AMERICAN STAR

AMERICAN STAR is a 1959 passenger vessel (inspected). The Coast Guard has recorded 83 inspections since 1984, most recently in February 2026, along with 146 deficiencies and 1 casualty investigation in 2002.

Records from 1984 to 2026. Most recent: inspection, 9 February 2026.

Built
1959
Last inspected
9 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG8099
Flag
UNITED STATES
367574010
Maury page id
psix-43733

Inspections, by type

…with no type recorded7
Years with a record 38 calendar years (1984–2026)
The 83 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.2 ft × 17.5 ft × 5.7 ft
Registered tonnagegross 45 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICE MARINE RAILWAY CO · REEDVILLE, VA, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 13 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG8099MMSI 367574010 · active · compulsorily equipped · granted 16 March 2023, expires 10 May 2033
WDC5744MMSI 367045810 · expired · voluntarily equipped · granted 28 May 2005, cancelled 1 August 2015
WCM2737MMSI not assigned · expired · voluntarily equipped · granted 24 August 1994, cancelled 30 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HULL #40 Unclassified · MISLE 435225 · 4 October 1995 · activity 36125

Inspection history · 83

9 February 2026 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8308192
14 January 2026 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8290100
12 March 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8080975
28 January 2025 Administrative Inspection · In-Service Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8071829
2 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7859790
11 January 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7848779
16 February 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7628167
8 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7408955
11 January 2022 Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7379367
13 April 2021 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7174123
29 July 2020 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7019192
8 June 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6971050
11 March 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949068
11 March 2020 Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6979016
9 March 2020 Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6922896
8 April 2019 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6658506
20 November 2018 Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6584506
12 April 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6390452
21 December 2017 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6326169
22 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6153111
9 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6144718
17 February 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6090477
12 January 2017 Administrative Inspection · Plan Review "T" Boat · Construction Oversight · Initial Construction-Excluding Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6070545
24 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5885918
18 April 2016 DAPI Audit · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5856761
4 January 2016 Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5790787
19 May 2014 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4862095
15 May 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4823272
6 June 2012 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4311962
30 December 2011 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4216130
15 April 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3180879
18 March 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3155585
28 February 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3151249
31 May 2006 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2665944
28 February 2006 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2659788
20 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2497324
9 August 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2523472
26 May 2005 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2342477
5 May 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2059758
22 December 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1965797
20 May 2003 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1792459
12 July 2002 Examination of Repairs · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1654970
11 July 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1658463
2 May 2002 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1611791
12 March 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1494679
31 May 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1370255
3 March 2000 Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393446
20 January 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1408441
4 March 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1432163
1 December 1998 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1339802
17 March 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460161
3 March 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1368602
2 September 1997 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1470931
1 April 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1117002
4 March 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1377989
26 March 1996 Re-Inspection · Hull Examination · Plan Review "T" Boat · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392458
4 October 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 36125
13 September 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 125233
30 May 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1183449
22 May 1995 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 870653
8 May 1995 Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1428482
23 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412766
11 August 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 871223
14 April 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 856913
4 March 1994 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857742
4 March 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1164609
12 March 1993 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832981
18 February 1992 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261680
4 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245360
7 March 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1221149
12 February 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219132
10 December 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907506
8 March 1990 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913509
2 August 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890479
28 July 1989 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040539
9 March 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033623
8 March 1988 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341036
2 January 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340618
17 March 1987 Re-Inspection · Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024082
13 March 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 999939
18 December 1985 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997187
25 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285673
12 December 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1284752

Deficiency record · 146

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 March 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Marine Inspector observed paper chart of operating area not up-to-date. 46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 7 April 2025
Resolution: Observed new chart onboard
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 March 2025 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Marine Inspector observed vessel did not have capability of to use appropriate sound signals. Vessel shall procure sound signaling device with half mile hearing capability. 33 CFR 83.33 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel procured new sound signaling device and placed on board.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 12 March 2025 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Marine inspector observed painters tape and sharper indicating the number of passengers allowed on the upper deck. 46 CFR 185.602 (g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: MI observed new sign with max persons allowed on top side deck.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 March 2025 Resolved
For vessels other than those covered the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Marine Inspector observed vessel name missing on port and starboard side of the bow and fading of name and hailing port on the stern. 46 CFR 67.123 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: MI observed name on boath port and starboard bow and touched up on the stern. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2025 Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Marine Inspector observed fuel shut-off valve located inside the space without proper shielding or protection. Vessel shall install shielding protection to shut-off valves. 46 CFR 182.455 (b)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2025
Resolved 7 April 2025
Resolution: MI observed new pull cable installed as to were crew does not need to stick their hand down in engine room to secure fuel in an emergency event.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 March 2025 Resolved
Beginning January 2, 2013, any small passenger vessel that does not carry a reserve power supply must carry at least one VHF handheld radiotelephone. Marine inspector observed vessel did not have VHF handheld radiotelephone In addition, the vessel does not have a reserve power supply. Install appropriate reserve power supply or as an acceptable alternative, provide a VHF FM handheld radio with appropriate charger. The FCC issuing authority for the Radiotelephony Certificate utilized an outdated “How to Conduct an Inspection of a Small Passenger Vessel” checklist. Provide new Radiotelephony Certificate using the updated checklist, revision 2021.02.24. 47 CFR 80.917 (h)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: Operator installed new handheld vhf radio on baord with MMSI and latitude and longitude capability. all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 March 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices. Marine inspector observed weep/leak on the port hold/engine room of the hull. Vessel shall caulk weeps/leaks throughout entire vessel. 46 CFR 176.830 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: Vessel operator caulked weeps and leaks. all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 March 2025 Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of the Inland Navigation Rules. 33 CFR 83.01 (g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: vessel procured new nav rules and placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 March 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Marine inspector observed 2 adult jackets in poor condition. Corrected on the spot. 46 CFR 176.808 (b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 March 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 January 2022 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with roll and pitch of the vessel, and free from exposure to water splash or spray. Batteries were open/not in containers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2022
Resolution: Repairs Satisfactory
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 April 2021 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead; watertight bulkhead was not watertight.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: Hole in bulkhead was repaired and tested as indicated in repair proposal.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2021 Resolved
There was no fire nozzle attached to hose at fire station.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: Approved nozzle was replaced to hose.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 April 2021 Resolved
The pre-engineered fixed gas fire extinguishing system had no audible or visual alarm at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: Both visual and audible alarm tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 April 2021 Resolved
The steering system's starboard outboard ram was leaking hydraulic fluid.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: Leak was repaired and steering system was tested while underway.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 April 2021 Resolved
Steering system's starboard hydraulic ram was not secured to it's mount.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 15 April 2021
Resolution: The steering system's hydraulic ram was secured to it's mount and tested while underway.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 April 2021 Resolved
Navigational charts were not up-to-date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 15 April 2021
Resolution: New up-to-date navigational charts were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2021 Resolved
The ring life buoy lifeline was yellow in color and deteriorating.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2021
Resolved 15 April 2021
Resolution: A new life line was provided which was the correct color.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 April 2021 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level; alarm in forward compartment had no visual alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 15 April 2021
Resolution: High water alarm was fixed and tested and worked correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2021 Resolved
Both shafts in engine compartment and belts on forward part of engine were exposed hazards and were missing guards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 19 May 2021
Resolution: Guards were placed on both shafts in engine compartment and belts on forward part of engines. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2021 Resolved
36 lifejackets had failing and deterorating retroreflective tape. Passenger count is limited to 40 adults until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2021
Resolved 15 April 2021
Resolution: Retroreflective tape was repaired on all lifejackets.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 May 2020 Resolved
The owner must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. The fire extinguishers and FireBoy have not been inspected since January 2019, and the Fireboy is not installed properly. 46CFR176.810(b)(1)(iv)
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2020
Resolved 29 July 2020
Resolution: Vessel sent in fire servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire caused by or originating in electrical equipment and electrical shock. Cables not connected or ending in a junction box in the steering gear room. 46CFR183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 29 July 2020
Resolution: Vessel sent in pictures of the wires being properly secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 May 2020 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Shaft penetration through the bulkhead is not watertight. 46CFR171.114(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 29 July 2020
Resolution: Vessel sent in pictures of the through holes with proper sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 May 2020 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessels name. Vessels name has faded from the ring lifebuoy. 46CFR185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2020
Resolved 29 July 2020
Resolution: Vessel sent in pictures of the life ring with its new lettering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2020 Resolved
Vessel is replacing both MDE's along with new reduction gears and electronic throttles.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 July 2020
Resolved 29 May 2020
Resolution: Vessel performed DVTPs IAW manufacturers instruction satisfactorly. Full power trials and crash stop SAT as well
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 25 April 2019 Resolved
01 MSD valve not secured. Secure MSD valve with proper lock to prevent accidental discharge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Valve secured
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 25 April 2019 Resolved
02 Automatic bilge pump indicating light for cargo space and engine room not operational. Fix indicating lights for automatic bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Fixed indicating light
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2019 Resolved
03 Exposed wire splices on aft of mast. Cover with junction box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Covered exposed wire.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 April 2019 Resolved
04 Radiotelephony Safety certificate is expired. Provide valid certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Provided updated certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2019 Resolved
05 Outlet cover in STBD, aft of engine room missing. Replace cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Outlet cover provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2019 Resolved
06 Waterlight for ring bouy not operational. Provide working waterlight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 29 May 2019
Resolution: Waterlight operational
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 April 2018 Resolved
Found expired meds in first aid kit, replace all expired meds.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: First Aid Kid replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 April 2018 Resolved
Overhead was found leaking water with a temp repair of plastic to keep water out of junction box. Make repairs to overhead to keep water out of junction box.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: Junction box moved to appropriate location.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 April 2017 Resolved
Install GPD tp VHF-DSC IAW 47 CFR 80.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 22 May 2017
Resolution: VHF to GPS installed and working.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 5 April 2017 Resolved
Make high water visual and audible alarm in lazarett operate correctly. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 9 May 2017
Resolution: Bilge audible and visual alarms operational.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 April 2017 Resolved
Update and maintain drill logs IAW 46 CFR 185.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 9 May 2017
Resolution: Logs updated.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 April 2017 Resolved
Provide proof of supervisory training completion, IAW 46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 22 May 2017
Resolution: Provided training cert.
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 5 April 2017 Resolved
Demonstrate that flow meters are installed and working properly IAW 46 CFR 182.425
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 22 May 2017
Resolution: Flow meters installed and checked on both engines.
Stability › Watertight Integrity › General
Issued 5 April 2017 Resolved
Remove sluice valve and cap to prevent water draining from fwd collision bulkhead to aft compartment IAW 46 CFR 179.320
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 9 May 2017
Resolution: Piping capped off.
Engineering › Electric Propulsion System › Battery
Issued 25 April 2016 Resolved
STBD battery could not hold sufficient charge. Replace battery.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 24 May 2016
Resolution: Battery was replaced and working.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 25 April 2016 Resolved
Vessel had improper fuel lines leading from fuel filter to fuel tank. Install line that meets J1942.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Proper hose was installed and checked.
Engineering › Fuel Oil Service System › Valve
Issued 25 April 2016 Resolved
Fuel shut off valve was inoperable. Make valve operable IAW. 46 CFR 182.455
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Both port and stbd fuel shut off valve worked properly.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2016 Resolved
Provide visual means to indicate operation of submersible electric pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: All bilge pump indicators at operating station showed light when running.
Communications › Alarms/Indicators › High Water Alarm
Issued 25 April 2016 Resolved
Provide visual and audible alarm for bilge high level alarms. Visual inspection of all voids shall be conducted and logged at intervals of no more than 20 min until repaired
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: All high water alarms worked at operating station.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 25 April 2016 Resolved
No updated harbor chart for vessels area of operation. Obtain and make available updated chart.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Charts and pubs updated.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 April 2016 Resolved
Provide and update drug testing program documentation for all crew members.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Provided paper work with all crew members on DAPI program.
Electrical › Electric Supply System (service) › Cable
Issued 25 April 2016 Resolved
Secure all exposed wiring in cargo compartment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Wiring in cargo space was secured properly.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 25 April 2016 Resolved
EPIRB hydrostatic release unit was expired. Replace EPIRB hydrostatic release unit marked with the correct 2 year expiration date.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: New hydra release was installed and properly marked.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 25 April 2016 Resolved
Repair/Replace gauge to indicate engine RPM at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: RPM gauges worked for both main engines.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 March 2016 Resolved
Make the four internal bulkheads seperating the spaces as water-tight as possible (fill all holes, etc.). IAW 46 CFR 179.212
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: All four internal bulkheads were made water-tight.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 3 March 2016 Resolved
Ensure all electrical outlets in the engine room space have covers (to shield the outlet from moisture when nothing would be plugged in). IAW 46 CFR 183.210
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: All electrical outlets were made secure.
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 March 2016 Resolved
Remove the extra battery lying on the hull planking, in the engine-room. IAW 46 CFR 183.350.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 26 April 2016
Resolution: Extra battery was removed from hull-planking.
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 May 2014 Resolved
Install positive-action valve or cock on all hull penetrations where keel cooler piping passes through hull. 46CFR171.119.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 16 May 2014
Resolution: Deficiency was reviewed by Branch Chief and was determined positive action valves at keel coolers were not needed. Not support by T&K Manual.
Communications › Alarms/Indicators › High Water Alarm
Issued 15 May 2014 Resolved
Repair or replace high water alarm lights at operating station for fwd and lazarette compartments.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 16 May 2014
Resolution: High water alarm lights were replaced and operational. Def Cleared.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 May 2014 Resolved
Provide original Certificate of Inspection and Certificate of Documentation onboard vessel.
Action required: 705 - Other - as specified
Due 22 May 2014
Resolved 16 May 2014
Resolution: Original documents were verified onboard. Def Cleared.
Construction/Loadline › Hull › Transverse Frame
Issued 15 May 2014 Resolved
Effect repairs to the following structural components at next drydocking or not later than January 2015: All sistered frames throughout vessel, longitudinal stiffener located in fwd compartment. Sistered frames list to be provided after marine inspector meets with shipwright.
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 3 March 2016
Resolution: All items had either previously been addressed or were addressed during the vessel's 2016 dry-docking.
Fire Fighting › Fire Pumps › Bearings
Issued 15 May 2014 Resolved
Replace or repair fire pump due to overheating/smoking bearings in clutch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2014
Resolution: Fire pump was replaced and operated sat. Def Cleared.
Stability › Severe Wind/Roll › General
Issued 15 May 2014 Resolved
Remove salt bags (2000 pounds of ballast) from fwd compartment per stability letter and 46CFR178.230
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 15 May 2014
Resolution: All unauthorized ballast removed
Documentation › Certificates/Documents › FCC SSL
Issued 18 March 2008 Resolved
Provide current FCC safety certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2008
Resolution: Provided valid certificate.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 18 March 2008 Resolved
Demonstrate proper operation of fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2008
Resolution: Tested fire system, test sat.
Communications › Radio Communications › EPIRB
Issued 18 March 2008 Resolved
Provide EPIRB with current registration, hydrostatic release, and battery. Vessel is limited to lakes, bays, and sounds route prior to completion.
Due 1 March 2012
Resolved 1 March 2012
Resolution: At the COI inspection on 31 Mar 11 this item was visually examined with satisfactory results.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 March 2008 Resolved
Demonstrate satisfactory crew drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2012
Resolution: Drills were conducted on 31 Mar 11 at the COI inspection.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 18 March 2008 Resolved
Demonstrate high alarm level switches function properly, and label.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2008
Resolution: Tested alarm, all functioned properly.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 18 March 2008 Resolved
Replace buoyant apparatus lifeline.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2008
Resolution: Lifeline was replaced.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 18 March 2008 Resolved
Replace life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2008
Resolution: Lifering was replaced
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 March 2008 Resolved
Repair exhaust leak on starboard engine.
Due 18 April 2008
Resolved 1 March 2012
Resolution: There was no exhaust leak at the COI inspection.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 May 2006 Resolved
Provide 11 Adult Type I PFDs in serviceable condition approved under 46 CFR 160.055 as required by 46 CFR 180.71 and marked in accordance with 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 May 2006 Resolved
Found Type I PFDs in poor material condition. Service all PFDs. Clean outer protective covers, remove scale from strap securing devices, renew retro reflective tape and mark all jackets IAW 46 CFR 185.604. (46 CFR 181.71)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Communications › Alarms/Indicators › Propeller Direction Indicator
Issued 31 May 2006 Resolved
Found propulsion engine tachometers inoperative. Repair/replace as originally fitted. (46 CFR 182.410)
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Engineering › Fuel Oil Service System › Hose
Issued 31 May 2006 Resolved
Properly secure/support fuel oil service system flex hose assemblies from storage tank to strainer assemblies and protect from mechanical damage as required by 46 CFR 182.455.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 31 May 2006 Resolved
Provide suitable portable containment for propulsion engine block/case drains. (46 CFR 182.100)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 31 May 2006 Resolved
Clean propulsion engine air cleaners, repair protective screen and install/secure suitable piping from crankcase breather assembly to air cleaner. (46 CFR 182.100)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Engineering › Bilge Water Management System › Pump
Issued 31 May 2006 Resolved
Install electric submersible pumps in machinery space, steering compartment and main cabin bilge in accordance with 46 CFR 182.520(e).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 31 May 2006 Resolved
Repair or remove broken/wasted main deck light fixtures and install suitable guard on light fixture in passenger accommodation. (46 CFR 183.410)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 31 May 2006 Resolved
Remove dead-ended electrical conductors/cables, improper conductor splices, install suitable cable securing devices, properly support electrical conductors and cable and provide suitable junction boxed for conductor splices throughout vessel's 12 volt electrical service system as required by 46 CFR 183.05-50.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 May 2006 Resolved
Found water cooled diesel engine exhaust piping (cooling water supplied by a system separate from engine cooling) not fitted with a suitable visual or audible warning device to indicate the failure of water flow in the exhaust system. Install suitable device at operating station as required by 46 CFR 182.15-15 as referenced by 182.20-15.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Construction/Loadline › Hull › Side Shell
Issued 28 February 2006 Resolved
Repair to as built specifications, wasted plank end on plank #21 (Aft of stem) starboard side as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Construction/Loadline › Hull › Stringer
Issued 28 February 2006 Resolved
Refasten bilge clamp to deck stanchions in lazarette as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Construction/Loadline › Hull › Girder
Issued 28 February 2006 Resolved
Repair outboard deck carling in lazarette (rotted end) to as built specifications as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Construction/Loadline › Hull › Transverse Frame
Issued 28 February 2006 Resolved
Repair wasted frame #4 (forward of transom), port side to as built specifications as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Construction/Loadline › Hull › Side Shell
Issued 28 February 2006 Resolved
Repair areas of minor localized decay throughout vessel as marked by marine inspector IAW NVIC 7-95 as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Engineering › Steering Gear System › Piping
Issued 28 February 2006 Resolved
Secure steering system hydraulic piping in lazarette as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Engineering › Steering Gear System › Ram Seal
Issued 28 February 2006 Resolved
Repair as built. specifications, hydraulic ram on steering system as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Engineering › Bilge Water Management System › Valve
Issued 28 February 2006 Resolved
Replace valve on bilge piping system in fore peak as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Construction/Loadline › Hull › Stiffener
Issued 28 February 2006 Resolved
Repair frame #3 in winch compartment just aft of fwd blkhd to as built specifications as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Construction/Loadline › Hull › Strut/Cross Tie
Issued 28 February 2006 Resolved
Re-fasten port side stanchion in storage compartment as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 28 February 2006 Resolved
Install handles on all hull penetration valves and prove proper operation as required by 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 6 March 2006
Documentation › Certificates/Documents › FCC SSL
Issued 26 May 2005 Resolved
Provide valid FCC Station License as required by 47 CFR 80
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 27 May 2005
Resolution: Station License was provided.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 May 2005 Resolved
Provide valid certificate of documentation as required by 46 CFR 67.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 27 May 2005
Resolution: Proof of valid Certificate of Documentation was provided.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 26 May 2005 Resolved
Mark vessel's name and home port in accordance with 46 CFR 67.122 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 6 March 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 May 2005 Resolved
Renew expired aspirin and eyewash as required by 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 27 May 2005
Resolution: New aspirin and eyewash were provided
Stability › Watertight Integrity › General
Issued 26 May 2005 Resolved
Provide securing devices of watertight hatches IAW 46 CFR 179.360
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 27 May 2005
Resolution: Securing devices were provided.
Stability › Watertight Integrity › General
Issued 26 May 2005 Resolved
Repair slight leak around stuffing box as per NVIC 7-95.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 27 May 2005
Resolution: Leak was resolved by tightening bolts and recaulking.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 26 May 2005 Resolved
Provide satisfactory evidence of the fixed gas fire suppression system servicing as required by 46 CFR 176.810(b)(2) to the attending marine inspector for review.
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 9 August 2005
Resolution: Received fixed firefighting service report.
Electrical › Electrical Distribution System (service) › Conductor
Issued 26 May 2005 Resolved
Secure electrical wiring and cables with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage as required by 46 CFR 183.340(b)(4).
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 6 March 2006
Engineering › Fuel Oil Service System › Tank
Issued 26 May 2005 Resolved
Electrically bond fuel oil tank to vessel's hull as required by 46 CFR 182.440
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 27 May 2005
Resolution: Tanks were bonded to the hull.
Engineering › Fuel Oil Service System › Hose
Issued 26 May 2005 Resolved
Electically bond non-metallic portion of fuel oil fill pipe as required by 46 CFR 182.445
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 27 May 2005
Resolution: Fill pipe was bonded.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 26 May 2005 Resolved
Repair and prove operation of port main engine as per 46 CFR 182.200.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 27 May 2005
Resolution: Engine was repaired and proven operational.
Lifesaving › Hand Flares › Quantity
Issued 26 May 2005 Resolved
Provide 6 red hand flares as required by 46 CFR 180.68
Action required: 705 - Other - as specified
Due 26 June 2005
Resolved 27 May 2005
Resolution: 6 red hand flares were provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 May 2005 Resolved
Conduct man overboard and fire drill as required by 46 CFR 185.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 27 May 2005
Resolution: Sat drills were conducted.
Construction/Loadline › Hull › Bottom Plating
Issued 5 May 2004 Resolved
Repair leak in hull at junction of transom and bottom planking.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2004
Resolved 13 May 2004
Resolution: Stuffed leaky area with cotton and caulked.
Engineering › Shafting/Propeller Arrangements
Issued 12 July 2002 Resolved
Replace shaft log to port shaft. LEGACY COMPONENT DESC: Propeller Shaft
Due 19 July 2002
Resolved 19 July 2002
Operations/Management › Drills/Instruction
Issued 12 July 2002 Resolved
Conducted sea trails. LEGACY COMPONENT DESC: Sea Trails
Action required: 705 - Other - as specified
Due 19 July 2002
Resolved 19 July 2002
Construction/Loadline › Hull
Issued 12 July 2002 Resolved
Make repairs to port/starboard most frams adjacent to transom iaw NVIC 7-95. Submit repair proposal prior to comencing repairs. LEGACY COMPONENT DESC: Frames
Due 19 July 2002
Resolved 19 July 2002
Engineering › Bilge Water Management System
Issued 12 March 2002 Resolved
renew valve in steering compartment bilge ovbd discharge LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 3 April 2002
Resolution: Valve replaced in steering compartment bilge overboard discharge.
Deck/Cargo › Holds/Tanks
Issued 12 March 2002 Resolved
renew hatch gasket on aft deck LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 3 April 2002
Resolution: Replaced hatch gasket on aft deck.
Navigation
Issued 20 January 2000 Resolved
PROVIDE SUPPORT BRACKETS FOR HYDRAULIC HOSES IN ENGINE ROOM AND FORWARD STORAGE COMPARTMENT IAW 46 CFR 182.720.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Engineering
Issued 20 January 2000 Resolved
REPLACE COPPER VENT PIPE ON FUEL TANK STARBOARD SIDE OF ENGINE ROOM IAW 46 CFR 182.450(a).
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Engineering
Issued 20 January 2000 Resolved
REFASTEN CLAMPS ON FUEL FILL HOSES ON FUEL TANKS IN ENGINE ROOM IAW 46 CFR 182.445(g).
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 17 March 1998 Resolved
PERIPHERY OF CABIN FRAME AT MAIN DECK WAS FRESH WATER ROTTED,
Condition: Unknown
Due 17 March 1998
Resolved 20 March 1998
Lifesaving
Issued 4 March 1997 Resolved
PROVIDE A FLARE CONTAINER THAT MEETS THE REQUIREMENTS OF 46 CFR 180.68(e) AND IS MARKED IAW 46 CFR 185.614.
Condition: Unknown
Due 4 April 1997
Resolved 19 June 1997
Lifesaving
Issued 4 March 1997 Resolved
CONDUCT TRAINING W/VSL CREWMEMBERS TO ENSURE FAMILARITY W/BILGE PUMPING ARRANGEMENTS AND OPERATION OF ALL EQUIPMENT. _x001C_ _x001C_ 46 CFR 185.420
Condition: Unknown
Due 4 April 1997
Resolved 19 June 1997
Lifesaving
Issued 4 March 1997 Resolved
REPAIR/REPLACE 4 EACH, ADULT SIZED PERSONNEL FLOATATION DEVICE (PFD), AS INSTRUCTED BY CG MARINE INSPECTOR. UNTIL EXAMINATION, THE MAXIMUM NUMBER OF ADULT PERSONS IS LIMITED TO 71 TOTAL PERSONS. _x001C_ 46 CFR 180.71
Condition: Unknown
Due 4 April 1997
Resolved 19 June 1997
Lifesaving
Issued 4 March 1997 Resolved
PROVIDE FOR VSL AN EMERGENCY POSITION INDICATING RADIO BEACON (EPIRB) THAT MEETS THE REQUIREMENTS OF 46 CFR 180.64 (ie, 406MHz Cat 1 EPIRB). PROVIDE TEST LOG THAT MEETS 46 CFR 185.728. TO BE PROVIDED PRIOR TO 11MAR97 OR ROUTE IS RESTRICTED TO NOT MORE THAN 3 NAUTICAL MILES FROM SHORE.
Condition: Unknown
Due 4 April 1997
Resolved 19 June 1997
Navigation
Issued 4 March 1997 Resolved
REPACK BOTH RUDDER SHAFT PACKING GLANDS TO REDUCE LEAKAGE. _x001C_ _x001C_ _x001C_ 46 CFR 176.814
Condition: Unknown
Due 4 April 1997
Resolved 19 June 1997
Construction/Loadline
Issued 26 March 1996 Resolved
NUMERIOUS HULL REPAIRS RESULTING FROM STORM DAMAGE (HURRICANE OPAL) WERE COMPLETED DURING THIS REPAIR/CREDIT DRYDOCK PERIOD, SEE MINS CASE NUMBER MI96005986 FOR DETAILS.
Condition: Unknown
Due 26 March 1996
Resolved 13 May 1996
Construction/Loadline
Issued 8 May 1995 Resolved
REPLACE WIND AND WATER PLANK ON PORT SIDE.
Condition: Unknown
Due 30 October 1995
Resolved 31 May 1995
Construction/Loadline
Issued 8 May 1995 Resolved
RECHAULK DECK PLANKING.
Condition: Unknown
Due 30 October 1995
Resolved 31 May 1995
Construction/Loadline
Issued 8 May 1995 Resolved
RENEW ENTIRE SKEG AND WORM SHOE AT NEXT DRYDOCK.
Condition: Unknown
Due 30 October 1995
Resolved 31 May 1995
Engineering
Issued 23 March 1995 Resolved
LABEL EMERGENCY FUEL SHUTOFFS ON EXTERIOR OF ENGINE COMPARTMENT.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Documentation
Issued 23 March 1995 Resolved
POST STABILITY LETTER AT HELM STATION UNDER GLASS AS REQUIRED BY 46 CFR 185.20-5(a).
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Unknown
Issued 23 March 1995 Resolved
VESSEL'S ROUTE TO BE REDUCED TO LAKES, BAYS, AND SOUNDS ROUTE UNTIL COMPLETION OF A SATISFACTORY HULL EXAMINATION.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Construction/Loadline
Issued 23 March 1995 Resolved
SUBMIT PROPOSAL FOR REAIRS TO ACCOMPLISH COMPLETION OF SPECIFIED HULL REPAIRS AS NOTED IN WORKLIST ISSUED 23MAR95, ITEMS -1- THROUGH -6-. ALL REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Unknown
Issued 23 March 1995 Resolved
REMOVE AN PROPERLY DISPOSE OF OILY BILGE SLOPS IN THE FORWARD STORAGE COMPARTMENT AND ENGINE ROOM COMPARTMENT BILGES.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Construction/Loadline
Issued 12 February 1991 Resolved
RENEW THE COLLISION BHD,_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 February 1991
Resolved 12 February 1991
Construction/Loadline
Issued 12 February 1991 Resolved
REPAIR WASTED SECTION OF UNDER DECK BEAM. PORT SIDE OF FWD TRUNK CABIN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 February 1991
Resolved 12 February 1991
Construction/Loadline
Issued 12 February 1991 Resolved
REPLACE THE MISSING SECURING BOLTS FOR THE BOW HATCH.
Condition: Unknown
Due 12 February 1991
Resolved 12 February 1991
Lifesaving
Issued 8 March 1990 Resolved
REPLACED 3 A & 1 C PFD'S.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990 Resolved
REPLACE PLASTIC SPOOLPIECES IN BHDS W/ METAL.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990 Resolved
RENEWED OVERHEAD IN MAIN DECKHOUSE.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990 Resolved
RECAULKED COLLISION BHD
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990 Resolved
REPLACED ROTTED PLANK ON PORT BOW AT SHEAR STRAKE.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990 Resolved
REFASTENED GARBOARD AREA.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Construction/Loadline
Issued 8 March 1990 Resolved
REPLACED PLASTIC THRU HULLS W/ METAL.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Navigation
Issued 8 March 1988 Resolved
RELOCATED MASTHEAD LIGHT SO TO PLACE LIGHT 1 METER ABOVE SIDE LIGHT.
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Lifesaving
Issued 17 March 1987 Resolved
PROVIDE 1 CHILDREN'S LIFEJACKET.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Accommodation/Occupational Safety
Issued 17 March 1987 Resolved
PROVIDE ONE EXHAUST VENT TO LOWER SECTION OF MACHINERY SPACE.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Electrical
Issued 17 March 1987 Resolved
REMOVE RADIO WIRES FROM DIRECT CONTACT WITH BATTERY. PLACE BEHIND MAIN DISCONNECT AND PROVIDE OVERCURRENT PROTECTION.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Construction/Loadline
Issued 17 March 1987 Resolved
REMOVE 2 KEEL BOLTS FOR EXAMINATION IN LAZZARETTE.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Construction/Loadline
Issued 17 March 1987 Resolved
REPAIR ROTTED RIB, PORT SIDE, 2ND FROM STERN AND ASSOCIATED UNDER DECK BEAM.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Engineering
Issued 17 March 1987 Resolved
REMOVE OIL FROM ENGINE ROOM BILGE.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Construction/Loadline
Issued 17 March 1987 Resolved
INSTALL METAL SPOOL PIECES IN BILGE SUCTION LINES OF SECOND BULKHEAD FROM BOW.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Electrical
Issued 17 March 1987 Resolved
REROUTE STARTER POWER CABLE FROM DISCONNECT SWITCH TO STARBOARD DIESEL AND SECURE TO CUTOUT SWITCH.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Fire Fighting
Issued 17 March 1987 Resolved
PROVIDE 1 B-II PORTABLE FIRE EXTINGUISHER FOR PASSENGER ACCOMMODATION SPACE.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987
Construction/Loadline
Issued 18 December 1985 Resolved
MAKE ALL EXPOSED DECK HATCHES SECURE TO VESSEL BY MEANS OF CHAIN.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Construction/Loadline
Issued 18 December 1985 Resolved
MAKE WATERTIGHT THE BULKHEAD BETWEEN ENGINE ROOM AND AFT COMPARTMENT IN THEAREA OF THE PORT SHAFT.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985

Casualty record · 1

11 July 2002Routine · role: Involved in a Marine Casualty · activity 1658463
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.