Records from 2002 to 2026. Most recent: inspection, 9 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 26
9 February 2026
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8308192
14 January 2026
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8290100
12 March 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8080975
28 January 2025
Administrative Inspection · In-Service Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8071829
2 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7859790
11 January 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7848779
16 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7628167
8 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7408955
11 January 2022
Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7379367
13 April 2021
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7174123
29 July 2020
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7019192
8 June 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6971050
11 March 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949068
11 March 2020
Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6979016
9 March 2020
Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6922896
8 April 2019
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6658506
20 November 2018
Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6584506
12 April 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6390452
21 December 2017
Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6326169
22 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6153111
9 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6144718
17 February 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6090477
12 January 2017
Administrative Inspection · Plan Review "T" Boat · Construction Oversight · Initial Construction-Excluding Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6070545
24 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5885918
18 April 2016
DAPI Audit · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5856761
4 January 2016
Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5790787
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 March 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Marine Inspector observed paper chart of operating area not up-to-date.
46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 7 April 2025
Resolution: Observed new chart onboard
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 March 2025
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Marine Inspector observed vessel did not have capability of to use appropriate sound signals. Vessel shall procure sound signaling
device with half mile hearing capability.
33 CFR 83.33 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel procured new sound signaling device and placed on board.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 12 March 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Marine inspector observed painters tape and sharper indicating the number of passengers allowed on the upper deck.
46 CFR 185.602 (g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: MI observed new sign with max persons allowed on top side deck.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 March 2025
Resolved
For vessels other than those covered the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Marine Inspector observed vessel name missing on port and starboard side of the bow and fading of name and hailing port on the stern.
46 CFR 67.123 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: MI observed name on boath port and starboard bow and touched up on the stern. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2025
Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the
same material the hull is constructed of, or some
noncombustible material. Marine Inspector observed fuel shut-off valve located inside the space without proper shielding or protection. Vessel shall install shielding protection to shut-off valves.
46 CFR 182.455 (b)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 7 April 2025
Resolution: MI observed new pull cable installed as to were crew does not need to stick their hand down in engine room to secure fuel in an emergency event.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 March 2025
Resolved
Beginning January 2, 2013, any small passenger vessel that does not carry a reserve power supply must carry at least one VHF handheld radiotelephone. Marine inspector observed vessel did not have VHF handheld radiotelephone
In addition, the vessel does not have a reserve power supply. Install appropriate reserve power supply or as an acceptable alternative, provide a VHF FM handheld radio with appropriate charger. The FCC issuing authority for the Radiotelephony Certificate utilized an outdated “How to Conduct an Inspection of a Small Passenger Vessel” checklist. Provide new Radiotelephony Certificate using the updated checklist, revision 2021.02.24.
47 CFR 80.917 (h)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: Operator installed new handheld vhf radio on baord with MMSI and latitude and longitude capability. all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 March 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices. Marine inspector observed weep/leak on the port hold/engine room of the hull. Vessel shall caulk weeps/leaks throughout entire vessel.
46 CFR 176.830 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: Vessel operator caulked weeps and leaks. all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 March 2025
Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of the Inland Navigation Rules.
33 CFR 83.01 (g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel procured new nav rules and placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 March 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Marine inspector observed 2 adult jackets in poor condition. Corrected on the spot.
46 CFR 176.808 (b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 March 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 January 2022
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with roll and pitch of the vessel, and free from exposure to water splash or spray. Batteries were open/not in containers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2022
Resolution: Repairs Satisfactory
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 April 2021
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead; watertight bulkhead was not watertight.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: Hole in bulkhead was repaired and tested as indicated in repair proposal.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2021
Resolved
There was no fire nozzle attached to hose at fire station.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: Approved nozzle was replaced to hose.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 April 2021
Resolved
The pre-engineered fixed gas fire extinguishing system had no audible or visual alarm at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: Both visual and audible alarm tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 April 2021
Resolved
The steering system's starboard outboard ram was leaking hydraulic fluid.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: Leak was repaired and steering system was tested while underway.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 April 2021
Resolved
Steering system's starboard hydraulic ram was not secured to it's mount.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: The steering system's hydraulic ram was secured to it's mount and tested while underway.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 April 2021
Resolved
Navigational charts were not up-to-date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 15 April 2021
Resolution: New up-to-date navigational charts were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2021
Resolved
The ring life buoy lifeline was yellow in color and deteriorating.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2021
Resolved 15 April 2021
Resolution: A new life line was provided which was the correct color.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 April 2021
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level; alarm in forward compartment had no visual alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 15 April 2021
Resolution: High water alarm was fixed and tested and worked correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2021
Resolved
Both shafts in engine compartment and belts on forward part of engine were exposed hazards and were missing guards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 19 May 2021
Resolution: Guards were placed on both shafts in engine compartment and belts on forward part of engines. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2021
Resolved
36 lifejackets had failing and deterorating retroreflective tape. Passenger count is limited to 40 adults until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2021
Resolved 15 April 2021
Resolution: Retroreflective tape was repaired on all lifejackets.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 May 2020
Resolved
The owner must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. The fire extinguishers and FireBoy have not been inspected since January 2019, and the Fireboy is not installed properly.
46CFR176.810(b)(1)(iv)
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2020
Resolved 29 July 2020
Resolution: Vessel sent in fire servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire caused by or originating in electrical equipment and electrical shock. Cables not connected or ending in a junction box in the steering gear room.
46CFR183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 29 July 2020
Resolution: Vessel sent in pictures of the wires being properly secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 May 2020
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Shaft penetration through the bulkhead is not watertight.
46CFR171.114(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 29 July 2020
Resolution: Vessel sent in pictures of the through holes with proper sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 May 2020
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessels name. Vessels name has faded from the ring lifebuoy.
46CFR185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 29 July 2020
Resolution: Vessel sent in pictures of the life ring with its new lettering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2020
Resolved
Vessel is replacing both MDE's along with new reduction gears and electronic throttles.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 July 2020
Resolved 29 May 2020
Resolution: Vessel performed DVTPs IAW manufacturers instruction satisfactorly. Full power trials and crash stop SAT as well
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 25 April 2019
Resolved
01 MSD valve not secured. Secure MSD valve with proper lock to prevent accidental discharge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Valve secured
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 April 2019
Resolved
02 Automatic bilge pump indicating light for cargo space and engine room not operational. Fix indicating lights for automatic bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Fixed indicating light
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2019
Resolved
03 Exposed wire splices on aft of mast. Cover with junction box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Covered exposed wire.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 April 2019
Resolved
04 Radiotelephony Safety certificate is expired. Provide valid certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Provided updated certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2019
Resolved
05 Outlet cover in STBD, aft of engine room missing. Replace cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Outlet cover provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2019
Resolved
06 Waterlight for ring bouy not operational. Provide working waterlight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Waterlight operational
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 April 2018
Resolved
Found expired meds in first aid kit, replace all expired meds.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: First Aid Kid replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 April 2018
Resolved
Overhead was found leaking water with a temp repair of plastic to keep water out of junction box. Make repairs to overhead to keep water out of junction box.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: Junction box moved to appropriate location.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 April 2017
Resolved
Install GPD tp VHF-DSC IAW 47 CFR 80.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 22 May 2017
Resolution: VHF to GPS installed and working.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 5 April 2017
Resolved
Make high water visual and audible alarm in lazarett operate correctly. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 9 May 2017
Resolution: Bilge audible and visual alarms operational.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 April 2017
Resolved
Update and maintain drill logs IAW 46 CFR 185.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 9 May 2017
Resolution: Logs updated.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 April 2017
Resolved
Provide proof of supervisory training completion, IAW 46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 22 May 2017
Resolution: Provided training cert.
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 5 April 2017
Resolved
Demonstrate that flow meters are installed and working properly IAW 46 CFR 182.425
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 22 May 2017
Resolution: Flow meters installed and checked on both engines.
Stability › Watertight Integrity › General
Issued 5 April 2017
Resolved
Remove sluice valve and cap to prevent water draining from fwd collision bulkhead to aft compartment IAW 46 CFR 179.320
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 9 May 2017
Resolution: Piping capped off.
Engineering › Electric Propulsion System › Battery
Issued 25 April 2016
Resolved
STBD battery could not hold sufficient charge. Replace battery.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 24 May 2016
Resolution: Battery was replaced and working.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 25 April 2016
Resolved
Vessel had improper fuel lines leading from fuel filter to fuel tank. Install line that meets J1942.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Proper hose was installed and checked.
Engineering › Fuel Oil Service System › Valve
Issued 25 April 2016
Resolved
Fuel shut off valve was inoperable. Make valve operable IAW. 46 CFR 182.455
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Both port and stbd fuel shut off valve worked properly.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2016
Resolved
Provide visual means to indicate operation of submersible electric pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: All bilge pump indicators at operating station showed light when running.
Communications › Alarms/Indicators › High Water Alarm
Issued 25 April 2016
Resolved
Provide visual and audible alarm for bilge high level alarms. Visual inspection of all voids shall be conducted and logged at intervals of no more than 20 min until repaired
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: All high water alarms worked at operating station.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 25 April 2016
Resolved
No updated harbor chart for vessels area of operation. Obtain and make available updated chart.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Charts and pubs updated.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 April 2016
Resolved
Provide and update drug testing program documentation for all crew members.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Provided paper work with all crew members on DAPI program.
Electrical › Electric Supply System (service) › Cable
Issued 25 April 2016
Resolved
Secure all exposed wiring in cargo compartment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Wiring in cargo space was secured properly.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 25 April 2016
Resolved
EPIRB hydrostatic release unit was expired. Replace EPIRB hydrostatic release unit marked with the correct 2 year expiration date.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: New hydra release was installed and properly marked.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 25 April 2016
Resolved
Repair/Replace gauge to indicate engine RPM at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: RPM gauges worked for both main engines.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 March 2016
Resolved
Make the four internal bulkheads seperating the spaces as water-tight as possible (fill all holes, etc.). IAW 46 CFR 179.212
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: All four internal bulkheads were made water-tight.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 3 March 2016
Resolved
Ensure all electrical outlets in the engine room space have covers (to shield the outlet from moisture when nothing would be plugged in). IAW 46 CFR 183.210
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: All electrical outlets were made secure.
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 March 2016
Resolved
Remove the extra battery lying on the hull planking, in the engine-room. IAW 46 CFR 183.350.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: Extra battery was removed from hull-planking.