MAURY USCG vessel records Sign in
← All vessels

CAPT. BUNTING

CAPT. BUNTING is a 1959 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 1985, most recently in December 1996, along with 30 deficiencies.

Records from 1985 to 1996. Most recent: inspection, 3 December 1996.

Built
1959
Last inspected
3 December 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-43721

Inspections, by type

…with no type recorded2
Years with a record 12 calendar years (1985–1996)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Net Ton
49 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WL7169MMSI not assigned · expired · compulsorily equipped · granted 5 August 1996, cancelled 7 October 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

3 December 1996 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1186243
24 September 1996 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1413053
13 March 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1404099
21 July 1995 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360181
9 March 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1145305
19 June 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 220861
30 March 1994 Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1170127
7 March 1994 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1439478
23 February 1993 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1147583
23 February 1993 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1148864
27 February 1992 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1270988
16 October 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1248745
22 May 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1231388
27 February 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1246166
6 November 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 910110
24 May 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 918628
1 March 1990 Hull Examination · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 900027
23 March 1989 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 898973
10 February 1989 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1038125
17 May 1988 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1339053
25 February 1988 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1030528
17 March 1987 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1319454
19 December 1986 Deficiency Check · Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1313612
21 May 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1298751
12 March 1986 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 993726
25 June 1985 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 990229
28 March 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 980511

Deficiency record · 30

Construction/Loadline
Issued 7 March 1994 Resolved
SEAL ALL OPENINGS IN WATERTIGHT BULKHEADS THROUGHOUT VESSEL.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Electrical
Issued 7 March 1994 Resolved
INSTALL BREAKER BLANKS IN ALL ELECTRICAL DISTRIBUTION PANELS.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Electrical
Issued 7 March 1994 Resolved
REPAIR OR REPLACE LIGHTING FIXTURES THROUGHOUT VESSEL WITH U/L MARINE TYPE LIGHTING FIXTURES.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Electrical
Issued 7 March 1994 Resolved
COVER ALL ELECTRICAL TERMINALS, SHUNTS, AND STARTING SWITCHES.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Electrical
Issued 7 March 1994 Resolved
REMOVE ALL WIRE NUTS FROM VESSEL'S ELECTRICAL SYSTEMS.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Construction/Loadline
Issued 7 March 1994 Resolved
INSTALL METAL FITTING IN ALL PVC SYSTEMS PENETRATING TRANSVERSE BULKHEADS.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Deck/Cargo
Issued 16 October 1991 Resolved
D1-REPLACE CAPSTAN MOTOR IN FOREPEAK.
Condition: Unknown
Due 18 October 1991
Resolved 25 October 1991
Construction/Loadline
Issued 16 October 1991 Resolved
D2-TIGHTEN OR REPLACE THE THRU HULL FITTINGS ON THE STBD. SIDE (2) BETWEEN FRAMES NO.24AND26. IN THE ENGINEROOM.
Condition: Unknown
Due 18 October 1991
Resolved 25 October 1991
Engineering
Issued 16 October 1991 Resolved
D3-INSTALL FLAME SCREENS IN FUEL TANKS VENTS PORT AND STBD. SIDE.
Condition: Unknown
Due 18 October 1991
Resolved 25 October 1991
Engineering
Issued 27 February 1991 Resolved
PROVIDE FLAME SCREENS FOR FUEL TANKS PORT&STRB
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Fire Fighting
Issued 27 February 1991 Resolved
PROVIDE ADDITIONAL HOSE CLAMPS FOR ALL HOSE SECTIONS OF RAW WATER INTAKE FOR FIRE PUMP
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Engineering
Issued 24 May 1990 Resolved
REDUCE NON-METALLIC FLEX HOSE ON ENG FUEL SUPPLY LINES TO 30" OR LESS ON EACH SUPPLY LINE WITH METALLIC LINE
Condition: Unknown
Due 24 May 1990
Resolved 24 May 1990
Navigation
Issued 1 March 1990 Resolved
PROPERLY INSTALL COAST GUARD APPROVED NAVIGATION LIGHTS SUITABLE FOR A VESSEL LESS THAN 20 METERS.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Lifesaving
Issued 1 March 1990 Resolved
PROVIDE TWO PADDLES PROPERLY ATTACHED TO EACH LIFEFLOAT.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Lifesaving
Issued 1 March 1990 Resolved
PROVIDE 13 ADDITIONAL ADULT PFD'S PROPERLY EQUIPPED;TOTAL NUMBER OF PERSONSALLOWED IS REDUCED TO 107 UNTIL CORRECTED.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Construction/Loadline
Issued 10 February 1989 Resolved
CORRECT BAD PLANK IN WAY OF FORWARD PART OF THE STARBOARD SHAFT LOG. (THE PLANK WAS REPLACED AND THE SHAFT LOG TREATED.)
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Construction/Loadline
Issued 10 February 1989 Resolved
REFASTEN THE FLOORS TO THE FRAMES IN THE FUEL TANK AND STEERING GEAR COMPARTMENT TO REPLACE STRENGTH TO THE STRUCTURE. 8 FRAMES AND BULKHEADS ARE INVOLVED.
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Construction/Loadline
Issued 10 February 1989 Resolved
MAKE CHINE BOARDS AND OTHER PLANKS ON EACH SIDE SECURE TO THE TRAMSOM ON THE PORT AND STARBOARD SIDE AFT.
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Construction/Loadline
Issued 10 February 1989 Resolved
REPLACE THE MISSING CHINE BOLT ON THE PORT SIDE OF THE VESSEL. (REPLACED)
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Construction/Loadline
Issued 10 February 1989 Resolved
REPLACE ROTTED AND WORM DAMAGED BOARD OVER THE STARBOARD RUDDER. (BOARD WAS PROPERLY REPLACED NO DAMAGE TO OTHER PLANKS FOUND.)
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Engineering
Issued 17 May 1988 Resolved
PROVIDE ADEQUATE GUARDS TO ALL EXPOSED BELTS ON THE ENGINES AND GENERATOR.
Condition: Unknown
Due 17 May 1988
Resolved 17 May 1988
Fire Fighting
Issued 17 May 1988 Resolved
HAVE THE CO2 EXTINGUISHERS HYDROSTATICALLY TESTED.
Condition: Unknown
Due 17 May 1988
Resolved 17 May 1988
Unknown
Issued 17 March 1987 Resolved
PROVIDE 15 TYPE 1 ADULT PERSONAL FLOTATION DEVICES.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Unknown
Issued 17 March 1987 Resolved
PROVIDE PROPER WIRING IN WAY OF ALL RECEPTICALS, ACCESSORIES AND MACHINERY (12V & 110 SYSTEMS).
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Unknown
Issued 17 March 1987 Resolved
PROVIDE PROPER VALVE IN WAY OF COLLISION BULKHEAD BILGE PIPING PENETRATION.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Unknown
Issued 17 March 1987 Resolved
PROVIE SATISFACTORY OPERATION OF FIRE PUMP/STATION.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Unknown
Issued 17 March 1987 Resolved
PROVIDE ONE EMERGENCY LIGHT.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Unknown
Issued 17 March 1987 Resolved
PROVIDE 15 ADULT PERSONAL FLOTATION DEVICES.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Unknown
Issued 17 March 1987 Resolved
PROVIDE SATISFACTORY OPERATION OF ALL SALOON DOORS.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Construction/Loadline
Issued 19 December 1986 Resolved
MAKE VESSEL AVAILABLE TO THE USCG TO CONDUCT AN UNDERWAY INSPECTION TO DETERMINE HOW MUCH AND WHERE VESSEL IS WORKING.
Condition: Unknown
Due 19 December 1986
Resolved 19 December 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.