THE SENATOR

THE SENATOR is a 1959 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in September 2025, along with 38 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 25 September 2025.

Built
1959
Last inspected
25 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY2616
Flag
UNITED STATES
Maury page id
psix-43718

Documentation record

Registered dimensions (L × B × D)90.8 ft × 35.4 ft × 9.3 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)90.8 ft × 35.4 ft × 9.3 ft
ITC tonnagegross 230 / net 76
BuilderSTURGEON BAY SHIPBUILDING · STURGEON, WI, UNITED STATES · built 1959
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAINT IGNACE, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
230 - Convention (Subpart B), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
76 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 29

25 September 2025 Annual Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8240594
7 January 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8060527
17 December 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8037152
2 July 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7966502
23 May 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7917984
27 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7746460
7 October 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7573609
1 August 2022 COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7504738
4 April 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7433442
3 January 2022 Deficiency Check · Plan Review "T" Boat · In-Service Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7379893
21 October 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7337543
10 February 2021 Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7138594
27 October 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7084768
6 January 2020 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6883608
4 November 2019 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6848969
30 October 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6858944
20 November 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619778
14 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6540261
12 June 2018 COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6436768
24 May 2018 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6423436
10 May 2018 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6411128
20 September 2017 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6274473
19 October 2016 In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6029460
5 October 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6017416
29 September 2016 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6015375
22 September 2016 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6015044
21 March 2016 Plan Review "T" Boat · In-Service Inspection · Construction Oversight · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5837951
17 February 2016 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5849131
6 January 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5792891

Deficiency record · 38

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 December 2024 Resolved
Vessels hot water heating auxiliary boiler has been replaced with new unit of same design and manufacturer. Boiler is prohibited from use until installation inspection, hydrostatic testing and the witnessing of all safety shutdown devices is completed.
Action required: 705 - Other - as specified
Due 17 December 2024
Resolved 30 December 2024
Resolution: Witnessed satisfactory hydrostatic test at 70 deg F to 40PSIG just over 125%MAWP. Internal visual inspection and safety function checks were completed by certified technician, all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 May 2024 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Vessel owner/operator failed to complete or provide record of completion of required inspections and/or maintenance of and fixed fire suppression system. 46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2024
Resolution: Fire service technician attended vessel and conducted inspection/servicing of equipment.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 May 2024 Resolved
The owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Inspection and testing of all smoke and fire detection systems, including sensors and alarms. Vessel owner/operator failed to complete or provide record of completion of required inspections and/or maintenance of the fire detection system. 46 CFR 176.810(a)(7)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2024
Resolution: Fire service technician attended vessel and conducted inspection/servicing of equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2022 Resolved
Maindeck port side RLB lifeline is deteriorated. RLB must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 11 August 2022
Resolution: replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 August 2022 Resolved
Engineroom bilges have rags & debris, all other bilges have excessive dirt & debris, all require cleaning.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 11 August 2022
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 August 2022 Resolved
Anchor stock bent making anchor unusable/ineffective. Must be repaired/replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 11 August 2022
Resolution: corrected.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 October 2021 Resolved
EPIRB battery is expired. Service EPIRB or replace with new unit. ** Vessel is limited to NMT 3 NM from land until deficiency is corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 25 October 2021
Resolution: replaced with new EPIRB.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 October 2021 Resolved
Port rudder packing leaking. Monitor and continue with approved maintenance practices. If leak worsens, OCMI notification is required. Packing must be replaced no later than at next dry-docking.
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 4 April 2022
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 February 2021 Resolved
Based on reports from the CGC BISCAYNE BAY, THE SENATOR was observed operating in 6-10" of Plate/Rubble ice on a transit from St. Ignace, MI to Mackinac Island, [name withheld] becoming beset by the ice, THE SENATOR had to be assisted by the Coast Guard ice breaker to free them. Based on previous history of damage to this vessel while being operated in ice and reports of the conditions that day, the Coast Guard suspects the possibility of damage to hull plating or structural members that may affect the sea worthiness of this vessel. Prior to the vessel's movement, Coast Guard Marine Inspectors will conduct an internal structural examination, and based on those findings, may require the vessel to be drydocked or taken out of service to assess the extent of any damage found, and to effect any necessary repairs in accordance with 46 CFR 176.600(d). You are reminded, that in accordance with 46 CFR 176.700(a), repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 February 2021
Resolved 5 March 2021
Resolution: Conducted ISE.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 10 February 2021 Resolved
Vessel has sustained structural fractures at the swosh bulkhead vertical support stiffeners in voids 3 and 4, and on the wing overhead transverse frames in voids 3, 4, & in the engine room on the starboard side. Submit a repair proposal to effect permanent repairs to damaged areas. If owners desire to operate prior to permanent repairs, submit proposed interim operating procedures which include loading documentation and a monitoring plan. Meticulous loading logs shall be maintained for all deck cargo transits. Include cargo weights and some form of mapping of the distribution of cargo on deck. Each trip record must be signed by the Master attesting to the accuracy of the record. All transits must be in full compliance with the vessels issued stability letter. Proposal must also include a plan for the company to monitor known damage via weekly inspections and document the findings. Company loading documentation and documented inspection results will be reviewed by Coast Guard Marine Inspectors at follow-up inspections. Any further degradation shall be reported immediately to the [name withheld].
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 4 April 2022
Resolution: repair plan complied with, all repairs verified complete.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 February 2021 Resolved
Electrical shore tie cable has a temporary splice made and is kinked. Replace shore tie cable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 6 April 2021
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 February 2021 Resolved
Lazarette hatch cover T-handle is broken and makes hatch not watertight. Repair/replace T-handle and make hatch serviceable to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 6 March 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 October 2020 Resolved
Each lifering must have the vessel's name marked clearly in legible block capital letters. The Starboard side fwd lifering does not have the name legibly on it.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 5 November 2020
Resolution: Corrected
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 October 2020 Resolved
Rudder packing is leaking and needs maintenance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 5 November 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 27 October 2020 Resolved
Escape hatch from the engine room and ladder below passenger cabin must be labeled with "EMERGENCY EXIT, KEEP CLEAR" in 2 inch letters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 5 November 2020
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 October 2020 Resolved
Vessel needs four more distress signals based on route.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 5 November 2020
Resolution: Corrected.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 October 2020 Resolved
When Class 1 materials are being loaded, handled, or unloaded on a vessel, the vessel must exhibit the following signals: By day, flag “B” (Bravo) of the international code of signals; and By night, an all-round fixed red light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 15 December 2020
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 October 2019 Resolved
Fire stations do not have spanner wrenches, install spanner wrenches at each fire station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2019
Resolved 6 January 2020
Resolution: installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019 Resolved
All batteries must be properly chocked to prevent shifting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2019
Resolved 6 January 2020
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 October 2019 Resolved
Replace dilapidated pfd.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 October 2019
Resolved 30 October 2019
Resolution: replaced prior to my departure.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018 Resolved
The vessel is currently broadcasting (1) Improper Call Sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2018
Resolved 1 May 2019
Resolution: Received notification of AIS broadcasting correction from vessel owner. Verified no errors in VIVS.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2018 Resolved
Replace 3 child size PFDs, prior to carrying more than 120 adults and more than 12 children.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2018
Resolved 13 June 2018
Resolution: Owner replaced and labeled, per photos and master statement.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 12 June 2018 Resolved
Provide Hazmat Employee Training certificates for master and crew prior to carrying hazardous materials in cargo
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 July 2018
Resolved 2 August 2018
Resolution: Sighted satisfactory crew training documentation.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 12 June 2018 Resolved
Removeable gates/deck railing at bow loading area not in use while underway, master believed it was not needed when passengers not aboard. Corrected during inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 June 2018
Resolved 12 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2018 Resolved
Improper size portable fire extinguishers has been substituted during recent servicing/inspection by servicing company. Required correction prior to operation, completed during inspection, master was counseled on ensuring proper fire extinguishers are always aboard as per the COI.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 12 June 2018
Resolved 12 June 2018
Construction/Loadline › Hull › Bottom Plating
Issued 10 May 2018 Resolved
Complete temporary repairs to lazarette hull plate fracture per approved repair plan.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 May 2018
Resolved 10 May 2018
Resolution: completed
Construction/Loadline › Hull › Bottom Plating
Issued 10 May 2018 Resolved
Complete permanent repairs to lazarette hull plate fracture.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 18 May 2018
Navigation › Piloting/Steering › Marine Charts
Issued 20 September 2017 Resolved
Replace outdated nav rules, nautical chart, light list and coast pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 13 October 2017
Resolution: replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 20 September 2017 Resolved
Post operating instructions for fixed E/R extinguishing systems at control station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 13 October 2017
Resolution: posted.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 September 2017 Resolved
Make RLB strobe light operational.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 20 September 2017
Resolution: Corrected prior to my deaprture from vessel.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 22 September 2016 Resolved
Post EP's at operating station
Condition: Improper Installation
Due 22 October 2016
Resolved 5 October 2016
Resolution: Instructions placed at operating station.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 22 September 2016 Resolved
Portable fire extinguishers need anti-chafe material between extingishers and mounting bracket to prevent continued wear/corrosion.
Due 22 October 2016
Resolved 5 October 2016
Resolution: Anti-chafe material installed.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 September 2016 Resolved
EPIRB monthly testing must be logged.
Due 22 October 2016
Resolved 5 October 2016
Resolution: Monthly tests properly logged.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 22 September 2016 Resolved
Main deck escape hatch for engineroom needs to be re-stenciled.
Due 22 October 2016
Resolved 5 October 2016
Resolution: Escape route properly marked.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 September 2016 Resolved
Mark upper deck with maximum passengers allowed per stability ltr.
Condition: Improper Installation
Due 22 October 2016
Resolved 5 October 2016
Resolution: Upper deck properly marked.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 September 2016 Resolved
Flexible sections of fuel fill piping must be properly bonded to prevent static electricity build up.
Due 22 October 2016
Resolved 5 October 2016
Resolution: Bonding properly installed.
Engineering › Pressure Vessel › Marking and Stamping
Issued 22 September 2016 Resolved
Mark boiler with reduced MAWP at 30 psi for water per 46CFR53.01-10(b)(2).
Due 22 October 2016
Resolved 19 October 2016
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 22 September 2016 Resolved
Make boiler available for examination and 1.25 hydro test in presence of Marine Inspector.
Due 22 October 2016
Resolved 19 October 2016
Resolution: Witnessed hydrostatic test at 39PSGI and 70 deg F.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.