← All vessels
EMERALD STAR
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Northwest District (CGD-NW) · Other hulls named EMERALD STAR
EMERALD STAR is a 1996 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1996, most recently in June 2025, along with 55 deficiencies, 1 operational control and 4 casualty investigations between 2007 and 2014.
Records from 1996 to 2025. Most recent: inspection, 3 June 2025.
- Built
- 1996
- Last inspected
- 3 June 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 55 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2007–2014
Identity
1040255
WDD2985
437315
Flag
UNITED STATES
367122360
Maury page id
psix-437315
Inspections, by type
…with no type recorded3
Years with a record
25 calendar years (1996–2025)
The 47 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)96.9 ft × 20.0 ft × 5.5 ft
Registered tonnagegross 66 / net 44
ITC dimensions (L × B × D)96.9 ft × 20.0 ft × 5.5 ft
ITC tonnagegross 192 / net 57
BuilderMID-CITY STEEL FABRICAT · LA CROSSE, WI, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it192 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Gross Ton
57 - Convention (Subpart B), Net Ton
44 - Regulatory (Subpart C or D), Net Ton
66 - Regulatory (Subpart C or D), Gross Ton
57 - Convention (Subpart B), Net Ton
44 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD2985MMSI 367122360 · active · compulsorily equipped · granted 6 July 2026, expires 17 June 2036
WCW7286MMSI 367045010 · expired · compulsorily equipped · granted 10 July 1996, cancelled 9 September 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 47
3 June 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151906
5 April 2024
MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7890294
23 May 2023
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7702340
7 April 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7424147
16 February 2022
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7397378
12 January 2022
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7380734
29 June 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7239902
2 June 2021
Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7213670
21 May 2021
Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7206280
13 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6972563
20 May 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6688719
7 May 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6408437
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360391
3 April 2017
DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6113120
14 March 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5838164
10 February 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5813102
5 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202138
24 March 2010
DAPI Audit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3780695
4 March 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3698816
22 July 2009
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3542407
27 April 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3462526
21 April 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3187304
21 September 2007
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3063176
17 June 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2968090
30 April 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2917228
23 May 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2659223
17 March 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2604368
8 December 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2548211
15 July 2005
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2427992
23 May 2005
Annual Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2366323
28 December 2004
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2267887
22 April 2004
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2050227
27 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1976345
14 April 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1772254
23 April 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1608176
22 March 2001
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1384706
3 May 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386487
1 May 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1361444
28 April 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411684
2 April 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788452
28 April 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1433187
25 June 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1085627
12 June 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 879243
8 May 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1467469
3 May 1996
Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363633
25 April 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1082249
2 April 1996
Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1417914
Deficiency record · 55
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck.
During test of fuel shutoff valves, valves were unable to close completely allowing fuel flow. Valve was able to close approximately 70%.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 3 June 2025
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers:(2)On each life float and buoyant apparatus. (e)The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus.
Five buoyant apparatus did not have the correct name of the vessel and the number of persons (22 persons) were faded or illegible on approximately half of buoyant apparatus
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 June 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(a) Charts of large enough scale to make safe navigation possible.
Vessel did not have current charts and have never updated the applicable charts.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2024
Resolved
Security exercises must be conducted at least once each calendar year, with no more than 18 months between exercises.
No available record of security exercises.
For each annual audit
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 May 2023
Resolved
Bilge alarm in the forward bilge did not have indicating light that illuminated on the bridge
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 May 2023
Resolved
Light on the number 3 buoyant aparatus did not have a working float light
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 14 August 2020
Resolved
All electrical equipment and circuits must be clearly marked and identified. The circuit breakers are not labeled correctly and the required amperage based on the electrical plans is not labeled. Required to mark and label the circuit breakers with the correct load it supplies and the correct amperage based on the vessel electrical plans.
46 CFR 120.220
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2020
Resolved
Tested the water lights attached to the life floats. About half of them did not work. Required to test all of them and replace the batteries of the inoperable lights. Also, the yellow lifelines on two of the life floats was falling apart and needs to be replaced.
46 CFR 122.700
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2020
Resolved
The adult life jackets were located behind a blue tarp with no markings. Required to label with the number and identification of the items stowed inside.
46 CFR 122.604 (f)
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 June 2020
Resolved
The portable fire extinguisher on the open upper deck, the needle in the gauge was not within the green section. Required to get serviced or replace.
46 CFR 176.25-25
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 June 2020
Resolved
The Emergency lights on the main passenger deck were inoperable. Required to fix.
46 CFR 120.432
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2020
Resolved
A bilge high level alarm needs to be secured. The high level alarm in the void with the soda equipment was just laying on the hull. Required to secure.
46 CFR 119.530
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2020
Resolved
Noted an outlet with charring on it near the bridge consul. Upon further investigation of the wires, outlets and circuit breakers: the vessel has a mix match of 20 amp outlets with 14 AWG and 15 and 20 amp circuit breakers. Requiring the 20 amp outlets be replaced with 15 amp outlets. Also all the circuit breakers need to be changed to 15 amps. The other option is to rewire the vessel.
46 CFR 183.05-45
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 June 2020
Resolved
Noted that there was no fire door between the upper and lower passenger areas. Upon further inspection, it appears the door has been removed but there were still latches on the wall. Limiting passenger count to 150 until fire door is installed.
46 CFR 116.435
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 June 2019
Resolved
Provide charts of large enough scale to make safe navigation possible.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 June 2019
Resolved
Provide VHF radio with Digital Selective Calling capability. 47CFR 80.905(a)(1).
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 June 2019
Resolved
Replace 2 deteriorating doors on upper passenger deck to maintain adequate fire boundaries by 10/01/2019.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 June 2019
Resolved
Ensure fuel line on STBD MDE is properly supported.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 June 2019
Resolved
Replace deteriorating bilge line on STBD MDE.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 11 June 2019
Resolved
Provide Employee Assistance Program information to all employees.
Engineering › Bilge Water Management System › Valve
Issued 7 May 2018
Resolved
Ensure bilge pumping system operates with sufficient suction prior to embarkation of passengers. Deficiency cleared on the spot; system was initially inop due to mislabeled valves. Vessel will renew bilge instructions and valve labels.
Lifesaving › Lifefloat › Retroreflective Material
Issued 7 May 2018
Resolved
Replace ineffective retro-reflective tape on all life-flots.
Electrical › Electric Supply System (service) › Battery Charger
Issued 7 May 2018
Resolved
Ensure all permanently installed electrical equipment is hardwired to switchboard. 14-days granted to either remove battery charger or have electrician hardwire to breaker panel.
Lifesaving › Lifefloat › Lifeline
Issued 14 March 2016
Resolved
Replace marked lifefloat lines that are deteriorated.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 14 March 2016
Resolved
Rescue platform needs lanyard attaching platform to vessel.
Engineering › Fuel Oil Service System › Piping
Issued 14 March 2016
Resolved
STBD engine fuel rail bolt weld broken. Re-weld mount bolt to frame.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 14 March 2016
Resolved
Investigate sewage tank leak in liquor hold and submit repair plan.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 14 March 2016
Resolved
All masters operating vessel required to hold valid radio operator permit. Provide proof of permit.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 March 2010
Resolved
Provide Employee Assistance Program that meets the requirements of 46 CFR Part 16.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 24 March 2010
Resolved
Provide drug and alcohol testing program that meets the requirements of 46 CFR Part 16.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 22 July 2009
Resolved
Vessel's port shaft keyway is damaged and in need of repair/replacement.
Lifesaving › Lifefloat › Netting
Issued 27 April 2009
Resolved
Lifefloat net frames are broken along area of net installation. Replace/repair lifefloat net frame to ensure proper operation on all 12 lifefloats on vessel IAW 46 CFR 117.175(a).
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 21 April 2008
Resolved
Renew anchor light or repair as needed to provide proper illumination.
Lifesaving › Lifefloat › Paddle
Issued 21 April 2008
Resolved
Label and secure paddles in lifefloats.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 21 April 2008
Resolved
Clean corrosion on battery terminals in the engine room.
Engineering › Bilge Water Management System › Manifold
Issued 21 April 2008
Resolved
Provide proper bilge piping diagram in engine room.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 21 April 2008
Resolved
Provide proper operation of hatch cover in galley. Hydraulic rods require renewal or removal. One of two hinges is broken.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 April 2008
Resolved
Replace emergency lighting bulb at starboard side entry.
Engineering › Fuel Oil Service System › Valve
Issued 21 April 2008
Resolved
Provide proper operation of emergency fuel shut-off valve assembly. Present configuration does not allow full closure of valves using multi-valve linkage.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 April 2008
Resolved
Properly secure lifeline to ring life buoy.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 April 2007
Resolved
Remove extension cord leading to temporary lighting in beverage compartment.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 30 April 2007
Resolved
Secure CO2 bottle in beverage compartment.
Engineering › Bilge Water Management System › Not Operational
Issued 23 May 2006
Resolved
Prove operation of PTO bilge pump #2 MDE.
Communications › Alarms/Indicators › High Water Alarm
Issued 23 May 2006
Resolved
Prove operation of #6 high water alarm.
Operations/Management › Drills/Instruction
Issued 14 April 2003
Resolved
Cound not conduct drills because crew was not on board vessel.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 April 2003
Resolved
Floating electric waterlight was not properly attached to ring buoy.
Lifesaving › Rigid Liferafts › Weak Link
Issued 14 April 2003
Resolved
The weak link for the buoyant apparatus was not properly attached to the vessel.
Lifesaving › Rigid Liferafts › Markings
Issued 14 April 2003
Resolved
Buoyant apparatus did not have name or number of persons allowed marked on it.
Lifesaving › Rigid Liferafts
Issued 14 April 2003
Resolved
Surface of bouyant apparatus needs to be repaired. LEGACY COMPONENT DESC: Buoyant Material
Personnel › Manning/Qualifications
Issued 14 April 2003
Resolved
50% of crew could not provide proof of first aid/CPR training. LEGACY COMPONENT DESC: CPR Certified Personnel
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 14 April 2003
Resolved
Flammable liquids must be removed from void space. Space is not designed to handle flammable liquids.
Construction/Loadline › Structures
Issued 14 April 2003
Resolved
Gasket on hatch to forward void needs to be repaired. LEGACY COMPONENT DESC: Scuttle
Deck/Cargo
Issued 8 May 1996
Resolved
Demonstrate operation of bow thruster motor and controller electrical installation. Hydrostatic test of piping to 1.5 MAWP.
Fire Fighting
Issued 8 May 1996
Resolved
Weld shut/make flame and smoke tight to "A" class standards the 2 openings below main deck bar in #3 compartment.
Fire Fighting
Issued 8 May 1996
Resolved
Close opening in starboard overhead of upper deck head to "A-0" standards.
Casualty record · 4
17 June 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 2968090
4 July 2013Routine · role: Involved in a Marine Casualty · activity 4643362
1 September 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4717956
13 April 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4836030
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.