MAURY USCG vessel records Sign in
← All vessels

LUCKY LADY

LUCKY LADY is a 1959 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 1985, most recently in July 1995, along with 39 deficiencies.

Records from 1985 to 1995. Most recent: inspection, 18 July 1995.

Built
1959
Last inspected
18 July 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WM3896
Flag
UNITED STATES
—
Maury page id
psix-43791

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (1985–1995)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
15 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WUR5412MMSI not assigned · expired · compulsorily equipped · granted 7 April 1994, cancelled 27 June 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

18 July 1995 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1184586
17 July 1995 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1184457
1 July 1994 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1172559
28 June 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 862614
22 December 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1409057
21 December 1993 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 849695
27 April 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 843316
27 April 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1391763
20 November 1991 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 934441
12 July 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 937379
12 July 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1249070
29 April 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1238577
8 May 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1243039
10 April 1990 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1230257
27 March 1990 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1242249
4 April 1989 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1199970
29 March 1988 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1033998
7 March 1988 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1029642
15 April 1987 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1010564
21 April 1986 COI Inspection · Credit Drydock
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1306495
1 April 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 980890

Deficiency record · 39

Construction/Loadline
Issued 22 December 1993 Resolved
PRIOR TO CARRYING PASSENGERS, HULL AND FASTENERS MUST BE THOROUGHLY EXAMINED DURING DRYDOCK EXAM. ALKALI WOOD DETERIORATION IN VICINITY OF THROUGH HULL FITTINGS EXISTS.
Condition: Unknown
Due 5 April 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 27 April 1992 Resolved
PUT RETRO REFLECTIVE TAPE ON B/A
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Electrical
Issued 27 April 1992 Resolved
INSTALL AN ELECTRICAL BONDING SYSTEM
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Fire Fighting
Issued 27 April 1992 Resolved
SERVICE FIRE EXTINGUISHERS
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 29 April 1991 Resolved
VESSEL REQUIRES THREE(3) ADDITIONAL ADULT SIZE LIFE PRESERVERS.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Navigation
Issued 29 April 1991 Resolved
VESSEL REQUIRES CURRENT UPDATEED NAV CHART FOR OP. AREA.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Documentation
Issued 29 April 1991 Resolved
VESSEL OPERATOR MUST SHOW CURRENT FCC OP. LIC..
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Fire Fighting
Issued 29 April 1991 Resolved
VESSEL REQUUIRES PORTABLE FIRE EXT. MOUNTED IN PROPER MARINE TYPE BRACKETS.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Navigation
Issued 29 April 1991 Resolved
RUDDER LINKAGE LOOSE AND RUBBING AREA MUST BE LUBRICATED.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Navigation
Issued 29 April 1991 Resolved
SHOW PROPER OPERATION OF VHF RADIO.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Navigation
Issued 27 March 1990 Resolved
RENEW COTTER KEY ON STEERING LINKAGE AT RUDDER QUADRANT
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Construction/Loadline
Issued 27 March 1990 Resolved
CAP OFF HULL PENETRATION PORT SIDE IN COMPARTMENT FORWARD OF ENGINEROOM
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Construction/Loadline
Issued 27 March 1990 Resolved
SISTER THE PORT BILGE STRINGER APPROX 6' FORWARD OF TRANSOM
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Navigation
Issued 27 March 1990 Resolved
REFASTEN RUDDER SHOE TO KEEL
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Construction/Loadline
Issued 27 March 1990 Resolved
RENEW ROTTEN PLANKS AT STEM PORT SIDE AT SHEER AND AT THE CHINE
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Documentation
Issued 4 April 1989 Resolved
PLACE VALID MARINE DOCUMENT ON VESSEL AND PROVIDE PHOTOCOPY TO [name withheld]
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Unknown
Issued 29 March 1988 Resolved
PROVIDE AN UNDERWAY OPERATIONAL TEST OF THE VESSEL.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Engineering
Issued 29 March 1988 Resolved
REPLACE THE SHIFT CABLE TO THE ENGINE'S TRANSMISSION.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Electrical
Issued 29 March 1988 Resolved
REMOVE DEAD-ENDED AND BLANKED OFF WIRES AND REPLACE TAPED CONNECTIONS WITH UL APPROVED PRESSURE CONNECTOR IN THE STEERING STATION PANEL BOX.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Engineering
Issued 29 March 1988 Resolved
PROVIDE A MEANS TO OPERATE FUEL TANK SHUT-OFF VALVES FROM THE WEATHER DECK AND OUTSIDE OF THE FUEL TANK SPACE.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Electrical
Issued 29 March 1988 Resolved
REMOVE ALL UNUSED LIGHT FIXTURES IN PASSENGER COMPARTMENT.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Unknown
Issued 29 March 1988 Resolved
PROVIDE A COAST PILOT FOR THE VESSEL'S AREA OF OPERATION.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Unknown
Issued 15 April 1987 Resolved
RENEW DRIFT BOLT THROUGH STEM APPROX 6" ABOVE WATERLINE.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
PROVIDE MEANS OF SECURING STEERING GEAR HATCH AND PROVIDE CAPTIVE CHAIN.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
PROVIDE DEVICE FOR SECURING DOGS ON FOREPEAKD AND NR2 HATCH COVER.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
FREE HATCH COVER TO FOREPEAK. FREE DOGGING DEVICES AND PROVIDE CAPTIVE CHAIN.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
FREE DOGGING DEVICES FOR NR2 HATCH COVER AND PROVIDE CAPTIVE CHAIN.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
MAKE COLLISION BULKHEAD AND FORWARD TANK SPACE BULKHEAD WATERTIGHT BY PROP-ERLY CLOSING OFF OLD BILGE LINE PENETRATIONS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
REPLACE 2-BII PORTABLE FIRE EXTINGUISHERS WHICH ARE RUSTED. COMPLETE THIS REQUIREMENT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
PROVIDE SHUT-OFF VALVE ON FUEL LINE AS CLOSE AS POSSIBLE TO DIESEL PROPULSION MACHINERY.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
PROVIDE MEANS OF SECURING FUEL TANK VALVES FROM OUTSIDE TANK SPACE AND FROMACCESSIBLE POSITION ON WEATHER DECK.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
PROPERLY BLOCK THREE BATTERIES IN FUEL TANK SPACE.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
RENEW BILGE LINE TO TWO ELECTRIC BILGE PUMPS. REPLACEMENT MAY BE RIGID NON-METALLIC. NON-RIGID MON-METALLIC MAY BE USED PROVIDED IT IS REINFORCEDAND RESISTENT TO PETROLEUM PRODUCTS. PROVIDE MANUFACTURE SPECIFICATIONS TOSHOW BILGE LINE IS RESISTENT TO PETROLEUM. BILGE LINE SHALL NOT BE LESS
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
RELOCATE MASTHEAD LIGHT SO AS TO BE UNOBSTRUCTED BY RADAR.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
RENEW BOLT CONNECTING HYDRAULIC STEERING RAM TO RUDDER STOCK FLANGE. ELIMINATE COTTER PIN AND PROVIDE BOLT AND NUT ASSEMBLY.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
RENEW WEBBING TO RING BUOY.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
PROVIDE SEPARATE STOWAGE FOR CHILDREN'S PFD'S AND PROPERLY MARK PFD LOCKERS
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
REMOVE OLD UNUSED LIGHT FIXTURES IN PASSENGER COMPARTMENT.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987 Resolved
PROPERLY SECURE HYDRAULIC LINES FOR STEERING LEADING TO AFT STEERING COMPARTMENT AND THROUGHOUT VESSEL.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.