Records from 2007 to 2026. Most recent: inspection, 23 June 2026.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel's recovery platform for man overboard drill was deemed unsafe and impractical for recovering someone in the water.
46 CFR 176.830
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 23 June 2026
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 May 2026
Resolved
For each marine casualty required to be reported by § 185.202, the owner, agent, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. Vessel did not have any alcohol testing strips onboard the vessel.
46 CFR 185.210(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 13 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 May 2026
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Vessel did not have a portable hand pump onboard.
46 CFR 182.25-10(a)
Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 15 May 2026
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 May 2026
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Vessel's VHF-DSC radiotelephone does not have the GPS connected to it.
47 CFR 80.905(a)(1)
46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 13 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Life jackets on the upper deck missing physical divider to separate child size jackets from adult size life jackets.
46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 13 May 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 May 2026
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacle on board was made of plastic, replace with noncombustible material.
46 CFR 177.405(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 17 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2026
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retroreflective tape on the vessel's ring life buoy was worn and needs to be replaced.
46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 15 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2026
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 2 fire buckets but was able to produce the fire buckets prior to completing the inspection.
46 CFR 181.610
Action required: 10 - Deficiency Rectified
Due 12 May 2026
Resolved 12 May 2026
Resolution: Vessel was missing 2 fire buckets but was able to produce the fire buckets prior to completing the inspection. Deficiency rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 May 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] through hull fitting for sink drain is not watertight; approved fitting must be installed. Vessel is restricted to lakes, bays and sounds in fair weather only.
46CFR176.700(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Satisfactory through hull fitting was installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. Upper portion of E/R forward bulkhead is open to the MSD void; Pre-engineered system installed for the E/R is rated only for the cubic feet of that space. Vessel is restricted to lakes, bays and sounds.
46CFR181.420(a)(4)
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Crew sealed up remaining area in the forward E/R bulkhead where it meets the overhead.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 May 2025
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life float on board is unserviceable and must be removed from the vessel. Vessel is restricted to LBS plus limited coastwise no more than 3 miles from shore.
46CFR180.175(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2025
Resolution: reduced route from limited coastwise to limited coastwise only up to 3 nautical miles (NM) from shore IAW table 180.200(c).
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 7 May 2025
Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter. Vessel had an excessive amount of bilge water, approximately over 75 gallons, throughout the E/R and MSD void. Captain shall adhere to the requirements of the stability letter. Remove all bilge water prior to getting underway.
46CFR185.20-5(a)
Old T
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Bilge water has been removed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 7 May 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] area immediately aft of the stern middle seating has cracked plywood, visible on the overhead of the steering compartment, compromising the integrity of the deck. Complete repairs at next scheduled drydock.
46CFR176.700(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 30 December 2025
Resolution: Comnpleted at DD
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2025
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. 03 deck lights powered by the AC generator fixed to the upper deck have exposed ends.
46CFR183.10-20(a)
Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 20 May 2025
Resolution: Holes were plugged with sealant and wiring in the junction boxes in the immediate vicinity were fitted with wire nuts.
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 7 May 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel has only 01 portable light (flashlight).
46CFR183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 20 May 2025
Resolution: Capatin acquired new lights.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 7 May 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Multiple sections of the mounted instructions reference equipment that the vessel is not fitted with.
46CFR185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 20 May 2025
Resolution: Instructions were updated to reflect equipment on board.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 7 May 2025
Resolved
Each marine safety device (MSD) must meet all other safety requirements of the regulations applicable for the type of vessel for which it is certificated. Hose located between the sewage pump and holding tank is missing hose clamps on both ends.
33CFR159.95(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 20 May 2025
Resolution: Clamps were put on the hose.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. The pre-engineered fixed gas fire extinguishing system was expired. A servicing certificate shall be provided to the attending marine inspector prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Provided servicing certificate
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 May 2024
Resolved
Each vessel certificated to operate on a limited coastwise route within three miles of land in warm water must; Have on board a FCC Type Accepted Cat 1 406 MHz EPIRB, installed to automatically float free and activate, and not be required to carry survival craft. The vessels life float was in poor condition and deteriorating with holes and gouges. Rectify to satisfaction of USCG Marine Inspector. The vessel is limited to lakes, bays and sounds until proper installation of EPIRB, installed to automatically float free and activate. Once EPIRB is installed properly, the vessel is limited to 3 miles of land.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 7 May 2025
Resolution: Vessel has EPIRB on board.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 May 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The belts and shaft for the main engine need to be protected to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 4 June 2024
Resolution: Guard was built in place to protect from rotating machinery
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. STBD side deck rail and aft Port rail are lose and need to be tightened to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Lag bolts added to help strengthen rails
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 May 2024
Resolved
For each marine casualty required to be reported by 185.202, the owner, agent, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. The vessel did not have any alcohol testing strips.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2024
Resolution: Test strips were purchased
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 May 2024
Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date has passed. The floating waterlight attached to the ring life buoy had improper alkaline batteries. Replace with manufacture specified batteries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 4 June 2024
Resolution: Correct batteries were installed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. The engine room cover has a 2'x 6' separating from the cover. Rectify to the satisfaction of the attending marine inspector
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Board was reattached and sealed
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 7 May 2024
Resolved
The construction and arrangement of a vessel must allow for safe operation of the vessel in accordance with the terms of its Certificate of Inspection. There is no visibility out of the port and starboard windows in the wheelhouse as the material used obstructs the visibility. Rectify to the satisfaction of the attending marine inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 4 June 2024
Resolution: Windows have been replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2024
Resolved
An adult lifejacket must be provided for each person carried on board a vessel. 04 life jackets on board had holes and need to be replaced to the satisfaction of the attending marine inspector. Vessel is limited to 44 passengers, 46 max total persons allowed.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 4 June 2024
Resolution: Replaced with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2024
Resolved
Requirements for the design, construction, installation, and operation of electrical equipment and systems including power sources, lighting, motors, miscellaneous equipment, and safety systems complying with ABYC where applicable. Main engine battery post cannot exceed 04 terminals per post. The vessel has exceeded the number allowed by ABYC standards. Rectify to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 4 June 2024
Resolution: Vessel corrected by adding a terminal strip
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 7 May 2024
Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. The hailing port on the stern needs to reflect the current operating port.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 4 June 2024
Resolution: Corrected hailing port on the stern
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 May 2024
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone. Vessel does not have GPS connected. Rectify to the satisfaction of the attending Marine Inspector.
47 CFR 80.905(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 5 August 2024
Resolution: New VHF radio was installed, verified GPS signal and MMSI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2024
Resolved
All electrical equipment and circuits must be clearly marked and identified. 2 breakers in the wheelhouse did not have adequate labeling. Rectify to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2024
Resolution: Proper labeling was added to breakers
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 May 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publications; Coast Guard Light list; Tide Tables; and Current Tables, or river current publications. All publications on the vessel where from 2011.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 May 2024
Resolved 4 June 2024
Resolution: Replaced with new paper charts
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 August 2023
Resolved
At least once every three months the emergency drills shall be conducted. No drill logs kept onboard.
46 CFR 185.420 (b)
Action required: 10 - Deficiency Rectified
Due 24 August 2023
Resolved 24 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 August 2023
Resolved
Portable extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the [name withheld] extinguishers where not in brackets, proper location, or properly labeled.
46 CFR 181.520
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2023
Resolved 26 August 2023
Resolution: Vessel installed fire extinguisher brackets, proper labeling, and correct locations.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 August 2023
Resolved
The master of the vessel shall ensure that Each EPIRB is tested monthly. The EPIRB test required shall be logged. No EPIRB testing logs where found onboard.
185.728 (a) & (c)
Action required: 10 - Deficiency Rectified
Resolved 24 August 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 August 2023
Resolved
Batteries shall be located as high above the bilge as practical and secured against shifting from the motion of the boat. They shall be accessible without less than 10 inches headroom. generator, start, and house batteries installed in the bilge.
46 CFR 183.05-20
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2023
Resolved 26 August 2023
Resolution: Batterys have been lifted out of bilge and properly secured.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 July 2023
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel does not have a valid Certificate of Inspection on-board.
46 CFR 176.100 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2023
Resolved 24 August 2023
Resolution: Completed annual inspection.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 June 2018
Resolved
missing 04 pfd's
reduced passenger count until 04 pfd's are placed onboard
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 5 June 2019
Resolution: corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 June 2018
Resolved
two battary box covers
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2019
Resolution: corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2018
Resolved
replace wire nuts in juncution boxes
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 5 June 2019
Resolution: corrected
Lifesaving › Lifefloat › Paddle
Issued 21 March 2017
Resolved
Life float needs paddels. New paddles must have vessel name stenciled on them.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 March 2017
Resolved
Re-retro worn retro on 09 life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 28 March 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 March 2017
Resolved
Replace 60 feet of life line on life ring.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 March 2017
Resolved
Replace worn retro reflective marking on life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 28 March 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 March 2017
Resolved
Replace worn child size life jacket. Until replaced, vessel may not carry more than 8 children.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 24 April 2017
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 21 March 2017
Resolved
Provide proof of FCC registration of vessels radio station license.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 22 March 2017
Resolution: Received proof that the FCC registration for the radio station license has been renewed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 March 2017
Resolved
Bind and support all wires overhead in engine room with metal supports as discussed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 28 March 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 March 2017
Resolved
Replace worn hydralic hose that operates the steering system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2017
Resolved 21 March 2017
Electrical › Electric Generation Source (service) › Generator Cable
Issued 21 March 2017
Resolved
Replace clamp in generators cooling line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2017
Resolved 21 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 21 March 2017
Resolved
Replace glass globe for light in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 28 March 2017
Fire Fighting › Fire Bucket › Availability
Issued 21 March 2017
Resolved
Vessel is required to have 3 2.5 gallon fire buckes with lanyards.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 21 March 2017
Resolved
Provide proof of DAPI enrollment for vessels deck hand prior to operation of vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 21 March 2017
Resolution: Vessel owner provided proof of deck hands enrollment in random drug/alcohol testing program.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 2 June 2016
Resolved
Place cover over space in bridge generator electric pannel.
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 9 June 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 June 2016
Resolved
Replace cover on electrical outlet on bridge.
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 9 June 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 June 2016
Resolved
Replace retro reflective tape on 05 life jackets. No more than 48 persons carried on board.
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 9 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2016
Resolved
Cap all dead end wires in engine space.
Due 9 June 2016
Resolved 9 June 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 2 June 2016
Resolved
Correctly mount raw water pump to sewage tank.
Due 9 June 2016
Resolved 9 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2016
Resolved
Secure loose wires above the main engine.
Due 9 June 2016
Resolved 9 June 2016