MAURY USCG vessel records Sign in
← All vessels

LE VOYAGEUR

LE VOYAGEUR is a 1959 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1984, most recently in September 2025, along with 52 deficiencies and 2 casualty investigations between 2022 and 2025.

Records from 1984 to 2025. Most recent: inspection, 7 September 2025.

Built
1959
Last inspected
7 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WL2690
Flag
UNITED STATES
367366950
Maury page id
psix-43719

Inspections, by type

…with no type recorded8
Years with a record 39 calendar years (1984–2025)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft
Registered tonnagegross 70 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · STURGEON BAY, WI, UNITED STATES · built 1959
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAULT STE MARIE, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WL2690MMSI 367366950 · active · compulsorily equipped · granted 7 July 2018, expires 28 July 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

7 September 2025 Internal Structural Exam · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8228572
6 September 2025 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8229733
23 September 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8008053
2 October 2023 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7807410
3 May 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7686192
13 October 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7576603
24 June 2022 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7486068
20 June 2022 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7482309
15 October 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7333265
28 September 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7321986
11 May 2021 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7194070
4 November 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7089395
6 October 2020 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7066581
15 October 2019 Deficiency Check · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6834988
10 October 2019 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6831666
17 October 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6563084
18 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6543388
7 May 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6408755
3 October 2017 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6301672
12 October 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6018114
25 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5862033
28 September 2015 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5730754
14 October 2014 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5005417
6 October 2014 DAPI Audit · Drydock Extension · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5000207
18 May 2012 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4315092
14 October 2010 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3900079
15 October 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3345325
18 October 2007 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3086231
18 October 2006 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2803574
14 October 2005 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2516699
16 May 2005 Administrative Inspection
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2359489
14 October 2004 Hull Examination · Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2220959
1 October 2004 Damage Survey
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2213170
1 October 2004 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2240237
28 June 2004 Administrative Inspection
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2113320
9 June 2004 Construction Oversight
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2093257
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1976896
24 October 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1935268
17 October 2002 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1691419
29 May 2002 Excursion Permit
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1622564
17 May 2002 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1617881
16 October 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1423658
16 October 2000 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1425024
16 June 2000 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1423407
19 October 1999 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1430757
1 June 1999 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1378707
30 October 1998 Hull Examination · Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1452440
17 October 1997 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 779571
15 May 1997 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1090382
19 November 1996 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 869100
17 October 1996 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 845858
10 October 1995 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 880931
17 October 1994 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1178498
9 May 1994 Re-Inspection · Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 858835
7 May 1993 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1145142
7 May 1992 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 948668
8 May 1991 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 922003
7 May 1990 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1219396
8 May 1989 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 900509
26 April 1989 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1040028
19 August 1988 Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1347142
12 July 1988 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 902122
30 June 1988 Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1041424
20 June 1988 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 895448
10 May 1988 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1206880
7 May 1987 Re-Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1325970
8 May 1986 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1302514
21 May 1985 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1291734
17 October 1984 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1282271

Deficiency record · 52

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 October 2023 Resolved
Found flares expired.
Action required: 10 - Deficiency Rectified
Due 2 October 2023
Resolved 28 October 2023
Resolution: Flares added.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 June 2022 Resolved
Vessel grounded in the St Marys River while transiting back to the Soo Locks conducting a tour with 19 POB on board. Assess damage, submit repair proposal to OCMI, repair IAW approved plan, demonstrate proper operation prior to carriage of passengers. 46 CFR 176.600(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 28 September 2021 Resolved
Forepeak has scale that has accumulated in the bilge that needs to be removed. Scale is a threat to clog bilge suction and possibly prevent the space from being dewatered.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 15 October 2021
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 28 September 2021 Resolved
Electronic charts, which are used as the vessel's primary source of navigation information, need to be updated and current.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 15 October 2021
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 6 October 2020 Resolved
Port side aft freeing port is not functional. Make freeing port operational again.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 4 November 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 October 2020 Resolved
Replace missing bilge suction screen in the #2 void.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 4 November 2020
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 October 2020 Resolved
Vessel needs additional PFD for deckhand to wear during drills and emergencies while near or over the water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 4 November 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 October 2020 Resolved
Generator has a loose hose clamp on coolant line and needs an additional hose clamp to meet the double hose clamping requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 4 November 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 October 2019 Resolved
Make clogged strainer in the sewage holding tank void bilge serviceable to the satisfaction of the attending MI. 46 CFR 182.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2019
Resolved 15 October 2019
Resolution: Bilge Suction strainer was cleaned and revamped.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 October 2019 Resolved
Make vessel radios compliant with The Great lakes Radio Agreement inspection. 46 CFR 184.502
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 21 October 2019
Resolution: Received copy of Great Lakes inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 October 2019 Resolved
Configure navigation lights IAW the Inland Navigation Rules. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 6 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 October 2019 Resolved
Label watertight container for distress signals with "DISTRESS SIGNALS" 46 CFR 185.614
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 6 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 October 2019 Resolved
Replace expired float light battery. 46 CFR 185.726(d)
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 6 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 October 2019 Resolved
Replace missing stickers for vessel name on Life Ring Buoy hanging on port side of pilot house. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 6 October 2020
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 10 October 2019 Resolved
Replace missing hardware on the bases of 5 bench seats on the upper deck. 46 CFR 177.820(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 11 May 2021
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 October 2019 Resolved
Remove waste receptacles in heads and in pilot house that are not constructed of non-combustible materials. 46 CFR 177.405(f)
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 6 October 2020
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 10 October 2019 Resolved
Repair leaks in sewage void on stbd side sewage piping. 46 CFR 176.818
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 15 October 2019
Resolution: Leak repaired
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 October 2019 Resolved
Repair cracked stbd aft window. 46 CFR 177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 11 May 2021
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 October 2019 Resolved
Replace missing lid on generator battery box. 46 CFR 183.350(e)
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 6 October 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 18 September 2018 Resolved
The vessel is currently broadcasting (1) Zero Length and Beam, (2) Zero Draft, (2) No Ship type. The Ship should be 60 per the US official Encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 28 October 2019
Resolution: AIS def was corrected.
Communications › Internal Communications System › Sound-powered Telephone
Issued 3 October 2017 Resolved
Make emergency steering flat 2-way communications phone operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 7 May 2018
Resolution: repaired.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 3 October 2017 Resolved
Replace main deck forward PFE cracked discharge horn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 7 May 2018
Resolution: replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 3 October 2017 Resolved
Properly mount pilothouse PFE (mounting bracket bent & unuseable)
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 7 May 2018
Resolution: mounted.
Construction/Loadline › Structures › Superstructure
Issued 3 October 2017 Resolved
Pilothouse forward stbd window must be replaced - does not allow adequate visibility.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 7 May 2018
Resolution: replaced.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 October 2016 Resolved
Update U.S. Light List for current NTM update.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 28 October 2016
Resolution: Sighted updated light list.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 12 October 2016 Resolved
Update Navigation Rules
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 28 October 2016
Resolution: Sighted updated Nav Rules.
Documentation › Markings/Placards › Warning Signs
Issued 12 October 2016 Resolved
Properly mark emergency exit in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 28 October 2016
Resolution: Properly marked.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 12 October 2016 Resolved
Post emergency instructions at the operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 28 October 2016
Resolution: EP's properly posted at operating station.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 12 October 2016 Resolved
Replace plastic trash cans with non-combustible trash cans.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 28 October 2016
Resolution: Sighted order form for both vessels waste receptacles. Will attend in spring to verify they've been installed and non-combustible trash cans are removed or properly labeled for recycling only.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 October 2015 Resolved
New wiring for bilge alarms is not supported by metal brackets
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2015
Resolved 25 January 2016
Resolution: metal bracket installed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 6 October 2015 Resolved
Charts not corrected up to date. 2004 chart with no corrections
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2015
Resolved 25 April 2016
Resolution: purchased updated charts
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 6 October 2015 Resolved
Need current copy of navigation rules
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2015
Resolved 25 April 2016
Resolution: purchased updated navigation rules
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 October 2015 Resolved
Expired medication in first aid kit
Action required: 705 - Other - as specified
Due 20 October 2015
Resolved 25 April 2016
Resolution: replaced expired medication.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 6 October 2014 Resolved
Provide overcurrent protection for small gauge wires on main engine cranking motor positive terminal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 November 2014
Resolved 19 May 2015
Resolution: Overcurrent protection was provided.
Electrical › Electrical Distribution System (service) › Switch
Issued 6 October 2014 Resolved
Provide means of disconnection for positive wires on cranking batteries for main engine and generator drive engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 November 2014
Resolved 12 May 2015
Resolution: Means of disconnecting wires were provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 October 2014 Resolved
Provide metallic supports to keep main engine cranking motor wires as high as practicable in below the deck plates and engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 November 2014
Resolved 12 May 2015
Resolution: Metallic supports were provided.
Electrical › Electrical Distribution System (service) › Cable
Issued 6 October 2014 Resolved
Provide metallic supports for electrical wiring and cables in engineroom access landing area.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 November 2014
Resolved 12 May 2015
Resolution: Metal supports were provided.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 6 October 2014 Resolved
30# CO2 cylinder in semi-portable CO2 unit in engineroom access area is over due for the mandatory 12 year hydrostatic testing.
Condition: Improper/Lack of Maintenance
Due 6 October 2014
Resolved 6 October 2014
Resolution: Equipment not required by regulation was removed from vessel. Corrected during inspection.
Documentation › Certificates/Documents › Stability Letter
Issued 6 October 2014 Resolved
Stability letter and addendum was not posted in wheelhouse, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 6 October 2014
Resolved 6 October 2014
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 6 October 2014 Resolved
Emergency radio broadcast instruction placard not posted in wheelhouse, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 6 October 2014
Resolved 6 October 2014
Engineering › Steering Gear System › Rudder Bearing
Issued 15 October 2008 Resolved
Provide repairs to steering packing. Packing leaks and flange moves. Repair as per 46 CFR 176.814.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 17 October 2008
Resolution: Shaft packing adjusted and proper observation observed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 October 2004 Resolved
Install bilge alarm in compartment that has transducer for fathometer. Ref: 46CFR182.530 through hull fitting.
Condition: Unknown
Due 1 May 2005
Resolved 2 May 2005
Lifesaving
Issued 16 October 2001 Resolved
Conduct a fire and man-overboard drill prior to carrying passengers and prior to the compliance date.
Condition: Unknown
Due 15 May 2002
Resolved 30 April 2002
Documentation
Issued 16 October 2001 Resolved
Post emergency broadcast placard prior to the compliance date.
Condition: Unknown
Due 15 May 2002
Resolved 30 April 2002
Lifesaving
Issued 16 October 2001 Resolved
Mark lifejacket stowage lockers on second deck prior to carrying passengersand prior to the compliance date.
Condition: Unknown
Due 15 May 2002
Resolved 30 April 2002
Lifesaving
Issued 16 October 2000 Resolved
Clean retro-reflective tape on all unicelluar lifejackets prior to the compliance date.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Lifesaving
Issued 16 October 2000 Resolved
PROVIDE 3 HAND RED FLARES PRIOR TO CARRYING PASSENGERS AND PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Fire Fighting
Issued 19 October 1999 Resolved
Provide copy of service report showing protable fire extinguishers have been hydro-tested as per NFPA 10 prior to the compliance date.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Lifesaving
Issued 30 October 1998 Resolved
Provide properly marked container and distress signals prior to the compliance date and prior to carrying passengers.
Condition: Unknown
Due 30 October 1998
Resolved 30 October 1998
Unknown
Issued 17 October 1996 Resolved
Provide durable VHF placard at radiotelephone installation in accordance with 46 CFR 121.506.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Fire Fighting
Issued 17 October 1996 Resolved
Hydro test fixed CO2 system cylinder, and provide documentation of test to [name withheld].
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Fire Fighting
Issued 8 May 1991 Resolved
Provide portable fire/bilge pump in accordance with 46 CFR 181.10-5.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991

Casualty record · 2

24 June 2022Routine · role: Involved in a Marine Casualty · activity 7486068
6 September 2025Routine · role: Involved in a Marine Casualty · activity 8229733
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record