Records from 1985 to 1991. Most recent: inspection, 8 February 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
8 February 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216252
31 October 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320236
25 August 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 992871
14 January 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303361
1 November 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 989007
6 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 976480
Engineering
Issued 14 January 1986
Resolved
MAKE THE SIX (6) START AIR, THE SHIP SERVICE AIR AND THE WHISTLE AIR RECEIVERS READY FOR INTERNAL INSPECTION OR HYDRO TEST.
Condition: Unknown
Due 15 February 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 14 January 1986
Resolved
MAKE THE LOW HEAT BOILER READY FOR INTERNAL INSPECTION AND HYDROSTATIC TESTAND ALSO REPAIR EXTERNAL CONTROL ELECTRICAL WIRING.
Condition: Unknown
Due 15 February 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 14 January 1986
Resolved
MAKE PERMANENT REPAIR TO SALT WATER LINE IN WAY OF #3 PORT BUOYANCY SPACE AT END OF NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 14 January 1986
Resolved
PROVE PROPER OPERATION OF VENTILATION SYSTEM FOR DECK HOUSE.
Condition: Unknown
Due 15 February 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 14 January 1986
Resolved
PROVIDE NEW FIRE CONTROL PLANS.
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 February 1985
Resolved
REPAIR OF THE WASH BOARDED SIDESHELL IN THE BOW (PORT & STARBOARD) C & D STRAKES FROM FR# 23 FWD, THEIR ASSOCIATED INTERNAL STRUCTURE (INCLUDING THESWASH BHDS, TRIPPING BRACKETS AND SIDE TRANSVERSES) IN WAY OF THIS AREA SHALL BE ADDRESSED AT THE NEXT SCHEDULED DRY DOCK EXAM.
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 6 February 1985
Resolved
RESUSPEND THE ELECTRICAL CABLES ON THE STEEL CLIPS LOCATED BETWEEN NUMBER 3CARGO TANK P/S ACCESS TRUNKS.
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 6 February 1985
Resolved
RENEW THE STARBOARD "DECK WINCH" MOTOR CONTROLLER BOX.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Construction/Loadline
Issued 6 February 1985
Resolved
RENEW WASTED PORTIONS OF PORT AND STARBOARD W.T. DOORS TO NUMBERS 1 & 3 "BUOYANCY SPACES".
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 February 1985
Resolved
RENEW THE RUBBER GASKETS IN THE PORT AND STARBOARD W.T. DOORS TO NUMBERS 1, 2 AND 3 "BUOYANCY SPACES".
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 February 1985
Resolved
RENEW THE WASTED STEEL LIP ON THE FORECASTLE W.T. DOOR AND RENEW ITS GASKET.
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 6 February 1985
Resolved
REMOVE OR SEAL OFF THE CARGO TANKS OVERFILL/OVERBOARD PIPE LINES.
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 6 February 1985
Resolved
PROVIDE 2 B-II UL/FM (APPROVED FOR MARINE USE) OR COAST GUARD APPROVED PORTABLE FIRE EXTINGUISHERS IN THE ENGINEROOM FOR THE SMALL OIL FIRED HEATING BOILER.
Condition: Unknown
Due 30 April 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past