Records from 1985 to 2005. Most recent: inspection, 6 May 2005.
Inspection history · 41
6 May 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2362119
28 October 2002
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1697192
19 November 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1075746
30 September 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1397250
14 June 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 807636
28 May 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 807259
4 May 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 798106
8 May 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1125004
13 April 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126500
17 July 1997
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1115586
28 April 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1092311
15 April 1997
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1099272
23 April 1996
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1082887
17 April 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 881965
30 October 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1182460
16 May 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 928114
27 April 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1036627
7 August 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 188998
19 April 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 857621
8 April 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858489
28 October 1993
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 832304
14 April 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1149577
24 April 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 962024
8 April 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 962030
26 September 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 938179
17 April 1991
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1219703
9 April 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 906084
13 September 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 925454
13 April 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1235526
26 March 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 936819
26 March 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1219227
25 April 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1341464
10 April 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1199611
21 March 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1210099
12 April 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1195807
25 March 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1300195
6 April 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1002184
30 September 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1010014
14 April 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 999254
22 November 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 995713
30 May 1985
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1291264
Construction/Loadline
Issued 14 June 1999
Resolved
CLEAN OIL FROM BILGES IN THE ENGINE ROOM.
Condition: Unknown
Due 15 June 1999
Resolved 18 June 1999
Lifesaving
Issued 14 June 1999
Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR WITH ALL CREW MEMBERS.
Condition: Unknown
Due 15 June 1999
Resolved 18 June 1999
Construction/Loadline
Issued 14 June 1999
Resolved
CONNECT BILGE PIPING IN NEW COMPARTMENT FORWARD OF LAZARETTE SPACE.
Condition: Unknown
Due 15 June 1999
Resolved 18 June 1999
Documentation
Issued 15 April 1997
Resolved
PROVIDE DOCUMENTATION TO SHOW COMPLIANCE WITH CHEMICAL TESTING PROGRAM REQUIREMENTS.
Condition: Unknown
Due 22 April 1997
Resolved 30 April 1997
Lifesaving
Issued 15 April 1997
Resolved
PROPERLY LABEL PFD STOWAGE.
Condition: Unknown
Due 22 April 1997
Resolved 30 April 1997
Lifesaving
Issued 15 April 1997
Resolved
POST LIFEJACKET DONNING INSTRUCTIONS.
Condition: Unknown
Due 22 April 1997
Resolved 30 April 1997
Construction/Loadline
Issued 15 April 1997
Resolved
ATTACH CAPTURE CHAINS TO ALL DECK OPENING HATCH COVERS.
Condition: Unknown
Due 22 April 1997
Resolved 30 April 1997
Lifesaving
Issued 15 April 1997
Resolved
REPLACE 8 ADULT SIZE PFD. PASSENGER CAPACITY REDUCED TO 55 UNTIL THIS REQUIREMENT IS COMPLIED WITH.
Condition: Unknown
Due 22 April 1997
Resolved 30 April 1997
Electrical
Issued 15 April 1997
Resolved
REMOVE DEAD END WIRES FROM FOREPEAK.
Condition: Unknown
Due 22 April 1997
Resolved 30 April 1997
Engineering
Issued 15 April 1997
Resolved
REPLACE BREATHER TUBE ON PORT ENGINE GOVERNOR.
Condition: Unknown
Due 22 April 1997
Resolved 30 April 1997
Lifesaving
Issued 15 April 1997
Resolved
REPLACE LADDER USED FOR MAN OVERBOARD RECOVERY.
Condition: Unknown
Due 22 April 1997
Resolved 30 April 1997
Construction/Loadline
Issued 23 April 1996
Resolved
REFASTEN PLANKS ON PORT SIDE OF THE FOREPEAK AT FRAME #1 ABOVE WATERLINE.
Condition: Unknown
Due 30 April 1996
Resolved 8 May 1996
Accommodation/Occupational Safety
Issued 23 April 1996
Resolved
REINSTALL WASH BASINS IN THE MENS AND WOMENS HEADS.
Condition: Unknown
Due 30 April 1996
Resolved 8 May 1996
Construction/Loadline
Issued 17 April 1996
Resolved
RENEW FOREPEAK KEEL BOLTS.
Condition: Unknown
Due 17 April 1996
Resolved 6 May 1996
Construction/Loadline
Issued 17 April 1996
Resolved
PROVE ADEQUACY OF KEEL FLOOR PINS.
Condition: Unknown
Due 17 April 1996
Resolved 7 May 1996
Construction/Loadline
Issued 17 April 1996
Resolved
RENEW BOTTOM PLANK AMIDSHIP IN WAY OF CHINE LOG AND STBD QTR AT WATERLINE (SIDE PLANK).
Condition: Unknown
Due 17 April 1996
Resolved 6 May 1996
Construction/Loadline
Issued 17 April 1996
Resolved
PROVE PROPER OPERATION OF LAZARETTE BILGE SUCTION LINE.
Condition: Unknown
Due 17 April 1996
Resolved 6 May 1996
Unknown
Issued 17 April 1996
Resolved
SUBMIT WRITTEN PROPOSAL FOR COMPLETING ABOVE ITEMS PRIOR TO PLACING VESSEL BACK IN SERVICE.
Condition: Unknown
Due 17 April 1996
Resolved 7 May 1996
Construction/Loadline
Issued 17 April 1996
Resolved
RENEW WASTED LAG BOLTS IN KEEL.
Condition: Unknown
Due 17 April 1996
Resolved 6 May 1996
Lifesaving
Issued 17 April 1996
Resolved
REMOVE CENTERLINE FLOOR BOARDS, CLEAN BILGE IN ENGINR ROOM AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 17 April 1996
Resolved 6 May 1996
Construction/Loadline
Issued 17 April 1996
Resolved
REMOVE MAIN DECK IN WAY OF SHEER PLANK FORWARD OF MAIN CABIN AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 17 April 1996
Resolved 6 May 1996
Lifesaving
Issued 27 April 1995
Resolved
PLACE AN ADDITIONAL COAST GUARD APPROVED HAND SMOKE SIGNAL ON BOARD VESSEL,PRIOR TO OPERATION AND NO LATER THAN 27 APRIL, 1995.
Condition: Unknown
Due 27 April 1995
Resolved 5 May 1995
Lifesaving
Issued 27 April 1995
Resolved
PROPERLY LABEL NEW RING BUOY.
Condition: Unknown
Due 27 April 1995
Resolved 5 May 1995
Accommodation/Occupational Safety
Issued 27 April 1995
Resolved
REPAIR RAILING AMIDSHIPS STARBOARD SIDE, AND ON PORT QUARTER, NO LATER THAN12 MAY, 1995.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Accommodation/Occupational Safety
Issued 27 April 1995
Resolved
REPLACE BROKEN WINDOW IN CREW'S CABIN STARBOARD SIDE, NO LATER THAN 12 MAY,1995.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Lifesaving
Issued 27 April 1995
Resolved
PROPERLY LABEL TWO ADULT PFD'S AND ONE CHILD PFD; REPLACE TWO ROTTED PFD'S WITH COAST GUARD APPROVED TYPE 1 ADULT, PRIOR TO OPERATION.
Condition: Unknown
Due 27 April 1995
Resolved 5 May 1995
Lifesaving
Issued 27 April 1995
Resolved
PLACE PYROTECHNICS IN WATERPROOF CONTAINER.
Condition: Unknown
Due 27 April 1995
Resolved 5 May 1995
Engineering
Issued 19 April 1994
Resolved
REINSTALL BONDING WIRE ON STARBOARD FUEL TANK FILL.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Electrical
Issued 19 April 1994
Resolved
REMOVE UNUSED RED WIRE ON THE OUTBOARD SIDE OF THE PORT MAINE ENGINE.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Electrical
Issued 19 April 1994
Resolved
INSTALL LIGHT FIXTURE IN THE MENS HEAD.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Electrical
Issued 19 April 1994
Resolved
PROPERLY SECURE ELECTRICAL CONNECTION FOR THE INSTALLED HEATER.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Electrical
Issued 19 April 1994
Resolved
PROPERLY SECURE ELECTRICAL CONNECTION IN OVERHEAD AFT OF DECK HOUSE AFT DOOR.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Engineering
Issued 19 April 1994
Resolved
REPLACE STARBOARD AFT ENGINE ROOM VENT COWL.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Construction/Loadline
Issued 19 April 1994
Resolved
INSTALL PLANK AND GUNWALE UPRIGHTS AT TRANSOM TO MAKE LAZARETTE WATERTIGHT.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Electrical
Issued 19 April 1994
Resolved
INSTALL BATTERY IN FORWARD BOUYANCY APPARATUS WATERLIGHT.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Construction/Loadline
Issued 19 April 1994
Resolved
MAKE TIGHT THE CHINE AREA LEAKING IN THE FORWARD CREW SPACE PORT SIDE.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Electrical
Issued 19 April 1994
Resolved
REMOVE UNUSED GRAY WIRE ON THE OUTBOARD SIDE OF THE STARBOARD MAIN ENGINE.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Navigation
Issued 19 April 1994
Resolved
SECURE HYDRAULIC STEERING PIPING IN HANGERS.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Electrical
Issued 19 April 1994
Resolved
SECURE SHORT AT FORWARD ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Lifesaving
Issued 19 April 1994
Resolved
OBTAIN 6 ADULT PFD'S.
Condition: Unknown
Due 19 April 1994
Resolved 10 May 1994
Documentation
Issued 19 April 1994
Resolved
PROVIDE PROOF OF ENROLLMENT IN A PRE-EMPLOYMENT AND RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 3 May 1994
Resolved 4 May 1994
Navigation
Issued 24 April 1992
Resolved
PROVE SATISFACTORY OPERATION OF VESSELS RADAR.
Condition: Unknown
Due 22 May 1992
Resolved 11 May 1992
Documentation
Issued 24 April 1992
Resolved
PROVIDE DOCUMENTATION SHOWING PROOF OF VALID MARINE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 22 May 1992
Resolved 11 May 1992
Engineering
Issued 26 September 1991
Resolved
REINSTALL STARBOARD ENGINE AND PROVE PROPER OPERATION PRIOR TO CARRYING PASSENGERS FOR HIRE. NOTE: HULL EXAMINATION DUE 30 SEP 91. DRYDOCK EXTENSION PENDS REEVALUATION FOLLOWING COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Construction/Loadline
Issued 26 March 1990
Resolved
TWO PLANKS RENEWED. 8 FOOT PLANK STBD SIDE THIRD FORWARD FROM STERN AND 15 FOOT 6 INCH PLANK PORT SIDE 2ND STRAKE SECOND PLANK FORWARD OF TRANSOM.
Condition: Unknown
Due 26 March 1990
Resolved 26 March 1990
Navigation
Issued 10 April 1989
Resolved
PORT RUNNING LIGHT NOT OPERATING AT THE TIME OF THE INSPECTION. FIXED DURING THE INSPECTION.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Navigation
Issued 10 April 1989
Resolved
SECURING DEVICES FOR WATER TIGHT HATCHES WERE NOT ATTACHED TO TO THE VESSEL
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989