 2024
Examination of Repairs · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7842898
3 May 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7680627
4 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7443797
18 February 2022
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7392246
2 March 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7148942
10 February 2021
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7135503
23 April 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6934341
28 October 2019
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6845392
27 October 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6848975
21 October 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6839001
29 May 2019
Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6698666
2 May 2019
Construction Oversight · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6675037
3 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6405904
21 November 2017
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6314451
16 November 2017
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6295094
27 April 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6132972
7 March 2016
COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5828286
23 February 2016
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5827321
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2023
Resolved
All exposed wires shall be properly terminated. There were two exposed wires below the operating station console.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Received pictures of the deficiency being corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2023
Resolved
All electrical equipment and circuits must be clearly marked and identified. Distribution panel in the wheelhouse was not properly labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Received pictures of the deficiency being corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2023
Resolved
An exposed hazard, such as gears or rotating machinery must be protected by a cover, guard, or rail. The starboard engine did not have a guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Received pictures of the deficiencies being corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 May 2022
Resolved
Bilge pump found to be disconnected and inoperable. Repair bilge pump to ensure suction from required space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2022
Resolved 9 May 2022
Resolution: Vessel POC installed new bilge manifold.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 4 May 2022
Resolved
Life floats found to be stored together without required separation between each float. Provide means of separation between each life float.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 9 May 2022
Resolution: POC installed wooden separation between life floats
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 May 2022
Resolved
Vessel DSC capable VHF radio found to be installed without GPS data available. Program DSC VHF radio with GPS data.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2022
Resolution: POC installed new DSC VHF radio programmed with GPS position and MMSI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 May 2022
Resolved
Hydraulic lines on multiple bulkhead penetrations found to be wasted. Replace wasted components IAW manufacturer instruction.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2022
Resolved 15 June 2022
Resolution: Installed new hydraulic lines.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 May 2022
Resolved
Generator lagging found to be oil soaked. Provide clean, dry lagging for required area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 9 May 2022
Resolution: Oil saturation found to be primarily on the outside of lagging. POC cleaned lagging inside and out to remove oil saturation.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 March 2021
Resolved
INSTALL NEW PAINTER FOR LIFE FLOATS AND PROPERLY ATTACH PAINTER AND WEAK LINK TO THE VESSEL. REMOVE DETERIORATED WOOD AND ATTACH DIRECTLY TO VESSEL.
Action required: 705 - Other - as specified
Resolved 2 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 March 2021
Resolved
ENSURE VESSEL NAME IS MARKED OR PAINTED ON LIFE FLOAT PADDLES.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2021
Resolved
ENSURE CORROSION RESISTANT NOZZLES ARE INSTALLED ON EACH HOSE USED FOR FIRE FIGHTING. ( FIRE PUMP / BAIT PUMPS )
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 March 2021
Resolved
PROVIDE PROOF OF EPIRB REGISTRATION STICKER
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2021
Resolved
PROVIDE ASTS CURRENT YEAR ENROLLMENT FORM
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 February 2021
Resolved
Vessel must complete a check-ride for credit drydock, prior to carraige of passengers. Vessel authorized to transit to San Diego COTP Zone to complete check-ride.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2021
Resolved 17 March 2021
Resolution: Completed
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 April 2020
Resolved
ENSURE WATERTIGHT BULKHEAD PENETRATIONS AFT OF COLLISION BULKHEAD ARE MADE WATERTIGHT.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 10 June 2020
Resolution: Proof of watertight repair received
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 April 2020
Resolved
CLEAN OUT TOP PORTION OF GALLEY EXHAUST VENTILATION DUCTING TO ELIMINATE THE FIRE HAZARD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 10 June 2020
Resolution: clean out and verified
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 April 2020
Resolved
MAKE PERMANENT REPAIRS TO DECK SUPPORT IN ACCOMMODATION SPACE STBD SIDE TO MINIMIZE HAZARDS TO PERSONNEL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 10 June 2020
Resolution: proof of repairs provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2020
Resolved
EPLACE 02 CONDEMDED ADULT LIFEJACKETS AND REPLACE RETROREFLECTIVE TAPE ON 11 EXISTING LIFEJACKETS, REDUCE PASSENGER COUNT BY 13 (64 MAX) UNTIL CLEARED.
Action required: 705 - Other - as specified
Resolved 10 June 2020
Resolution: new lifejackets provided
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 April 2020
Resolved
NSTALL MMSI AND GPS INPUT INTO VESSELS VHF-DSC RADIO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 10 June 2020
Resolution: inputs made
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 23 April 2020
Resolved
INSTALL BELT SAFETY GUARD ON STARBOARD MAIN ENGINE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 10 June 2020
Resolution: guard installed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 April 2020
Resolved
INSTALL SPACERS TO SEPARATE LIFE FLOATS STOWED IN TIERS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 10 June 2020
Resolution: spacers installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2019
Resolved
Make Starboard Marine Gear Transmission repairs to manufactures specification. Provide report and conduct sea trials prior to taking passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2019
Resolution: Conducted sea trials with rebuilt gear installed, All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 4 September 2019
Resolved
Secure port side deck railing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 4 October 2019
Resolution: Received photo of refastened deck railing.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 May 2019
Resolved
Haul-out vessel to repair numerous leaks in the #8 and #9 (lazarette) compartments. Vessel is making water in both compartments.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 August 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 May 2019
Resolved
Conduct sea trial and drills after vessel hauls-out and completes repairs.
Action required: 60 - Rectify deficiencies prior to movement
Due 5 September 2019
Resolved 4 September 2019
Resolution: Sea trials and underway drills were preformed satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 May 2019
Resolved
Provide fire pump with nozzle.
Action required: 60 - Rectify deficiencies prior to movement
Due 5 September 2019
Resolved 4 September 2019
Resolution: Fire nozzle was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2019
Resolved
Properly label life jacket stowage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 4 September 2019
Resolution: Life jacket storage was labeled.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 May 2019
Resolved
Repair inoperable bilge alarm in the #8 void.
Action required: 60 - Rectify deficiencies prior to movement
Due 5 September 2019
Resolved 4 September 2019
Resolution: Bilge alarm was repaired and functioned properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 May 2019
Resolved
Prove operation of fire boy system override and manual pull cable.
Action required: 60 - Rectify deficiencies prior to movement
Due 5 September 2019
Resolved 4 September 2019
Resolution: Fireboy system shutdown and override functioned properly. Pull cable was replaced by service technician.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 2 May 2019
Resolved
Label bilge alarm panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 4 September 2019
Resolution: Bilge alarm panel was labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 May 2019
Resolved
Make permanent repairs to patched generator exhaust pipe in lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 4 October 2019
Resolution: Exhaust hose was repaired with flexible exhaust rated hose.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 May 2019
Resolved
Replace plastic fuel tank sight glass with heat resistant material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 4 October 2019
Resolution: Plastic sight indicator was replaced with tubular sight glass.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 May 2018
Resolved
Repair exhaust lagging on port main engine
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2018
Resolved 8 May 2018
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 3 May 2018
Resolved
Properly repair fuel fill'supply piping on portside tank
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2018
Resolved 8 May 2018
Resolution: piping was repaired
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 3 May 2018
Resolved
Properly repair fuel fill'supply piping on Starboard tank
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 8 May 2018
Resolution: Piping was repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2018
Resolved
Secure port and stbd hand rails.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2018
Resolved 8 May 2018
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 May 2018
Resolved
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2018
Resolved 8 May 2018
Engineering › Shafting/Propeller Arrangements › Thrust Shaft
Issued 22 November 2017
Resolved
Replace damaged shaft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2017
Stability › Unintentional Flooding › General
Issued 23 February 2016
Resolved
Shaft sheared in half.
Condition: Design Flaw
Due 15 March 2016
Resolved 9 March 2016
Resolution: New shaft installed; proper installation witnessed during annual inspection.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 23 February 2016
Resolved
Shaft sheared in half while underway
Due 9 March 2016
Resolved 9 March 2016
Resolution: Installed new shaft; proper installation witnessed during annual inspection.