← All vessels
HD PIONEER
HD PIONEER is a 1996 industrial vessel. The Coast Guard has recorded 38 inspections since 1994, most recently in May 2017, along with 44 deficiencies and 1 casualty investigation in 2012.
Records from 1994 to 2017. Most recent: inspection, 24 May 2017.
- Built
- 1996
- Last inspected
- 24 May 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 44 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2012
Identity
1040503
9117246 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H9MU
437663
Flag
PANAMA
368335000 (licence lapsed)
Maury page id
psix-437663
Inspections, by type
…with no type recorded3
Years with a record
17 calendar years (1994–2017)
The 38 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Tonnage as PSIX records it2503 - Convention (Subpart B), Gross Ton
750 - Convention (Subpart B), Net Ton
750 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCW9255MMSI 368335000 · expired · compulsorily equipped · granted 17 August 2006, cancelled 31 December 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 38
24 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6154497
11 March 2014
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4814010
15 February 2012
ACP COI Oversight
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4242334
15 March 2010
ACP Periodic Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3696275
29 December 2008
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3386011
15 November 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3363812
10 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3232553
25 February 2008
ACP Annual Oversight · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3159813
23 February 2007
Ballast Water Examination · MTSA/ISPS Verification · MARPOL Annex II Examination · ACP COI Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2892306
16 February 2007
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2873163
12 December 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2550010
7 October 2005
ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2512970
18 June 2004
MTSA/ISPS Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2102366
7 June 2004
ACP COI Oversight
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2091512
31 March 2004
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2034961
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972313
18 August 2003
Annual Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1867525
12 December 2002
Periodic Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1718170
21 February 2002
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1488039
29 August 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444594
5 March 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1062865
13 February 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1386959
18 September 2000
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1369853
30 August 2000
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1386857
4 January 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1057029
10 December 1999
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1438941
20 October 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1391126
15 September 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784773
26 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1107253
2 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804813
15 April 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123418
8 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801479
16 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808537
21 September 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433391
16 January 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396856
28 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 138498
26 November 1996
Initial Construction-Excluding Oversight · Hull Examination · COI Inspection · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421243
15 June 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1463849
Deficiency record · 44
Lifesaving › Launching Appliances › Lines
Issued 15 March 2010
Resolved
Renew wire rope for rescue boat, port and stbd inflatable life raft launch davit.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 August 2008
Resolved
33U.S.C.1321(j)(5)(D)(i)-Format of plan is inconsistent with recently submitted fuel information
Construction/Loadline › Penetrations
Issued 18 August 2003
Resolved
Properly pack watertight bulkhead penetrations in both port and starboard pontoons as required by 46 CFR 171.111(e). LEGACY COMPONENT DESC: Packing
Engineering › Bilge Water Management System
Issued 15 August 2003
Resolved
Properly install strainer on the stbd pontoon aft pump room bilge suction as required by 46 CFR 56.50-55(g) LEGACY COMPONENT DESC: Strainer
Fire Fighting › Ventilation Systems
Issued 15 August 2003
Resolved
Prove proper operation of all deck closures throughout vessel as per 46 CFR 92.15-10(a) LEGACY COMPONENT DESC: Ducts
Fire Fighting › Ventilation Systems
Issued 15 August 2003
Resolved
Provide specifications on fire damper closures in accommodation spaces as required by 46 CFR 97.07.
Electrical › Electrical Distribution System (service)
Issued 15 August 2003
Resolved
Remove portable extension cord from emergency generator room leading through overhead to upper ROV space as per 46 CFR 111.60-13. LEGACY COMPONENT DESC: Wiring
Electrical › Electric Generation Source (emergency)
Issued 15 August 2003
Resolved
Prove proper operation of ground fault on vessel's 480 volt switchboard in emergency generator room as per 46 CFR 111.30-25(e)(1) LEGACY COMPONENT DESC: Ground Indicator
Pollution Prevention/Response › Prevention Equipment
Issued 15 August 2003
Resolved
Make proper repairs to fractured pipe in vessel's MSD system as per 33 CFR Part 159. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Communications › Internal Communications System
Issued 15 August 2003
Resolved
Provide phone located by emergency shutdown station and portable fire extinguisher #16, with an operational handset as required by 46 CFR 113.30-3. LEGACY COMPONENT DESC: Sound-powered Telephone
Communications › Alarms/Indicators
Issued 15 August 2003
Resolved
Provide labeling for vessel's general alarm system as required by 46 CFR 97.37-7. LEGACY COMPONENT DESC: General Alarm
Electrical › Electrical Distribution System (service)
Issued 15 August 2003
Resolved
Update as necessary all circuit directory cards as required by 46 CFR 111.40-11. LEGACY COMPONENT DESC: Distribution Panel Bus
Fire Fighting › Ventilation Systems
Issued 15 August 2003
Resolved
Prove proper operation of ventilation louvers closure in the emergency generator space as required by 46 CFR 95.15-35(b).
Accommodation/Occupational Safety › Occupational Safety
Issued 15 August 2003
Resolved
Properly secure compressed gas cylinders in the upper ROV room as required by 46 CFR 91.25-50.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 15 August 2003
Resolved
Repair or replace portable CO2 fire extinguisher #42 as required by 46 CFR 97.15-60.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 15 August 2003
Resolved
Prove proper operation of #3 & #4 generators and ability to load shed, as required by 46 CFR 111.12-5.
Engineering › Diesel Engine (propulsion-electric)
Issued 15 August 2003
Resolved
Prove high jacket water temperature alarms for generators as required by 46 CFR 111.12-5.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 December 2002
Resolved
Replace battery in starboard bridge wing self igniting light.
Engineering › Fuel Oil Service System
Issued 12 December 2002
Resolved
Repair fuel oil leak on number one generator strainer. LEGACY COMPONENT DESC: Discharge Strainer
Fire Fighting
Issued 29 August 2001
Resolved
REPLACE BROKEN HYDRANT VALVE AT FIRE STATION # 24.
Lifesaving
Issued 29 August 2001
Resolved
REPAIR HYDRAULIC LEAK IN SAT/WINCH ROOM.
Electrical
Issued 29 August 2001
Resolved
PROPERLY INSTALL ELCTRICAL PENETRATION THROUGH WATERTIGHT DECK IN EMERGENCYGENERATOR ROOM.
Documentation
Issued 29 August 2001
Resolved
PROVIDE PROOF OF A VALID CARGO SHIP SAFETY RADIO CERTIFICATE.
Accommodation/Occupational Safety
Issued 29 August 2001
Resolved
INSTALL TWO BUNKS IN HOSPITAL SPACE TO COMPLY WITH ONE PER TWELVE PERSONS OR PORTION OF. 46 CFR 92.20-35
Engineering
Issued 29 August 2001
Resolved
INSTALL BACK FLOW PREVENTERS OR DISCONNECT POTABLE PIPING TO FROM ENGINE EXPANSION TANKS.
Fire Fighting
Issued 29 August 2001
Resolved
LABEL FIXED CO2 VALVES FOR PORT AND STARBOARD GENERATOR ROOMS AND AUXILIARYMACHINERY ROOM.
Documentation
Issued 29 August 2001
Resolved
PROVIDE PROOF OF TWO LICENSED GMDSS OPERATORS.
Documentation
Issued 13 February 2001
Resolved
Update vessel fire safety plans to reflect increase in manning.
Fire Fighting
Issued 18 September 2000
Resolved
Move emergency generator CO2 instructions to a more visible and usable location.
Fire Fighting
Issued 18 September 2000
Resolved
Stencil vessel's name on fantail fire axe.
Electrical
Issued 18 September 2000
Resolved
Prove proper operation of emergency light in starboard aft pump room.
Lifesaving
Issued 18 September 2000
Resolved
Properly secure ladder in starboard forward pump room.
Documentation
Issued 18 September 2000
Resolved
Install new oil discharge placard in aft port pump room.
Navigation
Issued 18 September 2000
Resolved
Install magnetic compass prior to vessel getting underway.
Lifesaving
Issued 18 September 2000
Resolved
Remove tape and plastic covering fire/smoke detector in forward port column.
Electrical
Issued 18 September 2000
Resolved
Replace missing lighting fixture near sewage control panel.
Electrical
Issued 18 September 2000
Resolved
Secure junction box above watertight door to bulkhead in port engine room.
Fire Fighting
Issued 18 September 2000
Resolved
Reconnect CO2 shutdown hoses in starboard forward, aft and forward port thruster rooms.
Deck/Cargo
Issued 16 December 1998
Resolved
CONDUCT CRANE TESTS FOR SHIPS CRANES AS PER 46CFR107.259 AND 46CFR107.260 IN THE PRESENCE OF A MARINE INSPECTOR.
Deck/Cargo
Issued 16 December 1998
Resolved
PROVIDE APPROVED PLANS FOR THE INSTALLATION OF THE SHIPS CRANES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Deck/Cargo
Issued 16 December 1998
Resolved
NA
Documentation
Issued 16 December 1998
Resolved
PROVIDE APPROVED CRANE LOAD CALCULATIONS AS PER 46 CFR 173 AND NEW STABILITY LETTER TO REFLECT CRANE OPERATION TO THE SATISFACTION OF THE ATTENDING MARNE INSPECTOR.
Fire Fighting
Issued 26 November 1996
Resolved
PROVIDE UPDATED COPY FIRE AND SAFETY PLAN FOR APPROVAL
Documentation
Issued 26 November 1996
Resolved
PROVIDE COPY OF ABS NAVIC 10-82 COMPLETION LETTER
Casualty record · 1
7 October 2012Routine · role: Involved in a Marine Investigation (non-casualty) · 1 dead · activity 4503516
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
GLOBAL PIONEER (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.